The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. NEW Subminiature Coaxial Switch 1.6 mm High, DC to 6 GHz MS-156NB Series Overview Developed for inspection of high frequency circuits used in portable terminals.Verification of the circuit performance is accomplished by simply inserting the external plug in the board mounted receptacle.This action re-directs the circuit from normal condition to the plug side. Removing the plug restores circuit to its normal condition. Space-saving design Low profile -1.6 mm protrusion above the board. Lightweight -0.025 g. total weight. Features 1. Low insertion loss 0.1 dB typical at 6 GHz (not mated with the plug). 2. Space-saving design 2.7 mm x 2.7 mm occupied board space. MS-156NB Several types of plugs 3. Low profile 1.6 mm protrusion above the board. 4. Lightweight 0.025 g. total weight (without vacuum cap). 5. Durability 100 mating/unmating cycles, with corresponding plug. 6. Performs over a wide frequency range Applicable frequencies range over a wide band, from DC to 6 GHz. Several types of SMA conversion adapters 7. Board placement with automatic equipment Packaged on tape-and-reel. Also available with a vacuum pick-up cap over each switch. 8. RoHS compliant All components and materials comply with the requirements of the EU Directive 2002/95/EC. Applications Portable terminals, ETC, notebook computers (Bluetooth), wireless LAN, POS terminals, GPS terminals, PDA, and any small devices requiring verification of antenna/circuit performance. Adapter for plug inspection 2006.9 1 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. Product Specifications Not mated with the plug Mated (MS-156-HRMJ-3) -40c to +85c -40c to +85c Operating temperature range Rated power Frequency range 2W 2W DC to 6GHz DC to 6GHz 0.1 dB max. (DC to 3.0GHz) Insertion loss 0.5 dB max. (DC to 3.0GHz) 0.15 dB max. (3.0GHz to 6.0GHz) 1.2 dB max. (3.0GHz to 6.0GHz) 20 dB max. (DC to 2.0GHz) 15 dB max. (2.0GHz to 4.0GHz) 13 dB max. (4.0GHz to 6.0GHz) Isolation V.S.W.R 1.2 max. (DC to 2.5GHz) 1.4 max. (DC to 3.0GHz) 1.3 max. (2.5GHz to 6.0GHz) 1.8 max. (3.0GHz to 6.0GHz) Item Specification Conditions 1. Contact resistance 100 mo max. 100 mA max. 2. Insulation resistance 1000 Mo min. 100 V DC 3. Withstanding voltage No flashover or insulation breakdown 100 V AC / 1 minute Frequency:10 to 55 Hz, single amplitude of 4. Vibration No electrical discontinuity of 1 s or more 5. Shock 0.75 mm, 2 hours in each of the 3 axis. Acceleration of 490 m/s2, 6 ms duration, sine halfwave waveform, 3 cycles in each of the 3 axis Contact resistance: 100 mo max. 6. Thermal shock Insulation resistance: 10 Mo min. 7. Durability (mating/un-mating, with corresponding plug) Contact resistance: 100 mo max. Temperature: -55c / +5c to +35c / +85c /+5c to +35c Time: 30 / 2 to 3 / 30 / 2 to 3 (Minutes) 100 cycles 100 cycles Materials Part Material Finish Remarks Shell Phosphor bronze Gold plated --------------------------- Insulator 9T Nylon --------------------------- UL94V-0 Common terminal Beryllium copper Selective gold plated (Nickel barrier) --------------------------- Antenna terminal Phosphor bronze Selective gold plated (Nickel barrier) --------------------------- BCircuit diagram Not mated with the plug(N.C) G G Mated with the plug(N.O) G G A A B C B C G G G G Plug 2 MS-156NB Plug MS-156NB The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. BTypical Data NORMALLY CLOSED(N.C)~(Not mated with the plug) 0.0 INSERTION LOSS 0.1 