549
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
Accessories
Speed setting, motor protection switch, third-party accessories 564
Terminal boxes, air filters 562
Lead connections, capacitors 558
Guard grilles 553
Inlet nozzles 550
550
Inlet nozzles
4x90˚
Øk
q
o
Øs
t
45˚
118
245
242
6x60˚
5,5
4,3
6x60˚
5
R142,8
7
r
1
r
2
r
3
Øn
ØmØu
Material: Galvanised sheet steel
Inlet nozzles for backward curved centrifugal fans
Part no. Size(1)
54480-2-4013 500 (A)
kmnoqr
1r2r3stu
520.0 323.0 79.0 1.50 28.0 65.0 115.0 430.0 6x9 408.0
63045-2-4013 450 (A) 450.0 289.0 284.5 75.0 1.50 28.0 87.0 49.0 425.0 6x9 360.0
54478-2-4013 450 (A) 413.0 287.0 71.0 1.50 25.0 55.0 100.0 390.0 6x9 362.0
54476-2-4013 400 (A) 370.0 257.0 66.0 1.50 22.0 50.0 90.0 345.0 4x4.5 322.0
35561-2-4013 355 (2) (A) 350.0 240.0 238.0 30.0 1.50 11.0 35.0 22.0 325.0 4x4.5 267.0
35560-2-4013 355 (A) 350.0 240.0 236.4 60.0 1.50 22.5 70.0 44.0 325.0 4x4.5 296.0
51357-2-4013 330 / 355 (P) 350.0 224.0 60.0 1.50 54.0 28.0 325.0 4x4.5 284.0
31051-2-4013 310 (2) (A) 300.0 211.0 209.2 27.5 1.25 10.0 32.0 20.0 280.0 4x4.5 236.0
31050-2-4013 310 (A) 300.0 211.0 208.1 48.0 1.25 18.0 55.5 35.0 280.0 4x4.5 256.0
97512-2-4013 310 (P) 300.0 192.0 53.0 1.00 30.0 60.0 257.0
96360-2-4013 270 / 280 (S) 280.0 182.5 35.0 1.50 31.0 260.0 4x4.5 245.0
96359-2-4013 250 (P/S) 255.0 164.5 31.0 1.50 28.0 240.0 4x4.5 221.0
96358-2-4013 225 (P) 223.0 146.0 28.0 1.50 25.0 210.0 4x4.5 196.0
09609-2-4013 220 (P) 252.0 155.0 21.0 0.80 22.0 199.0
09576-2-4013 175 / 190 (P) 170.0 125.5 14.0 1.25 10.0 158.0 4x4.5 146.0
09566-2-4013 133 (P) 129.0 87.0 13.0 1.00 8.0 118.0 4x4.5 103.0
96120-2-4013 120 (P)
Vers.
1
1
1
2
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
146.0 94.4 18.0 0.80 16.0 134.0 4x4.5 126.0
470.0 342.0 337.0 75.0 2.00 28.0 87.0 55.0 445.0 6x9 412.0
515.0 385.0 380.0 82.0 2.00 30.0 95.0 60.0 490.0 6x9 461.0
634.0 433.0 427.0 98.5 2.00 37.0 14.0 72.0 600.0 6x10.5 525.0
63072-2-4013 500 (A)
63071-2-4013 560 (A)
63070-2-4013 630 (A)
(1) size with key for impeller material: (P) = plastic, (S) = sheet steel, (A) = aluminium (2) short inlet nozzlesubject to alterations
Vers. 2Vers. 1 Vers. 3
551
Inlet nozzles with pressure-measuring point for air flow measurement
0,5
x
D
D
Air flow measurement:
The differential pressure approach compares the static pressure before the
inlet nozzle with the static pressure inside the inlet nozzle.
Air flow can be calculated on the basis of the differential pressure (difference
in pressure of the static pressures) in keeping with the following equation:
V = k .
pWV in [m3/h] and pWin [Pa]
If constant air flow control is used, then the nozzle pressure has to be kept
constant: pW= V2:k
2
k takes into account the specific nozzle characteristics.
