"ZNR" Transient/Surge Absorbers (Type D) "ZNR" Transient/Surge Absorbers Type: Series: D E "ZNR" Transient/Surge Absorber, Series E, Type D features large surge current and energy handling capability for absorbing transient overvoltage in a compact size. Features Large withstanding surge current capability in compact sizes "Energy Handling Capability" absorbing transient overvoltages in compact sizes Wide range of varistor voltages RoHS compliant Large Recommended Applications Transistor, diode, IC, thyristor or triac semiconductor protection protection in consumer electronic equipment Surge protection in communication, measuring or controller electronics Surge protection in electronic home appliances, gas or petroleum appliances Surge Applicable Standards UL1449 (VZCA2/UL, VZCA8/C-UL) IEC61051-1, -2, -2-2, IEC60950-1 Annex.Q CQC(GB/T10193, GB/T10194, GB4943.1, GB8898) Refer to pages 32 to 33, and 49 for the details VDE As for Handling Precautions and Minimum Quantity / Packing Unit Please see Related Information Explanation of Part Numbers 1 2 3 4 E R Z E 5 6 7 8 Series Series E5 Series E7 Series E8 Series E10 Series E11 Series E14 10 11 12 Design No. Product Code E05 E07 E08 E10 E11 E14 9 Lead Configuration Symbol Lead Configuration Packaging Bulk Straight Lead A 1) Bulk Crimped Lead B 2) Taped Straight Lead E 2) Taped Crimped Lead F Nominal Varistor Voltage The first two digits are significant figures and the third one denotes the number of zeros following. 1) Excluding E14, only the lead cut 2) Excluding E14 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 09 31 Apr. 2017 "ZNR" Transient/Surge Absorbers (Type D) Reference Guide to Standard Products Part No. Applicable Standards ERZE05A201 Type Name E201 ERZE07A201 Approvals Varistor Voltage at 1 mA (V) Maximum Allowable Voltage Clamping Voltage at 8/20s Maximum Peak Current at 8/20s(A) ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times 340 10 1200 E7201 340 25 2500 1250 ERZE08A201 E8201 340 25 3500 2500 ERZE10A201 E10201 340 50 4500 3000 ERZE11A201 E11201 340 50 6000 5000 ERZE14A201 E14201 340 100 10000 7000 ERZE05A221 E221 360 10 1200 360 25 2500 1250 360 25 3500 2500 360 50 4500 3500 200 (185 to 225) 130 170 600 600 ERZE07A221 E7221 ERZE08A221 E8221 ERZE10A221 E10221 ERZE11A221 E11221 360 50 6000 5000 ERZE14A221 E14221 360 100 10000 7000 220 (198 to 242) 140 180 ERZE05A241 E241 395 10 1200 ERZE07A241 E7241 395 25 2500 1250 ERZE08A241 E8241 395 25 3500 2500 ERZE10A241 E10241 395 50 4500 3000 ERZE11A241 E11241 395 50 6000 5000 ERZE14A241 E14241 395 100 10000 7000 ERZE05A271 E271 455 10 1200 240 (216 to 264) 150 200 600 ERZE07A271 E7271 455 25 2500 1250 E8271 455 25 3500 2500 ERZE10A271 E10271 455 50 4500 3000 ERZE11A271 E11271 455 50 6000 5000 ERZE14A271 E14271 455 100 10000 7000 ERZE05A331 E331 545 10 1200 545 25 2500 1250 545 25 3500 2500 545 50 4500 3000 175 225 ERZE07A331 E7331 ERZE08A331 E8331 ERZE10A331 E10331 ERZE11A331 E11331 545 50 6000 4500 ERZE14A331 E14331 545 100 10000 6500 210 270 ERZE05A361 E361 595 10 1200 ERZE07A361 E7361 595 25 2500 1250 ERZE08A361 E8361 595 25 3500 2500 ERZE10A361 E10361 595 50 4500 3000 ERZE11A361 E11361 595 50 6000 4500 ERZE14A361 E14361 595 100 10000 6500 360 (324 to 396) 230 300 600 ERZE05A391 E391 650 10 1200 ERZE07A391 E7391 650 25 2500 1250 ERZE08A391 E8391 650 25 3500 2500 ERZE10A391 E10391 650 50 4500 3000 ERZE11A391 E11391 650 50 6000 4500 ERZE14A391 E14391 650 100 10000 6500 390 (351 to 429) 250 320 E431 710 10 1200 ERZE07A431 E7431 710 25 2500 1250 ERZE08A431 E8431 710 25 3500 2500 ERZE10A431 E10431 710 50 4500 3000 ERZE11A431 E11431 710 50 6000 4500 ERZE14A431 E14431 710 100 10000 6500 275 350 AC 100 V to 120 V, Line-Line Applications Telephone Line Applications, (For DC 250 V Insulation Resistance Test) 600 ERZE05A431 430 (387 to 473) AC 100 V to 120 V, Line-Line Applications 600 330 (297 to 363) AC 100 V Line-Line Applications 600 ERZE08A271 270 (247 to 303) Recommended Applications 600 AC 100 V to 220 V, Line-Line and Line-Ground Applications : UL1449 (VZCA2/UL, VZCA8/C-UL), : VDE (IEC61051-1, -2, -2-2), : VDE (IEC60950-1 Annex.Q), : CQC (GB/T10193, GB/T10194), : CQC (GB4943.1, GB8898) Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 09 32 Apr. 2017 "ZNR" Transient/Surge Absorbers (Type D) Reference Guide to Standard Products Part No. Applicable Standards ERZE05A471 Type Name E471 ERZE07A471 Approvals Varistor Voltage at 1 mA (V) Maximum Allowable Voltage Clamping Voltage at 8/20s Maximum Peak Current at 8/20s(A) ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times 775 10 1200 E7471 775 25 2500 1250 ERZE08A471 E8471 775 25 3500 2500 ERZE10A471 E10471 775 50 4500 3000 ERZE11A471 E11471 775 50 6000 4500 ERZE14A471 E14471 775 100 10000 6500 ERZE07A511 E7511 845 25 2500 1250 ERZE08A511 E8511 845 25 3500 2500 ERZE10A511 E10511 845 50 4500 3000 ERZE11A511 E11511 845 50 6000 4500 ERZE14A511 E14511 845 100 10000 6500 ERZE07A561 E7561 930 25 2500 1250 ERZE08A561 E8561 930 25 3500 2500 ERZE10A561 E10561 930 50 4500 3000 ERZE11A561 E11561 930 50 6000 4500 ERZE14A561 E14561 930 100 10000 6500 ERZE07A621 E7621 1025 25 2500 1250 ERZE08A621 E8621 1025 25 3500 2500 ERZE10A621 E10621 1025 50 4500 3000 ERZE11A621 E11621 1025 50 5000 4500 ERZE14A621 E14621 1025 100 7500 6500 ERZE08A681 E8681 1120 25 3500 2500 ERZE10A681 ERZE11A681 ERZE14A681 E10681 E11681 E14681 1120 1120 1120 50 50 100 4500 3000 5000 4500 7500 6500 ERZE08A751 E8751 1240 25 3500 2500 ERZE10A751 E10751 1240 50 4500 3000 ERZE11A751 E11751 1240 50 5000 4500 ERZE14A751 E14751 1240 100 7500 6500 ERZE10A821 E10821 ERZE11A821 E11821 ERZE14A821 E14821 ERZE10A911 E10911 ERZE11A911 E11911 ERZE14A911 E14911 ERZE10A102 E10102 ERZE11A102 E11102 ERZE14A102 E14102 ERZE10A112 E10112 ERZE11A112 E11112 ERZE14A112 E14112 470 (423 to 517) 510 (459 to 561) 560 (504 to 616) 620 (558 to 682) 680 (612 to 748) 300 320 350 385 420 385 410 450 505 560 750 (675 to 825) 820 (738 to 902) 910 (819 to 1001) 1000 (900 to 1100) 1100 (990 to 1210) Recommended Applications 460 510 550 625 680 615 670 745 825 895 600 1355 50 4500 3000 1355 50 5000 4500 1355 100 7500 6500 1500 50 4500 3000 1500 50 5000 4500 1500 100 7500 6500 1650 50 4500 3000 1650 50 5000 4500 1650 100 7500 6500 1815 50 4500 3000 1815 50 5000 4500 1815 100 7500 6500 AC 100 V to 220 V, Line-Line and Line-Ground Applications AC 100 V to 240 V, Line-Line and Line-Ground Applications AC 380 V, Line-Line and Line-Ground Applications (For DC 500 V Insulating Test) AC 415 V, Line-Line and Line-Ground Applications (For DC 500 V Insulating Test) AC 480 V, Line-Line and Line-Ground Applications (For DC 500 V Insulating Test) : UL1449 (VZCA2/UL, VZCA8/C-UL), : VDE (IEC61051-1, -2, -2-2), : VDE (IEC60950-1 Annex.Q), : CQC (GB/T10193, GB/T10194), : CQC (GB4943.1, GB8898) Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 09 33 Apr. 2017 "ZNR" Transient/Surge Absorbers (Type D) Series E5 Ratings and Characteristics Operating Temperature Range : -40 to 85 C Part No. Maximum Allowable Voltage Varistor Voltage V1 mA (V) Storage Temperature Range : -40 to 125 C Clamping Voltage (max.) Ip Rated Power Maximum Peak Current Capacitance (8/20 s) (max.) (10/1000 s) (2 ms) 1 time 2 times Maximum Energy ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE05A201 200(185 to 225) 130 170 340 0.25 13 9.5 1200 600 200 ERZE05A221 220(198 to 242) 140 180 360 0.25 14 10 1200 600 190 ERZE05A241 240(216 to 264) 150 200 395 0.25 15 11 1200 600 170 ERZE05A271 270(247 to 303) 175 225 455 0.25 18 13 1200 600 150 ERZE05A331 330(297 to 363) 210 270 545 0.25 21 15 1200 600 130 ERZE05A361 360(324 to 396) 230 300 595 0.25 23 17 1200 600 130 ERZE05A391 390(351 to 429) 250 320 650 0.25 26 19 1200 600 130 ERZE05A431 430(387 to 473) 275 350 710 0.25 29 21 1200 600 120 ERZE05A471 470(423 to 517) 300 385 775 0.25 32 23 1200 600 100 Ip Measuring current of clamping voltage : 10 A Dimensions in mm (not to scale) F1.0 A max. L1.0 ERZE05A201 7.0 4.8 5.0 10.0 2.1 ERZE05A221 7.0 4.9 5.0 10.0 2.3 ERZE05A241 7.0 5.0 5.0 10.0 2.4 ERZE05A271 7.0 5.2 5.0 10.0 2.5 ERZE05A331 7.0 5.5 5.0 10.0 2.9 ERZE05A361 7.0 5.8 5.0 10.0 3.1 ERZE05A391 7.0 5.9 5.0 10.0 3.2 ERZE05A431 7.0 6.1 5.0 10.0 3.3 ERZE05A471 7.0 6.3 5.0 10.0 3.5 D T L F f 0.6 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 34 L T max. A D max. 20.0 