Technology Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward Guard grilles 553 Lead connections, capacitors 558 Terminal boxes, air filters 562 Speed setting, motor protection switch, third-party accessories 564 549 AC centrifugal, backward 550 AC centrifugal, forward Inlet nozzles Contacts General information Accessories Inlet nozzles o - Material: Galvanised sheet steel Vers. 2 Ok Vers. 1 45 118 r1 Vers. 3 5 6x6 t 0 5 242 R14 2,8 Os Ou 4x90 24 3 4, Om On r3 r2 q 7 5,5 6x6 0 Inlet nozzles for backward curved centrifugal fans Part no. Size(1) 96120-2-4013 120 09566-2-4013 133 Vers. k m (P) 1 146.0 94.4 (P) 1 129.0 87.0 09576-2-4013 175 / 190 (P) 1 170.0 09609-2-4013 220 (P) 2 96358-2-4013 225 (P) 1 96359-2-4013 250 (P/S) 96360-2-4013 97512-2-4013 31050-2-4013 310 o q r1 -- 18.0 0.80 -- 13.0 1.00 125.5 -- 14.0 252.0 155.0 -- 223.0 146.0 -- 1 255.0 164.5 270 / 280 (S) 1 280.0 310 (P) 3 300.0 (A) 1 (2) n r2 r3 s t u 16.0 -- 8.0 -- -- 134.0 4x4.5 126.0 -- 118.0 4x4.5 1.25 10.0 103.0 -- -- 158.0 4x4.5 146.0 21.0 0.80 28.0 1.50 22.0 -- -- -- -- 199.0 25.0 -- -- 210.0 4x4.5 -- 31.0 196.0 1.50 28.0 -- -- 240.0 4x4.5 221.0 182.5 -- 192.0 -- 35.0 1.50 31.0 -- -- 260.0 4x4.5 245.0 53.0 1.00 30.0 60.0 -- -- -- 257.0 300.0 211.0 208.1 48.0 1.25 18.0 55.5 35.0 4x4.5 256.0 280.0 31051-2-4013 310 (A) 1 300.0 211.0 209.2 27.5 1.25 10.0 32.0 20.0 280.0 4x4.5 236.0 51357-2-4013 330 / 355 (P) 1 350.0 224.0 -- 60.0 1.50 54.0 28.0 -- 325.0 4x4.5 284.0 35560-2-4013 355 (A) 1 350.0 240.0 236.4 60.0 1.50 22.5 70.0 44.0 325.0 4x4.5 296.0 325.0 (2) 35561-2-4013 355 (A) 1 350.0 240.0 238.0 30.0 1.50 11.0 35.0 22.0 54476-2-4013 400 (A) 1 370.0 257.0 -- 66.0 1.50 22.0 50.0 90.0 345.0 54478-2-4013 450 (A) 1 413.0 287.0 -- 71.0 1.50 25.0 55.0 63045-2-4013 450 (A) 1 450.0 289.0 284.5 75.0 1.50 28.0 87.0 49.0 425.0 6x9 360.0 54480-2-4013 500 (A) 1 520.0 323.0 -- 79.0 1.50 28.0 65.0 115.0 430.0 6x9 408.0 63072-2-4013 500 (A) 1 470.0 342.0 337.0 75.0 2.00 28.0 87.0 55.0 445.0 6x9 412.0 63071-2-4013 560 (A) 1 515.0 385.0 380.0 82.0 2.00 30.0 95.0 60.0 490.0 6x9 461.0 63070-2-4013 630 (A) 1 634.0 433.0 427.0 98.5 2.00 37.0 14.0 72.0 600.0 6x10.5 525.0 subject to alterations 550 (1) size with key for impeller material: (P) = plastic, (S) = sheet steel, (A) = aluminium (2) short inlet nozzle 100.0 390.0 4x4.5 267.0 4x4.5 322.0 6x9 362.0 k-value For additional information, refer to p. 550 -- 96400-2-4013 250 68 96359-2-4013 -- 96410-2-4013 280 80 96360-2-4013 31100-2-4013 31080-2-4013 310 120 31050-2-4013 31110-2-4013 31090-2-4013 310 103 31051-2-4013 35600-2-4013 35580-2-4013 355 155 35560-2-4013 35610-2-4013 35590-2-4013 355 138 35561-2-4013 54515-2-4013 54500-2-4013 400 183 54476-2-4013 54514-2-4013 54510-2-4013 450 217 54478-2-4013 64015-2-4013 64005-2-4013 450 214 63045-2-4013 54518-2-4013 54516-2-4013 500 265 54480-2-4013 64025-2-4013 64002-2-4013 500 283 63072-2-4013 64030-2-4013 64001-2-4013 560 350 63071-2-4013 64040-2-4013 64000-2-4013 630 480 63070-2-4013 General information AC centrifugal, backward EC centrifugal, backward for clean rooms Size EC centrifugal, forward Part no. with 4 nozzles (Piezometer ring) EC-SYSTEMS Part no. with 1 nozzle EC centrifugal, backward