Switching Power Supply Type SPD 30W DIN rail mounting * Universal AC input full range * Installation on DIN rail 7.5 or 15mm * Short circuit protection * Overload protection * Class 2 output * High efficiency * LED indicator for DC power ON * CE, TUV approved and cULus Listed Product Description Ordering Key The Switching power supplies SPD series are specially designed to be used in all automation application where the Model Mounting ( D = Din rail ) Output voltage Output power Input Type Optional features installation is on a DIN rail and compact dimensions and performance are a must. Approvals SP D 12 30 1 B Input type: 1= single phase Optional Features Description code Spring connectors B Output performances Model Output Voltage (VDC) Output Current (A) SPD05 SPD12 SPD24 SPD48 5 12 24 48 6.0 2.5 1.25 0.625 Voltage Trim Range Min. (VDC) Max. (VDC) 5 12 24 48 5.5 14 28 55 DC on LED (VDC Min.) Typical Efficiency 4 9.6 19.2 37 79% 84% 86% 86% Output data Line regulation Load regulation Minimum load Turn on time (full resistive load) Transient recovery time Ripple and noise (bw=20Mhz) 0.5% max 0.5% max 0 1.0s max 300s 50mVpp Ouput Voltage accuracy Temperature coefficient Hold up Time Vi = 115Vac Hold up time Vi = 230Vac Voltage fall time (I0nom) Voltage rise time at full resistive load 2% 0.02%/C 20ms min 30ms min 150ms max 150ms max Input data Rated input voltage Voltage range AC DC 100 - 240 85 - 264 Vac 90 - 375 Vdc Specifications are subject to change without notice Frequency range Inrush current Vi= 115Vac Vi= 230Vac 47- 63 Hz 20A 40A 1 Switching Power Supply Type SPD 30W DIN rail mounting Controls and Protections Overload Input Fuse Output Short Circuit Power ready output (only SPD 24) On threshold Off threshold 110 - 140% T2A/250Vac internal* Fold forward Over voltage protection VDC Min. 6 15 30 60 SPD5 SPD12 SPD24 SPD48 20V 1V 19.2V 1V Max. 6.8 16.5 33 66 General data (@ nominal line, full load, 25C ) Ambient temperature Derating (>60C to +71C) Ambient humidity Storage Protection degree -10C to 71C 2.5%/C 20 ~ 90%RH -25C to +85C IP20 Cooling Switching frequency MTBF Case material Dimensions L x W x D Weight Free air convection 50kHz 565.000h Plastic: PC, UL94-V0 90 x 40.5 x 115 290g Norms and Standards Insulation voltage I / O Insulation resistance UL / cUL 3.000Vac 100Mohm UL508 listed, UL60950-1, UL1310 Class 2 (5V without class 2) Recognised EN60950-1 TUV CE EN61000-6-3 - EN55022 Class B EN61000-3-2 - EN61000-3-3 EN61000-6-2 - EN550241 EN61000-4-2 - EN61000-4-3 EN61000-4-4 - EN61000-4-5 EN61000-4-6 - EN61000-4-8 EN61000-4-11 * fuse not replaceable by user Block diagrams L Fuse Vo + Line Filter Inrush Current Limiter and Rectifier Switching Device Rectifier N Y PWM Controller Opto isolation Current Detection Reference & Error Amp. Output Level Detection Vo - Vout ADJ. DCON (Green LED) RDY (Open Collector) Pin assignement and front controls Pin No. 1 3 4 5 6 7 8 9 2 Designation RDY + + GND L N Vout ADJ. DC ON Description DC OK output for relay (only on SPD24) Positive output terminal Positive output terminal Negative output terminal Negative output terminal Ground terminal to minimise High frequency emissions Phase input ( no polarity with DC input ) Neutral input ( no polarity with DC input ) Trimmer for fine output voltage adjustment DC output ready LED Specifications are subject to change without notice Switching Power Supply Type SPD 30W DIN rail mounting Output Rdy Wiring diagram Derating Diagram Rdy RL> 700ohm Power out (%) SPD 24 - Vout relay Relay connection diagram Rdy 2k2 0.5W SPD 24 5v1 0.3W 5V - Vout 100 90 80 70 60 50 40 30 20 10 0 -10 0 5 10 Temperature (C) 55 60 65 70 75 80 5V signal Mechanical Drawings 40.5 (1.59) 5 1 - + + N.C. 90.0 (3.60) - 115 (4.53) DCON 6 8 Installation Ventilation and cooling Connector size range Normal convection All sides 25mm free space for cooling is recommended Solid: 0.2 - 2mm2 (AWG24-14) (use copper conductors only) Specifications are subject to change without notice 3