The Bogen TAMB2/PS Telephone Access Module is a unique, dual-purpose voice paging adapter
designed as an interface from a telephone system to a paging system.
This versatile unit offers the capability of station port or trunk port operation, and is compatible with
the full range of analog telephone port types. Advanced design and Bogen dependability make the
TAMB2/PS the perfect choice for simple or complex telephone paging applications.
A background music input (with stereo-combining RCA jacks and volume control), which will accept a line-
level input from a background music source, is provided. This input permits the use of background music
during a page with central paging amplifiers that have no muting provision.
Loop start, ground start, and station port
(90V ring up) compatibility
600-ohm output
Pre-announce and confirmation tones
(defeatable)
Adjustable tone volume
Works with paging only and two-way
(talk back) systems
Background music input with volume control
Suppresses background music during paging
Station access disconnect is dynamically
controlled using a combination disconnect
timer, and VOX disconnect timer or Calling
Party Control (CPC) signal detection
Station port maximum page times from
1- 200 seconds
Disconnect VOX timer is adjustable from
1 to 11 seconds of silence
VOX and default timers independently
inhibitable
Calling Party Control (CPC) signal from switch
immediately disconnects station port
24V Talk Battery
1 Rack space unit height
Flexible Mounting Configuration: wall, single
unit rack, and dual side-by-side rack mount
Easily accessible controls and switches
Trunk Timer feature helps prevent system
blockage
24V power supply required for all modes of
operation (150mA min. capacity); TAMB2PS
includes power supply, TAMB2 does not
1 C-Form (N.O. and N.C.) contact pair available
for operating external equipment
Pluggable terminal strip connectors
FCC Part 68 registered; ETL Listed
Features
Description
Specifications subject to change without notice.
© 2010 Bogen Communications, Inc.
54-8023-49B 1312
Telephone Access
Module
Models
TAMB2, TAMB2PS
NOTE: Power Supply unit
included with TAMB2PS only
Registration Number: US: CD2PA13BTAMB2
Ringer Equivalence: 1.3B
Station Port Compatibility: Two-wire ring start
Trunk Port Compatibility: Two-wire loop start or ground start
Paging Frequency Response: 200 – 8000 Hz, ±1 dB
Input/Output Impedance: 600 ohms, nominal
Power Requirements: 24V DC @ 150mA (supplied with TAMB2PS only)
Pre-announce/Confirmation Tones: 800 Hz, ±20%, one-half second duration
Default Disconnect Timer: 1 to 200 seconds, adjustable or inhibit
VOX Disconnect Timer: 1 to 11 seconds, adjustable or inhibit
Auxiliary Contact Rating: 0.6A @ 125V AC resistive
0.6A @ 110V DC resistive
2.0A @ 30V DC resistive
Operating Temperature Range: 32° – 120°F.
Connection Method: Pluggable screw terminal
Finish: Black enclosure with white lettering
Dimensions: 8-1/2" W x 1-3/4" H x 3" D
Product Weight: 2 lb.
Architect
and Engineer
Specifications
50 Spring Street, Ramsey, NJ 07446
Tel.: 201-934-8500 • Fax: 201-934-9832
www.bogen.com
The telephone-access voice-paging adapter shall
be a Bogen Model TAMB2 (or TAMB2PS) capable
of providing either trunk port or station port
access to paging amplifier, multi-zone paging
adapter, or talk back amplifiers.
The adapter shall have station port compatibility,
2-wire analog with a ringer equivalence number of
1.3B, and trunk port compatibility with 2-wire loop
start or ground start. The paging frequency
response shall be 200 Hz to 8000 Hz, ±1 dB, and
the input/output impedance shall be 600 ohms,
nominal.
All operational modes require the unit to be sup-
plied with 24V DC @ 150 mA max draw. Reversal
of the power supply connection polarity will not
damage the unit. The unit shall be capable of gen-
erating an 800 Hz (± 20%), 1/2-second duration
signal to be used as a pre-announce or confirma-
tion tone; the tone level shall be controlled by an
adjustment that shall be accessible without
removing the cover.
When used in the station access mode, the
device shall be capable of three methods of
release following a page: (1) Loop Current
Interruption CPC Pulse, (2) Voice-Operated
Disconnect, and (3) Default Disconnect Timer.
The loop current interruption detection circuit
shall, if the particular line to which the device is
connected issues a disconnect signal (a loss of
loop current for longer than 30 milliseconds),
recognize this signal and immediately disconnect
the device from the line. The voice-operated
disconnect circuit shall be enabled/disabled via
mode switches or an external signal.
A default disconnect timer circuit shall set the
maximum time allotment for paging and ensure
that the unit will always disengage the line if the
other disconnect circuits are inoperative. The
default disconnect timer duration shall be
adjustable from 1 to 200 seconds and the VOX
disconnect timer duration shall be adjustable from
1 to 11 seconds. Time duration is controlled using
DIP switches and rotary controls. Both timers can
be independently inhibited.
When used in the trunk port access mode, the
device shall automatically terminate paging
access upon release of the trunk port.
A stereo combining RCA-type input shall be
included to accept a line-level input from a
suitable background music source. A control shall
be provided to set the background music volume.
One C-Form (N.O. and N.C.) set of contacts shall
be provided for use with auxiliary equipment. The
contacts shall be rated at 30V DC, 2A/125V AC,
0.6A /110V DC, 0.6A (resistive).
The device shall be mounted in a steel enclosure
and finished in black enamel with white lettering.
It shall be listed to UL standard 60950 and com-
ply with Part 68 of FCC Rules and Regulations.
The overall dimensions shall be 8-1/2" W x 1-3/4" H
x 3" D. The product weight shall be 2 lb.
Capable of wall-mount, single-unit rack mount (with
optional rack kit), or side-by-side dual-unit rack
mount.
Power supply is required for TAMB2, power supply
included with TAMB2PS
Technical
Specifications