DC READ CHARACTERISTICS
Over Operating Range. (See Above)
SYMBOL PARAMETER TEST CONDITIONS MIN MAX UNITS
VIL Input Low Voltage (Note 3) –0.1 0.8 V
VIH Input High Voltage (Note 3) 2.0 VCC + 0.3 V
VOL Output Low Voltage IOL = 16 mA 0.4 V
VOH Output High Voltage IOH = –4 mA 2.4 V
VCC Active Current VCC = 5.5V, f = 0 MHz Comm'l 30 mA
ICC1 (CMOS) (Note 1), Output Not Loaded Industrial 35 mA
Add 2mA/MHz for AC Operation Military 35 mA
VCC Active Current VCC = 5.5V, f = 0 MHz Comm'l 40 mA
ICC2 (TTL) (Note 2), Output Not Loaded Industrial 50 mA
Add 2mA/MHz for AC Operation Military 50 mA
ILI Input Leakage
Current VIN = 5.5V or Gnd –10 10 µA
ILO Output Leakage
Current VOUT = 5.5 V or Gnd –10 10 µA
WS57C191C/291C
2-8
OPERATING RANGE
RANGE TEMPERATURE VCC
Commercial 0°C to +70°C +5V ± 10%
Industrial –40°C to +85°C +5V ± 10%
Military –55°C to +125°C +5V ± 10%
ABSOLUTE MAXIMUM RATINGS*
Storage Temperature............................–65° to + 150°C
Voltage on any Pin with
Respect to Ground ....................................–0.6V to +7V
VPP with Respect to Ground...................–0.6V to + 14V
ESD Protection..................................................>2000V
NOTES: 1. CMOS inputs: GND ± 0.3V or VCC ±0.3V.
2. TTL inputs: VIL
≤0.8V, VIH ≥2.0V.
3. These are absolute voltages with respect to device ground pin and include all overshoots due to system and/or tester noise.
Do not attempt to test these values without suitable equipment.
*NOTICE:
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to the device.
This is a stress rating only and functional operation of
the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute
maximum rating conditions for extended periods of
time may affect device reliability.
PINS CS1/ CS2 CS3 VCC OUTPUTS
MODE VPP
Read VIL VIH VIH VCC DOUT
Output Disable VIH X X VCC High Z
Output Disable X VIL X VCC High Z
Program VPP X X VCC DIN
Program Verify VIL VIH VIH VCC DOUT
Output Disable X X VIL VCC High Z
MODE SELECTION