1 or 4 pressure measuring points are spaced along the circumference of
the inlet nozzle. Connection on the customer side is accomplished via a
premounted T tube connector. This tube connector is suited for pneumatic
hoses with an internal diameter of 4 mm.
Inlet nozzles with measuring device to determine air flow for backward curved centrifugal fans
Part no. with 1 nozzle Size
64015-2-4013 450
k-value
214
For additional information, refer to p. 550
63045-2-4013
Part no. with 4 nozzles (Piezometer ring)
64005-2-4013
54514-2-4013 450 217 54478-2-401354510-2-4013
54515-2-4013 400 183 54476-2-401354500-2-4013
35610-2-4013 355 138 35561-2-401335590-2-4013
35600-2-4013 355 155 35560-2-401335580-2-4013
31110-2-4013 310 103 31051-2-401331090-2-4013
31100-2-4013 310 120 31050-2-401331080-2-4013
280 80 96360-2-401396410-2-4013
250 68 96359-2-401396400-2-4013
54518-2-4013 500 265 54480-2-401354516-2-4013
64025-2-4013 500 283 63072-2-401364002-2-4013
64030-2-4013 560 350 63071-2-401364001-2-4013
64040-2-4013 630 480 63070-2-401364000-2-4013
subject to alterations
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
552
Inlet nozzles
de
Øb
Øu
f
Øa
c
e
106
6x60˚
c
r
4x90˚
45˚
95
4,5
192
6x60˚
5,5
194
87(2)
Material: Galvanised sheet steel
Inlet nozzles for forward curved centrifugal fans
Part no. Size abcde f ru
45010-2-4013 450 (3)
40010-2-4013 400 (3)
35510-2-4013 355 (3)
31010-2-4013 310 (3)
28010-2-4013 280 (3)
25010-2-4013 250 (3)
09605-2-4013 200 / 225
09597-2-4013 180
09588-2-4013 160
09576-2-4013 140 / 146
09572-2-4013 133
09569-2-4013 120
09566-2-4013 108
09563-2-4013 097 (1)
09560-2-4013 076 / 085 (1)
Vers.
1
1
1
1
1
1
1(2)
3
2
1
1
1
1
1
1
92.0 63.4 84.0 6.0 3x4.2 0.80 6.8
116.0 80.0 108.0 10.0 3x4.5 0.80 10.0
129.0 87.0 118.0 13.0 4x4.5 1.00 8.0
142.0 100.0 132.0 9.0 4x4.5 1.00 8.0
150.0 112.0 142.0 12.0 4x4.5 1.00 10.0
170.0 125.5 158.0 14.0 4x4.5 1.25 10.0
185.0 130.0 175.0 17.0 4x4.5 0.75 12.0
210.0 149.0 28.0 1.25 25.0
230.0 175.0 213.0 24.0 6x5.5 1.25 20.0 203.0
300.0 193.0 285.0 51.5 6x7 1.50 27.3
336.0 228.0 315.0 58.5 6x7 1.50 36.5 296.0
374.0 257.0 350.0 62.5 6x9 1.50 39.5 327.0
413.0 289.0 390.0 71.5 6x9 1.50 43.5 372.0
456.0 325.0 430.0 79.5 6x9 1.50 45.5 414.0
530.0 365.0 510.0 91.5 6x9 1.50 49.5 459.0
(1) 3 drilled holes staggered by 120° (2) only for 09588-2-1013 (3) 6 drilled holes staggered by 60°subject to alterations
Vers. 2Vers. 1 Vers. 3
553
Guard grille
a
e
Ød
be
Ød
b
a
3x120˚
4x90˚
Material: Steel wire, plastic coated,
silver-metallic gloss
Guard grille for backward curved centrifugal fans (according to EN 294)
Part no. Size abde
subject to alterations
Vers.