Inlet nozzles with measuring device to determine air flow for backward curved centrifugal fans Technology Accessories subject to alterations 551 Contacts D 0,5xD Air flow measurement: The differential pressure approach compares the static pressure before the inlet nozzle with the static pressure inside the inlet nozzle. Air flow can be calculated on the basis of the differential pressure (difference in pressure of the static pressures) in keeping with the following equation: V in [m3/h] and pW in [Pa] V = k . pW If constant air flow control is used, then the nozzle pressure has to be kept constant: pW = V2 : k2 k takes into account the specific nozzle characteristics. 1 or 4 pressure measuring points are spaced along the circumference of the inlet nozzle. Connection on the customer side is accomplished via a premounted T tube connector. This tube connector is suited for pneumatic hoses with an internal diameter of 4 mm. AC centrifugal, forward Inlet nozzles with pressure-measuring point for air flow measurement Inlet nozzles - Material: Galvanised sheet steel Vers. 1 Vers. 2 106 Vers. 3 45 95 0 f 6x6 19 4 4x90 (2 87 Ou Ob Oa c c 5 4, r 192 ) e d 6x6 e 5,5 0 Inlet nozzles for forward curved centrifugal fans Part no. Size Vers. 09560-2-4013 076 / 085 (1) 1 92.0 63.4 09563-2-4013 097 (1) 1 116.0 80.0 09566-2-4013 108 1 129.0 87.0 118.0 09569-2-4013 120 1 142.0 100.0 09572-2-4013 133 1 150.0 112.0 09576-2-4013 140 / 146 1 170.0 (2) a b c d e f r u 84.0 6.0 3x4.2 0.80 6.8 -- 108.0 10.0 3x4.5 0.80 10.0 -- 13.0 4x4.5 1.00 8.0 -- 132.0 9.0 4x4.5 1.00 8.0 -- 142.0 12.0 4x4.5 1.00 10.0 -- 125.5 158.0 14.0 4x4.5 1.25 10.0 -- 09588-2-4013 160 1 185.0 130.0 175.0 17.0 4x4.5 0.75 12.0 -- 09597-2-4013 180 3 210.0 149.0 -- 28.0 -- 1.25 25.0 -- 09605-2-4013 200 / 225 2 230.0 175.0 213.0 24.0 6x5.5 1.25 20.0 203.0 25010-2-4013 250 (3) 1 300.0 193.0 285.0 51.5 6x7 1.50 27.3 -- 28010-2-4013 280 (3) 1 336.0 228.0 315.0 58.5 6x7 1.50 36.5 296.0 31010-2-4013 310 (3) 1 374.0 257.0 350.0 62.5 6x9 1.50 39.5 327.0 35510-2-4013 355 (3) 1 413.0 289.0 390.0 71.5 6x9 1.50 43.5 372.0 40010-2-4013 400 (3) 1 456.0 325.0 430.0 79.5 6x9 1.50 45.5 414.0 45010-2-4013 450 (3) 1 530.0 365.0 510.0 91.5 6x9 1.50 49.5 459.0 subject to alterations 552 (1) 3 drilled holes staggered by 120 (2) only for 09588-2-1013 (3) 6 drilled holes staggered by 60 General information Guard grille Vers. 2 4x 90 AC centrifugal, backward - Material: Steel wire, plastic coated, silver-metallic gloss a Od 20 3x1 Od AC centrifugal, forward a e e b b Size Vers. a b d e 78130-2-4039 310 1 280.0 4.5 230.0 2.8 78132-2-4039 400 1 345.0 4.5 310.0 2.8 78136-2-4039 450 2 425.0 8.5 350.0 3.8 78139-2-4039 500 2 445.0 8.5 410.0 3.8 78137-2-4039 560 2 490.0 8.5 430.0 3.8 78138-2-4039 630 2 600.0 8.5 490.0 3.8 EC centrifugal, backward for clean rooms Part no. EC centrifugal, backward Guard grille for backward curved centrifugal fans (according to EN 294) Technology Accessories EC-SYSTEMS EC centrifugal, forward subject to alterations 553 Contacts Vers. 1 Guard grille - Material: Welded grille made of galvanised steel, frame made of tinned sheet iron 0.4 mm thick a 11 4,5 c O100 b (4) Size 160 Guard grilles for