MCC MURX0510 THRU MURX0560 omponents 21201 Itasca Street Chatsworth !"# $ % !"# Features * * * * * 0.5 Amp Super Fast Recovery Rectifier 100 to 600 Volts For Surface Mount Application Low Leakage Low Forward Voltage Drop Extremely Low Thermal Resistance Super Fast Recovery Time For High Efficiency Maximum Ratings * * * SOD-123 Operating Temperature: -40 to +150 Storage Temperature: -40 to +150 Maximum Thermal Resistance: 200/W Junction to Ambient Maximum DC Blocking Voltage MCC Part Number Device Marking Maximum Recurrent Peak Reverse Voltage MURX0510 U1 100V 70V 100V MURX0520 U2 200V 140V 200V MURX0530 U3 300V 210V 300V MURX0540 U4 400V 280V 400V MURX0550 U5 500V 350V 500V MURX0560 U6 600V 420V 600V Maximum RMS Voltage A B C E H D DIM Electrical Characteristics @ 25 Unless Otherwise Specified Average Forward Current IF(AV) 0.5 A TL = 115 Peak Forward Surge Current IFSM 8.0A 8.3ms, half sine Maximum Instantaneous Forward Voltage VF 1.35V IFM =0.5A; TA = 25 Maximum DC Reverse Current At Rated DC Blocking Voltage IR 5.0A TA = 25 Maximum Reverse Recovery Time Trr 75ns IF=0.5A, IR=1.0A, Irr=0.25A Typical Junction Capacitance CJ 10pF Measured at 1.0MHz, VR=4.0V J G A B C D E G H J DIMENSIONS INCHES MM MIN MAX MIN MAX .140 .152 3.55 3.85 .100 .112 2.55 2.85 .055 .071 1.40 1.80 ----.053 ----1.35 .012 .031 0.30 .78 .006 ----0.15 --------.01 ----.25 ----.006 ----.15 SUGGESTED SOLDER PAD LAYOUT 0.093" 0.048" *Pulse Test: Pulse Width 300sec, Duty Cycle 2% www.mccsemi.com 0.036" NOTE MCC MURX0510 thru MURX0560 Figure 1 Typical Forward Characteristics 2.0 Figure 2 Forward Derating Curve 1.0 .6 .6 .4 .5 .2 25C Amps .4 .1 .06 .3 Amps .04 .2 .02 .01 .1 Single Phase, Half Wave 60Hz Resistive or Inductive Load .006 0 .004 50 75 100 125 175 Average Forward Rectified Current - Amperes versus Ambient Temperature - C .6 .4 .8 1.0 1.2 1.4 Volts Instantaneous Forward Current - Amperes versus Instantaneous Forward Voltage - Volts Figure 3 Junction Capacitance 10 6 TJ=25C 4 2 pF 150 C .002 .001 0 1 .6 .4 .2 .1 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 400 Junction Capacitance - pF versus Reverse Voltage - Volts www.mccsemi.com 1000 MCC MURX0510 thru MURX0560 Figure 4 Typical Reverse Characteristics Figure 5 Peak Forward Surge Current 100 9.0 60 40 7.5 TA=150C 20 6.0 10 4.5 6 Amps 4 3.0 1.5 2 TA=100C 0 Amps 1 1 4 2 6 .6 8 10 20 40 60 80 100 Cycles .4 Peak Forward Surge Current - Amperes versus Number Of Cycles At 60Hz - Cycles .2 TA=25C .1 .06 .04 .02 .01 2 60 4 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts Figure 6 Reverse Recovery Time Characteristic And Test Circuit Diagram 50 10 trr +0.5A 0 Pulse Generator Note 2 25Vdc 1 Notes: 1. Rise Time = 7ns max. Input impedance = 1 megohm, 22pF 2. Rise Time = 10ns max. Source impedance = 50 ohms 3. Resistors are non-inductive Oscilloscope Note 1 -0.25 1.0 1cm Set Time Base for 20/100ns/cm www.mccsemi.com