C-73
Connector type/2 outputs
DC-AC Inverter
・Allspecificationsaresubjecttochangewithoutnotice.
■Features
2 outputs
Usable in a wide range of temperatures
●Applicablepanelsize*:5to6inches
Withbrightnesscontrolfunction(PulseWidthModulationDimming)
●Withshutdownfunction.
●Withasensingfunctionforrunningoutoflamp(alarmoutput).
●Inthehigh-voltagegenerator(aterminalandapattern),ananti-dust
measurebysiliconeapplicationistaken.
(Notice)Applicablepanelsizebecomesastandard.
CXA-0462
CXA-0502Specifications (Please refer to each specification before use)
■Applications
F A MED MEASURE
Dimming
Function Yes
Operating
Temperature -30to+80
Storage
Temperature -30to+85
Operating
Humidity Ratio RH% 95max.
Safety
Standard
Weight g 22typ.
Dimensions
(WxDxH)
mm 110x22x8.5(*3)
Fused Input Yes
Remote ON / OFF
Yes
Alarm Signal
Function
Yes
Shutdown
Function
Yes
Silicone
Coating on
High Voltage
Area
Yes
Item Unit Symbol Specifi cation Condition
min typ max Vin(V) Vrmt(V) Vbr(V) Rbr(kΩ) Ta(℃)
RL1,2(kΩ)
Remarks
Output Current mArms
lout 1, 2
(Maximum
dimmer)
4.5 5 5.5
12±1. 2
50 -
-30
to
+80
65 Voltage
dimmer (*1)
4.5 5 5.5
12±1.2
5-0
-30
to
+80
65 Volume
dimmer (*1)
lout 1, 2
(
Minimum
dimmer
)
1.9 2.6 3.3
12±1.2
52.5 -
-30
to
+80
65 Voltage
dimmer (*1)
1.9 2.6 3.3
12±1.2
5-50
-30
to
+80
65 Volume
dimmer (*1)
Input Current mA Iin1 - 440 1000
12±1.2
50 -
-30
to
+80
65 Remote ON
mA Iin2 - - 1
12±1.2
00 -
-30
to
+80
65 Remote OFF
Oscillatory
Frequency
kHz Freq1 45 50 55
12±1.2
50 -
-30
to
+80
65
Hz
Freq2(Dutyfrequency)
230 255 280
12±1.2
52.5 -
-30
to
+80
65
Open Circuit
Voltage Vrms Vopen 1400 1600 1800
12±1.2
50 -
-30
to
+80
∞/∞ Open load
AlarmSignal V Vst
4.5 5.1 5.5
12±1.2
50 -
-30
to
+80
∞/65
In case of
lamp anomaly
(*2)
4.5 5.1 5.5
12±1. 2
50 -
-30
to
+80
65/
In case of
lamp anomaly
(*2)
-00.5
12±1. 2
50 -
-30
to
+80
65 On a normal
operation (*2)
Electrical Characteristics
Other Specifications
(*1) Please refer to the connection diagram for details of a dimming method.
(*2) Please refer to the connection diagram for details of alarm output.
(*3) These dimensions are indicated the maximum only H. Others are typical values.
Dimming/Connector Type
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
■
Conformity to RoHs Directive
C-74
Connector type/2 outputs
DC-AC Inverter
・Allspecificationsaresubjecttochangewithoutnotice.
CXA-0462
Outline Drawing
Connector
No. Component name Type name Qty Remarks
Recommended suitable connector
Printed circuit board PCB Composite (CEM-3) 1 UL94V-0t=1.0 -
Input connector CN1
53261-0871
1Molex 51021-0800
Output connector CN2
SM03(7-D1)B-BHS-1-TB(LF)(SN)
1
J.S.T Mfg., Co., Ltd
BHR-04VS-1
OutputsideCN2
TerminalNo.
Symbol Rating Remarks
CN2-1 VHIGH1 370Vrms Output 1
CN2-2 VHIGH2 370Vrms Output 2
CN2-3 N.C. N.C.
CN2-4 VLOW (2V) Output 1, 2 return
Terminal Number & Function
Input side CN1
TerminalNo.
Symbol Rating Remarks
CN1-1 Vin 12± 1.2V Power source input
CN1-2
CN1-3 GND 0V Ground
CN1-4
CN1-5 Vrmt
0V/2.5VtoVin
Remote terminal
0to0.4V:OFF
     
2.5VtoVin:ON
CN1-6 Vbr1/Rbr1
0to2.5V/0to50kΩ
Dimmer terminal 1
CN1-7 Vbr2/Rbr2
GND/0to50kΩ
Dimmer terminal 2
CN1-8
Vst(output)
0V/5V Alarm output
Lump open: 5V
1
CN2
Label display example
Product name, Lot No., country of origin, TDK−Lambda logo
Silicon
High voltage generating area (Complete area of 60mm from board end panel)
*From high-voltage generator, please secure space distance more than 3mm in top and bottom right and left.
Unit: mm
C-75
Connector type/2 outputs
DC-AC Inverter
・Allspecificationsaresubjecttochangewithoutnotice.
Connections
Operate as follows by switching a SW1.
Operates as follows depending on ON-OFF of SW3 to 5.
Unit operates
Operates
Does not operate
Operates alarm output
(CN1-8)
Operates (outputs 5V)
Does not operate (outputs 0V)
Operate as follows by switching a SW2.
Voltage dimmer
Vbr = 0 VQ 2.5V
(0V: Maximum brightness)
Volume dimmer
VR = 0 VQ 50kΩ
(0Ω: Maximum brightness)
Unit operates
RL1, 2: Load resistance (7W min.)