centrifugal blowers with single inlet Part no. Size 09489-2-4039 076 / 085 (3) 90.0 74.0 84.0 09490-2-4039 108 126.0 110.0 118.0 09494-2-4039 120 140.0 124.0 132.0 09492-2-4039 140 / 146 168.0 152.0 158.0 09503-2-4039 160 (4) 183.0 170.0 175.0 09493-2-4039 180 (5) 205.0 189.0 194.0 subject to alterations a b (3) 3 drilled holes staggered by 120 c (5) not suitable for G2E180-EH03-01 - Material: Steel wire a c max. e 2 d b Guard grilles for centrifugal blowers with single inlet Part no. Size a b c d e Coating 09603-2-4039 98214-2-4039 076 / 085 101.0 6.0 79.0 4.3 8.0 plastic coated, silver-metallic gloss 108 120.0 3.5 88.0 4.3 8.0 plastic coated, silver-metallic gloss 25028-2-4039 140 / 146 162.0 8.5 139.0 4.3 8.0 galvanised, chromatised in blue 17729-2-4039 160 175.0 3.5 139.0 4.6 7.0 galvanised, chromatised in blue 09526-2-4039 180 (6) 194.0 39.5 164.0 4.3 8.0 phosphated, plastic coated in RAL no. 9005 subject to alterations 554 (6) only suitable for G2E180-EH03-01 General information Guard grille AC centrifugal, forward 3x1 20 max. 8 a AC centrifugal, backward - Material: Steel wire b 2 4,3 c a b c 83319-2-4039 097 (1) 96.0 3.5 71.0 phosphated, plastic coated in RAL no. 9005 09485-2-4039 097 (2) 114.0 3.5 88.0 phosphated, plastic coated in RAL no. 9005 09500-2-4039 133 / 146 145.0 4.0 122.0 phosphated, plastic coated in RAL no. 9005 31003-2-4039 180 192.0 9.5 174.0 phosphated, plastic coated in RAL no. 9005 95644-2-4039 200 250.0 5.0 206.0 plastic coated, silver-metallic gloss (1) for D2E097-CH (2) for D2E097-B* - Material: Phosphated steel wire, plastic coated, silver-metallic gloss b EC-SYSTEMS 3x1 2 0 max. 8 a subject to alterations Coating EC centrifugal, backward for clean rooms Size EC centrifugal, forward Part no. EC centrifugal, backward Guard grilles for centrifugal blowers with dual inlet d e c 35000-2-4039 160 62226-2-4039 180 62227-2-4039 a b c d e 182.0 12.0 144.0 2.4 4.5 192.0 9.0 173.0 3.0 5.2 200 213.0 9.0 190.0 3.0 5.2 62228-2-4039 225 / 240 242.0 9.0 222.0 3.0 5.2 25825-2-4039 250 275.0 9.0 255.0 3.0 5.2 Technology Size subject to alterations 555 Contacts Part no. Accessories Guard grilles for centrifugal blowers with dual inlet (versions with EW motor) Guard grille 133 - Material: PA plastic 6.6 GV25 V0, black - Special feature: Triangular, raised contour - Suitable for: D2E140-HR; D2E146-KA; D2E146-KB; D2E146-HR; D2E146-HS; D2E146-HT; D4E146-LV 13 31 Guard grilles for blowers with dual inlet with plastic housing (cable exit side of blower) Part no. 34265-2-2929 subject to alterations 133 - Material: PA plastic 6.6 GV25 V0, black - Special feature: Outer two rings are closed - Suitable for: D2E140-HR; D2E146-KA; D2E146-KB; D2E146-HR; D2E146-HS; D2E146-HT; D4E146-LV; K4E146-AB 13 31 Guard grilles for blowers with dual inlet with plastic housing (side of blower opposite cable exit) Part no. 38182-2-2929 subject to alterations 556 General information Guard grille a AC centrifugal, backward - Material: Phosphated steel wire, plastic coated in RAL no. 9005, black 0 6x6 c AC centrifugal, forward b max. 8 a b c 09513-2-4039 200 250.0 227.0 6.0 09518-2-4039 250 295.0 265.0 7.0 09532-2-4039 300 380.0 323.0 9.0 EC centrifugal, backward