Series AM6Q-Z
6 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 051e R12.C 1 of 3 North America only
FEATURES:
RoHS Compliant
Operating Temperature -40ºC to 85ºC
Wide 2:1 input range
Input / Output Isolation of 500VAC
High Efficiency up to 86%
No Tantalum capacitors used inside
Continuous short circuit
Over voltage protection
Models
Single output
Model Input Voltage
(V)
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VAC)
Max
Capacitive
Load(uF)
Efficiency
(%)
AM6Q-0503SZ 4.5-9 3.3 1000 500 1000 73
AM6Q-0505SZ 4.5-9 5 1000 500 1000 76
AM6Q-0512SZ 4.5-9 12 500 500 500 79
AM6Q-0515SZ 4.5-9 15 400 500 400 79
AM6Q-1203SZ 9-18 3.3 1000 500 1000 76
AM6Q-1205SZ 9-18 5 1200 500 1200 81
AM6Q-1212SZ 9-18 12 500 500 500 85
AM6Q-1215SZ 9-18 15 400 500 400 85
AM6Q-2403SZ 18-36 3.3 1200 500 1200 73
AM6Q-2405SZ 18-36 5 1200 500 1200 80
AM6Q-2412SZ 18-36 12 500 500 500 84
AM6Q-2415SZ 18-36 15 400 500 400 86
AM6Q-4803SZ 36-75 3.3 1200 500 1200 74
AM6Q-4805SZ 36-75 5 1200 500 1200 80
AM6Q-4812SZ 36-75 12 500 500 500 84
AM6Q-4815SZ 36-75 15 400 500 400 85
Models
Dual output
Model Input Voltage
(V)
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VAC)
Max
Capacitive
Load(uF)
Efficiency
(%)
AM6Q-0512DZ 4.5-9 ±12 ±250 500 ±250 82
AM6Q-0515DZ 4.5-9 ±15 ±200 500 ±200 82
AM6Q-1212DZ 9-18 ±12 ±250 500 ±250 88
AM6Q-1215DZ 9-18 ±15 ±200 500 ±200 88
AM6Q-2412DZ 18-36 ±12 ±250 500 ±250 88
AM6Q-2415DZ 18-36 ±15 ±200 500 ±200 88
AM6Q-4812DZ 36-75 ±12 ±250 500 ±250 87
AM6Q-4815DZ 36-75 ±15 ±200 500 ±200 88
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters Nominal Typical Maximum Units
Voltage range
5 4.5-9
VDC
12 9-18
24 18-36
48 36-75
Filter π (Pi) Network
Start up time 20 ms
No Load Input Current 45 mA
Input reflected current 20 mA
Click on Series name for product info on aimtec.com
Series AM6Q-Z
6 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 051e R12.C 2 of 3 North America only
Isolation Specifications
Parameters Conditions Typical Maximum Units
Tested I/O voltage 3sec 500 VAC
Resistance 50 MOhm
Capacitance 500 pF
Output Specifications
Parameters Conditions Typical Maximum Units
Voltage accuracy ±1 %
Cross Regulation (Dual Output Models) 25% load on one output –
100% load on the other output ±5 %
Over voltage protection Zener Diode Clamp
5 6.2
V
12 15
15 18
±12 ±15
±15 ±18
Over Current Protection FL 185 %
Short Circuit protection Continuous
Short circuit restart Auto Recovery
Line voltage regulation LL-HL ±0.5 % of Vin
Load voltage regulation Load:0-100% unbalanced ±1 %
Temperature coefficient ±0.02 %/oC
Ripple & Noise 20MHz Bandwidth 75 mV p-p
Minimum Load Current 0 % of Max
General Specifications
Parameters Conditions Typical Maximum Units
Switching frequency 100% load 330 KHz
Operating temperature Derating above 60ºC -40 to +85 oC
Storage temperature -40 to +125 oC
Maximum case temperature 100
oC
Cooling Free Air Convection
Humidity 95 % RH
Case material Nickel Coated Copper
Weight 25 g
Dimensions (L x W x H) 1.75 x 1.10 x 0.28 inches 44.50 x 28.00 x 7.00 mm
MTBF >1.28Mhrs ( MIL-HDBK -217F, Ground Benign, t=+25°C )
Transient recovery deviation ±3 %
Safety Specifications
Parameters
Standards Designed to meet IEC/EN 60950-1
Pin Out Specifications
Pin Single Dual
1 -V Input -V Input
2 +V Input +V Input
3 +V Output +V Output
4 NP Common
5 -V Output -V Output
NP: Not Populated
Series AM6Q-Z
6 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 051e R12.C 3 of 3 North America only
Dimensions
28.00
(1.10)
6.60
(0.26)
4.40
(0.17)
2.70
(0.11)
3.84
(0.15)
10.16
(0.40)
15.24
(0.60)
10.16
(0.40)
7.00
(0.28)
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.