Miniature controls Miniature controls * Contactors * Overload relays * Starters * Control relays Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls 4 Description General features * Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections * Low power consumption coils * Touch safe design: All screw connection terminals are protected against accidental touch * Slotted Pozidriv terminal screws * Screwdriver guide holes * Self-lifting cable clamps * Panel or DIN rail mounting * Terminals supplied in the open position * Electrically noiseless operation * Snap-on accessories * UL Listed, file # E39231 * CSA approved, file #LR15332 * IEC, VDE & most international standards Mechanically interlocked contactors * Compact, mechanically interlocked contactors are available * Can be used for reversing applications Control relays * AC & DC operated Overload relays * * * * * * * 14 setting ranges from 0.11 to 10.5 amps Manual or automatic reset Phase failure compensation Ambient temperature compensation Stop and test button functions UL Listed, file #E149922 CSA approved, file # LR98336 Contactors * B6 and BC6 miniature contactors can be used for small motors up to 1 HP, 460V * B7 and BC7 miniature contactors can be used for small motors up to 5 HP, 460V * Applications include use in machines, electrical appliances, building automation systems, heating systems, overhead door applications, etc. * B6 and B7 miniature contactors are designed to be directly connected to a PLC transistor output Interface contactors * "Interface" mini-contactors are normally used to establish an isolation between the electronic part and the process in large automation systems 4.1 1SXU000023C0202 Contactors B6 & B7, non-reversing 3 Phase re tu ls a i in ro M ont C Non-reversing with screw connections General purpose AC1 4 B6C-1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles Catalog number List price AC operated 12 6.8 1 2 3 1 1/2 1 3 3 4 1 N.O. 1 N.C. -- B6-30-10- B6-30-01- B6-40-00- $ 51 16 9.6 2 3 5 5 1 2 3 3 4 1 N.O. 1 N.C. -- B7-30-10- B7-30-01- B7-40-00- 72 12 6.8 1 2 3 1 1/2 1 3 3 1 N.O. 1 N.C. BC6-30-10- BC6-30-01- 57 16 9.6 2 3 5 5 1 2 3 3 1 N.O. 1 N.C. BC7-30-10- BC7-30-01- 78 DC operated Non-reversing with flat pin connections General purpose AC1 B7C-1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles Catalog number List price AC operated 12 6.8 1 2 3 1 1/2 1 3 3 4 1 N.O. 1 N.C. -- B6-30-10-F B6-30-01-F B6-40-00-F $ 51 16 9.6 2 3 5 5 1 2 3 3 4 1 N.O. 1 N.C. -- B7-30-10-F B7-30-01-F B7-40-00-F 72 12 6.8 1 2 3 1 1/2 1 3 3 1 N.O. 1 N.C. BC6-30-10-F BC6-30-01-F 57 16 9.6 2 3 5 5 1 2 3 3 1 N.O. 1 N.C. BC7-30-10-F BC7-30-01-F 78 DC operated B6CFP-1 Non-reversing with soldering pin connections General purpose AC1 B7CSP-1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles Catalog number List price AC operated 12 6.8 1 2 3 1 1/2 1 3 3 4 1 N.O. 1 N.C. -- B6-30-10-P B6-30-01-P B6-40-00-P $ 51 16 9.6 2 3 5 5 1 2 3 3 4 1 N.O. 1 N.C. -- B7-30-10-P B7-30-01-P B7-40-00-P 72 1/2 1 12 6.8 1 2 3 1 3 3 1 N.O. 1 N.C. BC6-30-10-P BC6-30-01-P 57 16 9.6 2 3 5 5 1 2 3 3 1 N.O. 1 N.C. BC7-30-10-P BC7-30-01-P 78 DC operated Coil voltage selection Coil voltage suffix. Refer to Coil Voltage Selection Chart and substitute the desired coil voltage suffix for the . Coil voltage selection chart Volts 12 24 42 48 110/125 110/120 220 AC 40-450 Hz DC 4.2 1SXU000023C0202 U F L G Y V W 1 P Discount schedule MB 220/240 380/415 2 M R Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls Contactors B6 & B7, mechanically interlocked 3 Phase Mechanically interlocked with screw connections General purpose AC1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles AC operated List price 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. VB6-30-10- VB6-30-01- $ 104 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. VB7-30-10- VB7-30-01- 143 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. VBC6-30-10- VBC6-30-01- 105 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. VBC7-30-10- VBC7-30-01- 156 DC operated VB6M-1 Catalog number Mechanically interlocked