IDT5V996
3.3V PROGRAMMABLE SKEW PLL CLOCK DRIVER TURBOCLOCK II PLUS
NOVEMBER 2004
2004 Integrated Device Technology, Inc. DSC 5855/6c
INDUSTRIAL TEMPERATURE RANGE
The IDT logo is a registered trademark of Integrated Device Technology, Inc.
FEATURES:
3.3V operation
4 pairs of programmable skew outputs
Low skew: 150ps same pair, 350ps all outputs
Selectable positive or negative edge synchronization:
Excellent for DSP applications
Synchronous output enable
Input frequency: 25MHz to 225MHz
Output frequency: 25MHz to 225MHz
2x, 4x, 1/2, and 1/4 outputs (of VCO frequency)
3-level inputs for skew control
PLL bypass for DC testing
External feedback, internal loop filter
12mA balanced drive outputs
Low Jitter: <150ps peak-to-peak
Available in 144-pin BGA package
FUNCTIONAL BLOCK DIAGRAM
IDT5V996
3.3V PROGRAMMABLE
SKEW PLL CLOCK DRIVER
TURBOCLOCKTM II PLUS
PLL
Skew
Select
1F2:0
Skew
Select
4F2:0
Skew
Select
3F2:0
Skew
Select
2F2:0
LOCK
FB
REF
TEST
1Q0
1Q1
2Q0
2Q1
3Q0
3Q1
4Q0
4Q1
333
SE
Enable
Logic
333
3 3 3
333
G
DESCRIPTION:
The IDT5V996 is a high fanout PLL based clock driver intended for high
performance computing and data-communication applications. The IDT5V996
has eight programmable skew outputs organized in four banks of two. Skew
is controlled by 3-level input signals that may be hard wired to appropriate
HIGH-MID-LOW levels. The IDT5V996 provides up to 18 programmable
levels of output skew, prescaling, and other features.
Other features of IDT5V996 are synchronous output enable (G), TEST,
and lock detect indicator (LOCK). When G is held low, all the outputs are
synchronously enabled, however, if G is held high, all outputs except 3Q0
and 3Q1 are in the state designated by SE (HIGH or LOW).
When TEST is held low, the chip operates in normal condition. When held
high, the PLL is shut off and the chip functions as a buffer. The lock detect
indicator asserts high when the phase lock loop has acquired lock. During
acquisition, the indicator is in the low state. Once the PLL has reached the
steady-state condition within a specified frequency range, LOCK is
asserted high.
The PLL is closed externally to provide more flexibility by allowing the
user to control the delay between the input clock and the outputs. The
IDT5V996 has LVTTL outputs with 12mA balanced drive outputs.
The IDT5V996 is characterized for operation from –40°C to +85°C.
2
INDUSTRIAL TEMPERATURE RANGE
IDT5V996
3.3V PROGRAMMABLE SKEW PLL CLOCK DRIVER TURBOCLOCK II PLUS
PIN CONFIGURATION
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
12345678910 11 12
12
G
REF
FB
SE
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
3456789
10 11 12
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
TEST
2Q1 2Q0 1Q1 1Q0
LOCK
2F2
2F0
1F1
4F1
3F0
3F2
2F1
1F2
1F0
4F0
4F2
3F1
3Q1 3Q0 4Q1 4Q0
VDDQ
VDDQ
VDDQ
VDDQ
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
GND
GND
VDD
VDD
GND
GND
GND
GND
GND
GND
GND
GND
GND GND GND GND GND GND
GND
GND GND GND
GND
VDD
VDD
GND
GND
GND
GND
GND
GND
VDD
VDD
GND
GND
GND
GND
GND
GND
VDD
VDD
GND
GND
GND
GND
GND
GND
VDD
VDD
GND
GND
GND
GND
GND
GND
VDD
VDD
GND
GND
GND
GND
GND
GND
VDDQ
VDDQ
VDDQ
VDDQ
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
BGA
TOP VIEW
3
INDUSTRIAL TEMPERATURE RANGE
IDT5V996
3.3V PROGRAMMABLE SKEW PLL CLOCK DRIVER TURBOCLOCK II PLUS
NOTES:
1. Stresses beyond those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions above those indicated in the
operational sections of this specification is not implied. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
2. The input and output negative-voltage ratings may be exceeded if the input and
output clamp-current ratings are observed.
Output skew with respect to the REF input is adjustable to compensate
for PCB trace delays, backplane propagation delays or to accommodate
requirements for special timing relationships between clocked compo-
nents. Skew is selectable as a multiple of a time unit (tU) which ranges
from 278ps to 625ps (see Programmable Skew Range and Resolution
Table). There are 16 skew configurations available for each output pair.
