Series 2600B System SourceMeter(R) SMU Instruments * Family of models offer industry's widest dynamic range: 10A pulse to 0.1fA and 200V to 100nV * Built-in, Java-based test software enables true plug & play I/V characterization and test through any browser. * TSP (Test Script Processing) technology embeds complete test programs inside the instrument for best-in-class system-level throughput * TSP-Link expansion technology for multi-channel parallel test without a mainframe * Software emulation for Keithley's Model 2400 SourceMeter SMU Instrument * USB 2.0, LXI-C, GPIB, RS-232, and digital I/O interfaces * Free software drivers and development/debug tools * Optional ACS-Basic semiconductor component characterization software The Series 2600B System SourceMeter SMU Instruments are the industry's leading current/voltage source and measure solutions, and are built from Keithley's third generation SMU technology. The Series 2600B offers single- and dual-channel models that combine the capabilities of a precision power supply, true current source, 61/2-digit DMM, arbitrary waveform generator, pulse generator, and electronic load - all into one tightly integrated instrument. The result is a powerful solution that significantly boosts productivity in applications ranging from bench-top I-V characterization through highly automated production test. For bench-top use, Series 2600B SMU instruments feature builtin, Java-based software that enables plug & play I-V testing through any browser, on any computer, from anywhere in the world. For automated system applications, the Series 2600B's Test Script Processor (TSP(R)) runs complete test programs from inside the instrument for industry-best throughput. In larger, multi-channel applications, Keithley's TSP-Link(R) Technology works together with TSP Technology to enable high-speed, SMU-per-pin parallel testing. Because Series 2600B SourceMeter SMU Instruments have fully isolated channels that do not require a mainframe, they can be easily reconfigured and re-deployed as your test applications evolve. Java-based Plug & Play I-V Test Software The Series 2600B are the only SMU instruments to feature built-in, Java-based test software that enables true plug & play I-V characterization through any browser, on any computer, from anywhere in the world. This unique capability boosts productivity across a wide range of applications such as R&D, education, QA/FA, and more. Simply connect the 2600B to the internet via the supplied LAN cable, open a browser, type in the 2600B's I.P. address, and begin testing. Resulting data can be downloaded to a spreadsheet such as Excel for further analysis and formatting, or for inclusion in other documents or presentations. SMU INSTRUMENTS Built-in, Java-based test software runs directly from any web browser to boost productivity. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Scalable, integrated source and measure solutions Scalable, integrated source and measure solutions * Tightly integrated, 4-quadrant voltage/current source and measure instruments offer best in class performance with 61/2-digit resolution Scalable, integrated source and measure solutions 2601B Single-channel System SourceMeter SMU Instrument (3A DC, 10A Pulse) 2602B Dual-channel System SourceMeter SMU Instrument (3A DC, 10A Pulse) 2604B Dual-channel System SourceMeter SMU Instrument (3A DC, 10A Pulse, Benchtop Version) 2611B Single-channel System SourceMeter SMU Instrument (200V, 10A Pulse) 2612B Dual-channel System SourceMeter SMU Instrument (200V, 10A Pulse) 2614B Dual-channel System SourceMeter SMU Instrument (200V, 10A Pulse, Benchtop Version) 2634B Dual-channel System SourceMeter SMU Instrument (1fA, 10A Pulse, Benchtop Version) 2635B Single-channel System SourceMeter SMU Instrument (0.1fA, 10A Pulse) 2636B Dual-channel System SourceMeter SMU Instrument (0.1fA, 10A Pulse) Accessories Supplied Operators and Programming Manuals 2600-ALG-2: Low Noise Triax Cable with Alligator Clips, 2m (6.6 ft.) (two supplied with 2634B and 2636B, one with 2635B) 2600-Kit: Screw Terminal Connector Kit (2601B/ 2602B/2604B/2611B/2612B/2614B) 2600B-800A: Series 2400 Emulation Script for Series 2600B (supplied on USB memory stick) Unmatched Throughput for Automated Test with TSP Technology For test applications that demand the highest levels of automation and throughput, the Model 2600B's TSP technology delivers industry-best performance. TSP technology goes far beyond traditional test command sequencers... it fully embeds then executes complete test programs from within the SMU instrument itself. This virtually eliminates all the time-consuming bus communications to and from the PC controller, and thus dramatically improves overall test times. * Conditional branching * Advanced calculations and flow control * Variables * Pass/Fail test * Prober/Handler control * Datalogging/ Formatting <500ns SMU1 SMU2 SMU3 SMU4 All channels in the TSP-Link system are synchronized to under 500ns. Test Script DUT TSP technology executes complete test programs from the 2600B's non-volatile memory. SMU-Per-Pin Parallel Testing with TSP-Link Technology TSP-Link is a channel expansion bus that enables multiple Series 2600B's to be inter-connected and function as a single, tightly-synchronized, multi-channel system. The 2600B's TSP-Link Technology works together with its TSP technology to enable high-speed, SMU-per-pin parallel testing. Unlike other high-speed solutions such as large ATE systems, the 2600B achieves parallel test performance without the cost or burden of a mainframe. The TSP-Link based system also enables superior flexibility, allowing for quick and easy system re-configuration as test requirements change. 7709-308A: Digital I/O Connector CA-180-3A: TSP-Link/Ethernet Cable (two per unit) Model 2400 Software Emulation The Series 2600B is compatible with test code developed for Keithley's Model 2400 SourceMeter SMU instrument. This enables an easier upgrade from Model 2400-based test systems to Series 2600B, and can improve test speeds by as much as 80%. In addition, it provides a migration path from SCPI programming to Keithley's TSP technology, which when implemented can improve test times even more. For complete support of legacy test systems, the Model 2400's Source-Memory-List test sequencer is also fully supported in this mode. Third-generation SMU Instrument Design Ensures Faster Test Times Based on the proven architecture of earlier Series 2600 instruments, the Series 2600B's SMU instrument design enhances test speed in several ways. For example, while earlier designs used a parallel current ranging topology, the Series 2600B uses a patented series ranging topology, which provides faster and smoother range c hanges and outputs that settle more quickly. Test 1 running Test 2 running Test 3 running To Device 1 To Device 2 To Device 3 TSP Express Software Tool (embedded) Test Script Builder Software (supplied on CD) LabVIEW Driver (supplied on CD) ACS Basic Edition Software (optional) GPIB, USB, or Ethernet TSP-Link Scalable, integrated source and measure solutions Ordering Information System SourceMeter(R) SMU Instruments SMU-Per-Pin Parallel Testing using TSP and TSP-Link improves test throughput and lowers the cost of test. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence SMU INSTRUMENTS Series 2600B System SourceMeter(R) SMU Instruments The Series 2600B SMU instrument design supports two modes of operation for use with a variety of loads. In normal mode, the SMU instrument provides high bandwidth performance for maximum throughput. In high capacitance (high-C) mode, the SMU instrument uses a slower bandwidth to provide robust performance with higher capacitive loads. Table 1. Series 2600B software tools Simplify Semiconductor Component Test, Verification, and Analysis The optional ACS Basic Edition software maximizes the productivity of customers who perform packaged part characterization during development, quality verification, or failure analysis. Key features include: * Rich set of easy-to-access test libraries * Script editor for fast customization of existing tests * Data tool for comparing results quickly * Formulator tool that analyzes captured curves and provides a wide range of math functions Feature/ Functionality ACS Basic Edition Java-based Plug & Play Test Script Builder (TSB) Semiconductor characterization software for component test, verification, and analysis Series 2400, Series 2600B, 4200-SCS Quick Start Java-based Plug & Play Tool for fast and easy I-V testing, primarily for bench and lab users Custom script writing tool for TSP instruments Series 2600B Series 2600B, Series 3700 GPIB, LAN/LXI LAN/LXI