78130-2-4039 310 280.0 4.5 230.0 2.81
78132-2-4039 400 345.0 4.5 310.0 2.8
1
78136-2-4039 450 425.0 8.5 350.0 3.8
2
78139-2-4039 500 445.0 8.5 410.0 3.8
2
78137-2-4039 560 490.0 8.5 430.0 3.8
2
78138-2-4039 630 600.0 8.5 490.0 3.8
2
Vers. 2Vers. 1
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
554
Guard grille
4,5
a
c
b
Ø100
11
Material: Welded grille made of galvanised
steel, frame made of tinned sheet iron
0.4 mm thick
Guard grilles for centrifugal blowers with single inlet
Part no. Size
09489-2-4039 076 / 085 (3)
abc
90.0 74.0 84.0
09490-2-4039 108 126.0 110.0 118.0
09494-2-4039 120 140.0 124.0 132.0
09492-2-4039 140 / 146 168.0 152.0 158.0
09503-2-4039 160 (4) 183.0 170.0 175.0
09493-2-4039 180 (5) 205.0 189.0 194.0
(3) 3 drilled holes staggered by 120° (5) not suitable for G2E180-EH03-01subject to alterations
db
a
c2
max. e
Material: Steel wire
Guard grilles for centrifugal blowers with single inlet
Part no. Size
09603-2-4039 076 / 085
abcde
101.0 6.0 79.0 4.3 8.0
98214-2-4039 108 120.0 3.5 88.0 4.3 8.0
25028-2-4039 140 / 146 162.0 8.5 139.0 4.3 8.0
17729-2-4039 160 175.0 3.5 139.0 4.6 7.0
09526-2-4039 180 (6) 194.0 39.5 164.0 4.3 8.0
(6) only suitable for G2E180-EH03-01subject to alterations
(4) Size 160
Coating
plastic coated, silver-metallic gloss
plastic coated, silver-metallic gloss
galvanised, chromatised in blue
galvanised, chromatised in blue
phosphated, plastic coated in RAL no. 9005
555
4,3
a
2
b
c
3x120˚
max. 8
Material: Steel wire
Guard grille
Guard grilles for centrifugal blowers with dual inlet
Part no. Size
83319-2-4039 097 (1)
abc
96.0 3.5 71.0
09485-2-4039 097 (2) 114.0 3.5 88.0
09500-2-4039 133 / 146 145.0 4.0 122.0
31003-2-4039 180 192.0 9.5 174.0
95644-2-4039 200 250.0 5.0 206.0
(1) for D2E097-CH (2) for D2E097-B*subject to alterations
Coating
plastic coated, silver-metallic gloss
phosphated, plastic coated in RAL no. 9005
phosphated, plastic coated in RAL no. 9005
phosphated, plastic coated in RAL no. 9005
phosphated, plastic coated in RAL no. 9005
e
a
d
b
c
3x120˚
max. 8
Material: Phosphated steel wire,
plastic coated, silver-metallic gloss
Guard grilles for centrifugal blowers with dual inlet (versions with EW motor)
Part no. Size
35000-2-4039 160
abcde
182.0 12.0 144.0 2.4 4.5
62226-2-4039 180 192.0 9.0 173.0 3.0 5.2
62227-2-4039 200 213.0 9.0 190.0 3.0 5.2
62228-2-4039 225 / 240 242.0 9.0 222.0 3.0 5.2
25825-2-4039 250 275.0 9.0 255.0 3.0 5.2
subject to alterations
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
556
Guard grille
133 13
31
Material: PA plastic 6.6 GV25 V0, black
Special feature: Triangular, raised contour
Suitable for:
D2E140-HR; D2E146-KA; D2E146-KB;
D2E146-HR; D2E146-HS; D2E146-HT;
D4E146-LV
Guard grilles for blowers with dual inlet with plastic housing (cable exit side of blower)
Part no.
34265-2-2929
subject to alterations
133 13
31
Material: PA plastic 6.6 GV25 V0, black
Special feature: Outer two rings are closed
Suitable for:
D2E140-HR; D2E146-KA; D2E146-KB;
D2E146-HR; D2E146-HS; D2E146-HT;
D4E146-LV; K4E146-AB
Guard grilles for blowers with dual inlet with plastic housing (side of blower opposite cable exit)
Part no.
