MURX0510
THRU
MURX0560
0.5 Amp Super Fast
Recovery Rectifier
100 to 600 Volts
Features
For Surface Mount Application
Low Leakage
Low Forward Voltage Drop
Extremely Low Thermal Resistance
Super Fast Recovery Time For High Efficiency
Maximum Ratings
Operating Temperature: -40к to +150к
Storage Temperature: -40к to +150 к
Maximum Thermal Resistance: 200 к/W Junction to Ambient
MCC
Part Number
Device
Marking
Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MURX0510
U1 100V 70V 100V
MURX0520
U2 200V 140V 200V
MURX0530
U3 300V 210V 300V
MURX0540
U4 400V 280V 400V
MURX0550
U5 500V 350V 500V
MURX0560
U6 600V 420V 600V
Electrical Characteristics @ 25к Unless Otherwise Specified
Average Forward
Current IF(AV) 0.5 A
TL = 115к
Peak Forward Surge
Current IFSM 8.0A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage VF 1.35V IFM =0.5A;
TA = 25 к
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR 5.0µA
TA = 25 к
Maximum Reverse
Recovery Time Trr 75ns IF=0.5A, IR=1.0A,
Irr=0.25A
Typical Junction
Capacitance CJ 10pF Measured at
1.0MHz, VR=4.0V
*Pulse Test: Pulse Width 300µsec, Duty Cycle 2%
omponents
21201 Itasca Street Chatsworth

 !"#
$% !"#
MCC
www.mccsemi.com
SOD-123
0.036”
0.093”
0.048”
SUGGESTED SOLDER
PAD LAYOUT
DIMENSIONS
INCHES MM DIM MIN MAX MIN MAX NOTE
A .140 .152 3.55 3.85
B .100 .112 2.55 2.85
C .055 .071 1.40 1.80
D ----- .053 ----- 1.35
E .012 .031 0.30 .78
G .006 ----- 0.15 -----
H ----- .01 ----- .25
J ----- .006 ----- .15
A
B
E
C
J
D
H
G
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
Figure 2
Forward Derating Curve
0
175
50
75
100
125
0
.1
.2
.3
Amps
°C
150
.4
.
5
.6
Junction Capacitance - pF versus
Reverse Voltage - Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
.4
.6
2.0
1.0
Amps
.4
.6
.8
1.0
1.2
1.4
.001
.002
.004
.006
.01
.02
.04
.06
.1
.2
25°C
Volts
Figure 3
Junction Capacitance
.1
.2
1
.4
2
10
20
40
4
100
200
.1
.2
.6
1
2
10
pF
Volts
6
4
.4
400
1000
TJ=25°C
Single Phase, Half Wave
60Hz Resistive or Inductive Load
www.mccsemi.com
MCC
MURX0510 thru MURX0560
trr
+0.5A
0
-0.25
1
.0
1cm
Set Time Base for 20/100ns/cm
25Vdc
1
50
10
Oscilloscope
Note 1
Pulse
Generator
Note 2
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive
Figure 6
Reverse Recovery Time Characteristic And Test Circuit Diagram
1
100
4
0
1.5
3.0
4.5
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10
20
60
80
4
0
6
.0
7.5
9.0
Figure 4
Typical Reverse Characteristics
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Volts
4
6
20
10
µAmps
2120
460
80
100
.01
.02
.
04
.06
.1
.2
.4
.6
1
2
TA=25°C
40
6
0
1
00
1
40
TA=100°C
TA=150°C
www.mccsemi.com
MCC
MURX0510 thru MURX0560