GPIB, RS-232, LAN/LXI, USB Functionality Intuitive, wizard-based GUI, Rich set of test libraries, curve trace capability Linear/Log Sweeps, Pulsing, Custom sweeps, Single point source-measures. Note: Uses new 2600B's new API's for precision timing and channel synchronization Custom scripts with total flexibility, full featured debugger Data management Formulator tool with wide range of math functions .csv export User defined Optional purchase Not necessary. Embedded in the instrument. Free Download or CD Install on PC. Description Supported hardware Supported buses Installation For more information about the ACS Basic Edition software, please refer to the ACS Basic Edition data sheet. Powerful Software Tools In addition to the embedded Java-based plug & play software and optional ACS Basic Edition software, the free Test Script Builder software tool is provided to help users create, modify, debug, and store TSP test scripts. Table 1 describes key features of Series 2600B software tools. Three New Dual-Channel BenchTop Models of Series 2600B Offer Industry-Best Value and Performance For applications that do not require leading-edge system-level automation capabilities, Keithley has expanded the Series 2600B to include 3 new value-priced "bench-top" models - the 2604B, 2614B, and 2634B. These models offer similar performance to Models 2602B, 2612B, and 2636B, respectively, however do not include TSPLink, Contact Check, and Digital I/O capabilities. Complete Automated System Solutions Keithley's S500 Integrated Test Systems are highly configurable, instrument-based systems for semiconductor characterization at the device, wafer, or cassette level. Built on our proven Series 2600B System SourceMeter SMU instruments, our S500 Integrated Test Systems When you need to acquire data on a packaged part quickly, the wizard-based user interface of ACS Basic Edition makes it easy to find and run the test you want, like this common FET curve trace test. provide innovative measurement features and system flexibility, scalable to your needs. The unique measurement capability, combined with the powerful and flexible Automated Characterization Suite (ACS) software, provides a comprehensive range of applications and features not offered on other comparable systems on the market. The flexible software architecture of ACS Basic Edition allows configuring systems with a wide range of controllers and test fixtures, as well as the exact number of SourceMeter SMU instruments the application requires. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Scalable, integrated source and measure solutions Scalable, integrated source and measure solutions SMU INSTRUMENTS Series 2600B System SourceMeter(R) SMU Instruments Typical Applications I-V functional test and characterization of a wide range of devices, including: -- Two-leaded - Sensors, disk drive heads, metal oxide varistors (MOVs), diodes, zener diodes, sensors, capacitors, thermistors -- Three-leaded - Small signal bipolar junction transistors (BJTs), field-effect transistors (FETs), and more * Simple ICs - Optos, drivers, switches, sensors, converters, regulators * Integrated devices - small scale integrated (SSI) and large scale integrated (LSI) -- Analog ICs -- Radio frequency integrated circuits (RFICs) -- Application specific integrated circuits (ASICs) -- System on a chip (SOC) devices * Optoelectronic devices such as light-emitting diodes (LEDs), laser diodes, high brightness LEDs (HBLEDs), vertical cavity surface-emitting lasers (VCSELs), displays +10A +5A +3A +1.5A +1A DC 0A Pulse -1A -1.5A -3A -5A -10A -40V -35V -20V -6V 0V +6V +20V +35V +40V Models 2601B, 2602B, and 2604B I-V capability +10A * Wafer level reliability -- NBTI, TDDB, HCI, electromigration * Solar Cells * Batteries * And more... +1.5A +1A +0.1A 0A -0.1A DC Pulse -1A -1.5A -10A -200V -180V -20V -5V 0V +5V +20V +180V +200V Models 2611B, 2612B, and 2614B I-V capability +10A Model 2604B/2614B rear panel (Single channels 2601B, 2611B, 2635B not shown) +1.5A +1A +0.1A 0A -0.1A DC Pulse -1A -1.5A -10A -200V -180V Model 2636B rear panel -20V -5V 0V +5V +20V Models 2634B, 2635B, and 2636B I-V capability 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence +180V +200V SMU INSTRUMENTS Scalable, integrated source and measure solutions * Discrete and passive components In the first and third quadrants, Series 2600B SMU instruments operate as a source, delivering power to a load. In the second and fourth quadrants, they operate as a sink, dissipating power internally. Scalable, integrated source and measure solutions Series 2600B System SourceMeter(R) SMU Instruments Series 2600B specifications SPECIFICATION CONDITIONS ADDITIONAL SOURCE SPECIFICATIONS This document contains specifications and supplemental information for the Models 2601B, 2602B, and 2604B System SourceMeter(R) SMU instruments. Specifications are the standards against which the Models 2601B, 2602B, and 2604B are tested. Upon leaving the factory, the 2601B, 2602B, and 2604B meet these specifications. Supplemental and typical values are non-warranted, apply at 23C, and are provided solely as useful information. Accuracy specifications are applicable for both normal and high capacitance modes. The source and measurement accuracies are specified at the SourceMeter CHANNEL A (2601B, 2602B, and 2604B) or SourceMeter CHANNEL B (2602B and 2604B) terminals under the following conditions: 1. 23C 5C, <70% relative humidity 2. After 2 hour warm-up 3. Speed normal (1 NPLC) 4. A/D auto-zero enabled 5. Remote sense operation or properly zeroed local operation 6. Calibration period = 1 year SOURCE SPECIFICATIONS Voltage Source Specifications VOLTAGE PROGRAMMING ACCURACY1 Accuracy (1 Year) Programming 23C 5C Range Resolution (% rdg. + volts) 100 mV 5 V 0.02% + 250 V 1 V 50 V 0.02% + 400 V 6 V 50 V 0.02% + 1.8 mV 40 V 500 V 0.02% + 12 mV Typical Noise (peak-peak) 0.1Hz-10Hz 20 V 50 V 100 V 500 V TEMPERATURE COEFFICIENT (0-18C and 28-50C) 2: (0.15 x accuracy specification)/C. Applicable for normal mode only. Not applicable for high capacitance mode. MAXiMUM OUTPUT POWER AND SOURCE/SINK LIMITS 3: 40.4W per channel maximum. 40.4V @ 1.0A, 6.06V @ 3.0A, four quadrant source or sink operation. VOLTAGE REGULATION: Line: 0.01% of range. Load: (0.01% of range + 100V). NOISE 10Hz-20MHz: <20mV peak-peak (typical), <3mV RMS (typical), 6V range. CURRENT LIMIT/COMPLIANCE 4: Bipolar current limit (compliance) set with single value. Minimum value is 10nA. Accuracy same as current source. OVERSHOOT: <(0.1% + 10mV) typical. Step size = 10% to 90% of range, resistive load, maximum c urrent limit/compliance. GUARD OFFSET VOLTAGE: <4mV typical. Current <10mA. SMU INSTRUMENTS Current Source Specifications CURRENT PROGRAMMING ACCURACY Accuracy (1 Year) Programming 23C 5C Range Resolution (% rdg. + amps) 100 nA 2 pA 0.06% + 100 pA 1 A 20 pA 0.03% + 800 pA 10A 200 pA 0.03% + 5 nA 100 A 2 nA 0.03% + 60 nA 1 mA 20 nA 0.03% + 300 nA 10 mA 200 nA 0.03% + 6 A 100 mA 2 A 0.03% + 30 A 1 A5 20 A 0.05% + 1.8 mA 20 A 0.06% + 4 mA 3 A5 200 A 0.5 % + 40 mA (typical) 10 A 5, 6 Typical Noise (peak-peak) 0.1Hz-10Hz 5 pA 25 pA 60 pA 3 nA 6 nA 200 nA 600 nA 70 A 150 A TRANSIENT RESPONSE TIME: <70s for the output to recover to within 0.1% for a 10% to 90% step change in load. VOLTAGE SOURCE OUTPUT SETTLING TIME: Time required to reach within 0.1% of final value after source level command is processed on a fixed range. 100mV, 1V Ranges: <50s typical. 6V Range: <100s typical. 40V Range 10: <150s typical. CURRENT SOURCE OUTPUT SETTLING TIME: Time required to reach within 0.1% of final value after source level command is processed on a fixed range. Values below for Iout x R load = 1V unless noted. 3A Range: <80s typical (current less than 2.5A, R load >2W). 1A-10mA Ranges: <80s typical (R load >6W). 1mA Range: <100s typical. 100A Range: <150s typical. 10A Range: <500s typical. 1A Range: <2.5ms typical. 100nA Range: <25ms typical. DC FLOATING VOLTAGE: Output can be floated up to 250VDC from chassis ground. REMOTE SENSE OPERATING RANGE 11: Maximum voltage between HI and SENSE HI = 3V . Maximum voltage between LO and SENSE LO = 3V . VOLTAGE OUTPUT HEADROOM: 40V Range: Max. output voltage = 42V - total voltage drop across source leads (maximum 1W per source lead). 