for clean rooms Size Technology Accessories EC-SYSTEMS EC centrifugal, forward subject to alterations 557 Contacts Part no. EC centrifugal, backward Guard grilles (e.g. for axial fans) Connection leads AMP Universal Mate-N-Lok, suitable for: Connector shell AMP 926 682-3 Plug pin AMP 926 886-1 Jacketed cable, internal leads H03VV-F6G0.5 black Brass lead tips 6 85 - Suitable for: D2E140-HR; D2E146-KA; D2E146-KB; D2E146-HR; D2E146-HS; D2E146-HT; D2E160-FI; D2E160-FK - Plug assignment: 1 = Step 1 (white) 2 = Step 2 (red) 3 = Step 3 (grey) 4 = Step 4 (black) 5= N (blue) 6 = PE (green/yellow) a Lead connections for centrifugal blowers Part no. a 21956-4-1040 300.0 21957-4-1040 450.0 21958-4-1040 650.0 21959-4-1040 1000.0 subject to alterations AMP Universal Mate-N-Lok suitable for: Connector shell AMP 927 231-3 Plug pin AMP 926 886-1 Jacketed cable, internal leads H03VV-F6G0.5 black Brass lead tips 6 85 a Lead connections for centrifugal blowers Part no. a 21810-4-1012 450.0 21811-4-1012 1050.0 21812-4-1012 1300.0 21813-4-1012 1600.0 21814-4-1012 2300.0 subject to alterations 558 - Suitable for: D4E146-LV; K4E146-AB - Plug assignment: 1 = Step 1 (white) 2 = Step 2 (red) 3 = Step 3 (grey) 4 = Step 4 (orange) 5 = Step 5 (black) 8 = N (blue) 9 = PE (green/ yellow) General information Connection leads AMP Mate-N-Lok female connector AC centrifugal, backward - Plug assignment: 1 = N (black 2) 2 = L (black 1) 3 = PE (green / yellow) AC centrifugal, forward Core-end sleeves 8 85 800 EC centrifugal, backward Line lead for EC centrifugal fans (clean room technology) Part no. 22243-4-1029 Core-end sleeves - Plug assignment: 1 = RSB (white) 2 = RSA (yellow) 3 = +15 V (red) 4 = 0V (blue) EC centrifugal, forward Molex Mini-Fit female connector EC centrifugal, backward for clean rooms subject to alterations 8 85 EC-SYSTEMS 800 Control line for EC centrifugal fans (clean room technology) Part no. 22242-4-1029 559 Contacts Technology Accessories subject to alterations Capacitors b c 10 7 1 Oa M8 10 MKP motor capacitors (without fuse) Part no. Capacity a b (max.) c 02100-4-7320 1.0 F 25-28 58.0 235.0 99282-4-7320 1.5 F 25-28 58.0 235.0 99283-4-7320 2.0 F 25-28 58.0 235.0 02103-4-7320 2.5 F 25-28 70.0 235.0 68462-4-7320 3.0 F 25-28 70.0 235.0 99284-4-7320 4.0 F 28-32 58.0 235.0 02101-4-7320 5.0 F 30-36 70.0 235.0 99285-4-7320 6.0 F 30-36 70.0 235.0 66788-4-7320 7.0 F 30-36 72.0 100.0 99286-4-7320 8.0 F 35-40 72.0 235.0 99287-4-7320 10.0 F 35-40 72.0 200.0 66786-4-7320 12.0 F 40.0 72.0 100.0 30457-4-7320 14.0 F 40-45 92.0 150.0 50090-4-7320 16.0 F 35-40 95.0 100.0 90034-4-7320 20.0 F 40.0 95.0 235.0 90025-4-7320 25.0 F 40.0 120.0 235.0 subject to alterations 560 - Material: Housing made of Thermoplast - Connection lead: Multi-lead PVC cable 0.5 mm2 with brass lead tips - Approval: VDE according to DIN EN 60252 (VDE 0560/8) - Calculated life time: 400 V; -25 to +85C; 30,000 hrs; class A 450 V; -25 to +85C; 10,000 hrs; class B General information - Material: Plastic cap, aluminium cup - Designation: FPU or P2 according to IEC 252 (non-flammable, non-explosive, circuit-breaking) - Approval: VDE according to DIN EN 60252 (VDE 0560/8) - Calculated life time: 420 V; -25 to +85C; 30,000 hrs; class A 470 V; -25 to +85C; 10,000 hrs; class B 500 V; -25 to +85C; 3,000 hrs; class C Oa M8 O a + 3,5 b 7 1 35 +5 235 +10 -5 a b (max.) c (max.) 02151-4-7320 1.0 F 25-30 77.0 92.0 02155-4-7320 1.5 F 25.0 77.0 92.0 02156-4-7320 2.0 F 25.0 77.0 92.0 02159-4-7320 2.5 F 30.0 71.0 92.0 02160-4-7320 3.0 F 30.0 71.0 92.0 02161-4-7320 4.0 F 25-30 104.0 135.0 02162-4-7320 5.0 F 25-30 104.0 113.0 02163-4-7320 6.0 F 30.0 101.0 110.0 02164-4-7320 7.0 F 30-35 101.0 110.0 02165-4-7320 8.0 F 30-35 102.0 111.0 02166-4-7320 10.0 F 35.0 96.0 110.0 02167-4-7320 12.0 F 35.0 96.0 110.0 90026-4-7320 14.0 F 40.0 130.0 139.0 02168-4-7320 16.0 F 40.0 96.0 130.0 02169-4-7320 20.0 F 40.0 116.0 130.0 02170-4-7320 25.0 F 40-45 116.0 130.0 EC centrifugal, backward for clean rooms Capacity EC centrifugal, forward Part no. EC centrifugal, backward MKP motor capacitors FPU or P2 (with fuse) AC centrifugal, backward c 10 AC centrifugal, forward Capacitors EC-SYSTEMS Accessories Technology - Pull-off protector: The housing expands by max. 9 mm. The protector responds to overload by the generated excess pressure snapping off the internal lead in a predetermined breaking point. - Mounting: c is the overall dimension of the capacitor which has to be taken into account when mounting the part. The capacitor design, however, depends on the manufacturer. The expansion (9 mm) is either added to dimension b, or it is already integrated in the capacitor. 561 Contacts max. 9 mm subject to alterations Terminal box = 91,5 b 58 12 29 94 Oa c 56 = 3 18 27,5 Terminal box Part no. AC motor a b c 64442-1-7612 64444-1-7612 068 (4 poles) 22.0 5.0 4.3 068 (7 poles) 22.0 5.0 4.3 64443-1-7612 074 (4 poles) 12x14.5 10.5 5.5 64445-1-7612 074 (7 poles) 12x14.5 10.5 5.5 subject to alterations 562 - Material: ABS - Description: Two-piece terminal box for AC motors of size 068 or 074, terminal strip with 4- or 7-pole. Suitable for installation of capacitor with 10 F max. - Type of protection: IP 54 General information Air filter c b AC centrifugal, backward - Material: Steel wire / sheet steel, plastic coated in RAL no. 9005, black - Filter: Viledon filter type R: PSB / 29 OS (according to DIN 24185) Separation capacity: < 86 % Efficiency: < 20 % Dust binding capacity: 650 g/m2 e AC centrifugal, forward d a 95777-1-5171 108 / 120 95778-1-5171 140 / 146 / 160 95347-1-5171 180 a b c d 142.0 66.0 83.0 118-132 145.0 95779-1-5171 185.0 74.0 91.0 158-175 185.0 95780-1-5171 210.0 74.0 91.0 194.0 e 185.0 Spare filter 95780-1-5171 EC centrifugal, backward for clean rooms Size Technology Accessories EC-SYSTEMS EC centrifugal, forward subject to alterations 563 Contacts Part no. EC centrifugal, backward Air filters for centrifugal blowers (with die-cast aluminium housing) Speed setting, 3-phase (with 5 steps) for wall assembly Current draw Mass Type Frequency Nominal data Nominal voltage - Technical features: Input for TOP - Voltage steps: 3~ 400 / 280 / 230 / 180 / 140 VAC - Type of protection: IP 20 (with vertical installation) VAC Hz A kg TCD 020-AA01 -05 3~ 400 50/60 2.0 9.5 TCD 040-AA01 -05 3~ 400 50/60 4.0 13.9 TCD 070-AA01 -05 3~ 400 50/60 7.0 19.7 subject to alterations 166 189 4xO5,5 185 