38182-2-2929
subject to alterations
09518-2-4039 250 295.0 265.0 7.0
09532-2-4039 300 380.0 323.0 9.0
557
Guard grille
6x60˚
c
b
a
max. 8
Material: Phosphated steel wire,
plastic coated in RAL no. 9005, black
Guard grilles (e.g. for axial fans)
Part no. Size
09513-2-4039 200
abc
250.0 227.0 6.0
subject to alterations
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
558
Connection leads
6
a
85
Suitable for:
D2E140-HR; D2E146-KA; D2E146-KB;
D2E146-HR; D2E146-HS; D2E146-HT;
D2E160-FI; D2E160-FK
Plug assignment:
1 = Step 1 (white)
2 = Step 2 (red)
3 = Step 3 (grey)
4 = Step 4 (black)
5 = N (blue)
6 = PE (green/yellow)
Lead connections for centrifugal blowers
Part no.
21956-4-1040
a
300.0
21957-4-1040 450.0
21958-4-1040 650.0
21959-4-1040 1000.0
subject to alterations
AMP Universal Mate-N-Lok, suitable for:
Connector shell AMP 926 682-3
Plug pin AMP 926 886-1
Jacketed cable, internal leads
H03VV-F6G0.5 black
Brass lead tips
85
a
6
Suitable for:
D4E146-LV; K4E146-AB
Plug assignment:
1 = Step 1 (white)
2 = Step 2 (red)
3 = Step 3 (grey)
4 = Step 4 (orange)
5 = Step 5 (black)
8 = N (blue)
9 = PE (green/ yellow)
Lead connections for centrifugal blowers
Part no.
21810-4-1012
a
450.0
21811-4-1012 1050.0
21812-4-1012 1300.0
21813-4-1012 1600.0
21814-4-1012 2300.0
subject to alterations
AMP Universal Mate-N-Lok suitable for:
Connector shell AMP 927 231-3
Plug pin AMP 926 886-1
Jacketed cable, internal leads
H03VV-F6G0.5 black
Brass lead tips
559
Connection leads
8
800
85
Plug assignment:
1 = N (black 2)
2 = L (black 1)
3 = PE (green / yellow)
Line lead for EC centrifugal fans (clean room technology)
Part no.
22243-4-1029
subject to alterations
AMP Mate-N-Lok female connector
Core-end sleeves
85
800
8
Plug assignment:
1 = RSB (white)
2 = RSA (yellow)
3 = +15 V (red)
4 = 0 V (blue)
Control line for EC centrifugal fans (clean room technology)
Part no.
22242-4-1029
subject to alterations
Molex Mini-Fit female connector
Core-end sleeves
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
560
Capacitors
c
M8
a
10 b
Ø
7±1
±10
Material: Housing made of Thermoplast
Connection lead: Multi-lead PVC cable
0.5 mm2with brass lead tips
Approval: VDE according to DIN EN 60252
(VDE 0560/8)
Calculated life time:
400 V; -25 to +85°C; 30,000 hrs; class A
450 V; -25 to +85°C; 10,000 hrs; class B
MKP motor capacitors (without fuse)
Part no. Capacity
02100-4-7320 1.0 µF
ab (max.) c
25-28 58.0 235.0
99282-4-7320 1.5 µF 25-28 58.0 235.0
99283-4-7320 2.0 µF 25-28 58.0 235.0
02103-4-7320 2.5 µF 25-28 70.0 235.0
68462-4-7320 3.0 µF 25-28 70.0 235.0
99284-4-7320 4.0 µF 28-32 58.0 235.0
02101-4-7320 5.0 µF 30-36 70.0 235.0
99285-4-7320 6.0 µF 30-36 70.0 235.0
66788-4-7320 7.0 µF 30-36 72.0 100.0
99286-4-7320 8.0 µF 35-40 72.0 235.0
99287-4-7320 10.0 µF 35-40 72.0 200.0
66786-4-7320 12.0 µF 40.0 72.0 100.0
30457-4-7320 14.0 µF 40-45 92.0 150.0
50090-4-7320 16.0 µF 35-40 95.0 100.0
90034-4-7320 20.0 µF 40.0 95.0 235.0
90025-4-7320 25.0 µF 40.0 120.0 235.0
subject to alterations
561
Capacitors
235
735
M8
a
10 b
c
a + 3,5
Ø
+10
-5
Ø
+5
±1
max. 9 mm
Material: Plastic cap, aluminium cup
Designation: FPU or P2 according to
IEC 252 (non-flammable, non-explosive,
circuit-breaking)
Approval: VDE according to DIN EN 60252
(VDE 0560/8)
Calculated life time:
420 V; -25 to +85°C; 30,000 hrs; class A
470 V; -25 to +85°C; 10,000 hrs; class B
500 V; -25 to +85°C; 3,000 hrs; class C
Pull-off protector: The housing expands by
max. 9 mm. The protector responds to over-
load by the generated excess pressure snap-
ping off the internal lead in a predetermined
breaking point.