6V Range: Max. output voltage = 8V - total voltage drop across source leads (maximum 1W per source lead). OVER TEMPERATURE PROTECTION: Internally sensed temperature overload puts unit in standby mode. VOLTAGE SOURCE RANGE CHANGE OVERSHOOT: <300mV + 0.1% of larger range (typical). Overshoot into an 100kW load, 20MHz BW. CURRENT SOURCE RANGE CHANGE OVERSHOOT: <5% of larger range + 300mV/R load (typical with source settling set to SETTLE_SMOOTH_100NA). See Current Source Output Settling Time for additional test conditions. NOTES 1. Add 50V to source accuracy specifications per volt of HI lead drop. 2. High Capacitance Mode accuracy is applicable at 23C 5C only. 3. Full power source operation regardless of load to 30C ambient. Above 30C and/or power sink operation, refer to "Operating Boundaries" in the Series 2600B Reference Manual for additional power derating information. 4. For sink mode operation (quadrants II and IV), add 0.06% of limit range to the corresponding current limit accuracy specifications. Specifications apply with sink mode operation enabled. 5. Full power source operation regardless of load to 30C ambient. Above 30C and/or power sink operation, refer to "Operating Boundaries" in the Series 2600B Reference Manual for additional power derating information. 6. 10A range accessible only in pulse mode. 7. High Capacitance Mode accuracy is applicable at 23C 5C only. 8. Full power source operation regardless of load to 30C ambient. Above 30C and/or power sink operation, refer to "Operating Boundaries" in the Series 2600B Reference Manual for additional power derating information. 9. For sink mode operation (quadrants II and IV), add 10% of compliance range and 0.02% of limit setting to corresponding voltage source specification. For 100mV range add an additional 60mV of uncertainty. 10. Add 150s when measuring on the 1A range. 11. Add 50V to source accuracy specifications per volt of HI lead drop. TEMPERATURE COEFFICIENT (0-18C and 28-50C) 7: (0.15 x accuracy specification)/C. MAXiMUM OUTPUT POWER AND SOURCE/SINK LIMITS 8: 40.4W per channel maximum. 1.01A @ 40.0V , 3.03A @ 6.0V , four quadrant source or sink operation. CURRENT REGULATION: Line: 0.01% of range. Load: (0.01% of range + 100pA). VOLTAGE LIMIT/COMPLIANCE 9: Bipolar voltage limit (compliance) set with a single value. Minimum value is 10mV. Accuracy is the same as voltage source. OVERSHOOT: <0.1% typical (step size = 10% to 90% of range, resistive load; see Current Source Output Settling Time for additional test conditions). 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 2600B specifications Series 2600B 2601B, 2602B, 2604B System SourceMeter(R) SMU Instruments METER SPECIFICATIONS VOLTAGE MEASUREMENT ACCURACY 16, 17 PULSE SPECIFICATIONS Series 2600B specifications Region 1 1 2 3 4 Maximum Pulse Width 12 DC, no limit DC, no limit 100 ms 4 ms 1.8 ms Maximum Duty Cycle 13 100% 100% 25% 4% 1% MINIMUM PROGRAMMABLE PULSE WIDTH 14, 15: 100s. NOTE: Minimum pulse width for settled source at a given I/V output and load can be longer than 100s. Pulse width programming resolution: 1s. Pulse width programming accuracy 15: 5s. pulse width jitter: 2s (typical). Quadrant Diagram: Range 100 mV 1 V 6 V 40 V CURRENT MEASUREMENT ACCURACY 17 Range 100 nA 1 A 10 A 100 A 1 mA 10 mA 100 mA 1 A 3 A 10 A 22 4 +3A 3 3 +1.5A +1A 2 2 0A 1 DC Pulse -1A -1.5A Pulse 2 2 3 -5A 4 -10A -40V -35V -20V -6V 0V +6V +20V +35V Pulse Level FAST 90% MEDIUM SLOW Start toff 10% 10% ton 13. Thermally limited in sink mode (quadrants II and IV) and ambient temperatures above 30C. See power equations in the reference manual for more information. 14. Typical performance for minimum settled pulse widths: Source Settling Source Value Load (% of range) Min. Pulse Width 2W 2W 7W 27 W 27 W 2W 7W 2W 0.2% 1% 0.5% 0.1% 0.1% 0.2% 0.5% 0.5% 150 s 200 s 500 s 400 s 1.5 ms 150 s 500 s 200 s Typical tests were performed using remote operation, 4W sense, and best, fixed measurement range. For more information on pulse scripts, see the Series 2600B Reference Manual. 15. Times measured from the start of pulse to the start off-time; see figure below. Pulse Level 90% Start toff Start ton Bias Level 10% 10% ton toff Accuracy (1 Year) 23C 5C (% rdg. + amps) 0.05% + 100 pA 0.025% + 500 pA 0.025% + 1.5 nA 0.02% + 25 nA 0.02% + 200 nA 0.02% + 2.5 A 0.02% + 20 A 0.03% + 1.5 mA 0.05% + 3.5 mA 0.4% + 25 mA (typical) Accuracy (1 Year) 23C 5C (%rdg. + ohms) 1 (1.2) ms 5% + 10 W 4 (5) ms 36 (42) ms 5% + 1 W 5% + 0.3 W ADDITIONAL METER SPECIFICATIONS toff 6V 20 V 35 V 40 V 1.5 A 3A 5A 10 A Voltage Burden 21 <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV Maximum Measurement Time To Memory For 60Hz (50Hz) Speed 12. Times measured from the start of pulse to the start off-time; see figure below. Bias Level Default Display Resolution 20 100 fA 1 pA 10 pA 100 pA 1 nA 10 nA 100 nA 1 A 1 A 10 A Contact Check 25 (not available on Model 2604B) +40V NOTES Start ton Accuracy (1 Year) 23C 5C (% rdg. + volts) 0.015% + 150 V 0.015% + 200 V 0.015% + 1 mV 0.015% + 8 mV Current Measure Settling Time (Time for measurement to settle after a Vstep) 23: Time required to reach within 0.1% of final value after source level command is processed on a fixed range. Values for Vout = 1V unless noted. Current Range: 1mA. Settling Time: <100s (typical). TEMPERATURE COEFFICIENT (0-18C and 28-50C) 24: (0.15 x accuracy specification/C. Applicable for normal mode only. Not applicable for high capacitance mode. Pulse 3 -3A Input Resistance >10 GW >10 GW >10 GW >10 GW TEMPERATURE COEFFICIENT (0-18C and 28-50C) 19: (0.15 x accuracy specification)/C. Applicable for normal mode only. Not applicable for high capacitance mode. +10A +5A Default Display Resolution 18 100 nV 1 V 10 V 10 V Maximum LOAD IMPEDANCE: Normal Mode: 10nF (typical). High Capacitance Mode: 50F (typical). COMMON MODE VOLTAGE: 250VDC. COMMON MODE ISOLATION: >1GW, <4500pF. OVERRANGE: 101% of source range, 102% of measure range. MAXIMUM SENSE LEAD RESISTANCE: 1kW for rated accuracy. SENSE INPUT IMPEDANCE: >10GW. NOTES 16. Add 50V to source accuracy specifications per volt of HI lead drop. 17. De-rate accuracy specifications for NPLC setting < 1 by increasing error term. Add appropriate % of range term using table below. 100mV 1V-40V 100nA 1A-100mA NPLC Setting Range Ranges Range Ranges 0.1 0.01% 0.01% 0.01% 0.01% 0.01 0.08% 0.07% 0.1% 0.05% 0.001 0.8 % 0.6 % 1% 0.5 % 1A-3A Ranges 0.01% 0.05% 1.1 % 18. Applies when in single channel display mode. 19. High Capacitance Mode accuracy is applicable for 23C 5C only. 20. Applies when in single channel display mode. 21. Four-wire remote sense only with current meter mode selected. Voltage measure set to 100mV or 1V range only. 22. 10A range accessible only in pulse mode. 23. Compliance equal to 100mA. 24. High Capacitance Mode accuracy is applicable for 23C 5C only. 25. Includes measurement of SENSE HI to HI and SENSE LO to LO contact resistances. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence SMU INSTRUMENTS Maximum Current Limit 1 A @ 40 V 3A@ 6V 1.5 A @ 40 V 5 A @ 35 V 10 A @ 20 V Series 2600B specifications SOURCE SPECIFICATIONS (continued) 2601B, 2602B, 2604B System SourceMeter(R) SMU Instruments Voltage Source Output Settling Time: Time required to reach 0.1% of final value after source level command is processed on a fixed range. Current limit = 1A. Voltage Source Range Settling Time with Cload = 4.7F 100 mV 200 s (typical) 1 V 200 s (typical) 6 V 200 s (typical) 40 V 7 ms (typical) Current Measure Settling Time: Time required to reach 0.1% of final value after voltage source is stabilized on a fixed range. Values below for Vout = 1V unless noted. Current Measure Range Settling Time 3A-1A <120 s (typical) (R load > 2W) 100 mA - 10 mA <100 s (typical) 1 mA < 3 ms (typical) 100A < 3 ms (typical) 10A < 230 ms (typical) 1A < 230 ms (typical) Capacitor Leakage Performance Using HIGH-C scripts 29: Load = 5F||10MW. Test: 5V step and measure. 200ms (typical) @ 50nA. Mode Change Delay: 100A Current Range and Above: Delay into High Capacitance Mode: 10ms. Delay out of High Capacitance Mode: 10ms. 1A and 10A Current Ranges: Delay into High Capacitance Mode: 230ms. Delay out of High Capacitance Mode: 10ms. Voltmeter Input Impedance: 10GW in parallel with 3300pF. Noise, 10Hz-20MHz (6V Range): <30mV peak-peak (typical). Voltage Source Range Change Overshoot: <400mV + 0.1% of larger range (typical). Overshoot into a 100kW load, 20MHz BW. NOTES 26. High Capacitance Mode specifications are for DC measurements only. 27. 100nA range is not available in High Capacitance Mode. 28. High Capacitance Mode utilizes locked ranges. Auto Range is disabled. 