with flat pin connections General purpose AC1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles AC operated VB7M-1 Catalog number List price 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. VB6-30-10-F VB6-30-01-F $ 104 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. VB7-30-10-F VB7-30-01-F 143 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. VBC6-30-10-F VBC6-30-01-F 105 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. VBC7-30-10-F VBC7-30-01-F 156 Catalog number List price DC operated Mechanically interlocked with soldering pin connections General purpose AC1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles AC operated 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. VB6-30-10-P VB6-30-01-P $ 104 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. VB7-30-10-P VB7-30-01-P 143 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. VBC6-30-10-P VBC6-30-01-P 105 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. VBC7-30-10-P VBC7-30-01-P 156 DC operated Coil voltage selection Coil voltage suffix. Refer to Coil Voltage Selection Chart and substitute the desired coil voltage suffix for the . Coil voltage selection chart Volts 12 24 42 48 110/125 110/120 220 AC 40-450 Hz DC Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com U F L G Y V W 1 P Discount schedule MB 220/240 380/415 2 M R 4.3 1SXU000023C0202 4 re tu ls a i in ro M ont C Contactors 1 B6 & B7, Interface 3 Phase Non-reversing with screw connections General purpose AC1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles DC operated -- 24VDC (1.4W low power consumption) 4 List price 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. BC6-30-10-1.4 BC6-30-01-1.4 $ 57 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. BC7-30-10-1.4 BC7-30-01-1.4 80 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. BC6-30-10-2.4 BC6-30-01-2.4 63 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. BC7-30-10-2.4 BC7-30-10-2.4 80 DC operated -- 17 - 32VDC (2.4W low power consumption) BC6-2.4 Catalog number Non-reversing with flat pin connections General purpose AC1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles DC operated -- 24VDC (1.4W low power consumption) BC7-2.4 Catalog number List price 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. BC6-30-10-F1.4 $ 57 BC6-30-01-F1.4 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. BC7-30-10-F1.4 BC7-30-01-F1.4 80 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. BC6-30-10-F2.4 BC6-30-01-F2.4 63 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. BC7-30-10-F2.4 BC7-30-01-F2.4 80 DC operated -- 17 - 32VDC (2.4W low power consumption) Non-reversing with soldering pin connections General purpose AC1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles DC operated -- 24VDC (1.4W low power consumption) Catalog number List price 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. BC6-30-10-P1.4 $ 57 BC6-30-01-P1.4 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. BC7-30-10-P1.4 BC7-30-01-P1.4 80 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. BC6-30-10-P2.4 BC6-30-01-P2.4 63 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. BC7-30-10-P2.4 BC7-30-01-P2.4 80 DC operated -- 17 - 32VDC (2.4W low power consumption) 1 Interface contactors cannot utilize auxiliary contacts. 4.4 1SXU000023C0202 Discount schedule MB Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls Contactors for connection to PLCs 1 3 Phase Non-reversing with screw connections General purpose AC1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles DC operated -- 24VDC (1.4W low power consumption) List price 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. B6S-30-10-1.7 B6S-30-01-1.7 $ 65 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. B7S-30-10-1.7 B7S-30-01-1.7 69 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. B6S-30-10-2.8 B6S-30-01-2.8 65 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. B7S-30-10-2.8 B7S-30-01-2.8 69 DC operated -- 17 - 32VDC (2.4W low power consumption) B6SC-2.8 Catalog number B7SC-2.8 Oscillograms typical operation without internal surge suppression 24 V 0 -1000 V 0 280 s Switching off of interface contactors BC6, BC7, coil voltage 24 VDC. with internal surge suppression 24V 0 0 switch off Switching off of B6S, B7S coil voltage 24VDC which provides electrically noiseless operation 1 Contactors for connection to PLCs cannot utilize auxiliary contacts. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com Discount schedule MB 4.5 1SXU000023C0202 4 Thermal overload relays T7DU re tu ls a i in ro M ont C Thermal overload relay -- for contactors B6,B7, BC6, BC7, B6S, B7S, VB6(7), VBC6(7), VB6A(7A), VBC6A(/7A) Setting range Amps 4 T7DU Catalog number 0.1 - 0.16 0.16 - 0.24 0.24 - 0.4 T7DU0.16 T7DU0.24 T7DU0.4 0.4 - 0.6 0.6 - 1.0 1.0 - 1.6 T7DU0.6 T7DU1.0 T7DU1.6 1.6 - 2.4 2.4 - 4.0 4.0 - 6.0 T7DU2.4 T7DU4.0 T7DU6.0 6.0 - 9.0 9.0 - 12.0 T7DU9.0 T7DU12.0 List price $ 48 Loading capacity of auxiliary switches Type T7DU N.C. N.O. 95 - 96 97 - 98 Rated operating voltage Ue/V IEC / UL508 Thermal current Rated operating current Ie at AC-15 at AC-15 at AC-15 at DC-15 220/240 V 380/415 V 500 V 220 V V 500 / 300 500 / 300 A 6 6 A A A A 1.5 0.7 0.5 0.2 1.5 0.5 0.3 0.2 Pilot duty rating AC DC A300 P300 A300 P300 General use 240V 600V 1.5A 0.6A 1.5A 0.6A Thermal overload relay T7DU Setting rangeShort circuit protection (fuses, circuit breakers) Coordination Type 2 (IEC) Coordination Type 1(IEC) 600V, 5kA Resistance per phase gL/gG gL/gG Fuse MCCB A-A A A W 0.1 0.16 0.24 0.4 0.6 1.0 1.6 2.4 4.0 6.0 9.0 - - - - - - - - - - - 0.16 0.24 0.4 0.6 1.0 1.6 2.4 4.0 6.0 9.0 12.0 0.5 1 2 2 4 6 6 10 10 10 20 20 20 20 20 20 20 20 20 20 20 20 1 1 1 1 3 6 6 15 20 35 45 15A 15A 15A 15A 15A 15A 15A 15A 15A 15A 15A 62.3 27 11.7 4.61 1.66 0.63 0.27 0.107 0.049 0.021 0.010 Joule losses per phase at upper current setting W 1.6 1.6 1.9 1.7 1.7 1.6 1.6 1.7 1.8 1.7 1.4 Electronic overload relays See pages 2.19 to 2.30. 4.6 1SXU000023C0202 Discount schedule MB Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls Starters 1 B6 & B7, non-reversing 3 Phase Non-Reversing, 3 phase - Screw connections only General purpose AC1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles AC operated Catalog number List price 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. B6S- B6S-01 $ 108 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. B7S- B7S-01 132 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. BC6S- BC6S-01 114 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. BC7S- BC7S-01 138 DC operated Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the . Overload relay suffix. Refer to the Overload Relay Selection chart and substitute the desired starter suffix code for the . B6S- Reversing, 3 phase - Screw connections only General purpose AC1 Maximum 3 Phase motor horsepower motor FLA AC3 208V 230V 460V 600V Single phase 120V 230V Number of Auxiliary power contacts poles AC operated Catalog number List price 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. B6SR- B6SR-01 $ 179 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. B7SR- B7SR-01 218 12 6.8 1 2 3 1 1/2 1 3 1 N.O. 1 N.C. BC6SR- BC6SR-01 180 16 9.6 2 3 5 5 1 2 3 1 N.O. 1 N.C. BC7SR- BC7SR-01 231 DC operated Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the . Overload relay suffix. Refer to the Overload Relay Selection chart and substitute the desired starter suffix code for the . Coil voltage selection 12 24 42 48 AC 40-450 Hz F L G Y V W DC U 110/125 Volts 110/120 220 1 P 220/240 380/415 2 M R Overload relay selection E16DU - Electronic overload T7DU - Thermal overload Catalog number T7DU0.16 T7DU0.24 T7DU0.4 T7DU0.6 T7DU1.0 T7DU1.6 T7DU2.4 T7DU4.0 T7DU6.0 T7DU9.0 T7DU12.0 Current setting range 0.1 0.16 0.24 0.4 0.6 1.0 1.6 2.4 4.0 6.0 9.0 - - - - - - - - - - - 0.16 0.24 0.4 0.6 1.0 1.6 2.4 4.0 6.0 9.0 12.0 Starter range code A B C D E F G H J K L Catalog number Current setting range Current tripping class Starter range code E16DU0.32-10 E16DU1.0-10 E16DU2.7-10 E16DU6.3-10 E16DU18.9-10 0.1 0.3 0.9 2.0 5.7 - - - - - 0.32 1.0 2.7 6.3 18.9 10 10 10 10 10 A1 B1 C1 D1 E1 E16DU0.32-20 E16DU1.0-20 E16DU2.7-20 E16DU6.3-20 E16DU18.9-20 0.1 0.3 0.9 2.0 5.7 - - - - - 0.32 1.0 2.7 6.3 18.9 20 20 20 20 20 A2 B2 C2 D2 E2 E16DU0.32-30 E16DU1.0-30 E16DU2.7-30 E16DU6.3-30 E16DU18.9-30 0.1 0.3 0.9 2.0 5.7 - - - - - 0.32 1.0 2.7 6.3 18.9 30 30 30 30 30 A3 B3 C3 D3 E3 1 For enclosed miniature starters, please consult factory for catalog number and pricing. