Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8729 Multi-Conductor - Audio, Control and Instrumentation Cable For more Information please call 1-800-Belden1 General Description: 22 AWG stranded (19x34) tinned copper conductors, conductors cabled, polyethylene insulation, overall Beldfoil(R) shield (100% Coverage), 23 AWG and 25 AWG drain wires, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 4 22 19x34 TC - Tinned Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PE - Polyethylene 0.4064 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) (Z-Fold(R)) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: Component AWG Stranding Drain Wire Conductor Material Contains 3 23 Solid TCCS - Tinned Copper Covered Steel Contains 1 25 7x33 TCCS - Tinned Copper Covered Steel Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 1.2954 Overall Cable Overall Cabling Color Code Chart: Number Color 1 Black 2 Red 3 Green 4 Clear Overall Nominal Diameter: 6.528 mm Mechanical Characteristics (Overall) Operating Temperature Range: -40C To +75C UL Temperature Rating: 75C (UL AWM Style 2094) Bulk Cable Weight: 63.993 Kg/Km Max. Recommended Pulling Tension: 444.820 N Min. Bend Radius/Minor Axis: 69.850 mm Page 1 of 3 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8729 Multi-Conductor - Audio, Control and Instrumentation Cable Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CL3, CM CEC/C(UL) Specification: CM AWM Specification: UL Style 2094 (300 V 75C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 72.182 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 137.802 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 45.934 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 40.3563 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.3 Amps per conductor @ 25C Put Ups and Colors: Item # Putup Ship Weight Color 8729 009U1000 305 MT 20.412 KG WHITE Notes Item Desc 8729 009U500 152 MT 10.433 KG WHITE 8729 0091000 305 MT 21.319 KG WHITE C 4 #22 PE SHLD PVC 8729 009500 152 MT 10.659 KG WHITE C 4 #22 PE SHLD PVC 8729 0095000 1,524 MT 104.327 KG WHITE 4 #22 PE SHLD PVC 4 #22 PE SHLD PVC 4 #22 PE SHLD PVC Notes: C = CRATE REEL PUT-UP. Page 2 of 3 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8729 Multi-Conductor - Audio, Control and Instrumentation Cable Revision Number: 3 Revision Date: 08-03-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 08-21-2013