29. Part of KI Factory scripts. See reference manual for details. GENERAL IEEE-488: IEEE-488.1 compliant. Supports IEEE-488.2 common commands and status model topology. USB Control (rear): USB 2.0 device, TMC488 protocol. RS-232: Baud rates from 300bps to 115200bps. Ethernet: RJ-45 connector, LXI Class C, 10/100BT, no auto MDIX. EXPANSION INTERFACE: The TSP-Link expansion interface allows TSP enabled instruments to trigger and communicate with each other. (Not available on Model 2604B.) Cable Type: Category 5e or higher LAN crossover cable. Length: 3 meters maximum between each TSP enabled instrument. LXI Compliance: LXI Class C 1.4. LXI Timing: Total Output Trigger Response Time: 245s min., 280s typ., (not specified) max. Receive LAN[0-7] Event Delay: Unknown. Generate LAN[0-7] Event Delay: Unknown. DIGITAL I/O INTERFACE: (Not available on Model 2604B) +5V Pins Solid State Fuse Digital I/O Pin 100 +5VDC (on DIGITAL I/O connector) 5.1k (on DIGITAL I/O connector) Written by firmware GND Pin (on DIGITAL I/O connector) Read by firmware Rear Panel SMU INSTRUMENTS Connector: 25-pin female D. Input/Output Pins: 14 open drain I/O bits. Absolute Maximum Input Voltage: 5.25V. Absolute Minimum Input Voltage: -0.25V. Maximum Logic Low Input Voltage: 0.7V, +850A max. Minimum Logic High Input Voltage: 2.1V, +570A. Maximum Source Current (flowing out of Digital I/O bit): +960A. Maximum Sink Current @ Maximum Logic Low Voltage (0.7V): -5.0mA. Absolute Maximum Sink Current (flowing into Digital I/O pin): -11mA (not including Model 2604B). 5V Power Supply Pins: Limited to 250mA total for all three pins, solid state fuse protected. Output Enable: Active high input pulled down internally to ground with a 10k resistor; when the output enable input function has been activated, each SourceMeter channel will not turn on unless the output enable pin is driven to >2.1V (nominal current = 2.1V/10k = 210A). USB File System (Front): USB 2.0 Host: Mass storage class device. POWER SUPPLY: 100V to 250VAC, 50-60Hz (auto sensing), 240VA max. COOLING: Forced air. Side intake and rear exhaust. One side must be unobstructed when rack mounted. EMC: Conforms to European Union Directive 2004/108/EEC, EN 61326-1. SAFETY: Conforms to European Union Directive 73/23/EEC, EN 61010-1, and UL 61010-1. DIMENSIONS: 89mm high x 213mm wide x 460mm deep (31/2 in x 838 in x 171/2 in). Bench Configuration (with handle and feet): 104mm high x 238mm wide x 460mm deep (418 in x 938 in x 171/2 in). WEIGHT: 2601B: 4.75kg (10.4 lbs). 2602B, 2604B: 5.50kg (12.0 lbs). ENVIRONMENT: For indoor use only. Altitude: Maximum 2000 meters above sea level. Operating: 0-50C, 70% R.H. up to 35C. Derate 3% R.H./C, 35-50C. Storage: -25C to 65C. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 2600B specifications Series 2600B specifications HIGH CAPACITANCE MODE 26, 27, 28 System SourceMeter(R) SMU Instruments ADDITIONAL SOURCE SPECIFICATIONS This document contains specifications and supplemental information for the Models 2611B, 2612B, and 2614B System SourceMeter(R) SMU instruments. Specifications are the standards against which the Models 2611B, 2612B, and 2614B are tested. Upon leaving the factory the 2611B, 2612B, and 2614B meet these specifications. Supplemental and typical values are non-warranted, apply at 23C, and are provided solely as useful information. Accuracy specifications are applicable for both normal and high capacitance modes. The source and measurement accuracies are specified at the SourceMeter CHANNEL A (2611B, 2612B, and 2614B) or SourceMeter CHANNEL B (2612B, 2614B) terminals under the following conditions: 1. 23C 5C, <70% relative humidity. 2. After 2 hour warm-up. 3. Speed normal (1 NPLC). 4. A/D auto-zero enabled. 5. Remote sense operation or properly zeroed local sense operation. 6. Calibration period = 1 year. SOURCE SPECIFICATIONS Voltage Source Specifications VOLTAGE PROGRAMMING ACCURACY1 Accuracy (1 Year) Programming 23C 5C Range Resolution (% rdg. + volts) 200 mV 5 V 0.02% + 375 V 2 V 50 V 0.02% + 600 V 20 V 500 V 0.02% + 5 mV 200 V 5 mV 0.02% + 50 mV Typical Noise (Peak-Peak) 0.1Hz-10Hz 20 V 50 V 300 V 2 mV TEMPERATURE COEFFICIENT (0-18C and 28-50C) 2: (0.15 x accuracy specification)/C. Applicable for normal mode only. Not applicable for high capacitance mode. MAXiMUM OUTPUT POWER AND SOURCE/SINK LIMITS 3: 30.3W per channel maximum. 20.2V @ 1.5A, 202V @ 100mA, four quadrant source or sink operation. VOLTAGE REGULATION: Line: 0.01% of range. Load: (0.01% of range + 100V). NOISE 10Hz-20MHz: <20mV peak-peak (typical), <3mV RMS (typical), 20V range. CURRENT LIMIT/COMPLIANCE 4: Bipolar current limit (compliance) set with single value. Minimum value is 10nA. Accuracy is the same as current source. OVERSHOOT: <(0.1% + 10mV) (typical). Step size = 10% to 90% of range, resistive load, maximum c urrent limit/compliance. GUARD OFFSET VOLTAGE: <4mV (current <10mA). Current Source Specifications CURRENT PROGRAMMING ACCURACY 5 Range 100 nA 1 A 10 A 100 A 1 mA 10 mA 100 mA 1 A 6 1.5 A 6 10 A 6, 7 Programming Resolution 2 pA 20 pA 200 pA 2 nA 20 nA 200 nA 2 A 20 A 50 A 200 A Accuracy (1 Year) 23C 5C (% rdg. + amps) 0.06% + 100 pA 0.03% + 800 pA 0.03% + 5 nA 0.03% + 60 nA 0.03% + 300 nA 0.03% + 6 A 0.03% + 30 A 0.05% + 1.8 mA 0.06% + 4 mA 0.5% + 40 mA (typical) Typical Noise (Peak-Peak) 0.1Hz-10Hz 5 pA 25 pA 60 pA 3 nA 6 nA 200 nA 600 nA 70 A 150 A TEMPERATURE COEFFICIENT (0-18C and 28-50C) 8: (0.15 x accuracy specification)/C. Applicable for normal mode only. Not applicable for high capacitance mode. MAXiMUM OUTPUT POWER AND SOURCE/SINK LIMITS 9: 30.3W per channel maximum. 1.515A @ 20V , 101mA @ 200V , four quadrant source or sink operation. CURRENT REGULATION: Line: 0.01% of range. Load: (0.01% of range + 100pA). VOLTAGE LIMIT/COMPLIANCE 10: Bipolar voltage limit (compliance) set with a single value. Minimum value is 20mV. Accuracy is the same as voltage source. OVERSHOOT: <0.1% (typical). Step size = 10% to 90% of range, resistive load; see Current Source Output Settling Time for additional test conditions. TRANSIENT RESPONSE TIME: <70s for the output to recover to within 0.1% for a 10% to 90% step change in load. VOLTAGE SOURCE OUTPUT SETTLING TIME: Time required to within reach 0.1% of final value after source level command is processed on a fixed range. Range Settling Time 200 mV <50 s (typical) 2 V <50 s (typical) 20 V <110 s (typical) 200 V <700 s (typical) CURRENT SOURCE OUTPUT SETTLING TIME: Time required to reach within 0.1% of final value after source level command is processed on a fixed range. Values below for Iout * R load = 2V unless noted. Current Range Settling Time 1.5 A - 1 A <120 s (typical) (R load > 6W) 100 mA - 10 mA <80 s (typical) 1 mA <100 s (typical) 100A <150 s (typical) 10A <500 s (typical) 1A <2 ms (typical) 100 nA <20 ms (typical) DC FLOATING VOLTAGE: Output can be floated up to 250VDC from chassis ground. REMOTE SENSE OPERATING RANGE 11: Maximum voltage between HI and SENSE HI = 3V . Maximum voltage between LO and SENSE LO = 3V . VOLTAGE OUTPUT HEADROOM: 200V Range: Max. output voltage = 202.3V - total voltage drop across source leads (maximum 1W per source lead). 20V Range: Max. output voltage = 23.3V - total voltage drop across source leads (maximum 1W per source lead). OVER TEMPERATURE PROTECTION: Internally sensed temperature overload puts unit in standby mode. VOLTAGE SOURCE RANGE CHANGE OVERSHOOT: <300mV + 0.1% of larger range (typical). Overshoot into a 200kW load, 20MHz BW. CURRENT SOURCE RANGE CHANGE OVERSHOOT: <5% of larger range + 300mV/R load (typical - With source settling set to SETTLE_SMOOTH_100NA). See Current Source Output Settling Time for additional test conditions. Series 2600B specifications Series 2600B specifications SPECIFICATION CONDITIONS NOTES 1. Add 50V to source accuracy specifications per volt of HI lead drop. 2. High Capacitance Mode accuracy is applicable at 23C 5C only. 3. Full power source operation regardless of load to 30C ambient. Above 30C and/or power sink operation, refer to "Operating Boundaries" in the Series 2600B Reference Manual for additional power derating information. 4. For sink mode operation (quadrants II and IV), add 0.06% of limit range to the corresponding current limit accuracy specifications. Specifications apply with sink mode operation enabled. 5. Accuracy specifications do not include connector leakage. Derate accuracy by Vout/2E11 per C when operating between 18-28C. Derate accuracy by Vout/2E11 + (0.15*Vout/2E11) per C when operating <18C and >28C. 6. Full power source operation regardless of load to 30C ambient. Above 30C and/or power sink operation, refer to "Operating Boundaries" in the Series 2600B Reference Manual for additional power derating information. 7. 10A range accessible only in pulse mode. 8. High Capacitance Mode accuracy is applicable at 23C 5C only. 9. Full power source operation regardless of load to 30C ambient. Above 30C and/or power sink operation, refer to "Operating Boundaries" in the Series 2600B Reference Manual for additional power derating information. 