min. Part No. F Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE05A201 to ERZE05A471 ERZE05A201 to ERZE05A471 10000 2000 Max. Clamping Voltage Max. Leakage Current 471 431 391 361 331 271 241 221 201 471 431 391 361 1000 1 Ti Impulse Current (A) Voltage (V) 300 271 241 10 Ti 10 3 mes 10 4 Tim Tim es 10 2 Ti e m 10 5 s es Tim es 10 10 6 Tim es 100 es m 400 e 2 500 200 m Ti 1000 900 800 700 600 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval 201 100 90 80 70 60 50 331 221 1 Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 40 30 10-6 10-5 10-4 10-3 10-2 10-1 100 Current (A) 101 102 103 104 105 0.1 20 100 1000 10000 Impulse Width (s) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 35 Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Series E7 Ratings and Characteristics Operating Temperature Range : -40 to 85 C Part No. Maximum Allowable Voltage Varistor Voltage V1 mA (V) Storage Temperature Range : -40 to 125 C Clamping Voltage (max.) Ip Rated Power Maximum Peak Current Capacitance (8/20 s) (max.) (10/1000 s) (2 ms) 1 time 2 times Maximum Energy ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE07A201 200(185 to 225) 130 170 340 0.3 26 19 2500 1250 360 ERZE07A221 220(198 to 242) 140 180 360 0.3 30 22 2500 1250 350 ERZE07A241 240(216 to 264) 150 200 395 0.3 33 24 2500 1250 340 ERZE07A271 270(247 to 303) 175 225 455 0.3 39 28 2500 1250 310 ERZE07A331 330(297 to 363) 210 270 545 0.3 44 32 2500 1250 280 ERZE07A361 360(324 to 396) 230 300 595 0.3 50 36 2500 1250 260 ERZE07A391 390(351 to 429) 250 320 650 0.3 53 38 2500 1250 240 ERZE07A431 430(387 to 473) 275 350 710 0.3 60 43 2500 1250 210 ERZE07A471 470(423 to 517) 300 385 775 0.3 65 47 2500 1250 170 ERZE07A511 510(459 to 561) 320 410 845 0.3 70 50 2500 1250 140 ERZE07A561 560(504 to 616) 350 450 930 0.3 75 55 2500 1250 140 ERZE07A621 620(558 to 682) 385 505 1025 0.3 80 60 2500 1250 135 Ip Measuring current of clamping voltage : 25 A Dimensions in mm (not to scale) F1.0 A max. L1.0 ERZE07A201 9.0 5.3 7.5 12.5 2.1 ERZE07A221 9.0 5.4 7.5 12.5 2.3 ERZE07A241 9.0 5.5 7.5 12.5 2.4 ERZE07A271 9.0 5.7 7.5 12.5 2.5 ERZE07A331 9.0 6.0 7.5 12.5 2.8 ERZE07A361 9.0 6.2 7.5 12.5 2.9 ERZE07A391 9.0 6.3 7.5 12.5 3.0 ERZE07A431 9.0 6.5 7.5 12.5 3.1 ERZE07A471 9.0 6.8 7.5 12.5 3.3 ERZE07A511 9.0 7.0 7.5 12.5 3.5 ERZE07A561 9.0 7.4 7.5 13.5 3.8 ERZE07A621 10.0 7.8 7.5 13.5 4.0 D T L F f 0.8 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 36 L T max. A D max. 20.0 min. Part No. F Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE07A201 to ERZE07A621 ERZE07A201 to ERZE07A621 10000 561 511 471 431 391 361 Tim es Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 40 30 10-6 s 10 331 221 e im 10 6 e 100 10 4 10 5 Tim Tim es es 201 100 90 80 70 60 50 2T 271 241 200 Tim 300 1 400 es es im es Tim 02 T 3 Tim 1 0 1 621 500 Voltage (V) 1000 10 1000 900 800 700 600 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval 621 561 511 471 431 391 361 331 271 241 221 201 Surge Current (A) 2000 Max. Clamping Voltage Max. Leakage Current 10-5 10-4 10-3 10-2 10-1 100 101 102 103 Current (A) 104 105 1 20 100 1000 Impulse Width (s) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 37 10000 Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Series E8 Ratings and Characteristics Operating Temperature Range : -40 to 85 C Part No. Maximum Allowable Voltage Varistor Voltage V1 mA (V) Storage Temperature Range : -40 to 125 C Clamping Voltage (max.) Ip Rated Power Maximum Peak Current Capacitance (8/20 s) (max.) (10/1000 s) (2 ms) 1 time 2 times Maximum Energy ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE08A201 200(185 to 225) 130 170 340 0.4 35 25 3500 2500 390 ERZE08A221 220(198 to 242) 140 180 360 0.4 39 27.5 3500 2500 380 ERZE08A241 240(216 to 264) 150 200 395 0.4 42 30 3500 2500 360 ERZE08A271 270(247 to 303) 175 225 455 0.4 49 35 3500 2500 330 ERZE08A331 330(297 to 363) 210 270 545 0.4 58 42 3500 2500 300 ERZE08A361 360(324 to 396) 230 300 595 0.4 65 45 3500 2500 280 ERZE08A391 390(351 to 429) 250 320 650 0.4 70 50 3500 2500 260 ERZE08A431 430(387 to 473) 275 350 710 0.4 80 55 3500 2500 230 ERZE08A471 470(423 to 517) 300 385 