Embedded Power for Business-Critical Continuity Rev.11.02.11_65 NFS40 Series 1 of 4 NFS40 Series SIngle and triple output Total Power: 40 - 50 W Input Voltage: 85 - 264 Vac 120 - 370 Vdc # of Outputs: Single, triple Electrical Specifications Special Features * 5.0 x 3.0 x 1.2 inch package (1U applications) * Industry standard package * Overvoltage and short circuit protection * 40 W with free air convection * 50 W with 20 CFM forced air * EN55022, EN55011 conducted noise level B * UL, VDE and CSA safety approvals * Available RoHS compliant * 2 year warranty Input Voltage adjustability: +5 V output on triples Vout on singles 5.0% 5.0% Line regulation: LL to HL, FL Main output Auxiliary outputs 0.2% 1.0% Load regulation: FL to NL Transient response: Main output Auxiliary outputs 2.0% 5.0% +5 V (1.5 - 3 A) 120 mV max. dev. 500 s recovery Temperature coefficient: All outputs 0.02%/C Overvoltage protection: +5 V output S3.15 A, 250 Vac In live and neutral Output power limit: Short circuit protection: Primary power limited 90 W input power limit Single outputs Multiple outputs Continuous Short term Universal input 85 - 264 Vac 120 - 370 Vdc Output Input voltage range: Safety * VDE0805/EN60950/ * IEC950/IEC1010 * File No. 10401-3336-0044 * License No. 2559 * UL60950-1 File No. E13002 * CSA C22.2 No. 950 * File No. LR41062C Input frequency range: Max. input surge current: Safety ground leakage current: 47-440 Hz 132 Vac, cold start 264 Vac, cold star 12 A max. 24 A max. 110 Vac, 60 Hz 230 Vac, 50 Hz 0.13 mA, max. 0.32 mA, max. Embedded Power for Business-Critical Continuity Rev.11.02.11_65 NFS40 Series 2 of 4 Specifications All specifications are typical at nominal input, full load at 25 C unless otherwise stated EMC Charateristics (11, 12) Conducted emissions: Radiated emissions: ESD air: ESD contact: Surge: Fast transients: Radiated immunity: Conducted immunity: EN55022, FCC part 15 EN55022 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-2, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Level B Level A Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 2 Perf. criteria 2 110 Vac, 40 W 230 Vac, 40 W 14 ms 110 ms General Specifications Hold-up time: Efficiency: Isolation voltage: Switching frequency: 70% typical Input/output Input/chassis 3000 Vac 1500 Vac Variable Approvals and standards: (see VDE0805, EN60950, IEC950, IEC1010, Notes 9, 13) UL1950, CSA C22.2 No. 950 Weight: 280 g (9.88 oz) MTBF demonstrated: MIL-HDBK-217E 170,000 hours Environmental Specifications Thermal performance: Operating 0 C to +70 C (See notes 8, 10) Non-operating -40 C to +85 C 50 C ambient temp., convection cooled 40 W Forced air cooling 50 W @ 20 CFM +50 C to +70 C ambient Derate linearly to 50% load Peak (60 seconds) 60W Relative humidity: Non-condensing 5 to 80% RH Altitude: Operating 10,000 feet max. Non-operating 40,000 feet max. 5-500 Hz 2.4 G rms peak Vibration (See Note 11): Embedded Power for Business-Critical Continuity Ordering Information Output Voltage Output Currents Ripple (4) Total Regulation (5) Fan (3) Max (1) Peak (2) +5.1 V (A) 3A 7A 5A 50 mV 2.0% +12 V (B) 2A 3A 2A 120 mV 5.0% -12 V (C) 0.35 A 1A 0.5 A 120 mV 5.0% +5.1 V (A) 4A 7A 5A 50 mV 2.0% +12 V (B) 0.35 A 1A 0.5 A 120 mV 5.0% -12 V (C) 0.35 A 1A 0.5 A 120 mV + 5.0% +5.1 V (A) 3A 7A 5A 50 mV 2.0% +12 V (B) 2A 3A 2A 120 mV 5.0% -5.0 V (C) 0.35 A 1A 0.5 A 50 mV 5.0% +5.1 V (A) 3A 7A 5A 50 mV 2.0% +15 V (B) 2A 2.5 A 2A 150 mV 10.0%/-3.0% -15 V (C) 0.35 A 1A 0.5 A 150 mV 