These configurations are chosen by the nF2:0 control pins. In order to
minimize the number of control pins, 3-level inputs (HIGH-MID-LOW)
are used, they are intended for but not restricted to hard-wiring. Undriven
3-level inputs default to the MID level. Where programmable skew is
not a requirement, the control pins can be left open for the zero skew
default setting. The Control Summary Table shows how to select specific
skew taps by using the nF2:0 control pins.
PROGRAMMABLE SKEW
ABSOLUTE MAXIMUM RATINGS(1)
Symbol Description Max Unit
VDDQ, VDD Supply Voltage Range –0.5 to +4.6 V
VI(2) Input Voltage Range –0.5 to 4.6 V
VO(2) Voltage range applied to any –0.5 to V
output in the high or low state VDDQ + 0.5
IIK (VI < 0) Input Clamp Current 50 mA
IO (VO = 0 to VDDQ) Continuous Output Current ±50 mA
VDDQ or GND Continuous Current ±100 mA
TSTG Storage Temperature Range –65 to +150 °C
NOTES:
1. Unused inputs must be held high or low to prevent them from floating.
2. Capacitance applies to all inputs except nF2:0. This value is characterized but not
production tested.
CAPACITANCE(1,2)(TA = +25°C, f = 1MHz, VIN = 0V)
Parameter Description Min Typ. Max. Unit
CIN Input Capacitance 8 pF
VI = VDDQ or GND
PIN DESCRIPTION
Pin Name Type Description
REF IN Reference Clock Input
SE IN Selectable positive or negative edge control. When LOW / HIGH, the outputs are synchronized with the negative/positive edge of the
reference clock. When outputs are synchronously stopped with the G pin, SE determines the level at which outputs stop. When SE is
LOW/HIGH, outputs synchronously stop HIGH/LOW.
FB IN Feedback Input
G IN Output gate for “true” nQ[1:0] outputs. When G is LOW, the “true” nQ[1:0] outputs are enabled. When G is HIGH, the “true” nQ[1:0] outputs
are in the state designated by SE (HIGH or LOW) (except 3Q0 and 3Q1) - 3Q0 and 3Q1 may be used as the feedback signal to maintain
phase lock.
TEST IN TEST = LOW means normal operation. TEST = HIGH means that the PLL is powered down and REF is routed to all the outputs. The
skews selected with the nF[2:0] pins are still in effect. (The TEST pin is a TTL input.)
nF[2:0] IN 3-level inputs for selecting 1 of 18 skew taps or frequency functions
nQ[1:0] OUT Clock Output Pairs
VDDQ PWR Power supply for output buffers
VDD PWR Power supply for phase locked loop and other internal circuitry
GND PWR Ground
LOCK OUT Lock Detect. Asserted (HIGH) when the PLL is locked. The REF input must be oscillating. (For more information on application specific
use of the LOCK pin, please see AN237.)
4
INDUSTRIAL TEMPERATURE RANGE
IDT5V996
3.3V PROGRAMMABLE SKEW PLL CLOCK DRIVER TURBOCLOCK II PLUS
EXTERNAL FEEDBACK
By providing external feedback, the IDT5V996 gives users flexibility
with regard to skew adjustment. The FB signal is compared with the
input REF signal at the phase detector in order to drive the VCO. Phase
differences cause the VCO of the PLL to adjust upwards or downwards
accordingly.
An internal loop filter moderates the response of the VCO to the
phase detector. The loop filter transfer function has been chosen to
provide minimal jitter (or frequency variation) while still providing accu-
rate responses to input frequency changes.
CONTROL SUMMARY TABLE FOR FEEDBACK SIGNALS(1)
nF2nF1nF0Output Skew
L L L Disable(2)
L H L -7tU
L H M -6tU
L H H -5tU
M L L -4tU
M L M -3tU
M L H -2tU
M M L -1tU
M M M Zero Skew
M M H +1tU
M H L +2tU
M H M +3tU
M H H +4tU
H L L +5tU
H L M +6tU
H L H +7tU
H M L Inverted
H M M Divide by 2
H M H Divide by 4
Comments
Timing Unit Calculation (tU) 1/(16 x FNOM)
VCO Frequency Range (FNOM)(1) 100 to 225 MHz
Skew Adjustment Range(2)
Max Adjustment: ±4.375ns ns
±157.5° Phase Degrees
±43.75% % of Cycle Time
Example 1, FNOM = 100MHz tU = 0.625ns
Example 2, FNOM = 167MHz tU = 0.374ns
Example 3, FNOM = 225MHz tU = 0.278ns
PLL PROGRAMMABLE SKEW RANGE AND RESOLUTION TABLE
NOTES:
1. The VCO frequency always appears at nQ1:0 outputs when they are operated in their undivided modes. The frequency appearing at the REF and FB inputs will be FNOM when
the output connected to FB is undivided. The frequency of the REF and FB inputs will be FNOM /2 or FNOM /4 when the part is configured for frequency multiplication by using
a divided output as the FB input. Using the nF[2:0] inputs allows a different method for frequency multiplication (see Control Summary Table for Feedback Signals).
