a Plastic bodied compact limit switches | Combi C2 For confined spaces With two mounting options Protection class IP 30 With snap-shut, hinged lid O G7" for} ce OB @ e Compact switches for safety or control applications @ 3 different contact configurations available as slow-action and snap-action @ All normally-closed contacts are positive break G) me @ Two-channel safety control possibie @ Galvanically isolated terminals, type Zb @ Approvals UL, CSA, BG (applied for) @ Rectangular cable inlets (6.5 x 3.5 mm) for 4 x 1-mrr flexible lead @ 4 screw-type connections (M3,5) with self-lifting clamps @ PBT enciosure, glass-fibre reinforced, self-extinguishing UL 94-VO @ Lid, PC UL 94-VO @ 2mm contact opening of slow-action system according to EN 81-1 for lift applications Switching elements Mounting a) 2 holes for M4 screws b) 2 captive M3 nuts for end mounting (depending on type) Switching element Switch function Switch contact Designation Voltage Continuous current Slow-action changeover INC/INO Uz 250 V 10A Snap-action changeover INC/AING SU1Z 250 V 10A Slow-action normally-closed 2NC A2Zz 250 V 10A Snap-action normaily-closed 2NC SA2Z 250 V 10A Slow-action normally-open = 2NO E2 250 V 10A Oran ArtAn nrrmalhsanssnt ONID ocyn none 4A Designation Part no. Switching diagram positive break according to IEC 947-5-1 Chap. 3 Za: changeover contact is not galvanically isolated Zb; changeover contact is galvanically isolated Slow-action cortact/snap-action contact Gasket inside (iw)/outside (w) Contact travel mm Actuating force N . (inch) Tol. + 10% Tol. + 0.25 mm Switch angle degree Actuating torque Nem Tol. + 3.5 tol. + 10% 9 q In Voltage max. Continuous current max. Making current, acc. to IEC 947-5-1 AC 15/DC 13 Switching frequency max. Mech. operational life - number of switching cycles Ambient temperature min./max. Approvals (applied for) Weight Type of storage/time of delivery as agreed Further switching functions SA2 E2 SE2 Cr3.5 4mm 7N hit Dimensions A ANN AReARNnR in mm finanh) 1 SNC2-U1Z C2-SU1IZ C2-A2Z C2-U1Z St C2-SU1Z St C2-A2Z St C2-U1Z K C2-SU1Z K C2-A2Z K 600.8101 .001 600.8351.002 600.8801 .003 600.8104.025 600.8354.026 600.8804.027 600.8107.019 600.8357.020 600.8807.021 ; ; . i WMhet2 4914 dhe 12 I 12 181 me 12 mee 12 13-714 11h 12 | . ' ' 1 I ap q Bh 22 MAE 22 gg eng BLE 22 ALM gg tag MAA 22 211 22 @2b @2b @2Zb @ 2b @2b @zZb @ 2b @ 2b @ 2b e- fe... e/- o/- ~/e e/- @/- -le o/- -/- -f- -/- -f+ -/- -/- -/- /- i 0.5 0.5 0.8 0.5 OR Gr OW oO Amm 4mm 4mm 4mm 250 V AC 250 V AC 250 V AC 250 V AC 250 V AC 250 V AC 250 V AC 250 V AC 250 V AC 10A 10A 10A 10A 10A 10A 10A 10A 10A e e e e e e e 100/min. 100/min. 100/min. 100/min. 100/min. 100/min. 100/min. 100/min. 100/min. 3x 10 3x 10 3 x 10 3x 10 3x 10 3x 10 3x 10 3x 10 3x 10 -30 C/+80 C 3-80 C/+80 C ~30 C/+80 C -30 C/+80 C -30 C/+80 C ~30 C/+80 C = -80 C /+80 C 30 C/+80 C -30 C/+80 C -22F/4176 F 9-22 F/4176 F 9-22 F /4176 F 9-22 F /4176 F = 22 F/4176 F = 22 OF 176 F | 22 F /4 176 F = 22 OF /4 176 F 22 F +176 OF UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA BG BG BG BG BG BG BG BG BG 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg e/- o/- e/- o/- o/- o/- o/- e/- e/-Designation C2-U1Z R C2-SU1Z R C2-A2Z R C2-U1IZO.M.+H C2-SUIZO.M.+4H C2-A270.M.+H Switch part number 600.8116.013 600.8366.014 600.8816.015 600.8101.007 600.8351.008 600.8801.009 Actuator part number - - - 391.0190.259 391.0190.259 391.0190.259 Switching diagram 9 9 9 9 ? positive break according to IEC 947-5-1 Chap. 3 Whe 12 B= 4 Ti He 12 Mpg 12 Br= 4 4 hr 12 Za: changeover contact is not galvanically isolated 23+ 24 21Ap 22 21Ae 22 23-24 21 ~W 22 214 22 2b: changeover contact is galvanically isolated @ 2b @ Zb @ 2b Zb Zo 2b Slow-attion contact/snap-action contact e/- -/e e/- e/- -/@ e/- Gasket inside (iw/outside (w} -/- -/ ; -/- -/- -/- -/- Contact travel mm Actuating force N {inch} Tol. + 10% Tol. + 0.25 mm Orme Omm 0.5 0.5 Switch angle degree Actuating torque Nem 1.34 1.3 1.3 Tol. + 10% , & 38 On Tol, + 3.5 On Off 4mm 10N mm m 4 1 { Voltage max. 250 VAC 250 V AC 250 V AC 250 V AC 250 V AC 250 V AC Continuous current max. 10A 10A 10A 10A TOA 10A Making current, acc. to IEC 947-5-1 AC 15/DC 13 e e e e e e Switching frequency max. 100/min. 100/min. 100/min. 100/min. 100/min. 100/min. Mech. operational life - number of switching cycles 3 x 10 3x 10 3x 10 3 x 10 3x 10 3 x 10 Ambient temperature min/max. -30C/+80C -30C/*80C +30 C/+80 C ~30 C/+80 C ~30 C/+80 C -30 C/+80 C -22 F/+176 F 22 F/+176 F 22 F 4176 F | 22 F 4176 F = 22 F /4176F 29-22 F/4176 OF Approvals UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA {applied for} BG BG BG BG BG BG Weight 0.02 kg 0.02 kg 0.02 kg 0.03 kg 0.03 kg 0.03 kg Type of storage/time of delivery as agreed o/- o/- e/- o/- o/- o/- Further switching functions SA2 E2 H~he12 19214 21 ~~ 22 23 a 24 SE2 bi-t2 Wi-t2 n 4am JN 4mm 11.5N