5.0% 3.3 V 6A 12 A 8A 100 mV 2.0% NFS40-76S3J +5.1 V 6A 12 A 8A 100 mV 2.0% NFS40-7605J +12.0 V 3.3 A 5A 4A 120 mV 2.0% NFS40-7612J +15.0 V 2.6 A 4A 3.3 A 150 mV 2.0% NFS40-7615J +24.0 V 1.6 A 2.5 A 2A 240 mV 2.0% NFS40-7624J Notes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Model Numbers (13, 14, F) Natural convection cooled, 40 W maximum. Peak output current lasting less than 30 seconds with duty cycle less than 10%. During peak loading, outputs may go outside of total regulation limits. Peak total power must not exceed 60 W. Forced air, 20 CFM at 1 atmosphere, 50 W maximum. Figure is peak-to-peak. Output noise is measured across a 50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 F capacitor. Total regulation is defined as the static output regulation at 25 C, including initial tolerance, line voltage within stated limits, load currents within stated limits, and output voltages adjusted to their factory settings. Also, 0.2550 C, for optimum reliability no part of the heatsink should exceed 110 oC and no semiconductor case temperature should exceed 115 oC. A 4 W minimum load is recommended to achieve the design MTBF. Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. Three orthogonal axes, sweep at 1 octave/minute, 5 minute dwell at four major resonances. The NFS40-7628J has separately linear regulated +12 V and -12 V outputs. The loading conditions in Notes 5 and 6 do not apply. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.Emerson.com/EmbeddedPower to find a suitable alternative. Rev.11.02.11_65 NFS40 Series 3 of 4 NFS40-7608J (5,6) NFS40-7628J (12) NFS40-7607J (5,6) NFS40-7610J (5,6) Pin Connections J1 -7608J, -7628J -7607J -7610J SINGLES Pin 1 AC Live AC Live AC Live AC Line Pin 2 AC Neutral AC Neutral AC Neutral AC Neutral Pin 1 +12 V +12 V +15 V +Vout Pin 2 +5.1 V +5.1 V +5.1 V +Vout Pin 3 +5.1 V +5.1 V +5.1 V +Vout Pin 4 Return Return Return Return Pin 5 Return Return Return Return Pin 6 -12 V -5 V -15 V Return J2 P1(c) Pin 1 Safety Ground DERATING CURVE Output Power (Watts) 50W 20 CFM FORCED AIR COOLING 40W NATURAL CONVECTION COOLING 0C 10C 20C 30C 40C 25W 20W 50C 60C 70C Embedded Power for Business-Critical Continuity Mechanical Drawing 0.156 (3.96) Dia. (4 Places) NON-METALLIC STAND-OFF (SEE NOTE A) J1 3.00 (76.2) Americas 5.00 (127.00) C5 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 MAXIMUM COMPONENT HEIGHT 1.2 inches Europe (UK) Q1 1 ~ N ~ L F1 2.550 (64.8) T1 F 3.15A, H 250VAC 0.22 (5.59) 0.22 (5.59) 4.55 (115.8) ALL DIMENSIONS IN INCHES (mm) Mechanical Notes Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) J2 P1 (SEE NOTE C) Rev.11.02.11_65 NFS40 Series 4 of 4 A In order to meet safety requirements, a non-metallic stand-off is mandatory for one hole as specified in the mechanical drawing above. B The ground pad of the mounting hole near P1 allows system grounding through a metal stand-off. C To improve conducted noise, the ground pad of the mounting hole near the output connector should be connected with the ground pad of the mounting hole near P1. Use metal stand-offs attached to a common metal chassis. This connection also significantly attenuates common mode noise. D A standard enclosure kit is available for mounting which contains all screws, connectors and necessary mounting hardware. Order part number NFS40CJ. 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.Emerson.com/EmbeddedPower techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2011 Emerson Electric Co.