Timers Delay on Release Types B 128, B 121 * Time ranges: 0.15 s to 60 s * Automatic start after drop out of power supply * Knob-adjustable time within range * Repeatability deviation: 1% * Output: 10 A SPDT relay * Plug-in type module * Scantimer housing * LED-indication for supply on * AC or DC power supply Product Description Ordering Key Mono-function, plug-in, delay on release, miniature time relays up to 60 s covering 2 individual time ranges. These economical timers are often Function Output Type Power supply Time range used to switch on an exhaust fan and keep it running for a certain period of time after disconnection of power supply. B 128 220 006 Type Selection Plug Output Time ranges Supply: 24 VAC Supply: 120 VAC Supply: 220 VAC Supply: 24 VDC Circular 8 pins SPDT 0.15 - 6 s 1.5 - 60 s B 128 024 006 B 128 024 060 B 128 120 006 B 128 120 060 B 128 220 006 B 128 220 060 B 128 724 006 B 128 724 060 Circular 11 pins SPDT 0.15 - 6 s 1.5 - 60 s B 121 024 006 B 121 024 060 B 121 120 006 B 121 120 060 B 121 220 006 B 121 220 060 B 121 724 006 B 121 724 060 Time Specifications Time ranges Time range accuracy Repeatability deviation Time variation Within rated power supply and ambient temperature Reset Time and/or relay Output Specifications 0.15 6s 1.5 - 60 s 0 to +20% on max. min. actual time min. set time 1% 0.05%/V 0.2%/C Power supply interruption 500 ms Output Basic electrical insulation Contact ratings (AgCdO) Resistive loads AC 1 DC 1 or Small inductive loads AC 15 DC 13 Mechanical life Electrical life AC 1 SPDT relay 250 VAC (rms) (contact/electronics) (micro gap) 10 A/250VAC (2500 VA) 1 A/250 VDC (250 W) 10 A/25 VDC (250 W) 2.5 A/230 VAC 5 A/24 VDC 30 x 106 operations 2.5 x 105 operations (at max. load) 7200 operations/h Operating frequency Insulation voltages Rated insulation voltage 2.0 kVAC (rms) (cont./elec.) Rated transient protection volt. 4 kV (1.2/50 s) (cont./elec.) (IEC 60664) Specifications are subject to change without notice (25.10.99) 1 B 128, B 121 Supply Specifications General Specifications Power supply AC types Rated operational voltage Through pins 2 & 10 220 or pins 2 & 7 120 Power ON time Indication for Power supply ON Environment Degree of protection Pollution degree Operating temperature Storage temperature Weight Approval Installation cat. III (IEC 60664) 220 VAC 15%, 45 to 65 Hz 120 VAC 15%, 45 to 65 Hz 024 24 VAC 15%, 45 to 65 Hz Dropout tolerance 10 ms Rated insulation voltage None Rated transient protection volt. 4 kV (1.2/50 s) @ 220 VAC 2.5 kV (1.2/50 s) @ 120 VAC 800 V (1.2/50 s) @ 24 VAC (line/neutral) Power supply DC type Installation cat. III (IEC 60664) Rated operational voltage 724 24 VDC + 15/- 20% (pin 2 pos.) Rated insulation voltage None Rated transient protection volt. 800 V (1.2/50 s) 60 mA @ 50 Hz/70 mA @ 60 Hz Consumption AC supply DC supply 1W Mode of Operation The relay operates immediately after power supply is applied. When power supply is interrupted, the time period starts and at the end of the set time the relay releases. If power supply is reapplied before the relay releases, the time is reset and the relay remains on. B 121/B 128 monitor that power supply is applied. If power supply is interrupted, the relay starts e.g. an alarm (battery driven) after the time period has expired. Please note B 128 and B 121 should not be operated by pulses shorter than 500 ms. 200 ms LED, red IP 20 B 2 (IEC 60664) -20 to +50C (-4 to +122F) -50 to +85C (-58 to +185F) 85 g UL, CSA Wiring Diagrams SPDT 8 pin SPDT 11 pin Power supply B 128 Power supply B 121 Time Setting Accessories Knob-adjustable on scale in seconds. Sockets Hold down spring Mounting rack Socket cover Potentiometer lock S 408, S 411 HF SM 13 BB 4 PL 1 For further information refer "Accessories". Operation Diagram Power supply Relay on 2 Specifications are subject to change without notice (25.10.99)