775 0.4 85 60 3500 2500 180 ERZE08A511 510(459 to 561) 320 410 845 0.4 92 67 3500 2500 150 ERZE08A561 560(504 to 616) 350 450 930 0.4 92 67 3500 2500 150 ERZE08A621 620(558 to 682) 385 505 1025 0.4 92 67 3500 2500 140 ERZE08A681 680(612 to 748) 420 560 1120 0.4 92 67 3500 2500 130 ERZE08A751 750(675 to 825) 460 615 1240 0.4 100 70 3500 2500 130 Ip Measuring current of clamping voltage : 25 A Dimensions in mm (not to scale) F1.0 A max. L1.0 ERZE08A201 10.5 5.1 7.5 13.5 1.9 ERZE08A221 10.5 5.2 7.5 13.5 2.0 ERZE08A241 10.5 5.3 7.5 13.5 2.1 ERZE08A271 10.5 5.5 7.5 13.5 2.3 ERZE08A331 10.5 5.9 7.5 13.5 2.6 ERZE08A361 10.5 6.1 7.5 13.5 2.8 ERZE08A391 10.5 6.3 7.5 13.5 2.9 ERZE08A431 10.5 6.5 7.5 13.5 3.1 ERZE08A471 10.5 7.3 7.5 13.5 3.6 ERZE08A511 10.5 7.8 7.5 13.5 4.0 ERZE08A561 10.5 8.1 7.5 13.5 4.3 ERZE08A621 11.5 8.7 7.5 14.5 4.7 ERZE08A681 11.5 9.0 7.5 14.5 5.0 ERZE08A751 11.5 9.7 7.5 14.5 5.6 D T L F f 0.8 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 38 L T max. A D max. 20.0 min. Part No. F Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE08A201 to ERZE08A511 ERZE08A201 to ERZE08A511 10000 2000 Max. Leakage Current 511 471 431 391 361 331 271 241 221 201 1000 Voltage (V) Surge Current (A) 241 201 100 90 80 70 60 50 10 6 331 221 Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 10-5 10-4 10-3 10-2 10-1 100 Current (A) 101 102 103 104 ERZE08A561 to ERZE08A751 1 20 105 100 1000 Impulse Width (s) 10000 Max. Clamping Voltage Max. Leakage Current 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval 3000 1000 2000 751 681 621 561 10 Surge Current (A) 10 100 e im 1 T imes 2T es s Tim ime 3 T 10 700 2 10 1000 900 800 es Tim Voltage (V) 10000 ERZE08A561 to ERZE08A751 5000 4000 Tim es 10 40 30 10-6 e im 271 4 Ti m e 10 5 s Tim es 100 300 200 10 es im 511 1T 400 2T 500 s es es m ime Tim 2 Ti 3 T 10 10 471 431 391 361 10 1000 900 800 700 600 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval Max. Clamping Voltage 4 Ti 10 5 mes Tim es 600 500 400 300 200 10-6 10 1 56 751 681 621 10-5 10 6 Tim es Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 10-4 10-3 10-2 10-1 100 Current (A) 101 103 102 104 105 1 20 100 1000 Impulse Width (s) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 39 10000 Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Series E10 Ratings and Characteristics Operating Temperature Range : -40 to 85 C Part No. Maximum Allowable Voltage Varistor Voltage Storage Temperature Range : -40 to 125 C Clamping Voltage (max.) Ip Rated Power Maximum Peak Current Capacitance (8/20 s) (max.) (10/1000 s) (2 ms) 1 time 2 times Maximum Energy V1 mA (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE10A201 200(185 to 225) 130 170 340 0.5 47 34 4500 3000 630 ERZE10A221 220(198 to 242) 140 180 360 0.5 50 36 4500 3000 600 ERZE10A241 240(216 to 264) 150 200 395 0.5 56 40 4500 3000 570 ERZE10A271 270(247 to 303) 175 225 455 0.5 64 46 4500 3000 530 ERZE10A331 330(297 to 363) 210 270 545 0.5 72 52 4500 3000 470 ERZE10A361 360(324 to 396) 230 300 595 0.5 84 60 4500 3000 430 ERZE10A391 390(351 to 429) 250 320 650 0.5 91 65 4500 3000 400 ERZE10A431 430(387 to 473) 275 350 710 0.5 99 71 4500 3000 350 ERZE10A471 470(423 to 517) 300 385 775 0.5 106 76 4500 3000 320 ERZE10A511 510(459 to 561) 320 410 845 0.5 117 84 4500 3000 300 ERZE10A561 560(504 to 616) 350 450 930 0.5 120 86 4500 3000 290 ERZE10A621 620(558 to 682) 385 505 1025 0.5 126 88 4500 3000 280 ERZE10A681 680(612 to 748) 420 560 1120 0.5 133 95 4500 3000 260 ERZE10A751 750(675 to 825) 460 615 1240 0.5 140 100 4500 3000 250 ERZE10A821 820(738 to 902) 510 670 1355 0.5 154 110 4500 3000 230 ERZE10A911 910(819 to 1001) 550 745 1500 0.5 168 112 4500 3000 220 ERZE10A102 1000(900 to 1100) 625 825 1650 0.5 182 130 4500 3000 200 ERZE10A112 1100(990 to 1210) 680 895 1815 0.5 196 140 4500 3000 180 Ip Measuring current of clamping voltage : 50 A Dimensions in mm (not to scale) F1.0 A max. L1.0 ERZE10A201 11.5 5.3 7.5 15.0 2.1 ERZE10A221 11.5 5.4 7.5 15.0 2.3 ERZE10A241 11.5 5.5 7.5 15.0 2.4 ERZE10A271 11.5 5.7 7.5 15.0 2.5 ERZE10A331 11.5 6.0 7.5 15.0 2.8 ERZE10A361 11.5 6.2 7.5 15.0 2.9 ERZE10A391 11.5 6.3 7.5 15.0 3.0 