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com Discount schedule MB 4.7 1SXU000023C0202 4 re tu ls a i in ro M ont C Starters 1 B6 & B7, Non-reversing Single phase Non-Reversing, Single phase - Screw connections only General purpose AC1 Maximum Single phase motor FLA AC3 120V 230V Number of power poles AC operated 4 Auxiliary contacts Catalog number List price 12 6.8 1/2 1 3 1 N.O. 1 N.C. B6SS- B6SS-01 $ 108 16 9.6 1 2 3 1 N.O. 1 N.C. B7SS- B7SS-01 132 12 6.8 1/2 1 3 1 N.O. 1 N.C. BC6SS- BC6SS-01 114 16 9.6 1 2 3 1 N.O. 1 N.C. BC7SS- BC7SS-01 138 DC operated Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the . Overload relay suffix. Refer to the Overload Relay Selection chart and substitute the desired starter suffix code for the . Coil voltage selection 12 24 42 48 AC 40-450 Hz F L G Y V W DC U 110/125 Volts 110/120 220 1 P 220/240 380/415 2 M R Overload relay selection T7DU - Thermal overload Catalog number T7DU0.16 T7DU0.24 T7DU0.4 T7DU0.6 T7DU1.0 T7DU1.6 T7DU2.4 T7DU4.0 T7DU6.0 T7DU9.0 T7DU12.0 Current setting range 0.1 0.16 0.24 0.4 0.6 1.0 1.6 2.4 4.0 6.0 9.0 - - - - - - - - - - - 0.16 0.24 0.4 0.6 1.0 1.6 2.4 4.0 6.0 9.0 12.0 Starter range code A B C D E F G H J K L 1 For enclosed miniature starters, please consult factory for catalog number and pricing. 4.8 1SXU000023C0202 Discount schedule MB Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls Control relays K622 - K640 AC & DC operated Control relays with screw connections Contact configuration N.O. N.C. AC Operated DC Operated K640-1 Catalog number 4 3 2 0 1 2 K640E- K631Z- K622Z- 4 3 2 0 1 2 KC6-40E- KC6-31Z- KC6-22Z- List price $ 48 54 Control relays with flat pin connections Contact configuration N.O. N.C. AC Operated DC Operated Catalog number List price 4 3 2 0 1 2 K6-40E-F K6-31Z-F K6-22Z-F 4 3 2 0 1 2 KC6-40E-F KC6-31Z-F KC6-22Z-F 54 Catalog number List price $ 48 Control relays with soldering pin connections KC631-1 Contact configuration N.O. N.C. AC Operated DC Operated 4 3 2 0 1 2 K6-40E-P K6-31Z-P K6-22Z-P 4 3 2 0 1 2 KC6-40E-P KC6-31Z-P KC6-22Z-P $ 48 54 Coil voltage selection Coil voltage suffix. Refer to Coil Voltage Selection Chart and substitute the desired coil voltage suffix for the . Coil voltage selection chart Volts 12 24 42 48 110/125 110/120 220 AC 40-450 Hz DC Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com U F L G Y V W 1 P Discount schedule MB 220/240 380/415 2 M R 4.9 1SXU000023C0202 4 Interface relays 1 KC631 - KC640 DC operated re tu ls a i in ro M ont C Interface relays with screw connections Contact configuration N.O. N.C. 4 Catalog number List price DC Operated -- 24VDC (1.4W low power consumption) 4 0 3 1 KC6-40E-1.4 KC6-31Z-1.4 $ 59 DC Operated -- 17 - 32VDC (2.4W low power consumption) 4 0 3 1 KC6-40E-2.4 KC6-31Z-2.4 59 Interface relays with flat pin connections KC640-1.4 Contact configuration N.O. N.C. Catalog number List price DC Operated -- 24VDC (1.4W low power consumption) 4 0 3 1 KC6-40E-F1.4 KC6-31Z-F1.4 $ 59 DC Operated -- 17 - 32VDC (2.4W low power consumption) 4 0 3 1 KC6-40E-F2.4 KC6-31Z-F2.4 59 Catalog number List price DC Operated -- 24VDC (1.4W low power consumption) 4 0 3 1 KC6-40E-P1.4 KC6-31Z-P1.4 $ 59 DC Operated -- 17 - 32VDC (2.4W low power consumption) 4 0 3 1 KC6-40E-P2.4 KC6-31Z-P2.4 59 Interface relays with soldering pin connections Contact configuration N.O. N.C. BC7-2.4 1 Interface relays cannot utilize auxiliary contacts. 