WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as system
installation information.
• Complete installation, operation and maintenance information is to be referenced for each product.
Failure to comply with these instructions could result in death or serious injury.
Safety light curtain
Compact and cost-effective unit
FF-SG Series
FEATURES
• Active Optoelectronic Protective Device
compliant with the requirements of the
IEC/EN 61496-1 and IEC/EN 61496-2
European norms for Type 4
electrosensitive protective equipment
• Meets applicable parts of North
American standards and regulations
OSHA 1910.212 and 217; ANSI B11.1
series; ANSI RIA 15.06 and CSA
•Self-contained unit. No electrical
connection necessary between emitter
and receiver
•2 safety static outputs with short-circuit
and cross-fault detection
• Resolutions available:
ø18 mm / 0.7 in for finger detection
ø30 mm / 1.2 in for hand detection
• Protection height up to 1758 mm / 69.2 in
• Scanning range up to 6 m / 19.7 ft
• Electrical connection: M12 (8 pin)
connectors
• Compact size: only 42 mm2 x 55 mm2 /
1.65 in2 x 2.16 in2 cross sectional area
• Optional interface control module for
more switching capabilities and
additional features
TYPICAL APPLICATIONS
• Presses and punches
• Woodworking machines
• Electronic assembly
• Textile machines
• Pressing, moulding and thermoforming
machines
The Honeywell FF-SG is a self-contained
light curtain that does not require a sepa-
rate control unit for operation. As soon as an object is detected inside the protection
field, the FF-SG opens its two safety static outputs to generate an emergency stop
condition that is used to remove dangerous machine motion when properly inter-
faced with the machine stopping circuitry. When connected to the
FF-SRL60252 optional interface control module, the FF-SG provides a wide variety of
advanced functions: cross-monitored relays, final switching devices monitoring for
the control of external contactors or relays, choice between automatic restart or start
and restart interlock as well as relay status indicators.
The FF-SG is designed in compliance with IEC/EN 61496-1 and IEC/EN 61496-2
standards and meets the requirements for a Type 4 Active Optoelectronic Protective
Device, the safest level for safety products.
The product received an EC type test certificate from the French INRS notified body,
required in Europe for safety equipment as per the 98/37/EC Machinery Directive. It
meets the applicable parts of North American standards and regulations (OSHA,
ANSI and CSA) for light curtains and control reliability and bears the CCSAus listing
mark, making it a product usable in all parts of the world.
The cross section of 42 mm2 x 55 mm2 / 1.65 in2 x 2.16 in2 makes installation possible
in tight spaces, especially with the help of the included mounting hardware. Indica-
tors provide information on the output status and failure diagnostics. The housing
has a dovetail slot mounting system to adapt brackets anywhere along the housing.
The optional FF-SRL60252 interface control module easily fit inside the machine
control panel with its DIN rail mount housing.
Type 4
per IEC/EN 61496-1/2
Approved as