ERZE10A431 11.5 6.5 7.5 15.0 3.1 ERZE10A471 11.5 6.8 7.5 15.0 3.3 ERZE10A511 11.5 7.0 7.5 15.0 3.5 ERZE10A561 11.5 7.4 7.5 15.0 3.8 ERZE10A621 12.5 7.8 7.5 16.0 4.0 ERZE10A681 12.5 8.1 7.5 16.0 4.2 ERZE10A751 12.5 8.6 7.5 16.0 4.6 ERZE10A821 12.5 8.9 7.5 16.0 5.0 ERZE10A911 12.5 9.5 7.5 16.0 5.7 ERZE10A102 12.5 10.0 7.5 16.0 6.2 ERZE10A112 12.5 10.6 7.5 16.0 6.8 D T L F f 0.8 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 40 L T max. A D max. 20.0 min. Part No. F Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE10A201 to ERZE10A561 ERZE10A201 to ERZE10A561 10000 2000 Max. Leakage Current 561 511 471 431 391 361 331 271 241 221 201 511 471 431 391 361 1000 10 Voltage (V) Surge Current (A) Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 10-5 10-4 10-3 10-2 10-1 100 Current (A) 101 102 103 104 1 20 105 100 1000 Impulse Width (s) 10000 Max. Clamping Voltage Max. Leakage Current 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval 112 102 911 821 751 681 621 3000 1000 10 1T 2 10 es Tim 2000 Ti m 10 5 es Tim es es im 2T Surge Current (A) e es 4 m Ti 2 im 3 10 100 11 es 10 102 911 821 Tim Voltage (V) 10000 ERZE10A621 to ERZE10A112 5000 1000 900 800 Tim es 10 331 221 ERZE10A621 to ERZE10A112 4000 es im 10 6 40 30 10-6 2T 201 100 90 80 70 60 50 e im 4 Ti m 10 5 es Tim es 100 271 241 Ti 10 1T 3 561 300 200 10 500 400 es es Tim 2 Tim es m 10 1000 900 800 700 600 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval Max. Clamping Voltage 700 600 10 6 500 10 Tim es 400 300 200 10-6 Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 751 681 621 10-5 10-4 10-3 10-2 10-1 100 Current (A) 101 102 103 104 105 1 20 100 1000 Impulse Width (s) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 41 10000 Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Series E11 Ratings and Characteristics Operating Temperature Range : -40 to 85 C Part No. Maximum Allowable Voltage Varistor Voltage Storage Temperature Range : -40 to 125 C Clamping Voltage (max.) Ip Rated Power Maximum Peak Current Capacitance (8/20 s) (max.) (10/1000 s) (2 ms) 1 time 2 times Maximum Energy V1 mA (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE11A201 200(185 to 225) 130 170 340 0.6 70 50 6000 5000 690 ERZE11A221 220(198 to 242) 140 180 360 0.6 78 55 6000 5000 660 ERZE11A241 240(216 to 264) 150 200 395 0.6 84 60 6000 5000 620 ERZE11A271 270(247 to 303) 175 225 455 0.6 99 70 6000 5000 580 ERZE11A331 330(297 to 363) 210 270 545 0.6 115 80 6000 4500 520 ERZE11A361 360(324 to 396) 230 300 595 0.6 130 90 6000 4500 480 ERZE11A391 390(351 to 429) 250 320 650 0.6 140 100 6000 4500 450 ERZE11A431 430(387 to 473) 275 350 710 0.6 155 110 6000 4500 400 ERZE11A471 470(423 to 517) 300 385 775 0.6 175 125 6000 4500 360 ERZE11A511 510(459 to 561) 320 410 845 0.6 190 136 6000 4500 310 ERZE11A561 560(504 to 616) 350 450 930 0.6 190 136 6000 4500 310 ERZE11A621 620(558 to 682) 385 505 1025 0.6 190 136 5000 4500 300 ERZE11A681 680(612 to 748) 420 560 1120 0.6 190 136 5000 4500 290 ERZE11A751 750(675 to 825) 460 615 1240 0.6 210 150 5000 4500 280 ERZE11A821 820(738 to 902) 510 670 1355 0.6 235 165 5000 4500 260 ERZE11A911 910(819 to 1001) 550 745 1500 0.6 255 180 5000 4500 240 ERZE11A102 1000(900 to 1100) 625 825 1650 0.6 280 200 5000 4500 220 ERZE11A112 1100(990 to 1210) 680 895 1815 0.6 310 220 5000 4500 200 Ip Measuring current of clamping voltage : 50 A Dimensions in mm (not to scale) F1.0 A max. L1.0 ERZE11A201 13.0 5.2 7.5 17.0 1.9 ERZE11A221 13.0 5.3 7.5 17.0 2.0 ERZE11A241 13.0 5.4 7.5 17.0 2.1 ERZE11A271 13.0 5.6 7.5 17.0 2.3 ERZE11A331 13.0 5.9 7.5 17.0 2.6 ERZE11A361 13.0 6.1 7.5 17.0 2.8 ERZE11A391 13.0 6.2 7.5 17.0 2.9 ERZE11A431 13.0 6.4 7.5 17.0 3.1 ERZE11A471 13.0 6.6 7.5 17.0 3.3 ERZE11A511 13.0 6.8 7.5 17.0 3.5 ERZE11A561 13.0 7.2 7.5 17.0 3.8 ERZE11A621 14.0 7.5 7.5 18.0 4.2 ERZE11A681 14.0 7.8 7.5 18.0 4.5 ERZE11A751 14.0 8.2 7.5 18.0 4.9 ERZE11A821 14.0 8.5 7.5 18.0 5.2 ERZE11A911 14.0 9.0 7.5 18.0 5.7 ERZE11A102 14.0 9.5 7.5 18.0 6.2 ERZE11A112 14.0 10.1 7.5 18.0 6.8 D T L F f 0.8 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 42 L T max. A D max. 20.0 min. Part No. F Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE11A201 