Rev.11.02.11_65
NFS40 Series
3 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Notes
1 Natural convection cooled, 40 W maximum.
2 Peak output current lasting less than 30 seconds with duty cycle less than 10%.
During peak loading, outputs may go outside of total regulation limits. Peak
total power must not exceed 60 W.
3 Forced air, 20 CFM at 1 atmosphere, 50 W maximum.
4 Figure is peak-to-peak. Output noise is measured across a 50 MHz bandwidth
using a 12 inch twisted pair, terminated with a 47 µF capacitor.
5 Total regulation is dened as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings. Also, 0.25<I(A)/
I(B)<5.0 to maintain stated regulation. This does not apply to the NFS40-7628J
power supply as it has regulated auxiliary outputs.
6 A minimum load of 0.5 A is required on the +5 V output to obtain full current
from the negative output.
7 The NFS40 offers the possibility of power sharing between outputs. Consult
factory for details.
8 Derating curve is application specic for ambient temperatures >50 °C, for
optimum reliability no part of the heatsink should exceed 110 oC and no
semiconductor case temperature should exceed 115 oC.
9 A 4 W minimum load is recommended to achieve the design MTBF.
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, sweep at 1 octave/minute, 5 minute dwell at four major
resonances.
12 The NFS40-7628J has separately linear regulated +12 V and -12 V outputs. The
loading conditions in Notes 5 and 6 do not apply.
13 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
14 The ‘J’ sufx indicates that these parts are Pb-free (RoHS 6/6) compliant.
15 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.Emerson.com/EmbeddedPower to nd a suitable
alternative.
Ordering Information
Output
Voltage
Output Currents Ripple (4) Total
Regulation (5)
Model Numbers (13, 14, F)
Max (1) Peak (2) Fan (3)
+5.1 V (A) 3 A 7 A 5 A 50 mV ± 2.0% NFS40-7608J (5,6)
+12 V (B) 2 A 3 A 2 A 120 mV ± 5.0%
–12 V (C) 0.35 A 1 A 0.5 A 120 mV ± 5.0%
+5.1 V (A) 4 A 7 A 5 A 50 mV ± 2.0% NFS40-7628J (12)
+12 V (B) 0.35 A 1 A 0.5 A 120 mV ± 5.0%
-12 V (C) 0.35 A 1 A 0.5 A 120 mV + 5.0%
+5.1 V (A) 3 A 7 A 5 A 50 mV ± 2.0% NFS40-7607J (5,6)
+12 V (B) 2 A 3 A 2 A 120 mV ± 5.0%
-5.0 V (C) 0.35 A 1 A 0.5 A 50 mV ± 5.0%
+5.1 V (A) 3 A 7 A 5 A 50 mV ± 2.0% NFS40-7610J (5,6)
+15 V (B) 2 A 2.5 A 2 A 150 mV ± 10.0%/-3.0%
–15 V (C) 0.35 A 1 A 0.5 A 150 mV ± 5.0%
3.3 V 6 A 12 A 8 A 100 mV ± 2.0% NFS40-76S3J
+5.1 V 6 A 12 A 8 A 100 mV ± 2.0% NFS40-7605J
+12.0 V 3.3 A 5 A 4 A 120 mV ± 2.0% NFS40-7612J
+15.0 V 2.6 A 4 A 3.3 A 150 mV ± 2.0% NFS40-7615J
+24.0 V 1.6 A 2.5 A 2 A 240 mV ± 2.0% NFS40-7624J
Pin Connections
J1 -7608J, -7628J -7607J -7610J SINGLES
Pin 1 AC Live AC Live AC Live AC Line
Pin 2 AC Neutral AC Neutral AC Neutral AC Neutral
J2
Pin 1 +12 V +12 V +15 V +Vout
Pin 2 +5.1 V +5.1 V +5.1 V +Vout
Pin 3 +5.1 V +5.1 V +5.1 V +Vout
Pin 4 Return Return Return Return
Pin 5 Return Return Return Return
Pin 6 -12 V -5 V -15 V Return
P1(c)
Pin 1 Safety Ground
DERATING CURVE
Output Power (Watts)
0C 10C 20C 30C 40C 50C 60C 70C
20W
40W
50W
20 CFM FORCED AIR COOLING
25W
NATURAL
CONVECTION
COOLING