10. For sink mode operation (quadrants II and IV), add 10% of compliance range and 0.02% of limit setting to corresponding voltage source specification. For 200mV range add an additional 120mV of uncertainty. 11. Add 50V to source accuracy specifications per volt of HI lead drop. PULSE SPECIFICATIONS Region 1 1 2 3 14 4 Maximum Current Limit 100 mA @ 200 V 1.5 A @ 20 V 1 A @ 180 V 1 A @ 200 V 10 A @ 5 V Maximum Pulse Width 12 DC, no limit DC, no limit 8.5 ms 2.2 ms 1 ms Maximum Duty Cycle 13 100% 100% 1% 1% 2.2% MINIMUM PROGRAMMABLE PULSE WIDTH 15, 16: 100s. NOTE: Minimum pulse width for settled source at a given I/V output and load can be longer than 100s. Pulse width programming resolution: 1s. Pulse width programming accuracy 16: 5s. pulse width jitter: 2s (typical). 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence SMU INSTRUMENTS 2611B, 2612B, 2614B 2611B, 2612B, 2614B System SourceMeter(R) SMU Instruments SOURCE SPECIFICATIONS (continued) METER SPECIFICATIONS PULSE SPECIFICATIONS (continued) VOLTAGE MEASUREMENT ACCURACY 17, 18 Quadrant Diagram: +10A Range 200 mV 2 V 20 V 200 V 4 3 3 2 +0.1A 0A -0.1A 2 Pulse 2 -1A -1.5A 2 3 Pulse 3 CURRENT MEASUREMENT ACCURACY 18, 21 Pulse 4 Range 100 nA 1 A 10 A 100 A 1 mA 10 mA 100 mA 1 A 1.5 A 10 A 24 -10A -200V -180V -20V 0V -5V +5V +20V +180V +200V NOTES 12. Times measured from the start of pulse to the start off-time; see figure below. Pulse Level 90% Start toff Start ton Bias Level 10% 10% ton toff 13. Thermally limited in sink mode (quadrants II and IV) and ambient temperatures above 30C. See power equations in the reference manual for more information. 14. Voltage source operation with 1.5 A current limit. 15. Typical performance for minimum settled pulse widths: Source Settling Source Value Load (% of range) Min. Pulse Width 5V 20 V 180 V 200 V (1.5 A Limit) 100 mA 1A 1A 10 A 0.5 W 200 W 180 W 200 W 200 W 200 W 180 W 0.5 W 1% 0.2% 0.2% 0.2% 1% 1% 0.2% 0.5% 300 s 200 s 5 ms 1.5 ms 200 s 500 s 5 ms 300 s Typical tests were performed using remote operation, 4W sense, and best, fixed measurement range. For more information on pulse scripts, see the Series 2600B Reference Manual. 16. Times measured from the start of pulse to the start off-time; see figure below. Pulse Level 90% Start toff Start ton Bias Level 10% 10% Default Display Resolution 22 100 fA 1 pA 10 pA 100 pA 1 nA 10 nA 100 nA 1 A 1 A 10 A Voltage Burden 23 <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV Accuracy (1 Year) 23C 5C (% rdg. + amps) 0.06% + 100 pA 0.025% + 500 pA 0.025% + 1.5 nA 0.02% + 25 nA 0.02% + 200 nA 0.02% + 2.5 A 0.02% + 20 A 0.03% + 1.5 mA 0.05% + 3.5 mA 0.4% + 25 mA (typical) Current Measure Settling Time (Time for measurement to settle after a Vstep) 25: Time required to reach 0.1% of final value after source level command is processed on a fixed range. Values for Vout = 2V unless noted. Current Range: 1mA. Settling Time: <100s (typical). TEMPERATURE COEFFICIENT (0-18C and 28-50C) 26: (0.15 x accuracy specfication)/C. Applicable for normal mode only. Not applicable for high capacitance mode. Contact Check 27 (not available on Model 2614B) Maximum Measurement Time to Memory For 60Hz (50Hz) Speed Accuracy (1 Year) 23C 5C (%rdg. + ohms) FAST 1 (1.2) ms 5% + 10 W MEDIUM 4 (5) ms 5% + 1 W 36 (42) ms 5% + 0.3 W SLOW ADDITIONAL METER SPECIFICATIONS Maximum LOAD IMPEDANCE: Normal Mode: 10nF (typical). High Capacitance Mode: 50F (typical). COMMON MODE VOLTAGE: 250VDC. COMMON MODE ISOLATION: >1GW, <4500pF. OVERRANGE: 101% of source range, 102% of measure range. MAXIMUM SENSE LEAD RESISTANCE: 1kW for rated accuracy. SENSE INPUT IMPEDANCE: >10GW. toff SMU INSTRUMENTS ton Accuracy (1 Year) 23C 5C (% rdg. + volts) 0.015% + 225 V 0.02% + 350 V 0.015% + 5 mV 0.015% + 50 mV TEMPERATURE COEFFICIENT (0-18C and 28-50C) 20: (0.15 x accuracy specification)/C. Applicable for normal mode only. Not applicable for high capacitance mode. DC 1 Input Resistance >10 GW >10 GW >10 GW >10 GW 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 2600B specifications Series 2600B specifications +1.5A +1A Default Display Resolution 19 100 nV 1 V 10 V 100 V 2611B, 2612B, 2614B System SourceMeter(R) SMU Instruments METER SPECIFICATIONS (continued) 17. Add 50V to source accuracy specifications per volt of HI lead drop. 18. De-rate accuracy specifications for NPLC setting <1 by increasing error term. Add appropriate % of range term using table below. Series 2600B specifications NPLC Setting 0.1 0.01 0.001 200mV Range 0.01% 0.08% 0.8 % 2V-200V Ranges 0.01% 0.07% 0.6 % 100nA Range 0.01% 0.1% 1% 1A-100mA Ranges 0.01% 0.05% 0.5 % 1A-1.5A Ranges 0.01% 0.05% 1.1 % 19. Applies when in single channel display mode. 20. High Capacitance Mode accuracy is applicable at 23C 5C only. 21. Accuracy specifications do not include connector leakage. De-rate accuracy by Vout/2E11 per C when operating between 18-28C. Derate accuracy by Vout/2E11 + (0.15 * Vout/2E11) per C when operating <18 and >28C. 22. Applies when in single channel display mode. 23. Four-wire remote sense only and with current meter mode selected. Voltage measure set to 200mV or 2V range only. 24. 10A range accessible only in pulse mode. 25. Compliance equal to 100mA. 26. High Capacitance Mode accuracy is applicable at 23C 5C only. 27. Includes measurement of SENSE HI to HI and SENSE LO to LO contact resistances. HIGH CAPACITANCE MODE 28, 29, 30 Voltage Source Output Settling Time: Time required to reach within 0.1% of final value after source level command is processed on a fixed range. Current limit = 1A. Voltage Source Range Settling Time with Cload = 4.7F 200 mV 600 s (typical) 2 V 600 s (typical) 20 V 1.5 ms (typical) 200 V 20 ms (typical) Current Measure Settling Time: Time required to reach within 0.1% of final value after voltage source is stabilized on a fixed range. Values below for Vout = 2V unless noted. Current Measure Range Settling Time 1.5 A - 1 A <120 s (typical) (R load >6W) 100 mA - 10 mA <100 s (typical) 1 mA < 3 ms (typical) 100A < 3 ms (typical) 10A < 230 ms (typical) 1A < 230 ms (typical) Capacitor Leakage Performance Using HIGH-C scripts 31: Load = 5F||10MW. Test: 5V step and measure. 200ms (typical) @ 50nA. Mode Change Delay: 100A Current Range and Above: Delay into High Capacitance Mode: 10ms. Delay out of High Capacitance Mode: 10ms. 1A and 10A Current Ranges: Delay into High Capacitance Mode: 230ms. Delay out of High Capacitance Mode: 10ms. Voltmeter Input Impedance: 30GW in parallel with 3300pF. Noise, 10Hz-20MHz (20V Range): <30mV peak-peak (typical). Voltage Source Range Change Overshoot (for 20V range and below): <400mV + 0.1% of larger range (typical). Overshoot into a 200kW load, 20MHz BW. NOTES 28. High Capacitance Mode specifications are for DC measurements only. 29. 100nA range is not available in High Capacitance Mode. 30. High Capacitance Mode utilizes locked ranges. Auto Range is disabled. 31. Part of KI Factory scripts, See reference manual for details. IEEE-488: IEEE-488.1 compliant. Supports IEEE-488.2 common commands and status model topology. USB Control (rear): USB 2.0 device, TMC488 protocol. RS-232: Baud rates from 300bps to 115200bps. Ethernet: RJ-45 connector, LXI Class C, 10/100BT, no auto MDIX. EXPANSION INTERFACE: The TSP-Link expansion interface allows TSP enabled instruments to trigger and communicate with each other. (Not available on Model 2614B.) Cable Type: Category 5e or higher LAN crossover cable. Length: 3 meters maximum between each TSP enabled instrument. LXI Compliance: LXI Class C 1.4. LXI Timing: Total Output Trigger Response Time: 245s min., 280s typ., (not specified) max. Receive LAN[0-7] Event Delay: Unknown. Generate LAN[0-7] Event Delay: Unknown. DIGITAL I/O INTERFACE: (Not available on Model 2614B) +5V Pins Solid State Fuse Digital I/O Pin 100 +5VDC (on DIGITAL I/O connector) 5.1k (on DIGITAL I/O connector) Read by firmware Written by firmware GND Pin (on DIGITAL I/O connector) Rear Panel Connector: 25-pin female D. Input/Output Pins: 14 open drain I/O bits. Absolute Maximum Input Voltage: 5.25V. Absolute Minimum Input Voltage: -0.25V. Maximum Logic Low Input Voltage: 0.7V, +850A max. Minimum Logic High Input Voltage: 2.1V, +570A. Maximum Source Current (flowing out of Digital I/O bit): +960A. Maximum Sink Current @ Maximum Logic Low Voltage (0.7V): -5.0mA. Absolute Maximum Sink Current (flowing into Digital I/O pin): -11mA. 5V Power Supply Pins: Limited to 250mA total for all three pins, solid state fuse protected. Safety Interlock Pin: Active high input. >3.4V @ 24mA (absolute maximum of 6V) must be externally applied to this pin to ensure 200V operation. This signal is pulled down to chassis ground with a 10kW resistor. 