Mounting: c is the overall dimension of the
capacitor which has to be taken into account
when mounting the part. The capacitor
design, however, depends on the manufac-
turer. The expansion (9 mm) is either added
to dimension b, or it is already integrated in
the capacitor.
MKP motor capacitors FPU or P2 (with fuse)
Part no.
02151-4-7320
ab(max.) c(max.)
subject to alterations
Capacity
1.0 µF 25-30 77.0 92.0
02155-4-7320 25.0 77.0 92.0
02156-4-7320 25.0 77.0 92.0
02159-4-7320 30.0 71.0 92.0
02160-4-7320 30.0 71.0 92.0
02161-4-7320 25-30 104.0 135.0
02162-4-7320 25-30 104.0 113.0
02163-4-7320 30.0 101.0 110.0
02164-4-7320 30-35 101.0 110.0
02165-4-7320 30-35 102.0 111.0
02166-4-7320 35.0 96.0 110.0
02167-4-7320 35.0 96.0 110.0
90026-4-7320 40.0 130.0 139.0
02168-4-7320 40.0 96.0 130.0
02169-4-7320 40.0 116.0 130.0
02170-4-7320 40-45 116.0 130.0
1.5 µF
2.0 µF
2.5 µF
3.0 µF
4.0 µF
5.0 µF
6.0 µF
7.0 µF
8.0 µF
10.0 µF
12.0 µF
14.0 µF
16.0 µF
20.0 µF
25.0 µF
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
562
Terminal box
27,5
18
3
c
58
12
Øa
b56
29
91,5
94
==
Material: ABS
Description: Two-piece terminal box for AC
motors of size 068 or 074, terminal strip
with 4- or 7-pole. Suitable for installation of
capacitor with 10 µF max.
