3 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protection: Short circuit / Overload / Over voltage / Over temperature
Built-in cooling Fan ON-OFF control
Built-in remote ON-OFF control
2 color LED loading indicator
Low cost, high reliability
2 years warranty
■ Features :
PB-230-12
MODEL
BOOST CHARGE VOLTAGE
FLOAT CHARGE VOLTAGE
OUTPUT CURRENT
BATTERY TYPE
RECOMMENDED BATTERY
CAPACITY(AMP HOURS)
(Note 5)
OUTPUT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OVERLOAD
OVER VOLTAGE
PROTECTION
AC CURRENT (Typ.)
14.4V
13.6V
16A
Open & Sealed Lead Acid
50 ~ 160Ah
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
81.5%
3A/115VAC 1.5A/230VAC
COLD START 50A
<3.5mA / 240VAC
90 ~ 110% rated output current
16 ~ 18V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Automatically derate charge current until zero
UL1012(for PB-230-xxAD1 only), TUV EN60950-1 approved
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
-20 ~ +50 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃℃)0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
MTBF 244.5Khrs min. MIL-HDBK-217F (25 )℃
190*96*49mm(L*W*H)
DIMENSIONOTHERS
NOTE
PACKING 1.21Kg; 12pcs/15.5Kg/1.29CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
FUNCTION
REMOTE CONTROL (CN105)
FAN CONTROL
TEMPERATURE SENSE
Open: Normal work Short: Stop Charging
RTH3 50 Fan ON, 45 Fan OFF (Typ.)≧℃ ≦℃
By NTC
PB-230-24 PB-230-48
28.8V 57.6V
27.2V 54.4V
8A 4A
24 ~ 80Ah 12 ~ 40Ah
85.5% 86%
31 ~ 35V 59 ~ 64V
File Name:PB-230-SPEC 2015-03-12
ORDER NO. OUTPUT CONNECTOR SAFETY
PB-230-xx (standard model) 4pin power din TUV / CE
PB-230-xxAD1 (optional model)
PB-230-xx xx=12,24,48 ; =Blank, AD1
Anderson connector UL
POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load
TUV
Rheinland
Product Safety
TUV
Rheinland
Product Safety
:
geprUfre
Sicherheit
geprUfre
Sicherheit
( for PB-230-xxAD1 only)
CONNECTOR
PLUG
CABLE See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
230W Single Output Battery Charger PB-230 series
SPECIFICATION
EMC IMMUNITY
EMC EMISSION