200V operation will be blocked when the INTERLOCK signal is <0.4V (absolute minimum -0.4V). See figure below: Coil Resistance 145 10% INTERLOCK Pin (on DIGITAL I/O connector) Read by firmware +220V Supply -220V Supply 10k Chassis Ground * To output stage Rear Panel USB File System (Front): USB 2.0 Host: Mass storage class device. POWER SUPPLY: 100V to 250VAC, 50-60Hz (auto sensing), 240VA max. COOLING: Forced air. Side intake and rear exhaust. One side must be unobstructed when rack mounted. EMC: Conforms to European Union Directive 2004/108/EEC, EN 61326-1. SAFETY: Conforms to European Union Directive 73/23/EEC, EN 61010-1, and UL 61010-1. DIMENSIONS: 89mm high x 213mm wide x 460mm deep (31/2 in x 838 in x 171/2 in). Bench Configuration (with handle and feet): 104mm high x 238mm wide x 460mm deep (418 in x 938 in x 171/2 in). WEIGHT: 2611B: 4.75kg (10.4 lbs). 2612B, 2614B: 5.50kg (12.0 lbs). ENVIRONMENT: For indoor use only. Altitude: Maximum 2000 meters above sea level. Operating: 0-50C, 70% R.H. up to 35C. Derate 3% R.H./C, 35-50C. Storage: -25C to 65C. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence SMU INSTRUMENTS NOTES Series 2600B specifications GENERAL System SourceMeter(R) SMU Instruments Series 2600B specifications SPECIFICATION CONDITIONS ADDITIONAL SOURCE SPECIFICATIONS This document contains specifications and supplemental information for the Models 2634B, 2635B, and 2636B System SourceMeter(R) SMU instruments. Specifications are the standards against which the Models 2634B, 2635B, and 2636B are tested. Upon leaving the factory the 2634B, 2635B, and 2636B meet these specifications. Supplemental and typical values are non-warranted, apply at 23C, and are provided solely as u seful information. Accuracy specifications are applicable for both normal and high capacitance modes. The source and measurement accuracies are specified at the SourceMeter CHANNEL A (2634B, 2635B, and 2636B) or SourceMeter CHANNEL B (2634B, 2636B) terminals under the following conditions: 1. 23C 5C, <70% relative humidity. 2. After 2 hour warm-up 3. Speed normal (1 NPLC) 4. A/D auto-zero enabled 5. Remote sense operation or properly zeroed local sense operation 6. Calibration period = 1 year SOURCE SPECIFICATIONS Voltage Source Specifications VOLTAGE PROGRAMMING ACCURACY1 Accuracy (1 Year) Programming 23C 5C Range Resolution (% rdg. + volts) 200 mV 5 V 0.02% + 375 V 2 V 50 V 0.02% + 600 V 20 V 500 V 0.02% + 5 mV 200 V 5 mV 0.02% + 50 mV Typical Noise (peak-peak) 0.1Hz-10Hz 20 V 50 V 300 V 2 mV TEMPERATURE COEFFICIENT (0-18C and 28-50C) 2: (0.15 x accuracy specification)/C. Applicable for normal mode only. Not applicable for high capacitance mode. MAXiMUM OUTPUT POWER AND SOURCE/SINK LIMITS 3: 30.3W per channel maximum. 20.2V @ 1.5A, 202V @ 100mA, four quadrant source or sink operation. VOLTAGE REGULATION: Line: 0.01% of range. Load: (0.01% of range + 100V). NOISE 10Hz-20MHz: <20mV pk-pk (typical), <3mV rms (typical), 20V range. CURRENT LIMIT/COMPLIANCE 4: Bipolar current limit (compliance) set with single value. Minimum value is 100pA. Accuracy is the same as current source. OVERSHOOT: <(0.1% + 10mV) typical (step size = 10% to 90% of range, resistive load, maximum current limit/compliance). GUARD OFFSET VOLTAGE: <4mV (current <10mA). SMU INSTRUMENTS Current Source Specifications CURRENT PROGRAMMING ACCURACY Accuracy (1 Year) Programming 23C 5C Range Resolution (% rdg. + amps) 1 nA 20 fA 0.15% + 2 pA 10 nA 200 fA 0.15% + 5 pA 100 nA 2 pA 0.06% + 50 pA 1 A 20 pA 0.03% + 700 pA 10 A 200 pA 0.03% + 5 nA 100 A 2 nA 0.03% + 60 nA 1 mA 20 nA 0.03% + 300 nA 10 mA 200 nA 0.03% + 6 A 100 mA 2 A 0.03% + 30 A 20 A 0.05% + 1.8 mA 1 A 5 50 A 0.06% + 4 mA 1.5 A 5 200 A 0.5 % + 40 mA (typical) 10 A 5, 6 Typical Noise (peak-peak) 0.1Hz-10Hz 800 fA 2 pA 5 pA 25 pA 60 pA 3 nA 6 nA 200 nA 600 nA 70 A 150 A TEMPERATURE COEFFICIENT (0-18C and 28-50C) 7: (0.15 x accuracy specification)/C. Applicable for normal mode only. Not applicable for high capacitance mode. MAXiMUM OUTPUT POWER AND SOURCE/SINK LIMITS 8: 30.3W per channel maximum. 1.515A @ 20V, 101mA @ 200V, four quadrant source or sink operation. CURRENT REGULATION: Line: 0.01% of range. Load: (0.01% of range + 100pA). VOLTAGE LIMIT/COMPLIANCE 9: Bipolar voltage limit (compliance) set with a single value. Minimum value is 20mV. Accuracy is the same as voltage source. OVERSHOOT: <0.1% typical (step size = 10% to 90% of range, resistive load, maximum current limit/compliance; see Current Source Output Settling Time for additional test conditions). TRANSIENT RESPONSE TIME: <70s for the output to recover to within 0.1% for a 10% to 90% step change in load. VOLTAGE SOURCE OUTPUT SETTLING TIME: Time required to reach within 0.1% of final value after source level command is processed on a fixed range. Range Settling Time 200 mV <50 s (typical) 2 V <50 s (typical) 20 V <110 s (typical) 200 V <700 s (typical) CURRENT SOURCE OUTPUT SETTLING TIME: Time required to reach within 0.1% of final value after source level command is processed on a fixed range. Values below for Iout * R load = 2V unless noted. Current Range Settling Time 1.5 A - 1 A <120 s (typical) (R load > 6W) 100 mA - 10 mA <80 s (typical) 1 mA <100 s (typical) 100A <150 s (typical) 10A <500 s (typical) 1A <2 ms (typical) 100 nA <20 ms (typical) 10 nA <40 ms (typical) 1 nA <150 ms (typical) DC FLOATING VOLTAGE: Output can be floated up to 250VDC. REMOTE SENSE OPERATING RANGE 10: Maximum voltage between HI and SENSE HI = 3V . Maximum voltage between LO and SENSE LO = 3V . VOLTAGE OUTPUT HEADROOM: 200V Range: Max. output voltage = 202.3V - total voltage drop across source leads (maximum 1W per source lead). 20V Range: Max. output voltage = 23.3V - total voltage drop across source leads (maximum 1W per source lead). OVER TEMPERATURE PROTECTION: Internally sensed temperature overload puts unit in standby mode. VOLTAGE SOURCE RANGE CHANGE OVERSHOOT: <300mV + 0.1% of larger range (typical). Overshoot into a 200kW load, 20MHz BW. CURRENT SOURCE RANGE CHANGE OVERSHOOT: <5% of larger range + 300mV/R load (typical - With source settling set to SETTLE_SMOOTH_100NA). See Current Source Output Settling Time for additional test condtions. PULSE SPECIFICATIONS Maximum Current Limit 100 mA @ 200 V 1.5 A @ 20 V 1 A @ 180 V 1 A @ 200 V 10 A @ 5 V Region 1 1 2 3 13 4 Maximum Pulse Width 11 DC, no limit DC, no limit 8.5 ms 2.2 ms 1 ms Maximum Duty Cycle 12 100% 100% 1% 1% 2.2% MINIMUM PROGRAMMABLE PULSE WIDTH 14, 15: 100s. NOTE: Minimum pulse width for settled source at a given I/V output and load can be longer than 100s. Pulse width programming resolution: 1s. Pulse width programming accuracy 15: 5s. pulse width jitter: 50s (typical). Quadrant Diagram: +10A 4 +1.5A +1A 3 -1A -1.5A 3 2 +0.1A 0A -0.1A 2 DC 1 Pulse 2 2 3 Pulse 3 4 -10A -200V -180V -20V -5V 0V +5V 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence +20V +180V +200V Pulse Series 2600B specifications 2634B, 2635B, 2636B System SourceMeter(R) SMU Instruments SOURCE SPECIFICATIONS (continued) METER SPECIFICATIONS NOTES VOLTAGE MEASUREMENT ACCURACY 16, 17 Range 200 mV 2 V 20 V 200 V Range *100 pA 22, 23 1 nA 22, 24 10 nA 100 nA 1 A 10 A 100 A 1 mA 10 mA 100 mA 1 A 1.5 A 10 A 25 Start toff 10% 10% ton toff 12. Thermally limited in sink mode (quadrants II and IV) and ambient temperatures above 30C. See power equations in the Reference Manual for more information. 13. Voltage source operation with 1.5 A current limit. 14. Typical performance for minimum settled pulse widths: Source Settling Source Value Load (% of range) Min. Pulse Width 5V 20 V 180 V 200 V (1.5 A Limit) 100 mA 1A 1A 10 A 0.5 W 200 W 180 W 200 W 200 W 200 W 180 W 0.5 W 1% 0.2% 0.2% 0.2% 1% 1% 0.2% 0.5% 300 s 200 s 5 ms 1.5 ms 200 s 500 s 5 ms 300 s Typical tests were performed using remote operation, 4W sense, and best, fixed measurement range. For more information on pulse scripts, see the Series 2600B Reference Manual. 