Type of protection: IP 54
Terminal box
Part no. AC motor
64442-1-7612 068 (4 poles)
abc
22.0 5.0 4.3
64444-1-7612 068 (7 poles) 22.0 5.0 4.3
64443-1-7612 074 (4 poles) 12x14.5 10.5 5.5
64445-1-7612 074 (7 poles) 12x14.5 10.5 5.5
subject to alterations
563
Air filter
a
d
b
e
c
Material: Steel wire / sheet steel,
plastic coated in RAL no. 9005, black
Filter: Viledon filter type R: PSB / 29 OS
(according to DIN 24185)
Separation capacity: < 86 %
Efficiency: < 20 %
Dust binding capacity: 650 g/m2
Air filters for centrifugal blowers (with die-cast aluminium housing)
Part no. Size
95777-1-5171 108 / 120
Spare filter
95779-1-5171
abcde
142.0 66.0 83.0 118-132 145.0
95778-1-5171 140 / 146 / 160 95780-1-5171185.0 74.0 91.0 158-175 185.0
95347-1-5171 180 95780-1-5171210.0 74.0 91.0 194.0 185.0
subject to alterations
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
TCD 070-AA01 -05 3~ 400 50/60 7.0 19.7
564
Speed setting, 3-phase (with 5 steps)
for wall assembly
Technical features: Input for TOP
Voltage steps: 3~ 400 / 280 / 230 / 180 / 140 VAC
Type of protection: IP 20 (with vertical installation)
Nominal data
Type
TCD 020-AA01 -05
TCD 040-AA01 -05
subject to alterations
189
309
304
224 166
189 4xØ5,5
185
266
VAC Hz A kg
3~ 400 50/60 2.0 9.5
3~ 400 50/60 4.0 13.9
Nominal voltage
Frequency
Current draw
Mass
565
Speed setting, single-phase (with 5 steps)
for wall assembly
Technical features: Input for TOP
Voltage steps: 1~ 230 / 160 / 145 / 130 / 105 VAC
Type of protection: IP 40
Nominal data
Type
TCE 021-AA01 -05
TCE 040-AA01 -05
subject to alterations
204
154
200
4xØ7
167
147
86
144
VAC Hz A kg
1~ 230 50/60 2.1 3.6
1~ 230 50/60 4.0 4.8
TCE 075-AA01 -05 1~ 230 50/60 7.5 6.5
Nominal voltage
Frequency
Current draw
Mass
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
566
Motor protection switch, 3-phase
for assembly inside a cabinet
Technical features: Input for TOP
Electr. connection:
Nominal data
Type
TPD 250-AB01 -01
TPD 250-AB01 -02
subject to alterations
VAC Hz A kg
3~ 400 50/60 25.0 0.3
Auxiliary contactor
without auxiliary contactor
with break contact3~ 400 50/60 25.0 0.3
TPD 250-AB01 -03 with make contact3~ 400 50/60 25.0 0.3
Nominal voltage
Frequency
Current draw
Mass
68
54,57
66,5
567
Motor protection switch, single-phase
for assembly inside a cabinet
Technical features: Input for TOP
Electr. connection:
Nominal data
Type
TPE 100-AB01 -01
TPE 100-AB01 -02
subject to alterations
VAC Hz A kg
3~ 230 50/60 10.0 0.3
Auxiliary contactor
without auxiliary contactor
with break contact3~ 230 50/60 10.0 0.3
TPE 100-AB01 -03 with make contact3~ 230 50/60 10.0 0.3
Nominal voltage
Frequency
Current draw
Mass
103
52,5
46
45
70
78
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
568
Motor-protection switch, single phase and three-phase
for wall assembly
Technical features: Input for TOP
Type of protection: IP 55
Electr. connection, three-phase:
Electr. connection, single-phase:
Nominal data
Type
TPD 250-AA01 -01
TPD 250-AA01 -02
subject to alterations
VAC Hz A kg
3~ 400 50/60 25.0 0.6
Auxiliary contactor
without auxiliary contactor
with break contact3~ 400 50/60 25.0 0.6
TPD 250-AA01 -03 with make contact3~ 400 50/60 25.0 0.6
TPE 100-AA01 -01 without auxiliary contactor1~ 230 50/60 10.0 0.6
TPE 100-AA01 -02 with break contact1~ 230 50/60 10.0 0.6
TPE 100-AA01 -03 with make contact1~ 230 50/60 10.0 0.6
Nominal voltage
Frequency
Current draw
Mass
80
92
20
569
Star-delta switch / repair switch
Third-party accessories from Möller Electric GmbH
More information: www.moeller.net
Star-delta switch (available from Möller Electric GmbH)
Designation
T0-4-8410/I1
Installation
Wall installation
T0-4-8410/E Cabinet installation
subject to alterations
More information: www.moeller.net
Repair switch, lockable (available from Möller Electric GmbH)
Designation
T0-2-8900/I1/SVB-SW
Installation
Wall installation
T0-2-8900/EA/SVB-SW Cabinet installation
subject to alterations
for wall installation
for wall installation
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
EC centrifugal, back-
ward for clean rooms
EC centrifugal,
forward
EC-SYSTEMSAccessoriesTechnology
Contacts
570