www.clare.com
2
LCA182
R01.1
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Current (Continuous)
AC/DC Configuration - IL- - 120 mA
DC Configuration - IL- - 200 mA
Peak Load Current 10ms ILPK - - 350 mA
On-Resistance
AC/DC Configuration IL=120mA RON - 23 35 Ω
DC Configuration IL=200mA RON -7 10Ω
Off-State Leakage Current VL=350V ILEAK -- 1µA
Switching Speeds
Turn-On IF=1mA, VL=10V TON -- 3ms
Turn-Off IF=1mA, VL=10V TOFF -3ms
Output Capacitance 50V; f=1MHz COUT - 25 - pF
Input Characteristics @ 25°C
Input Control Current1IL=120mA IF0.25 - - mA
Input Dropout Current - IF0.05 - - mA
Input Voltage Drop IF=1mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics @ 25°C
Input to Output Capacitance - CI/O -3 -pF
1It is recommended that the input control current be increased to 1mA in high temperature (over+55oC) operation.
Absolute Maximum Ratings (@ 25˚ C)
Electrical Characteristics
Parameter Ratings Units
Input Power Dissipation 1501mW
Input Control Current 50 mA
Peak (10ms) 1 A
Reverse Input Voltage 5 V
Blocking Voltage 350 V
Total Power Dissipation 8002mW
Isolation Voltage
Input to Output 3750 VRMS
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
Soldering Temperature
DIP Package +260 °C
Surface Mount Package -+220 °C
(10 Seconds Max.)
1Derate Linearly 1.33 mw/˚C
2Derate Linearly 6.67 mw/˚C