2. Skew adjustment range assumes that a zero skew output is used for feedback. If a skewed Q output is used for feedback, then adjustment range will be greater. For example
if a 4tU skewed output is used for feedback, all other outputs will be skewed –4tU in addition to whatever skew value is programmed for those outputs. ‘Max adjustment’ range
applies to all output pairs where ± 7tU skew adjustment is possible and at the lowest FNOM value.
NOTES:
1. All unused/unnoted combinations are reserved.
2. When G is LOW, all output pairs are individually disabled to the level designated by SE. When SE is LOW/HIGH, output pairs disable HIGH/LOW.
5
INDUSTRIAL TEMPERATURE RANGE
IDT5V996
3.3V PROGRAMMABLE SKEW PLL CLOCK DRIVER TURBOCLOCK II PLUS
RECOMMENDED OPERATING RANGE
Symbol Description Min. Typ. Max. Unit
VDD / VDDQ Power Supply Voltage 3 3.3 3. 6 V
TAAmbient Operating Temperature -40 +25 +85 °C
POWER SUPPLY CHARACTERISTICS
Symbol Parameter Test Conditions(1) Typ.(2) Max. Unit
IDDQ Quiescent Power Supply Current VDDQ = Max., REF = FB = SE = G = LOW, 30 m A
TEST = HIGH, All nF2:0 = HHM(3),
All outputs floating
IDDD Dynamic Power Supply Current per Output VDDQ = Max., CL = 0p F 410 650 μA/MHz
VDDQ = 3.3V, FVCO = 100MHz, CL = 20pF 124
ITOT Total Power Supply Current VDDQ = 3.3V, FVCO = 167MHz, CL = 20pF 197 mA
VDDQ = 3.3V, FVCO = 225MHz, CL = 20pF 253
NOTES:
1. Measurements are for divide-by-1 outputs.
2. For nominal voltage and temperature.
3. This configuration is only specific for IDDQ measurements.
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Symbol Parameter Conditions Min. Max. Unit
VIH Input HIGH Voltage Guaranteed Logic HIGH (REF, FB Inputs Only) 2 V
VIL Input LOW Voltage Guaranteed Logic LOW (REF, FB Inputs Only) 0. 8 V
VIHH Input HIGH Voltage Level (1) 3-Level Inputs Only VDD0.6 V
VIMM Input MID Voltage Level(1) 3-Level Inputs Only VDD/20.3 VDD/2+0.3 V
VILL Input LOW Voltage Level(1) 3-Level Inputs Only 0 .6 V
IIN Input Leakage Current VIN = VCC or GND -5 +5 µA
(REF, FB Inputs Only) VCC = Max.
VIN = VDD HIGH Level +200
I33-Level Input DC Current (nF2:0)VIN = VDD/2 MID Level -50 +50 µA
VIN = GND LOW Level -200
VOH Output HIGH Voltage Level VDD = Min., IOH = 12mA 2.4 V
VOL Output LOW Voltage Level VDD = Min., IOL = 12mA 0.4 V
NOTE:
1 . These inputs are normally wired to VDDQ, GND, or unconnected. Internal termination resistors bias unconnected inputs to VDDQ/2. If these inputs are switched, the function and
timing of the outputs may be glitched, and the PLL may require an additional tLOCK time before all datasheet limits are achieved.
6
INDUSTRIAL TEMPERATURE RANGE
IDT5V996
3.3V PROGRAMMABLE SKEW PLL CLOCK DRIVER TURBOCLOCK II PLUS
NOTES:
1. Measured at VTH = VDDQ/2, output load CL = 20pF.
2. Skew is the time between the earliest and the latest output transition among all outputs for which the same tU delay has been selected when all are loaded with the specified
load.
3. tSKEWPR is the skew between a pair of outputs (xQ0 and xQ1) when all eight outputs are selected for 0tU.
4. There are 3 classes of outputs: Nominal (multiple of tU delay), Inverted, and Divided (Divide-by-2 or Divide-by-4 mode).
5. tDEV is the output-to-output skew between any two devices operating under the same conditions (VDD and VDDQ, ambient temperature, air flow, etc.)
6. tLOCK is the time that is required before synchronization is achieved. This specification is valid only after VDD and VDDQ are stable and within normal operating limits. This
parameter is measured from the application of a new signal or frequency at REF or FB until tPD is within specified limits.
7. tODCV is measured with nF[2:0] = MMM.