15. Times measured from the start of pulse to the start off-time; see figure below. Bias Level 10% 10% ton toff Voltage Burden 21 <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV <1 mV Accuracy (1 Year) 23C 5C (% rdg. + amps) 0.15% + 120 fA 0.15% + 240 fA 0.15% + 3 pA 0.06% + 40 pA 0.025% + 400 pA 0.025% + 1.5 nA 0.02% + 25 nA 0.02% + 200 nA 0.02% + 2.5 A 0.02% + 20 A 0.03% + 1.5 mA 0.05% + 3.5 mA 0.4 % + 25 mA Contact Check 28 (Not available on Model 2634B) Maximum Measurement Time to Memory For 60Hz (50Hz) Speed Start toff Start ton Default Display Resolution 20 0.1 fA 1 fA 10 fA 100 fA 1 pA 10 pA 100 pA 1 nA 10 nA 100 nA 1 A 1 A 10 A * 100 pA range not available on Model 2634B. Current Measure Settling Time (Time for measurement to settle after a Vstep) 26: Time required to reach within 0.1% of final value after source level command is processed on a fixed range. Values for Vout = 2V unless noted. Current Range: 1mA. Settling Time: <100s (typical). TEMPERATURE COEFFICIENT (0-18C and 28-50C) 27: (0.15 x accuracy specfication)/C. Applicable for normal mode only. Not applicable for high capacitance mode. Pulse Level 90% Accuracy (1 Year) 23C 5C (% rdg. + volts) 0.015% + 225 V 0.02% + 350 V 0.015% + 5 mV 0.015% + 50 mV CURRENT MEASUREMENT ACCURACY 17 90% Bias Level Input Resistance >1014 W >1014 W >1014 W >1014 W TEMPERATURE COEFFICIENT (0-18C and 28-50C) 19: (0.15 x accuracy specification)/C. Applicable for normal mode only. Not applicable for high capacitance mode. Pulse Level Start ton Default Display Resolution 18 100 nV 1 V 10 V 100 V Series 2600B specifications 1. Add 50V to source accuracy specifications per volt of HI lead drop. 2. High Capacitance Mode accuracy is applicable at 23C 5C only. 3. Full power source operation regardless of load to 30C ambient. Above 30C and/or power sink operation, refer to "Operating Boundaries" in the Series 2600B Reference Manual for additional power derating information. 4. For sink mode operation (quadrants II and IV), add 0.06% of limit range to the corresponding current limit accuracy specifications. Specifications apply with sink mode operation enabled. 5. Full power source operation regardless of load to 30C ambient. Above 30C and/or power sink operation, refer to "Operating Boundaries" in the Series 2600B Reference Manual for additional power derating information. 6. 10A range accessible only in pulse mode. 7. High Capacitance Mode accuracy is applicable at 23C 5C only. 8. Full power source operation regardless of load to 30C ambient. Above 30C and/or power sink operation, refer to "Operating Boundaries" in the Series 2600B Reference Manual for additional power derating information. 9. For sink mode operation (quadrants II and IV), add 10% of compliance range and 0.02% of limit setting to corresponding voltage source specification. For 200mV range add an additional 120mV of uncertainty. 10. Add 50V to source accuracy specifications per volt of HI lead drop. 11. Times measured from the start of pulse to the start off-time; see figure below. Accuracy (1 Year) 23C 5C (%rdg. + ohms) FAST 1 (1.2) ms 5% + 10 W MEDIUM 4 (5) ms 5% + 1 W 36 (42) ms 5% + 0.3 W SLOW ADDITIONAL METER SPECIFICATIONS Maximum LOAD IMPEDANCE: Normal Mode: 10nF (typical). High Capacitance Mode: 50F (typical). COMMON MODE VOLTAGE: 250VDC. COMMON MODE ISOLATION: >1GW, <4500pF. OVERRANGE: 101% of source range, 102% of measure range. MAXIMUM SENSE LEAD RESISTANCE: 1kW for rated accuracy. SENSE INPUT IMPEDANCE: >1014W. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence SMU INSTRUMENTS Series 2600B specifications 2634B, 2635B, 2636B 2634B, 2635B, 2636B System SourceMeter(R) SMU Instruments METER SPECIFICATIONS (continued) GENERAL 16. Add 50V to source accuracy specifications per volt of HI lead drop. 17. De-rate accuracy specifications for NPLC setting <1 by increasing error term. Add appropriate % of range term using table below. Series 2600B specifications NPLC Setting 0.1 0.01 0.001 200mV Range 0.01% 0.08% 0.8 % 2V-200V Ranges 0.01% 0.07% 0.6 % 100nA Range 0.01% 0.1% 1% 1A-1.5A Ranges 0.01% 0.05% 1.1 % 18. Applies when in single channel display mode. 19. High Capacitance Mode accuracy is applicable at 23C 5C only. 20. Applies when in single channel display mode. 21. Four-wire remote sense only and with current meter mode selected. Voltage measure set to 200mV or 2V range only. 22. 10-NPLC, 11-Point Median Filter, <200V range, measurements made within 1 hour after zeroing. 23C 1C 23. Under default specification conditions: (0.15% + 750fA). 24. Under default specification conditions: (0.15% + 1pA). 25. 10A range accessible only in pulse mode. 26. Delay factor set to 1. Compliance equal to 100mA. 27. High Capacitance Mode accuracy is applicable at 23C 5C only. 28. Includes measurement of SENSE HI to HI and SENSE LO to LO contact resistances. HIGH CAPACITANCE MODE 29, 30, 31 Voltage Source Output Settling Time: Time required to reach within 0.1% of final value after source level command is processed on a fixed range. Current limit = 1A. Voltage Source Range Settling Time with Cload = 4.7F 200 mV 600 s (typical) 2 V 600 s (typical) 20 V 1.5 ms (typical) 200 V 20 ms (typical) Current Measure Settling Time: Time required to reach within 0.1% of final value after voltage source is stabilized on a fixed range. Values below for Vout = 2V unless noted. Current Measure Range Settling Time 1.5 A - 1 A <120 s (typical) (R load >6W) 100 mA - 10 mA <100 s (typical) 1 mA < 3 ms (typical) 100A < 3 ms (typical) 10A < 230 ms (typical) 1A < 230 ms (typical) Capacitor Leakage Performance Using HIGH-C scripts 32: Load = 5F||10MW. Test: 5V step and measure. 200ms (typical) @ 50nA. Mode Change Delay: 100A Current Range and Above: Delay into High Capacitance Mode: 10ms. Delay out of High Capacitance Mode: 10ms. 1A and 10A Current Ranges: Delay into High Capacitance Mode: 230ms. Delay out of High Capacitance Mode: 10ms. Voltmeter Input Impedance: 30GW in parallel with 3300pF. Noise, 10Hz-20MHz (20V Range): <30mV peak-peak (typical). Voltage Source Range Change Overshoot (for 20V range and below): <400mV + 0.1% of larger range (typical). Overshoot into a 200kW load, 20MHz BW. NOTES SMU INSTRUMENTS 1A-100mA Ranges 0.01% 0.05% 0.5 % 29. High Capacitance Mode specifications are for DC measurements only. 30. 100nA range and below are not available in high capacitance mode. 31. High Capacitance Mode utilizes locked ranges. Auto Range is disabled. 32. Part of KI Factory scripts. See reference manual for details. IEEE-488: IEEE-488.1 compliant. Supports IEEE-488.2 common commands and status model topology. USB Control (rear): USB 2.0 device, TMC488 protocol. RS-232: Baud rates from 300bps to 115200bps. Programmable number of data bits, p arity type, and flow control (RTS/CTS hardware or none). Ethernet: RJ-45 connector, LXI Class C, 10/100BT, no auto MDIX. EXPANSION INTERFACE: The TSP-Link expansion interface allows TSP enabled instruments to trigger and communicate with each other. (Not available on Model 2614B.) Cable Type: Category 5e or higher LAN crossover cable. Length: 3 meters maximum between each TSP enabled instrument. LXI Compliance: LXI Class C 1.4. LXI Timing: Total Output Trigger Response Time: 245s min., 280s typ., (not specified) max. Receive LAN[0-7] Event Delay: Unknown. Generate LAN[0-7] Event Delay: Unknown. DIGITAL I/O INTERFACE: (Not available on Model 2614B) +5V Pins Solid State Fuse Digital I/O Pin 100 +5VDC (on DIGITAL I/O connector) 5.1k (on DIGITAL I/O connector) Read by firmware Written by firmware GND Pin (on DIGITAL I/O connector) Rear Panel Connector: 25-pin female D. Input/Output Pins: 14 open drain I/O bits. Absolute Maximum Input Voltage: 5.25V. Absolute Minimum Input Voltage: -0.25V. Maximum Logic Low Input Voltage: 0.7V, +850A max. Minimum Logic High Input Voltage: 2.1V, +570A. Maximum Source Current (flowing out of Digital I/O bit): +960A. Maximum Sink Current @ Maximum Logic Low Voltage (0.7V): -5.0mA. Absolute Maximum Sink Current (flowing into Digital I/O pin): -11mA. 5V Power Supply Pins: Limited to 250mA total for all three pins, solid state fuse protected. Safety Interlock Pin: Active high input. >3.4V @ 24mA (absolute maximum of 6V) must be externally applied to this pin to ensure 200V operation. This signal is pulled down to chassis ground with a 10kW resistor. 200V operation will be blocked when the INTERLOCK signal is <0.4V (absolute minimum -0.4V). See figure below: Coil Resistance 145 10% INTERLOCK Pin (on DIGITAL I/O connector) Read by firmware +220V Supply -220V Supply 10k Chassis Ground * To output stage Rear Panel USB File System (Front): USB 2.0 Host: Mass storage class device. POWER SUPPLY: 100V to 250VAC, 50-60Hz (auto sensing), 240VA max. COOLING: Forced air. Side intake and rear exhaust. One side must be unobstructed when rack mounted. EMC: Conforms to European Union Directive 2004/108/EEC, EN 61326-1. SAFETY: Conforms to European Union Directive 73/23/EEC, EN 61010-1, and UL 61010-1. DIMENSIONS: 89mm high x 213mm wide x 460mm deep (31/2 in x 838 in x 171/2 in). Bench Configuration (with handle and feet): 104mm high x 238mm wide x 460mm deep (418 in x 938 in x 171/2 in). WEIGHT: 2635B: 4.75kg (10.4 lbs). 2634B, 2636B: 5.50kg (12.0 lbs). See pages 23 and 24 for measurement speeds and other specifications. ENVIRONMENT: For indoor use only. Altitude: Maximum 2000 meters above sea level. Operating: 0-50C, 70% R.H. up to 35C. Derate 3% R.H./C, 35-50C. Storage: -25C to 65C. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 2600B specifications NOTES Series 2600B System SourceMeter(R) SMU Instruments Applicable to Models 2601B, 2602B, 2604B, 2611B, 2612B, 2614B, 2634B, 2635B, and 2636B. Measurement Speed Specifications 1, 2, 3 Trigger Origin Internal Digital I/O Internal Digital I/O Internal Digital I/O Internal Digital I/O Measure To Memory Using User Scripts 20000 (20000) 8100 (8100) 5000 (4000) 3650 (3200) 580 (490) 560 (470) 59 (49) 58 (48) Measure To Gpib Using User Scripts 10500 (10500) 7100 (7100) 4000 (3500) 3400 (3000) 560 (475) 450 (460) 59 (49) 58 (49) Source Measure To Memory Using User Scripts 7000 (7000) 5500 (5500) 3400 (3000) 3000 (2700) 550 (465) 545 (460) 59 (49) 59 (49) Source Measure To Gpib Using User Scripts 6200 (6200) 5100 (5100) 3200 (2900) 2900 (2600) 550 (460) 540 (450) 59 (49) 59 (49) Maximum SINGLE MEASUREMENT RATES (operations per second) FOR 60Hz (50Hz): A/D Converter Speed Trigger Origin Measure To Gpib Source Measure To Gpib Source Measure Pass/Fail To Gpib 0.001 NPLC 0.01 NPLC 0.1 NPLC 1.0 NPLC Internal Internal Internal Internal 1900 (1800) 1450 (1400) 450 (390) 58 (48) 1400 (1400) 1200 (1100) 425 (370) 57 (48) 1400 (1400) 1100 (1100) 425 (375) 57 (48) Maximum Measurement RANGE CHANGE RATE: <150s for ranges >10A, typical. When changing to or from a range 1A, maximum rate is <450s, typical. Maximum SOURCE Range CHANGE RATE: <2.5ms for ranges >10A, typical. When changing to or from a range 1A, maximum rate is <5.2ms, typical. Maximum SOURCE FUNCTION CHANGE RATE: <1ms, typical. COMMAND PROCESSING TIME: Maximum time required for the output to begin to change following the receipt of the smux. source.levelv or smux.source.leveli command. <1ms typical. Source Measure To Memory Using Sweep API 12000 (12000) 11200 (11200) 4200 (3700) 4150 (3650) 575 (480) 570 (480) 59 (49) 59 (49) Source Measure To Gpib Using Sweep API 5900 (5900) 5700 (5700) 3100 (2800) 3050 (2775) 545 (460) 545 (460) 59 (49) 59 (49) TRIGGERING AND SYNCHRONIZATION SPECIFICATIONS 1 Triggering: Trigger in to trigger out: 0.5s, typical. Trigger in to source change:2 10 s, typical. Trigger Timer accuracy: 2s, typical. Source change2 after LXI Trigger: 280s, typical. Synchronization: Single-node synchronized source change:4 <0.5s, typical. Multi-node synchronized source change:4 <0.5s, typical. Series 2600B specifications A/D Converter Speed 0.001 NPLC 0.001 NPLC 0.01 NPLC 0.01 NPLC 0.1 NPLC 0.1 NPLC 1.0 NPLC 1.0 NPLC NOTES 1. TSP-Link not available on Models 2604B, 2614B, and 2634B. 2. Fixed source range, with no polarity change. NOTES 1. Tests performed with a 2602B, 2612B, or 2636B on Channel A using the following equipment: PC Hardware (Pentium(R) 4 2.4GHz, 512MB RAM, National Instruments PCI-GPIB). Driver (NI-486.2 Version 2.2 PCI-GPIB). Software (Microsoft(R) Windows(R) 2000, Microsoft Visual Studio 2005, VISA version 4.1). 2. Exclude current measurement ranges less than 1mA. 3. 2635B/2636B with default measurement delays and filters disabled. SMU INSTRUMENTS Series 2600B specifications Maximum SWEEP OPERATION RATES (operations per second) FOR 60Hz (50Hz): 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 2600B System SourceMeter(R) SMU Instruments Applicable to Models 2601B, 2602B, 2604B, 2611B, 2612B, 2614B, 2634B, 2635B, and 2636B. FRONT PANEL INTERFACE: Two-line vacuum fluorescent display (VFD) with keypad and rotary knob. Display: Show error messages and user defined messages Display source and limit settings Show current and voltage measurements View measurements stored in dedicated reading buffers Keypad Operations: Change host interface settings Save and restore instrument setups Load and run factory and user defined test scripts (i.e. sequences) that prompt for input and send results to the display Store measurements into dedicated reading buffers PROGRAMMING: Embedded Test Script Processor (TSP) accessible from any host interface. Responds to individual instrument control commands. Responds to high speed test scripts comprised of instrument control commands and Test Script Language (TSL) statements (e.g. branching, looping, math, etc.). Able to execute high speed test scripts stored in memory without host intervention. Minimum Memory Available: 16MB (approximately 250,000 lines of TSL code). Test Script Builder: Integrated development environment for building, running, and managing TSP scripts. Includes an instrument console for communicating with any TSP enabled instrument in an interactive manner. Requires: VISA (NI-VISA included on CD) Pentium III 800MHz or faster personal computer Microsoft .NET Framework (included on CD) Microsoft Windows 98, NT, 2000, or XP Keithley I/O Layer (included on CD) Software Interface: TSP Express (embedded), Direct GPIB/VISA, READ/WRITE for VB, VC/C++, LabVIEW, LabWindows/CVI, etc. READING BUFFERS: Dedicated storage area(s) reserved for measurement data. Reading buffers are arrays of measurement elements. Each element can hold the following items: Measurement Source setting (at the time the measurement was taken) Measurement status Range information Timestamp Two reading buffers are reserved for each SourceMeter channel. Reading buffers can be filled using the front panel STORE key and retrieved using the RECALL key or host interface. Buffer Size, with timestamp and source setting: >60,000 samples. Buffer Size, without timestamp and source setting: >140,000 samples. Accuracy: 100ppm. SYSTEM EXPANSION: The TSP-Link expansion interface allows TSP enabled instruments to trigger and communicate with each other. Not applicable for Models 2604B, 2614B, and 2634B. See figure below: Each SourceMeter SMU instrument has two TSP-Link connectors to facilitate chaining instruments together. Once SourceMeter SMU instruments are interconnected via TSP-Link, a computer can access all of the resources of each SourceMeter SMU instrument via the host interface of any SourceMeter SMU instrument. A maximum of 32 TSP-Link nodes can be interconnected. Each SourceMeter SMU instrument consumes one TSP-Link node. TIMER: Free running 47-bit counter with 1MHz clock input. Reset each time instrument powers up. Rolls over every 4 years. Timestamp: TIMER value automatically saved when each measurement is triggered. Resolution: 1s. SERVICES AVAILABLE FOR ALL SERIES 2600B MODELS ACCESSORIES AVAILABLE Software ACS-BASIC Component Characterization Software SMU INSTRUMENTS Rack Mount Kits 4299-1 Single Rack Mount Kit with front and rear support 4299-2 Dual Rack Mount Kit with front and rear support 4299-5 1U Vent Panel Cables and Connectors 2600-BAN Banana Test Leads/Adapter Cable. For a single 2601B/2602B/2604B/2611B/261 2B/2614B SMU instrument channel 2600-KIT Extra screw terminal connector, strain relief, and cover for a single SourceMeter channel (one supplied with 2601B/2611B, two with 2602B/2604B/2612B/2614B) 2600-FIX-TRIAX Phoenix-to-Triax Adapter for 2 wire sensing 2600-TRIAX Phoenix-to-Triax Adapter for 4 wire sensing 7078-TRX-* 3-Slot, Low Noise Triax Cable, 0.3m-6.1m. For use with 2600-TRIAX Adapter 7078-TRX-GND 3-Slot male triax to BNC adapter (guard removed) 7709-308A Digital I/O Connector (model specific) 8606 High Performance Modular Probe Kit. For use with 2600B-BAN GPIB Interfaces and Cables 7007-1 Double Shielded GPIB Cable, 1m (3.3 ft.) 7007-2 Double Shielded GPIB Cable, 2m (6.6 ft.) KPCI-488LPA IEEE-488 Interface/Controller for the PCI Bus Extended Warranties 26xxB-EW 1 Year Factory Warranty extended to 2 years 26xxB-3Y-EW 1 Year Factory Warranty extended to 3 years 26xxB-5Y-EW 1 Year Factory Warranty extended to 5 years Digital I/O, 2600-TLINK CA-126-1A CA-180-3A CALIBRATION CONTRACTS C/26xxB-3Y-STD 3 Calibrations within 3 years C/26xxB-5Y-STD 5 Calibrations within 5 years C/26xxB-3Y-DATA 3 Calibrations within 3 years and includes calibration data before and after adjustment C/26xxB-5Y-DATA 5 Calibrations within 5 years and includes calibration data before and after adjustment C/26xxB-3Y-17025 3 IS0-17025 accredited calibrations within 3 years C/26xxB-5Y-17025 5 IS0-17025 accredited calibrations within 5 years Trigger Link, and TSP-Link Digital I/O to TLINK Adapter Cable, 1m Digital I/O and Trigger Cable, 1.5m CAT5 Crossover Cable for TSP-Link and direct Ethernet connection (two supplied) TEST FIXTURES 8101-PIV DC, Pulse I-V and C-V Component Test Fixture 8101-4TRX 4 Pin Transistor Fixture LR8028 Component Test Fixture - Optimized for device testing at up to 200V/1A Switching Series 3700A 707B DMM/Switch Systems Semiconductor Switching Matrix Mainframe Calibration and Verification 2600-STD-RES Calibration Standard 1GW Resistor for Models 2634B, 2635B, and 2636B 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 2600B specifications Series 2600B specifications SUPPLEMENTAL INFORMATION