Product Data Sheet 8314 HR-197 The engineer's choice Product Data Sheet 8314 HR-197 8314 HR-197 INDEX 1 General ...................................................................................................................................................................... 3 2 Mechanics ................................................................................................................................................................. 3 2.1 2.2 3 Operating Data .......................................................................................................................................................... 4 3.1 3.2 3.3 3.4 3.5 3.6 4 Operating Data - Electrical Interface - Input ...................................................................................................... 4 Electrical Operating Data ................................................................................................................................... 5 Operating Data - Electrical Interface -Output .................................................................................................... 5 Electrical Features ............................................................................................................................................. 5 Aerodynamic ...................................................................................................................................................... 7 Sound Data ........................................................................................................................................................ 8 Environment .............................................................................................................................................................. 8 4.1 4.2 5 General .............................................................................................................................................................. 3 Connections ....................................................................................................................................................... 3 General .............................................................................................................................................................. 8 Climatic requirements*)...................................................................................................................................... 8 Safety ......................................................................................................................................................................... 9 5.1 5.2 Electrical Safety ................................................................................................................................................. 9 Approval Tests ................................................................................................................................................... 9 5/7/2012 page 2 of 9 Product Data Sheet 8314 HR-197 1 General Fan type Rotational direction looking at rotor Airflow direction Bearing system Mounting position 2 Mechanics 2.1 General Width Height Depth Weight Housing material Impeller material 2.2 52,0 mm 70,0 mm 40,0 mm 0,150 kg Plastic Connections Electrical connection Wire 1 Wire 2 Fan clockwise Air outlet over flange Ball bearing any Special design details see drawing Colour red black Operation + UB - GND 5/7/2012 page 3 of 9 Product Data Sheet 8314 HR-197 3 Operating Data 3.1 Operating Data - Electrical Interface - Input Control input None 5/7/2012 page 4 of 9 Product Data Sheet 8314 HR-197 3.2 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23C +/- 3C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: I: corresp. to free air flow (see section 3.5) corresp. to arithm. mean current value Features Voltage range Nominal voltage Power consumption Condition p = 0 p = 0 p = 0 Tolerance Current consumption Tolerance Speed Tolerance Symbol U UN Values 12,0 V P 1,5 W +- 17,5 % I 125 mA +- 17,5 % 284 mA +- 12,5 % 319 mA +- 15,0 % n 2.700 1/min +- 12,5 % 4.900 1/min +- 7,5 % 5.200 1/min +- 10,0 % 0001 p = 0 0001 p = 0 8,6 W +- 15,0 % 0001 Starting current consumption 3.3 27,0 V 25,0 V 7,1 W +- 12,5 % 1.350 mA Operating Data - Electrical Interface -Output Tacho type None Alarm type None Electrical Features Electronic function Reversed polarity protection Max. residual current at Un Locked rotor protection Locked rotor current at Un Clock signal t3/t4 at locked rotor None Rectifying diode IF <= 500 uA Auto restart approx. 1.350 mA Typical: 0,6 s / 10 s 5/7/2012 page 5 of 9 Product Data Sheet 8314 HR-197 5/7/2012 page 6 of 9 Product Data Sheet 8314 HR-197 3.5 Aerodynamic Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23C +/- 3C; In the intake and outlet area should not be any solid obstruction within 0,5 m. a.) Operation condition: 4.900 1/min at free air flow Max. free-air flow (p = 0 / = max.) 65,0 m3/h Max. static pressure (p = max. / =0) 142 Pa Mounted on a traverse. Measured in a aperture plate (Diameter 76,4 mm), wheel in the middle. 5/7/2012 page 7 of 9 Product Data Sheet 8314 HR-197 3.6 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see section 3.5 a.) Operation condition: 4.900 1/min at free air flow Optimal operating point 62,0 m3/h @ 0 Pa Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 6,0 bel(A) 47,0 dB(A) Mounted on a traverse. Measured in a aperture plate (Diameter 76,4 mm), wheel in the middle. 4 Environment 4.1 General Min. permitted ambient temperature TU min. Max. permitted ambient temperature TU max. Min. permitted storage temperature TL min. Max. permitted storage temperature TL max. 4.2 -20 C 70 C -40 C 80 C Climatic requirements*) Humidity requirements Water exposure Radiation exposure Dust requirements humid heat, cyclic; according to DIN EN 60068-2-30, 6 cycle None None Dust check; according to DIN EN 60068-2-68, 6g/m2d, 1 day None None Salt fog requirements Harmful gas requirements *) Permittet application area: The product is for the use in sheltered rooms with limited controlled temperature. Occasionally condensed water is allowed. Directly exposure to water must be avoid. Saline ambient conditions must be avoid. Pollution degree 2 (according DIN EN 60664-1) It occurs only non-conductive pollution. Occassionally, temporary conductivity caused by condensation occurs. 5/7/2012 page 8 of 9 Product Data Sheet 8314 HR-197 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25C measured with U=500 VDC for 1 min. Air and leakage distances Protection class 5.2 CE UL VDE CSA CCC 500 VAC / 1 Min. 500 VAC / 1 Sec. RI > 10 MOhm 1,0 mm / 1,2 mm III Approval Tests Yes No No No No 5/7/2012 page 9 of 9 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: ebm-papst: 8314HR-197