0.2 V.S.W.R. Insertion Loss [dB] [dB] 0.3 1.3 1.2 V.S.W.R. 1.1 DC 2.0 4.0 1.0 6.0 [GHz] OPEN(N.O)~(Mated with the plug) [dB] INSERTION LOSS 0.5 1.0 1.5 1.8 V.S.W.R. V.S.W.R. Insertion Loss [dB] 0.0 1.6 1.4 1.2 DC 2.0 4.0 1.0 6.0 [GHz] 4.0 6.0 [GHz] ISOLATION [dB] 10 ISOLATION Isolation [dB] 15 20 25 30 35 40 45 DC 2.0 3 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. Receptacle Without vacuum pick-up cap Center of mating plug 0.4 A terminal 2.7 1.4 2.7 (0.05) 0.4 Part Number CL No. Packaging MS-156NB 358-0206-8 2,000 pieces/reel MS-156NB(01) 358-0206-8-01 100 pieces/bag 1.6 0.6 O2 P RoHS YES * Lead coplanarity within 0.1mm With vacuum pick-up cap 5 .7 2 1.15 O2 Part Number CL No. Packaging RoHS MS-156NB(02) 358-0206-8-02 1,500 pieces/reel YES Note:Vacuum pick-up cap flat can be oriented in any direction. Orientation will not affect placement of the switch on the board. BPCB mounting pattern and metal mask dimensions * Request drawing of the specific part for exact dimensions and tolerances. * Specified dimensions must be followed to assure correct board placement and performance. Metal mask dimensions PCB mounting pattern 0.1 to 0.12 thick 3 1.4 0.55 2-2.65 1.05 0.55 0.55 This area must be free of conductive traces and resist field. 4 2-1.4 C terminal Center of mating plug 1.25 0.3 (2.9) 2-1.4 2-2.65 Center of mating plug 0.3 A terminal 1.05 1.25 0.55 (3.4) 0.55 3 1.4 0.55 C terminal The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. BPrecautions 1. This product is intended to be used for circuit inspection only. Consult us if any other application is considered. 2. Cross-hatched area shown on the PCB mounting pattern must be free of any conducive traces. Placing conductive traces in this area may affect performance and will void product warranties. When the bottom surface of the product (i.e., the shaded area of the specified land dimensions diagram on the previous page) has been processed with a susbtrate copper trace and resist processing, Hirose Electric will not be able to warrant the product. 3. Do not use hand soldering for mounting of MS-156NB. Doing so could result in solder and flux wicking to the contact areas. 4. Exercise caution as not to allow any debris to enter the board mounted MS-156NB when cutting PCB. Recommended Mounting of MS-156NB coaxial switch on the PCB during the manufacturing process MS-156NB To avoid contamination when cutting-off, do not place PCB bridge close to the mounted MS-156NB. 5. Do not use the washing process. 6. Please refrain from using the product in environments specifically affected by excessive vibration, shock, dust, high humidity, gases, very high temperatures and very low temperatures such as outdoor equipment. It might cause degradation or destruction of the product.Even if it endures during a short time, long time quarification is not quaranteed. 7. For use of this product, be sure to put contact area of plug on position P(P4 full view) perpendicularly. 8. Plugs can be roughly classified to two types. - For mass production line automatic check (Press down type) - For manual check (With retentive lock) : Unable to be used at production line. 9. When automatic inspections are to be performed during the manufacturing operations, request the MS156 plug connector manual for examples of implementation. 5 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. BPackaging Specifications Reel dimensions MS-156NB (Without vacuum cap) 2,000 pieces/reel 2 4 1.75 .5 O1 4 12.4 2.2 O80 O180 12 5.5 3 O1 Unreeling direction MS-156NB(02) (With vacuum cap) Reel dimensions 1,500 pieces/reel O1 .5 4 2 1.75 4 12.4 O1 O80 O180 5.5 12 3 2.6 Unreeling direction BRecommended Nozzle Dimensions Without vacuum pick-up cap With vacuum pick-up cap O2.6 min O0.5~1.0 O0.5~1.0 O4 O1max. O2.5 min. * Depending on the placement equipment, the use of a special nozzle might be required. 6 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. BRecommended Temperature Profile Temperature (c) 10 sec.max. 240 Using Typical Solder Paste 200 160 150 100 50 q Maximum temperature : 240c w Peak temperature : 220c to 235c e Peak temperature time : 10 sec. max. r 200c min. : 50 sec. max. t 150c to 160c : 40 sec. min. Metal mask thickness Reflow cycles : 0.1 to 0.12 mm : 2 cycles 0 40 sec.min. Temperature (c) Time (sec.) 50 sec.max. 10 sec.max. 250 230 200 180 Using Lead-free Solder paste q Maximum temperature : 250c 150 w Peak temperature : 240c to 250c e Peak temperature time : 10 sec. max. r 230c min. : 30 sec. max. t 150c to 180c : 60 sec. to 90 sec. 100 50 Metal mask thickness Reflow cycles : 0.1 to 0.12 mm : 2 cycles 0 60 sec. to 90 sec. 30 sec.max. Time (sec.) * Max. temperature 260c for 10 sec. max. for heat gun or heat plate. 7 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. Plugs Press down, right angle 1 20.9 2.9 O6 O4 M8 4C 11.15 O3.2 Part Number CL No. Durability RoHS MS-156-C(LP)-1 358-0173-0 10,000 Times YES Applicable cable: 1.5D-HQEW, 1.5D-QEW (Fujikura Ltd.) Simplified lock, right angle 1.6 O0.5 M8 O7.9 O5.48 O4 4C 1 25.25 8.25 3 10 O3.2 Part Number CL No. Durability RoHS MS-156-C(LP)-2 358-0174-3 500 Times YES Applicable cable: 1.5D-HQEW, 1.5D-QEW (Fujikura Ltd.) SMA Conversion Adapters Simplified lock, straight, short 1/4-36UNS-2A 24.4 8 O8.5 5.2 11.3 O0.5 O5.48 O4.27 1.6 Part Number CL No. Durability RoHS MS-156-HRMJ-2 358-0170-2 500 Times YES Simplified lock, straight, long 32.9 1.6 19.8 8 5.2 O8 .5 O0.5 O5.48 O4.3 12 1/4-36UNS-2A 8 Part Number CL No. Durability RoHS MS-156-HRMJ-5 358-0177-1 500 Times YES The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. Press down, with flange, short 28.13 18.63 1 2-O2.6 14 O3.4 O5 8.12 8 O20 1/4-36UNS-2A Part Number CL No. Durability RoHS MS-156-HRMJ-3 358-0171-5 10,000 Times YES Press down, with flange, long 33.01 8 1 23.51 2-O2.6 14 O5 O3.4 13 O20 1/4-36UNS-2A Press down, with flange (Increased self alignment) Part Number CL No. Durability RoHS MS-156-HRMJ-14 358-0198-1 10,000 Times YES 28.13 18.63 1 8 2-O2.6 14 O5.9 O4.3 8.12 O20 1/4-36UNS-2A Part Number CL No. Durability RoHS MS-156-HRMJ-6 358-0181-9 10,000 Times YES Floating 31.06 20.7 2.5 2-O2.6 15 1.45 1/4-36UNS-2A O24 O3.4 20 O10 O5 4.27 Part Number CL No. Durability RoHS MS-156-HRMJ-9 358-0180-6 10,000 Times YES 9 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. Floating (Self-Pressing) 38.6 28.24 13 2.5 2-O2.6 O3.8 20 O10.3 O5.4 11.75 1/4-36UNS-2A O2 4 1.45 Part Number CL No. Durability RoHS MS-156-HRMJ-10 358-0194-0 10,000 Times YES Floating (Self-Pressing) 39.85 12 2-O2.6 2.5 29.49 O4.3 20 O5.9 O10.3 11.75 O24 3.75 1/4-36UNS-2A Part Number CL No. Durability RoHS MS-156-HRMJ-12 358-0196-6 10,000 Times YES Adapter for plug inspection 16.05 3 6.3 8.3 O2 O6 O9 0.75 1/4-36UNS-2A Part Number CL No. Durability RoHS MS-156R-HRMJ-1 358-0188-8 500 Times YES Adapter for plug inspection 41.9 13.21 2.54 14.3 O2 O5.45 0.75 O2 10 2 5/8-24NEF-2A Part Number CL No. Durability RoHS MS-156R-NJ-1 358-0176-9 500 Times YES