4.10 1SXU000023C0202 Discount schedule MB Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls Accessories for B6 & B7 contactors Auxiliary contact blocks Item description CA6-11K CA6-11E-F Contact configuration Catalog number 1 Side mounted auxiliary contact blocks, 1 N.O. & 1 N.C. Screw connection type * KC6 & K6 relay * B6 or BC6; B7 or BC7 4 pole contactor * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O. * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C. 1 N.O. & 1 N.C. 1 N.O. & 1 N.C. 1 N.O. & 1 N.C. 1 N.O. & 1 N.C. CA6-11K CA6-11E CA6-11M CA6-11N Flat pin connection type * KC6 & K6 relay * B6 or BC6; B7 or BC7 4 pole contactor * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O. * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C. 1 N.O. & 1 N.C. 1 N.O. & 1 N.C. 1 N.O. & 1 N.C. 1 N.O. & 1 N.C. CA6-11K-F CA6-11E-F CA6-11M-F CA6-11N-F Soldering pin connection type * KC6 & K6 relay * B6 or BC6; B7 or BC7 4 pole contactor * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O. * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C. 1 N.O. & 1 N.C. 1 N.O. & 1 N.C. 1 N.O. & 1 N.C. 1 N.O. & 1 N.C. CA6-11K-P CA6-11E-P CA6-11M-P CA6-11N-P Front mounted auxiliary contact blocks, 1 N.O. & 1 N.C. Screw connection type * KC6 & K6 relay 1 N.O. & 1 N.C. * KC6 & K6 relay 2 N.O. & 0 N.C. * KC6 & K6 relay 0 N.O. & 2 N.C. * B6 or BC6; B7 or BC7 4 pole contactor, VB(C)... 1 N.O. & 1 N.C. * B6 or BC6; B7 or BC7 4 pole contactor, VB(C)... 2 N.O. & 0 N.C. * B6 or BC6; B7 or BC7 4 pole contactor, VB(C)... 0 N.O. & 2 N.C. * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O., VB(C)... 1 N.O. & 1 N.C. * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O., VB(C)... 2 N.O. & 0 N.C. * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O., VB(C)... 0 N.O. & 2 N.C. * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C., VB(C)... 1 N.O. & 1 N.C. * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C., VB(C)... 2 N.O. & 0 N.C. * B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C., VB(C)... 0 N.O. & 2 N.C. List price 4 $ 15 CAF6-11K CAF6-20K CAF6-02K CAF6-11E CAF6-20E CAF6-02E CAF6-11M CAF6-20M CAF6-02M CAF6-11N CAF6-20N CAF6-02N Soldering connection Item description CA6-11K-P For mini contactors, B, BC, K, & KC For 2 pole auxiliary contacts Catalog number LB6 LB6-CA List price $ 15 8 Plunger Item description For manual operation CAF6- 11M Catalog number BN6 List price $ 15 Identification labels Item description 50 clip-on label holders, 60 non-adhesive labels 50 transparent covers, 75 self adhesive labels Catalog number BA50 List price $ 30 BA 50 1 Miniature contactors and control relays can use either front or side mounted auxiliary blocks but not both. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com Discount schedule MB 4.11 1SXU000023C0202 Accessories for B6 & B7 contactors re tu ls a i in ro M ont C Surge supressors Item Voltage description Varistor type surge suppressor for DC operated coils 4 24 - 60V 110 - 250V 200 - 420V Catalog number List price RV-BC6/60 RV-BC6/250 RV-BC6/380 $ 24 Catalog number List price Protective cover Item description RV-BC6/... For contactors B, BC, K, & KC6 with screw connection LT6-B $ 15 Reversing connection link Item description For compact interlocking contactors with screw connection Catalog number BSM6-30 List price $ 12 LT6-B Line side (L) Load side (T) BSM6-30 4.12 1SXU000023C0202 Discount schedule MB Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls IEC Technical data D.C. Power circuit switching Utilization category + - + - + - DC-1 L/R 1 ms DC-3 L/R 2 ms DC-5 L/R 7.5 ms 24 V 48 V 60 V 110 V 220 V A A A A A 16.0 16.0 16.0 7.0 0.8 16.0 8.0 4.0 1.5 0.25 16.0 2.0 1.25 0.4 0.2 24 V 48 V 60 V 110 V 220 V A A A A A 16.0 16.0 16.0 16.0 5.0 16.0 16.0 15.0 7.0 1.5 16.0 16.0 12.0 2.0 0.5 24 V 48 V 60 V 110 V 220 V A A A A A 16.0 16.0 16.0 16.0 14.0 16.0 16.0 16.0 15.0 4.0 16.0 16.0 16.0 8.0 2.0 4 Electrical durability curves for DC-1, DC-3 and DC-5 The curves below take into account the time constant L/R for each utilization category and show the electrical durability of the contactors during DC-1, DC-3 and DC-5 use for 3 poles connected in series. If one single pole is used, the corresponding breaking capacity (W) is reduced to 1/3 and for 2 poles connected in series it is reduced to 2/3. 