to ERZE11A511 ERZE11A201 to ERZE11A511 10000 2000 Max. Leakage Current 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval 511 471 431 391 361 331 271 241 221 201 471 431 391 361 1000 3 10 Surge Current (A) Voltage (V) 300 200 271 241 10 4 10 5 100 10 6 Ti 10 511 es m Ti 500 400 e im 1 T ime es es Tim im 2 T 10 2T 1000 900 800 700 600 Max. Clamping Voltage m es Tim es Tim es 201 100 90 80 70 60 50 331 221 10 Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 40 30 10-6 10-5 10-4 10-3 10-2 10-1 100 Current (A) 101 102 103 104 ERZE11A561 to ERZE11A112 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval 112 102 911 821 751 681 621 561 es Surge Current (A) e es es Tim 10 6 es 2 Ti Tim es 4 m 100 im 10 10 m Ti 10 im 2T 3 2 11 10 102 911 821 1000 1T 2000 Voltage (V) 10000 10000 Max. Clamping Voltage Max. Leakage Current 3000 1000 900 800 100 1000 Impulse Width (s) ERZE11A561 to ERZE11A112 5000 4000 1 20 105 Tim es 700 600 500 10 400 61 5 300 200 10-6 Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 751 681 621 10-5 10-4 10-3 10-2 10-1 100 Current (A) 101 102 103 104 105 1 20 100 1000 Impulse Width (s) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 43 10000 Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Series E14 Ratings and Characteristics Operating Temperature Range : -40 to 85 C Part No. V1 mA (V) ACrms (V) Storage Temperature Range : -40 to 125 C Maximum Peak Current Capacitance (8/20 s) (max.) (10/1000 s) (2 ms) 1 time 2 times Clamping Voltage (max.) Ip Rated Power DC (V) (V) (W) (J) (J) Maximum Allowable Voltage Varistor Voltage Maximum Energy (A) (A) at 1 kHz (pF) ERZE14A201 200(185 to 225) 130 170 340 1.0 140 100 10000 7000 1300 ERZE14A221 220(198 to 242) 140 180 360 1.0 155 110 10000 7000 1200 ERZE14A241 240(216 to 264) 150 200 395 1.0 168 120 10000 7000 1100 ERZE14A271 270(247 to 303) 175 225 455 1.0 190 135 10000 7000 1000 ERZE14A331 330(297 to 363) 210 270 545 1.0 228 160 10000 6500 900 ERZE14A361 360(324 to 396) 230 300 595 1.0 255 180 10000 6500 900 ERZE14A391 390(351 to 429) 250 320 650 1.0 275 195 10000 6500 800 ERZE14A431 430(387 to 473) 275 350 710 1.0 303 215 10000 6500 800 ERZE14A471 470(423 to 517) 300 385 775 1.0 350 250 10000 6500 750 ERZE14A511 510(459 to 561) 320 410 845 1.0 382 273 10000 6500 700 ERZE14A561 560(504 to 616) 350 450 930 1.0 382 273 10000 6500 700 ERZE14A621 620(558 to 682) 385 505 1025 1.0 382 273 7500 6500 650 ERZE14A681 680(612 to 748) 420 560 1120 1.0 382 273 7500 6500 600 ERZE14A751 750(675 to 825) 460 615 1240 1.0 420 300 7500 6500 530 ERZE14A821 820(738 to 902) 510 670 1355 1.0 460 325 7500 6500 500 ERZE14A911 910(819 to 1001) 550 745 1500 1.0 510 360 7500 6500 400 ERZE14A102 1000(900 to 1100) 625 825 1650 1.0 565 400 7500 6500 400 ERZE14A112 1100(990 to 1210) 680 895 1815 1.0 620 440 7500 6500 350 Ip Measuring current of clamping voltage : 100 A Dimensions in mm (not to scale) F1.0 A max. L1.0 ERZE14A201 16.5 5.2 10.0 20.0 2.1 ERZE14A221 16.5 5.3 10.0 20.0 2.2 ERZE14A241 16.5 5.4 10.0 20.0 2.3 ERZE14A271 16.5 5.6 10.0 20.0 2.5 ERZE14A331 16.5 5.9 10.0 20.0 2.8 ERZE14A361 16.5 6.1 10.0 20.0 3.0 ERZE14A391 16.5 6.2 10.0 20.0 3.1 ERZE14A431 16.5 6.4 10.0 20.0 3.3 ERZE14A471 16.5 6.6 10.0 20.0 3.5 ERZE14A511 16.5 6.8 10.0 20.0 3.7 ERZE14A561 16.5 7.2 10.0 20.0 4.0 ERZE14A621 17.5 7.5 10.0 20.5 4.4 ERZE14A681 17.5 7.8 10.0 20.5 4.7 ERZE14A751 17.5 8.2 10.0 20.5 5.1 ERZE14A821 17.5 8.5 10.0 20.5 5.4 ERZE14A911 17.5 9.0 10.0 20.5 5.9 ERZE14A102 17.5 9.5 10.0 20.5 6.4 ERZE14A112 17.5 10.1 10.0 20.5 7.2 D T L F f 1.0 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 44 L T max. A D max. 20.0 min. Part No. F Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE14A201 to ERZE14A511 ERZE14A201 to ERZE14A511 10000 2000 Max. Leakage Current 511 471 431 391 361 331 471 431 391 361 Surge Current (A) Voltage (V) 300 200 271 3 511 10 500 400 e im e 1T es Tim 2 es Tim 10 2 Tim mes Ti 1000 271 241 221 201 10 1000 900 800 700 600 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval Max. Clamping Voltage 10 100 10 5 10 6 4 Ti m es Tim es Tim es 201 100 90 80 70 60 50 10 241 331 221 Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 40 30 10-6 10-5 10-4 10-3 10-2 10-1 100 Current (A) 101 102 103 104 ERZE14A561 to ERZE14A112 2 times : 5 min. interval up to 10 times : 2 min. interval up to 106 times : 10 sec. interval 2T 10 10 100 Ti Surge Current (A) 2 es s e Tim mes es im 4 T Tim 3 2 11 10 102 911 821 10 Voltage (V) 1T 1000 e im e im 112 102 911 821 751 681 621 561 2000 700 10000 10000 Max. Clamping Voltage Max. Leakage Current 3000 1000 900 800 100 1000 Impulse Width (s) ERZE14A561 to ERZE14A112 5000 4000 1 20 105 10 5 T 10 6 im e Tim s es 600 500 10 400 300 200 10-6 1 56 751 681 621 10-5 Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 s 10-4 10-3 10-2 10-1 100 Current (A) 101 102 103 104 105 1 20 100 1000 10000 Impulse Width (s) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 45 Jan. 2015 "ZNR" Transient/Surge Absorbers (Type D) Straight Leads Cut Type (Bulk Type) Ratings and Characteristics Refer to bulk standard type part no. (P34 to P43). Dimensions in mm (not to scale) T B A D fd L F Dimension "L": Conforms to each individtual specification. Dimension "T": Conforms to each individual specification. notes Unit : mm Series Symbol Varistor Voltage D A F fd B Standard Products Part No. E5 E7 E8 E10 E11 201 to 471 201 to 511 561 621 201 to 561 621 to 751 201 to 561 621 to 112 201 to 561 621 to 112 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 13.0 max. 14.0 max. 10.0 max. 12.5 max. 13.5 max. 13.5 max. 13.5 max. 14.5 max. 15.0 max. 16.0 max. 17.0 max. 18.0 max. 5.01.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 0.60+0.06 0.80+0.08 0.80+0.08 0.80+0.08 0.80+0.08 0.80+0.08 0.80+0.08 0.80+0.08 0.80+0.08 0.80+0.08 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 ERZE05ACS ERZE07ACS ERZE08ACS ERZE10ACS ERZE11ACS Crimped Leads Cut Type (Bulk Type) Ratings and Characteristics Refer to bulk standard type part no. (P34 to P43). Dimensions in mm (not to scale) T A D C C fd F B L Dimension "L": Conforms to each individual specification. Dimension "T": Conforms to each individual specification. Resin extenyions : No resin below the center of the hook. notes Unit : mm Series Symbol Varistor Voltage D A C F fd B Standard Products Part No. E5 E7 E8 E10 E11 201 to 471 201 to 511 561 621 201 to 561 621 to 751 201 to 561 621 to 681 751 to 112 201 to 561 621 to 112 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 12.5 max. 13.0 max. 14.0 max. 13.0 max. 15.5 max. 16.5 max. 16.5 max. 17.0 max. 18.0 max. 18.0 max. 19.5 max. 20.5 max. 20.5 max. 21.5 max. 1.20.4 1.40.4 1.40.4 1.40.4 1.40.4 1.40.4 1.40.4 1.40.4 1.40.4 1.40.4 1.40.4 5.01.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 7.51.0 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 0.60+0.06 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 4.01.0 ERZE05BCS ERZE07BCS ERZE08BCS ERZE10BCS ERZE11BCS Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 05 46 Apr. 2017 "ZNR" Transient/Surge Absorbers (Type D) Taping Specifications for Automated Assembly (Straight Leads and Taping) Ratings and Characteristics Refer to bulk standard type part no. (P34 to P43). Taping Dimensions in mm (not to scale) P2 h fD P A T F1 H0 H W W1 L W0 W2 P1 F fd f D0 t P0 Position of H0 dimension Position of F1 dimension Dimension "T": Conforms to each individual specification. Unit : mm E5 E7 E8 E10 E11 Varistor Voltage 201 to 471 201 to 271 331 to 551 561 621 201 to 221 241 to 561 621 to 751 201 to 221 241 to 561 621 to 112 201 to 221 241 to 561 621 to 112 P 12.71.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 P0 12.70.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 P1 3.850.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 P2 6.361.30 7.51.37.51.37.51.37.51.37.51.37.51.37.51.37.51.37.51.37.51.37.51.37.51.37.51.3 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 0.60+0.06 fd -0.05 0.80-0.05 0.80-0.05 0.80-0.05 0.80-0.05 0.80-0.05 0.80 -0.05 0.80-0.05 0.80-0.05 0.80-0.05 0.80-0.05 0.80-0.05 0.80-0.05 0.80-0.05 F 5.00.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 h 02 02 02 02 02 02 02 02 02 02 02 02 02 02 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 W 18.0+1.