3
-
phase and single phase pump control relay
-
35 mm HPC Part number 84874200
Allows control and monitoring of single phase and 3-phase pumps
Monitors phase sequence and phase failure
Checks for undercurrent to protect against running dry
Checks for overcurrent to protect against overload
Digitial inputs for operation control logic
True RMS current measurement
Part numbers
Specifications
Type
Measurement ranges
Nominal voltage (V)
84874200
HPC
1A→10AinDC
208→480VAC3-phase 230 V monophase
Supply voltage Un
208 V.480 V 3-phase *230 V monophase
Voltage supply tolerance
-12 % / +10 %
Operating range
183→528VAC
AC supply voltage frequency
50/60 Hz
±
10 %
Galvanic isolation of power supply/measurement
No
Power consumption at Un
5 VA in AC
Immunity from micro power cuts
500 ms
Measurement ranges
1→10AAC
E1
-L2:1→10A
Input resistance
E1
-L2 : 0,01
Ω
Permanent overload at 25 °C
E1
-L2 : 11 A
Pulse overload < 1 sec at 25 °C
E1
-L2 : 50 A
Frequency of measured signal
50 / 60 Hz :
±
10 %
Max. measuring cycle time
150 ms/True RMS measurement
Adjustment of upper threshold
1→10A
Adjustment of lower threshold
1→10A
Fixed hysteresis
5 % of displayed treshold
Display precision
±
10 % of full scale
Repetition accuracy with constant parameters
±
0,5 %
Measuring error with voltage drift
< ±
1 % across the whole range
Measuring error with temperature drift
±
0,05 % / °C
Delays on power up (Ti)
1→60s(0,+10%)
Delay on thresold crossing Tt
0,1→10s(0,+10%)
Repetition accuracy with constant parameters
±
1 %
Reset time
2 s
Y2 minimum reset time
300 ms
Delay on pick
-up
500 ms
Alarm on delay time max.
300 ms
Type of output
1 single pole changeover relay
Type of contacts
No cadmium
Maximum breaking voltage
250 V AC/DC
Max. breaking current
5 A AC/DC
Min. breaking current
10 mA / 5 V DC
Electrical life (number of operations)
1 x 105
Breaking capacity (resistive)
1250 VA AC
Maximum rate
360 operations/hour at full load
Operating categories acc. to IEC/EN 60947
-5-1
AC 12, AC 13, AC 14, AC 15, DC 12, DC 13
Mechanical life (operations)
DC 14, 30 x 10
6
Nominal insulation voltage IEC/EN 60664
-1
400 V
Insulation coordination (IEC/EN 60664
-1)
Overvoltage category III : degree of pollution 3
Rated impulse withstand voltage (IEC/EN 60664
-1)
4 kV (1,2 / 50
μ
s)
Dielectric strength (IEC/EN 60664
-1)
2 kV AC 50 Hz 1 min
Insulation resistance (IEC/EN 60664
-1)
> 500 M
Ω
500 V DC
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
Accessories
Overview
The pump controller can operate on a single phase or 3-phase network. It provides 3 functions in one unit :
Checking current,
Checking phase presence (in 3-phase mode),
Checking phase sequence (in 3-phase mode).
It has two operating modes whose purposes is to control a pump based on two external signal inputs (Y1 Y2).
These two signals are controlled by volt-free contacts.
Faults are signalled via LEDs, distinguishing the origin of the fault.
Operating principle
HPC
Selecting the operating mode
A rotary switch on the front is used to select :
-
single control mode,
-
dual control mode,
-
single
-phase or 3-phase network.
The position of this selector switch is only taken into account when the unit is powered up.
If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the mode selected on energisation prior to the change of position.
The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation.