3 poles in series 3 poles in series 3 poles in series Millions of operating cycles A = DC-1 B = DC-3 C = DC-5 Breaking power (W) Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com 4.13 1SXU000023C0202 IEC Technical data B6 Contactors & K6 control relays Auxiliary contacts & magnetic coils re tu ls a i in ro M ont C B6 contactors Endurance curves - B 6, BC 6, B 6S Rated insulating voltage 10 8 6 5 4 3 4 Permissible ambient temperature Contactor without relay Contactor with relay Storage temperature Millions of operations 2 Climatic resistance 1 0.8 0.6 0.5 0.4 0.3 C C C - 25 ... + 55 - 25 ... + 50 - 40 ... + 80 acc. to DIN 50 017 acc. to UTE C 63-100 alternating climate proof 30 cycles, version 1 optional Mechanical endurance 10 million operations 0.2 Max. switching frequency 0.1 0.08 0.06 0.05 0.04 0.03 AC 1 cyc./h AC 2/AC 3 cyc./h Rated operating current Ie/AC 1, AC 3 AC 1/Ie AAC 2, AC 3 Rated operating voltage Ve AC1 AC3 1 1. 2 3 4 53 6 8 10 15 20 Rated operating current [A] Endurance curves - B 6, BC 6, B 6S Switching times 10 8 6 5 4 3 2 1 0.8 0.6 0.5 0.4 0.3 12 to 500 55 C 40 C 220/240 V 380/440 V 500 V 0 300 600 V AC Rated operating power 0.01 Millions of operations 500 Mounting position 0.02 Ie A P kW 16 16 12 20 20 12 9 9/8 5.5 2.2 4.0 3.0 B6 BC6 K6 KC6 Closing delay NO ms 20 to 26 20 to 26 Opening delay NO ms 16 to 20 4 to 6 16 to 20 4 to 6 Closing delay NC ms 16 to 20 4 to 6 16 to 20 4 to 6 Opening delay NC ms 14 to 18 14 to 18 K6 Control relays & auxiliary contacts 0.2 AC4 0.1 0.08 0.06 0.05 0.04 0.03 Rated operating voltage Ve VDC VAC Conventional rated thermal current Ith A 6 220/240 V 380/440 V 500 V A A A 4 3 2 24 V 60 V 110 V 220/240 V A A A A 2.5 1.2 0.7 0.4 Rated operating current Ie/ AC 15 at Ve 0.02 0.01 1 1.5 2 3 4 53 6 8 10 15 20 0 Switch off current [A] Rated operating current Ie/DC 13 at Ve Endurance curves - K6, KC6, CA6, CAF6 10 5 Millions of operations Vi 12 to 240 12 to 500 Magnetic coils Coil voltage range Basic contactors B6 / K6, VB6 AC VA BC6 / KC 6, VBC6 DC W 2 AC 15 1 Interface contactors BC6 / KC6-1.4 DC BC6 / KC6-2.4 DC 0.5 * 24 * V W 17 ... 32 V W 1.4 2.4 Mini contactor for connection to PLC's 0.2 0.1 0.01 0.02 0.05 0.1 0.2 0.5 1 2 3 5 0.8 ...1.1x Uc closing /holding 3.5 3.5 cold warm I mA P W I mA PW B6 S-1.7 B6 S-2.8 77 125 1.75 2.80 60 94 1.35 2.10 DC DC + 24 + V W + 17 ... 32 +V W 10 Switch off current (A) 4.14 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls IEC Technical data B7 contactors Magnetic coils B7 contactors Rated insulating voltage Permissible ambient temperature Contactor without relay Contactor with relay Storage temperature Endurance curves - B 7, BC 7, B 7S 10 8 6 5 4 3 Climatic resistance Millions of operations 500 C C C - 25 ... + 55 - 25 ... + 50 - 40 ... + 80 acc. to DIN 50 017 acc. to UTE C 63-100 Mechanical endurance 1 0.8 0.6 0.5 0.4 0.3 4 alternating climate proof 30 cycles, version 1 Mounting position 2 optional 10 million operations Max. switching frequency AC 1 AC 2/AC 3 Rated operating voltage Ve cyc./h cyc./h 300 600 VAC 12 to 500 0.2 Rated operating current Ie/AC 1, AC 3 AC 1/Ie AAC 2, AC 3 0.1 0.08 0.06 0.05 0.04 0.03 Rated operating power 55 C 40 C 220/240 V 380/440 V 500 V AC3 AC1 0.02 16 16 12 Switching times 0.01 1 1.5 2 3 4 5 6 8 10 15 20 30 Rated operating current 10 8 6 5 4 B7 12/11 12/11 7 3 5.5 4 BC7 ms Closing delay NC Opening delay ms 16 to 20 4 to 6 ms 14 to 18 16 to 20 4 to 6 1/2 sinusoidal shock, 10 ms: no change in contact position shock directions A contactor switched on 20 g A A contactor switched off 10 g B1 3L2 1L1 5L3 13NO A1 1 0.8 0.6 0.5 0.4 0.3 P kW ms 20 to 26 C1 2 20 20 12 Ie A Closing delay NO Opening delay Shock resistance B6, B7 standard mounting position 3 Millions of operations Vi B1 20 g 20 g B2 20 g 20 g C1 20 g 20 g C2 20 g 20 g 0 A2 2T1 4T2 6T3 14NO B2 C2 0.2 AC4 0.1 0.08 0.06 0.05 0.04 0.03 Magnetic Coils 0.02 0.01 1 1.5 2 3 4 5 6 8 10 Switch off current [A] 15 20 0 Coil voltage range 0.8...1.1x Uc Rated power of magnetic coils Basic contactors B7 / VB7 AC VA BC7 / VBC7 DC W closing /holding 3.5 3.5 Interface contactors BC7-1.4 DC + 24 V BC7-2.4 DC +17 ... 