HALOGEN 5 x 20mm Medium Time-Delay Glass Tube Fuses HF FREE GMC Series Rated Current 63mA - 10A Pb Electrical Characteristics % of Amp Rating Opening Time 100% None 135% 60 minutes maximum 200% 2 minutes maximum Agency Information * * * * * Description * * * * * Medium time-delay, low breaking capacity Available with optional axial leads 5 x 20mm physical size Glass tube, nickel-plated brass endcap construction Designed to UL/CSA 248-14 UL Listed, Guide JDYX, File E19180, 63mA-6.3A UL Recognized Card: (7A-10A) Guide JDYX2, File E19180 CSA Certified, Class 1422-01, File E65063, 63mA-6.3A MITI Approval, 1A-10A KC-Mark: Certificate SU05011-4001 (63mA~250mA); SU05011-4002 (300mA~800mA); SU05011-4003 (1A~3.15A); SU05011-4004 (3.5A~6.3A) Ordering * Specify packaging code prefix, product number and option code suffix * For RoHS compliant version (suffix "-R"), drop mA or A from product code (e.g., GMC-2-R) Specifications Product Number GMC-63mA GMC-80mA GMC-100mA GMC-125mA GMC-150mA GMC-160mA GMC-200mA GMC-250mA GMC-300mA GMC-315mA GMC-400mA GMC-500mA GMC-600mA GMC-630mA GMC-700mA GMC-750mA GMC-800mA GMC-1A GMC-1.25A GMC-1.5A GMC-1.6A GMC-2A GMC-2.5A GMC-3A GMC-3.15A GMC-3.5A GMC-4A GMC-5A GMC-6A GMC-6.3A GMC-7A GMC-8A GMC-10A Voltage Rating Vac 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 125 125 125 125 125 125 125 125 Interrupting Rating (Amps)* 250Vac 125Vac 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 100 10,000 100 10,000 100 10,000 100 10,000 100 10,000 100 10,000 100 10,000 10,000 10,000 10,000 10,000 10,000 200 200 200 Typical DC Cold Resistance ()** 10.350 4.775 3.400 2.555 2.295 1.395 0.965 0.838 0.685 0.615 0.335 0.282 0.246 0.213 0.213 0.180 0.156 0.098 0.076 0.067 0.043 0.035 0.026 0.025 0.022 0.019 0.014 0.013 0.012 0.012 0.009 0.007 Typical Pre-Arc I2t AC 0.0027 0.0050 0.0094 0.014 0.022 0.022 0.032 0.046 0.081 0.081 0.18 0.41 0.60 0.66 0.85 0.85 0.85 1.8 3.4 5.4 5.8 8.9 13 19 23 25 36 58 88 110 150 200 300 * Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC. The interrupting ratings for 7A - 10A were measured at 100% power factor on AC. ** DC Cold Resistance (Measured at <10% of rated current) Typical Pre-Arching I2t (I2t was measured at listed interrupting rating and rated voltage) Maximum Voltage drop (Voltage drop was measured at 20C ambient temperature at rated current) 0711 BU-SB11757 Page 1 of 2 Data Sheet 4395 Maximum Voltage Drop (mV) 1400 1400 1200 1000 800 730 650 490 580 480 510 370 360 360 340 320 290 250 200 190 160 130 130 130 130 130 120 120 120 120 120 110 110 Dimensions - mm Time-Current Curves Drawing Not to Scale 100mA 125mA 150mA 200mA 250mA 315mA 300mA 400mA 500mA 750mA 800mA 1A 1.5A 1.6A 2A 2.5A 3A 3.5A 4A 5A 6A 6.3A 7A 8A 10A 38.10mm (.38) 63mA 80mA 5.54mm (.20) 100 10mm 20mm (2.0) (0.5) AMP RATING 21.10mm (.81) 5.2mm (+0.1/-0.2) 10 0.65mm (REF) * Ratings above 6.3A have a 0.8mm diameter lead * With TR2 packaging code, lead wire length is 19.05mm TIME IN SECONDS 38.10mm (.38) 1 100 10 1 .01 .1 .1 CURRENT IN AMPS Packaging Code Product Number Prefix BKBK1TR2- Description 100 fuses packed into a cardboard carton 1000 fuses packed into a poly bag 1500 Axial lead fuses packed into tape on a reel (19.05mm lead wire length) Product Number Suffix -V -R Description Axial leads - copper tinned wire with nickel plated brass overcaps (place before amp rating; e.g., GMC-V-2) RoHS compliant version (drop "mA" or "A" from product number when ordering) Option Code The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. (c) 2011 Cooper Bussmann www.cooperbussmann.com 0711 BU-SB11757 Page 2 of 2 Data Sheet 4395