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. W1 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 W2 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. H Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 H0 17.00.5 18.0+2.0 ---- ---- ---- 18.0+2.0 ---- ---- 18.0+2.0 ---- ---- 18.0+2.0 ---- ---- 0 0 0 0 +0.75 +0.75 +0.75 +0.75 +0.75 +0.75 +0.75 F1 ---- ---- 16.00 -0.50 16.00 -0.50 16.00 -0.50 ---- 16.00 -0.50 16.00 -0.50 ---- 16.00 -0.50 16.00+0.75 ---- 16.00+0.75 -0.50 -0.50 16.00 -0.50 fD0 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 t 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 L 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 7.0 max. 9.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 10.5 max. 11.5 max. 11.5 max. 11.5 max. 12.5 max. 13.0 max. 13.0 max. 14.0 max. fD A 10.0 max. 12.5 max. 12.5 max. 13.5 max. 13.5 max. 13.5 max. 13.5 max. 14.5 max. 15.0 max. 15.0 max. 16.0 max. 17.0 max. 17.0 max. 18.0 max. Series Symbol Standard Products Part No. ERZE05E ERZE07E ERZE08E ERZE10E ERZE11E Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 05 47 Apr. 2017 "ZNR" Transient/Surge Absorbers (Type D) Taping Specifications for Automated Assembly (Crimped Leads and Taping) Ratings and Characteristics Refer to bulk standard type part no. (P34 to P43). Taping Dimensions in mm (not to scale) P2 h fD P H W W1 L W0 P1 H0 W2 A T F fd f D0 t P0 Dimension "T": Conforms to each individual specification. Unit : mm E5 E7 E8 E10 E11 Varistor Voltage 201 to 471 201 to 511 561 621 201 to 221 241 to 561 621 to 751 201 to 561 621 to 681 751 to 112 201 to 221 241 to 561 621 to 112 P 12.71.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 15.01.0 P0 12.70.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 15.00.3 P1 3.850.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 3.750.70 P2 6.351.30 7.51.3 7.51.3 7.51.3 7.51.3 7.51.3 7.51.3 7.51.3 7.51.3 7.51.3 7.51.3 7.51.3 7.51.3 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 0.60+0.06 fd -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 0.80 -0.05 F 5.00.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 7.50.5 h 02 02 02 02 02 02 02 02 02 02 02 02 02 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 W 18.0+1.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 18.0 -0.5 W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. W1 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 9.00.5 W2 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. H Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 H0 17.00.5 16.00.5 16.00.5 16.00.5 16.00.5 16.00.5 16.00.5 16.00.5 16.00.5 16.00.5 16.00.5 16.00.5 16.00.5 fD0 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 f 4.00.2 t 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 0.60.3 L 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 12.5 max. 13.0 max. 13.0 max. 14.0 max. fD A 13.0 max. 15.5 max. 16.5 max. 16.5 max. 17.0 max. 17.0 max. 18.0 max. 18.0 max. 19.5 max. 20.5 max. 20.5 max. 20.5 max. 21.5 max. Series Symbol Standard Products Part No. ERZE05F ERZE07F ERZE08F ERZE10F ERZE11F Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 05 48 Apr. 2017 "ZNR" Transient/Surge Absorbers (Type D) Application Note for Safety Standards (For Series E) Approvals products lists in "Reference Guide to Standard Products" and VDE : Registered in "Type Name" , it isn't registered in "Panasonic Part No." CQC : Registered in "Panasonic Part No." "Rated Voltages" are specified for UL recognized components in list shown below. UL The AC Rated Voltage and Maximum Allowable Voltage Maximum Allowable Voltage Rated Voltage (Vrms) Type Name E201 E221 E241 E271 E331 E361 E391 E431 E471 E511 E561 E621 E681 E751 E821 E911 E102 E112 ACrms (V) DC (V) UL1449 130 140 150 175 210 230 250 275 300 320 350 385 420 460 510 550 625 680 170 180 200 225 270 300 320 350 385 410 450 505 560 615 670 745 825 895 118 127 136 159 189 209 227 250 272 291 320 350 381 418 463 500 568 600 : 5 series is blank, 7 series is 7, 8 series is 8, 10 series is 10, 11 series is 11, 14 series is 14 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 03 49 Jan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