32 V W W 1.4 2.4 Mini contactor for connection to PLC's cold warm I (mA) P (W) I (mA) P (W) B7 S-1.7 B7 S-2.8 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com DC DC + 24 V +17 ... 32 V 77 125 1.75 2.80 60 94 1.35 2.10 4.15 1SXU000023C0202 IEC Technical data re tu ls a i in ro M ont C Switching of light fittings Endurance curves for DC1, DC3, DC5 The following tables show the number of lamps which can be connected per phase at 230 V/ 60 Hz. Note the following: The following shows endurance curves for DC1, DC3 and DC5 for 3 poles in series. If only one current path is used, the corresponding breaking capacity is multiplied by 0.33, for two current paths by 0.66. a) Increased current consumption for 1.1 times the rated voltage is 4 considered. Varying time constants L/R (ms) have been considered. b) Failure of about 5% of the lamps is considered since not ignited lamps additionally charge the contactor with their preheating current. 10 Lamp type Lamp data Permissible number of lamps per phase (230 V, 60 Hz) for contactor type Watt cm A B6, B7, BC6, BC7 Incandescent lamps 60 100 200 300 500 1000 0.27 0.45 0.91 1.36 2.27 4.5 20 12 6 4 2 1 25 23 20 16 12 5 5 Fluorescent lamps uncompensated 15 20 40 42 65 115 140 44 59 120 105 150 120 150 0.35 0.37 0.43 0.54 0.67 1.5 1.5 Fluorescent lamps in two-lamp circuit 2 x 20 2 x 40 2 x 42 2 x 65 2 x 115 2 x 140 59 120 105 150 120 150 2 x 0.13 2 x 0.22 2 x 0.24 2 x 0.34 2 x 0.65 2 x 0.75 Metal halogen lamps uncompensated 35 70 150 250 400 0.53 1.0 1.8 3.0 3.5 10 5 3 2 1 Low pressure sodium vapor lamps uncompensated 35 55 90 135 150 180 200 1.5 1.5 2.4 3.5 3.3 3.3 2.3 4 4 2 2 2 2 2 High pressure mercury vapor lamps uncompensated 150 250 330 400 1.8 3.0 3.7 4.7 3 2 2 1 High pressure mercury vapor lamps uncompensated 50 80 125 250 400 700 0.61 0.8 1.15 2.15 3.25 5.40 10 7 5 3 2 1 4.16 1SXU000023C0202 Millions of operations c) This data only apply to connection of the lamps at main pole terminals 1 ...8 5 4 3 2 1.5 1 A 0.5 0.4 0.3 B 0.2 0.15 C 0.1 0.05 0.04 0.03 15 20 30 40 50 100 150 200 300 400 500 Switch off power (W) 1000 A = 3 poles in series DC 1 B = 3 poles in series DC 3 C = 3 poles in series DC 5 2 x 26 lamp 2 x 20 pairs 2 x 16 2 x 12 2 x 5 2x 5 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls IEC Technical data Pole configurations Miniature contactors 1 3 5 7 1 A1 3 5 13 A1 1 3 5 21 A1 4 2 4 6 8 2 A2 B6(7)-40-00 ... BC6(7)-40-00 ... 4 6 14 A2 2 B6(7)-30-10 ... BC6(7)-30-10 ... 4 6 22 A2 B6(7)-30-01 ... BC6(7)-30-01 ... Miniature mechanically interlocked contactors A1 13 1 3 5 1 3 5 13 A1 A2 14 2 4 6 2 4 6 14 A2 A1 21 1 3 5 1 3 5 21 A1 A2 22 2 4 6 2 4 6 22 A2 VB6(7)-30-01 ... VBC6(7)-30-01 ... VB6(7)-30-10 ... VBC6(7)-30-10 ... Miniature control relays 13 33 43 21 A1 13 23 33 43 A1 13 43 21 31 A1 14 24 34 44 A2 14 34 44 22 A2 14 44 22 32 K6-40 E ... KC6-40 E ... K6-31 Z ... KC6-31 Z ... K6-22 Z ... KC6-22 Z ... Side mounted auxiliary contact blocks CA6-11E CA6-11E-F CA6-11E-P 13 21 22 14 CA6-11M CA6-11M-F CA6-11M-P 33 21 22 34 CA6-11N CA6-11N-F CA6-11N-P 13 31 32 14 CA6-11K CA6-11K-F CA6-11K-P 1 3 5 Front mounted auxiliary contact blocks 1 7 3 B6(7)-40-00 B6(7)-40-00-F B6(7)-40-00-P BC6(7)-40-00 2 4 6 8 1 3 5 13 5 2 4 6 8 1 3 5 13 CAF6 ... 2 4 6 14 2 4 6 14 1 3 5 21 1 3 5 21 B6(7)-30-01 B6(7)-30-01-F B6(7)-30-01-P BC6(7)-30-01 4 53 61 6 40 E 31Z 62 54 22Z CAF6 ... 2 22 K6 ... K6 ... F K6 ...P KC6 ... 4 6 40 E 31Z 22Z 13 21 7 CAF6 ... B6(7)-30-10 B6(7)-30-10-F B6(7)-30-10-P BC6(7)-30-10 2 A2 13 23 11 21 B6(7)-40-00 B6(7)-40-00-F B6(7)-40-00-P BC6(7)-40-00 1 = CAF6-11E 2 = CAF6-20E 3 = CAF6-02E 14 22 14 24 12 22 33 21 23 33 21 31 B6(7)-30-10 B6(7)-30-10-F B6(7)-30-10-P BC6(7)-30-10 1 = CAF6-11M 2 = CAF6-20M 3 = CAF6-02M 34 22 24 34 22 32 13 31 13 33 11 31 B6(7)-30-01 B6(7)-30-01-F B6(7)-30-01-P BC6(7)-30-01 22 1 = CAF6-11N 2 = CAF6-20N 3 = CAF6-02N 14 32 14 34 12 32 53 61 13 33 51 61 K6 ... K6 ... F K6 ...P KC6 ... 1 = CAF6-11K 2 = CAF6-20K 3 = CAF6-02K 54 62 14 34 52 62 1 2 3 NOTE: Only side mounted type or front mounted type auxiliary contact blocks can be used at one time. Auxililiary contact blocks must not be mounted on Interface contactors, Interface control relays or contactors for connection to PLCs. Two CAF 6 front mounted auxiliary contact blocks can installed on the mechanically interlocked contactors VB(C)6(7). Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com 4.17 1SXU000023C0202 IEC technical data Overload relays re tu ls a i in ro M ont C Type 4 T7DU Standards: (major international and European standards) IEC 947-4-1, UL 508 EN 60 947-4-1 Approvals, certificates Rated insulation voltage Ui acc. to IEC 158-1, IEC 947-4-1 V acc. to IEC / UL 508Ui/V660V / 600V UL, CSA 690V Impulse withstand voltage UimpkV6 acc. to IEC 947-4-1 Permissible ambient temperature * for storage C -40 to 70 * with compensated operation C - open C -25 to + 50C - enclosed C -25 to + 40C Climatic resistance according to IEC 68-2-3, IEC 68-2-30 Mounting position 30 from vertical position not horizontally, not upside down Side by side mounting distance, 5mm Resistance to shock Shock duration ms 10 *Critical shock direction A1, A2 multiple of g 10 Resistance to vibrations -- (1 mm, 50 Hz) multiple of g Mounting * on contactor Hooking underneath the contactor, screwing on its main terminal Terminal types and connecting capacity of main conductors (on motor side) * Screw terminals (screw size) * with self-disengaging clamping piece M3.5 * with terminal block -- * with busbar or cable lugs -- * connection cross sections 2 x 18 - 14 / 2 x 0.75 - 2.5 * single-core or stranded Awg/mm2 mm2 2 x 0.5 - 1.5 * flexible with connector sleeve Terminals and auxiliary conductors * Screw terminals (screw size) * with self-disengaging clamping piece M3.5 * connection cross sections 2 x 18 - 14 / 2 x 0.75 - 2.5 * single-core or stranded Awg/mm2 mm2 2 x 0.5 - 1.5 * flexible with connector sleeve Protection degree to IEC 947-1/EN 60 947-1 All terminals are safe from finger-touch and touch by the back of the hand in accordance with VDE 0106, Part 100 Power pole technical data Number of poles 3 Setting ranges see order codes Tripping class acc. to IEC 947-4-1/EN 60 947-4-1 Frequency limit 10A Hz 0 - 400 Switching frequency up to 15 ops./h or 60 ops./h with 40% on load factor without early tripping if starting current not higher than 6 x In and starting time not longer than 1s. Approvals UL USA CSA Canada EZU Czech. Republic PTB Germany GL Germany LRS Great Britain Legend: Standard design approved: identification plates bear the approval marks if it is mandatory Submitted for approval 4.18 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com M i co niat nt ure ro ls Approximate dimensions Mini contactors & overload relays 00.00 Inches 00.00 [Millimeters] Mini contactors AC & DC Operated - B6, BC6, B7, BC7 1.83 2.07 46.5 52.5 1.87 1.32 47.5 0.18 1.71 4.5 43.5 4 33.5 1.97 2.26 57.5 50.0 1.65 1.00 1.77 42.0 25.4 45.0 1.38 1.57 0.18 40.0 4.5 35.0 1.77 45.0 Mini contactor with overload relay B6, B7 & T7DU 2.07 52.5 1.83 1.38 .. 1.77 35.0 .. 45.0 46.5 1.87 0.18 47.5 0.36 4.5 9.1 1.97 1.00 50.0 25.4 1.65 42.0 1.85 4.13 47.0 1.26 32.0 105.0 0.16 0.25 4.0 2.20 1.77 6.5 56.0 45.0 E16DU with B/BC6, B/BC7 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com B7/ T7DU 4.19 1SXU000023C0202 Approximate dimensions Mechanically interlocked contactors, control relays Auxiliary contact blocks re tu ls a i in ro M ont C 00.00 Inches 00.00 [Millimeters] Mechanically interlocked - AC & DC Operated VB6M, VBC6M, VB7M, VBC7M 1.83 4 46.5 3.80 1.71 43.5 96.5 3.54 1.32 90.0 33.5 1.65 2.26 57.5 42.0 1.77 1.97 1.00 25.4 50.0 45.0 0.18 0.18 4.5 4.5 Mini control relays AC & DC Operated - K6, KC6 1.83 2.07 46.5 52.5 1.87 1.32 47.5 0.18 1.71 4.5 43.5 33.5 1.97 2.26 57.5 50.0 1.65 1.00 1.77 42.0 25.4 45.0 1.38 1.57 0.18 40.0 1.77 4.5 Mini contactor with side mounted auxiliary contact block B6, B7 & CA6 35.0 45.0 1.83 46.5 1.71 43.5 1.32 33.5 2.26 1.65 57.5 42.0 1.77 45.0 1.00 25.4 0.18 4.5 Mini contactor with front mounted auxiliary contact block B6, B7 & CA6 1.71 43.5 1.02 26 A1 2.36 2.79 71 CAF6 1.10 28 A2 60 4.20 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com