Polysnap Power Inlet Modules [B/BULGIN IEC Inlet - Standard Filter = EMI filter options for Polysnap modules BZV03, BZV04, BZVO9, BZV10, BZV17, BZV18, BZHO9, BZH10, BZH17, BZH18, BZM27, BZM28 PX0575 style IEC inlet Using PSO1/A style filter Standard Attenuation Filter Byoxx/A xx x x / XX Additional s Polysnap Part No. Filter Type Rating L/C Circuit Components Polysnap Part No. 7 ES From Polysnap Selection A = Standard 0O1=1A ] = Version | 0 = None From Polysnap Selection Fs 03 = 3A 2 = Version 2 1 = Bleed (R) Resistor 06 = 6A 3 = Version 3 2 = Surge (VDR) Protection 10 = 10A 3 = R plus VDR Rating | Version | LI | & | & Part No. Example 1 AMP ] 2 x 2.8mH 1 x 15nF 2 x 2.2nF BZV03/A0120/02 = 2 2 x 10mH 1 x 15nF 2 x 2.2nF a 3 2x 10mH 1x 47nF 2x 2.2nF BZV style Polysnap module with PX0575 IEC 3 AMP 1 2 x0.75mH 1x 15nF 2 x 2.2nF power inlet, filter rated at 1 amp, L/C circuit 2 2x 1.8mH 1x 15nF 2x 2.2nF version 2 (L1 = 2 x 10mH, Cx = 1 x 15nF . 3 2x 1.8mH 1x 47nF 2 x 2.2nF Cy = 2 x 2.2nF), without bleed resistor or surge 6 AMP ] 2 x 0.3mH 1 x 15nF 2 x 2.2nF protection device fitted, 6.3mm tabs and single 2 2 x 0.7mH | x 15nF 2 x 2.2nF pole red neon switch. 3 2x 0.7mH 1 x 47nF 2x 2.2nF 10 AMP ] 2x 0.17mH 1 x 15nF 2 x 2.2nF . 2 2 x 0.35mH 1 x 15nF 2 x 2.2nF . 3 2 x 0.17mH 1 x 47nF 2 x 2.2nF Filter Specification Max. Working Voltage: Earth Leakage Current: Temperature Range: Max. Ambient Temp.: (@ Full Load) Test Voltage: Approvals: Attenuation Curves: 250V a.c. 50-400Hz <0.35mA (250V. 50Hz) -25C to +85C 40C (derate linearly to OA @ 85C) 2700V d.c. 2 secs. Lines to Earth 1100V d.c. 2 secs. Live to Neutral &2 EWO See PSOI/A filter, page 111 www.Bulgin.co.uk Tel: +44 (0) 20 8594 5588 75