Click on Series name for product info on aimtec.com Series AM1SS-Z 1 Watt | DC-DC Converter FEATURES: * * * * * * * * RoHS Compliant 4 Pin Sip Package Low Ripple And Noise High Efficiency up to 81% Operating Temperature -40oC to +85oC Input / Output Isolation 1000 and 3000VDC Pin Compatible with Multiple Manufacturers Continuous Short Circuit Protection Models Single output Model AM1SS-0505SZ AM1SS-0512SZ AM1SS-0515SZ AM1SS-1205SZ AM1SS-1212SZ AM1SS-1215SZ AM1SS-2405SZ AM1SS-2412SZ AM1SS-2415SZ Input Voltage (V) Output Voltage (V) Output Current Max (mA) Isolation (VDC) 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 21.6-26.4 21.6-26.4 21.6-26.4 5 12 15 5 12 15 5 12 15 200 83.3 66.6 200 83.3 66.6 200 83.3 66.6 1000 1000 1000 1000 1000 1000 1000 1000 1000 Input Current Full Load | No Load (mA) 267 267 173 110 107 111 54 56 51 Max Capacitive Load (F) Efficiency (%) 100 100 100 100 100 100 100 100 100 75 75 73 76 78 75 77 75 81 55 52 50 20 23 23 15 15 12 AM1SS-0505SH30Z 4.5-5.5 5 200 3000 267 55 100 75 AM1SS-0512SH30Z 4.5-5.5 12 83.3 3000 267 52 100 75 AM1SS-0515SH30Z 4.5-5.5 15 67 3000 173 50 100 73 AM1SS-1205SH30Z 10.8-13.2 5 200 3000 110 20 100 76 AM1SS-1212SH30Z 10.8-13.2 12 83.3 3000 107 23 100 78 AM1SS-1215SH30Z 10.8-13.2 15 66.6 3000 111 23 100 75 AM1SS-2405SH30Z 21.6-26.4 5 200 3000 54 15 100 77 AM1SS-2412SH30Z 21.6-26.4 12 83.3 3000 56 15 100 75 AM1SS-2415SH30Z 21.6-26.4 15 66.6 3000 51 12 100 81 NOTE: All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal 5 12 24 Filter Turn on Transient process time Start up time Absolute Maximum Rating Peak Input Voltage time Input reflected Ripple current Typical Maximum 4.5-5.5 10.8-13.2 21.6-26.4 Capacitor VDC 25 with 12H 200 0-7 0-15 0-28 100 20 Conditions Typical 5 Vin 12 Vin 24 Vin Units ms ms VDC ms mA p-p Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance 60sec Rated Units 1000 and 3000 VDC MOhm pF Maximum Units > 1000 10 Output Specifications Parameters Voltage accuracy Short Circuit protection www.aimtec.com F 051e R12.D Conditions Typical 3 % Continuous Tel: +1 514 620 2722 1 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1SS-Z 1 Watt | DC-DC Converter Output Specifications (continued) Parameters Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Capacitive load Rising time Conditions Typical Maximum Units Auto-Recovery 1.2 10 0.02 100 For 1% change of Vin Load 20 - 100% At 20MHz Bandwidth % of Vin % %/oC mV p-p F ms 100 50 General Specifications Parameters Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load Full Load without Derating 80 Maximum Units 100 KHz oC oC o C -40to +85 -40 to +125 Free air convection 95 Non-conductive black plastic UL94-VO 1.5 0.46 x 0.24 x 0.40 inches 11.68 x 6.00 x 10.15 mm >1 121 000 hrs(MIL-HDBK -217F, Ground Benign, t=+25oC) % g Safety Specifications Standards Safety IEC 60950-1 (Designed to meet) Pin Out SpecificationsDimensions Pin 1 2 3 4 11.68 (0.46) Single 6.00 (0.24) - V Input +V Input - V Output +V Output PRINTED FACE 10.15 (0.40) 9.65 (0.38) 0.50 (0.02) 3.05 (0.12) 2.54 (0.10) 0.50 (0.02) 1.25 (0.05) 0.30 (0.10) 6.00 (0.24) 0.50 (0.02) www.aimtec.com F 051e R12.D Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1SS-Z 1 Watt | DC-DC Converter Typical Efficiency Example Charts Eff % AM1SS-0512SZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 20% 40% 60% 80% 100% Loading % Eff % AM1SS-1205SZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 20% 40% 60% 80% 100% Loading % www.aimtec.com F 051e R12.D Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1SS-Z 1 Watt | DC-DC Converter Eff % AM1SS-2412SZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 20% 40% 60% 80% 100% Loading % NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.D Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only