Display power supply
Green LED
Display relay
Yellow LED
"Fault" indication
Yellow LED
Casing
35 mm
Mounting
On 35 mm symmetrical DIN rail, IEC/EN 60715
Mounting position
All positions
Material : enclosure plastic type VO to UL94 standard
Incandescent wire test according to IEC 60695-2-
11 & NF EN 60695
-2-11
Protection (IEC/EN 60529)
Terminal block : IP 20
Casing : IP 30
Weight
100 g
Connecting capacity IEC/EN 60947
-1
Rigid : 1 x 4
2 - 2 x 2.52
mm
2
1 x 11 AWG - 2 x 14 AWG
Flexible with ferrules : 1 x 2.52 - 2 x 1.52
mm
2
1 x 14 AWG - 2 x 16 AWG
Max. tightening torques
IEC/EN 60947
-1
0,6→1Nm/5,3→8,8Lbf.In
Operating temperature IEC/EN 60068
-2
-
20→+50°C
Storage temperature IEC/EN 60068
-2
-
40→+70°C
Humidity IEC/EN 60068
-2-30
2 x 24 hr cycle 95 % RH max. without condensation 55 °C
Vibrations according to IEC/EN60068
-2-6
10→150Hz,A=0.035mm
Shocks IEC/EN 60068
-2-6
5 g
Marking
CE (LVD) 73/23/EEC
-
EMC 89/336/EEC
Product standard
NF EN 60255
-
6 / IEC 60255
-
6 / UL 508 / CSA C22.2 N°14
Electromagnetic compatibility
Immunity EN 61000
-6-
2/IEC 61000
-6-2
Emission EN 61000
-6-
4/EN 61000
-6-3
IEC 61000
-6-
4/IEC 61000
-6-3
Emission EN 55022 class B
Certifications
UL, CSA, GL
Conformity with environmental directives
RoHS, WEEE
Description
Code
Removable sealable cover for 35 mm casing
84800001
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
This mode is for controlling a pump based on one external signal (Y1).
The relay output is closed when the signal is present at Y1 (contact closed).
After a fault the relay remains open (even if the current returns to normal) and the module can be reclosed in two different ways :
- By a reset : cutting of power supply,
- Or by a reset through pressing an external contact (pushbutton for example) entering the second control input (Y2).
This mode is for controlling a pump based on two external signals (Y1 and Y2).
The output relay closes when both input signals are present (Y1 and Y2 closed).
It will open as soon as either of these two signals is absent.
If the controller is configured in single phase, it monitors the current drawn by the pump.
If the controller is configured in 3-phase, it monitors current, phase sequence and phase failure.
If a phase fault is detected, the output relay opens immediately.
On energisation, the output relay cannot be closed if there is a phase fault or phase failure.
N
o
Legend
Current fault
Relay
Fault monitoring inhibit time on pump start
-
up (Ti)
Delay timing in case of fault (Tt)
N
o
Legend
Current fault
Relay
Fault monitoring inhibit time on pump start
-
up (Ti)
Delay timing in case of fault (Tt)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
Current control
The under and overcurrent values are set by two independent potentiometers graduated from 1 to 10 A.
In case of a control error (low threshold higher than high threshold), the output relay opens and all the
LEDs flash to signal the error.
If a current fault occurs (under or overcurrent) the relay opens if the fault persists
beyond the preset threshold delay. When the current returns to a correct value, the output relay remains open. It can only be closed by a reset : either by de-energisation or by closing on external
contact Y2 (in single control mode)
An inhibit delay (Ti) on energisation allows current peaks due to start-up of the motor to be disregarded.
Current control
The under and overcurrent values are set by two independent potentiometers graduated from 1 to 10 A.
In case of a control error (low threshold higher than high threshold), the output relay opens and all the
LEDs flash to signal the error.
If a current fault occurs (under or overcurrent) the relay opens if the fault persists
beyond the preset threshold delay. When the current returns to a correct value, the output relay remains open. It can only be closed by a reset : either by de-energisation or by closing on external
contact Y2 (in single control mode)
An inhibit delay (Ti) on energisation allows current peaks due to start-up of the motor to be disregarded.
N
o
Legend
Overcurrent
Hysteresis
Relay
Fault monitoring inhibit time on pump start
-
up (Ti)
Delay timing in case of fault (Tt)
N
o
Legend
Undercurrent
Hysteresis
Relay
Fault monitoring inhibit time on pump start
-
up (Ti)
Delay timing in case of fault (Tt)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
mm
N
o
Legend
100 mA fast-blow fuse or cut-out
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
N
o
Legend
100 mA fast-blow fuse or cut-out
N
o
Legend
100 mA fast-blow fuse or cut-out
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
N
o
Legend
100 mA fast-blow fuse or cut-out
Customisable colours and labels
Fixed or adjustable time delay
Fixed threshold in the generic range
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected