HCX...A6 / HCX(M)...D6 - Series
Fully signal conditioned pressure transducer
January 1998/026
Aubinger Weg 27, 82178 Puchheim, Germany
Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33
http://www.sensortechnics.com
OUTLINE DRAWING
HCX(M)...6V
P1: High pressure port for
5 mbar and 10 mbar devices
P2: High pressure port for
all other devices.
Mass: 14 g All dimensions in mm
ORDERING INFORMA TION Part Number
Package version
Side facing ports
HCXPM005D6V
HCXM010D6V
HCXPM010D6V
HCXM020D6V
HCXM050D6V
HCXM100D6V
HCXM350D6V
HCX001D6V
HCX002D6V
HCX005D6V
HCX001A6V
HCX002A6V
T op facing ports
HCXPM005D6H
HCXM010D6H
HCXPM010D6H
HCXM020D6H
HCXM050D6H
HCXM100D6H
HCXM350D6H
HCX001D6H
HCX002D6H
HCX005D6H
HCX001A6H
HCX002A6H
Pressure range
Differential / gage devices
0 to ±5 mbar
0 to 10 mbar
0 to ±10 mbar
0 to 20 mbar
0 to 50 mbar
0 to 100 mbar
0 to 350 mbar
0 to 1 bar
0 to 2 bar
0 to 5 bar
Absolute devices
0 to 1 bar
0 to 2 bar
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein,
neither does it convey any license under its patent rights nor the rights of others.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
Non-linearity - the maximum deviation of measured output at constant temperature, from "Best Straight Line" through three points (offset pressure, full scale pressure and 1/2 full
scale pressure).
Change after one year or 1 million pressure cycles.
Thermal effects tested and guaranteed from 0°C to 50°C relative to 25°C. All specifications shown are relative to 25°C.
Span is the algebraic difference between the output at full scale pressure and offset.
Offset adjustment possible to lower values only . Do not trim for nominal value minus 150 mV .
Span adjustment possible to lower pressure range (higher gain). Do not trim for more than 15% of full scale pressure
Specification Notes
1.
2.
3.
4.
5.
6.