266 189 224 309 304 564 General information Speed setting, single-phase (with 5 steps) for wall assembly Hz A kg TCE 021-AA01 -05 1~ 230 50/60 2.1 3.6 TCE 040-AA01 -05 1~ 230 50/60 4.0 4.8 TCE 075-AA01 -05 1~ 230 50/60 7.5 6.5 EC centrifugal, backward Mass VAC EC centrifugal, backward for clean rooms Current draw Type Frequency Nominal data Nominal voltage AC centrifugal, forward AC centrifugal, backward - Technical features: Input for TOP - Voltage steps: 1~ 230 / 160 / 145 / 130 / 105 VAC - Type of protection: IP 40 subject to alterations EC-SYSTEMS Accessories 147 167 86 4xO7 EC centrifugal, forward 144 200 565 Contacts Technology 154 204 Motor protection switch, 3-phase for assembly inside a cabinet Current draw Mass Type Frequency Nominal data Nominal voltage - Technical features: Input for TOP VAC Hz A kg Auxiliary contactor TPD 250-AB01 -01 3~ 400 50/60 25.0 0.3 without auxiliary contactor TPD 250-AB01 -02 3~ 400 50/60 25.0 0.3 with break contact TPD 250-AB01 -03 3~ 400 50/60 25.0 0.3 with make contact subject to alterations 68 - Electr. connection: 7 566 54,5 66,5 General information Motor protection switch, single-phase for assembly inside a cabinet Current draw Mass VAC Hz A kg Auxiliary contactor TPE 100-AB01 -01 3~ 230 50/60 10.0 0.3 without auxiliary contactor TPE 100-AB01 -02 3~ 230 50/60 10.0 0.3 with break contact TPE 100-AB01 -03 3~ 230 50/60 10.0 0.3 with make contact EC centrifugal, backward for clean rooms Frequency Type Nominal voltage Nominal data EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward - Technical features: Input for TOP subject to alterations 52,5 EC-SYSTEMS 45 Technology Accessories 70 78 567 Contacts 103 46 EC centrifugal, forward - Electr. connection: Motor-protection switch, single phase and three-phase for wall assembly Current draw Mass Type Frequency Nominal data Nominal voltage - Technical features: Input for TOP - Type of protection: IP 55 VAC Hz A kg Auxiliary contactor TPD 250-AA01 -01 3~ 400 50/60 25.0 0.6 without auxiliary contactor TPD 250-AA01 -02 3~ 400 50/60 25.0 0.6 with break contact TPD 250-AA01 -03 3~ 400 50/60 25.0 0.6 with make contact TPE 100-AA01 -01 1~ 230 50/60 10.0 0.6 without auxiliary contactor TPE 100-AA01 -02 1~ 230 50/60 10.0 0.6 with break contact TPE 100-AA01 -03 1~ 230 50/60 10.0 0.6 with make contact subject to alterations 92 80 141 79 38 568 - Electr. connection, three-phase: - Electr. connection, single-phase: 20 General information Star-delta switch / repair switch Third-party accessories from Moller Electric GmbH AC centrifugal, forward AC centrifugal, backward More information: www.moeller.net for wall installation Designation Installation T0-4-8410/I1 Wall installation T0-4-8410/E Cabinet installation EC centrifugal, backward Star-delta switch (available from Moller Electric GmbH) EC centrifugal, backward for clean rooms subject to alterations EC centrifugal, forward More information: www.moeller.net EC-SYSTEMS for wall installation Repair switch, lockable (available from Moller Electric GmbH) Designation Installation T0-2-8900/I1/SVB-SW Wall installation T0-2-8900/EA/SVB-SW Cabinet installation 569 Contacts Technology Accessories subject to alterations 570