SWITCHING CHARACTERISTICS OVER OPERATING RANGE(1)
Symbol Parameter Min. Typ. Max. Unit
FNOM VCO Frequency Range See PLL Programmable Skew Range and Resolution Table
FREF REF Clock Input Frequency 25 2 2 5 MHz
tREF REF Clock Duty Cycle 10 90 %
tUProgrammable Skew Time Unit See Control Summary Table
tSKEWPR Matched-Pair Skew (xQ0, xQ1)(1,2,3) 150
tSK(0) Output Skew (Rise-Rise, Fall-Fall, Same Frequency and Phase)(1,2) 350
tSK(ω)Multiple Frequency Skew(1,2) 550
tSK(INV) Inverting Skew Between Nominal and Inverted(1,2,4) 500
tSKEW1 Output Skew (Rise-Fall, Inverted-Divided)(1,2) 500 ps
tSKEW4 Output Skew (Rise-Fall, Divided-Divided)(1,2,4) 500
tDEV Device-to-Device Skew(2,5) 250
tφREF Input to FB Static Phase Offset (VTH = VDDQ/2) -250 +250
tODCV Output Duty Cycle Variation from 50%(1,7) -0.75 +0.75 ns
tROutput Rise Time (0.8V to 2V)(1) 2.2 ns
tFOutput Fall Time (2V to 0.8V)(1) 2.2 ns
tLOCK PLL Lock Time(6) 0.5 ms
tJCycle-to-Cycle Output Jitter, Peak-to-Peak(1) 150 ps
7
INDUSTRIAL TEMPERATURE RANGE
IDT5V996
3.3V PROGRAMMABLE SKEW PLL CLOCK DRIVER TURBOCLOCK II PLUS
CL = 20pF
150Ω
150Ω
nQn
FB
IDT5V996
FBOUT
PCBTRACE
3Q0
REF
CF
2
0.8
VTH
tRtF
3V
VTH =VDDQ/2
0V
20pF
150Ω
150Ω
OUTPUT
AC TEST LOADS AND WAVEFORMS
Output Waveform
Input Waveform
AC Load
NOTES:
1. VTH = VDDQ/2.
2. CF = CL - CFBIN - CPCBTRACE; CFBIN6pF
3. Calculations were done by adjusting the input slew rate to match with the output slew rate.
Static Phase Offset and Skew Calculations (2,3)
8
INDUSTRIAL TEMPERATURE RANGE
IDT5V996
3.3V PROGRAMMABLE SKEW PLL CLOCK DRIVER TURBOCLOCK II PLUS
AC TIMING DIAGRAM
tJ
REF
FB
Q
OTHER Q
INVERTED Q
REF DIVIDED BY 2
REF DIVIDED BY 4
tREF
tSK(INV)
tSKEW1,4
tSK(ω)
tSK(INV)
tSKEWPR
tSK(O)
tRPWH
tRPWL
tSKEWPR
tSK(O)
t(φ)
tSK(ω)
tSKEW1,4
tSK(ω)
tODCV tODCV
NOTES:
SE: The AC Timing Diagram applies to SE=VDD. For SE=GND, the negative edge of FB aligns with the negative edge of REF, divided outputs change on the negative edge
of REF, and the positive edges of the divide-by-2 and the divide-by-4 signals align.
Skew: The time between the earliest and the latest output transition among all outputs for which the same tU delay has been selected when all are loaded with 20pF and terminated
with 75Ω to VDDQ/2.
tSKEWPR: The skew between a pair of outputs (xQ0 and xQ1) when all eight outputs are selected for 0tU.
tSK(0): The skew between outputs when they are selected for 0tU.
tDEV: The output-to-output skew between any two devices operating under the same conditions (VDDQ, VDD, ambient temperature, air flow, etc.)
tODCV: The deviation of the output from a 50% duty cycle. Output pulse width variations are included in tSKEW1 and tSKEW4 specifications.
tSK(ω): The skew between outputs of different frequencies.
tSK(INV): The skew between inverting and non-inverting outputs.
tR and tF are measured between 0.8V and 2V.
tLOCK: The time that is required before synchronization is achieved. This specification is valid only after VDD/VDDQ is stable and within normal operating limits. This parameter
is measured from the application of a new signal or frequency at REF or FB until tPD is within specified limits.
9
INDUSTRIAL TEMPERATURE RANGE
IDT5V996
3.3V PROGRAMMABLE SKEW PLL CLOCK DRIVER TURBOCLOCK II PLUS
ORDERING INFORMATION
IDT XXXXX
Package
Device Type
5V996 3.3V Programmable Skew PLL Clock Driver
TurboClock II Plus
Plastic Ball Grid Array
BB
XX
Process
X
-40°C to +85°C (Industrial)
I
CORPORATE HEADQUARTERS for SALES: for Tech Support:
6024 Silver Creek Valley Road 800-345-7015 or 408-284-8200 clockhelp@idt.com
San Jose, CA 95138 fax: 408-284-2775
www.idt.com