Technical Data 4376
Effective May 2016
HV supercapacitors
Cylindrical cells
www.eaton.com/elx
Ratings
Capacitance 1.0 F to 100 F
Maximum working voltage 2.7 V
Surge voltage 3.0 V
Capacitance tolerance -10% to +30%
Operating temperature range -40 °C to +65 °C
Extended temperature range -40 °C to +85 °C (with linear voltage derating to 2.3 V @ 85 °C)
Specifications
Capacitance1 (F)
Part Number
Maximum
Initial ESR1
(Ω)
Nominal
Leakage
Current2
(µA) Stored Energy3
(mWh) Peak
Power4 (W)
Pulse
Current5
(A) Continuous
Current6 (A)
Typical
Thermal
Resistance7,
Rth (°C/W)
Short
Circuit
Current8
(A)
1 HV0810-2R7105-R 0.200 10 1.0 9.1 1.1 0.8 120 14
3 HV0820-2R7305-R 0.080 15 3.0 23 3.3 1.6 76 34
5 HV1020-2R7505-R 0.040 20 5.1 46 5.6 2.3 73 68
6 HV0830-2R7605-R 0.040 20 6.1 46 6.5 2.8 47 68
10 HV1030-2R7106-R 0.034 23 10 54 10 3.3 40 79
15 HV1325-2R7156-R 0.030 23 15 61 14 3.1 53 90
25 HV1625-2R7256-R 0.027 45 25 68 20 3.4 47 100
35 HV1245-2R7356-R 0.020 51 35 91 28 5.8 22 135**
35 HV1635-2R7356-R 0.024 51 35 76 26 4.0 39 113
60 HV1840-2R7606-R 0.018 110 61 101 39 5.7 26 150**
100 HV1860-2R7107-R 0.012 260 101 152 61 11 10 225**
** Repeated short circuit current will permanently damage the leads and cause an open failure.
Performance
Parameter Capacitance change
(% of initial value) ESR
(% of maximum initial value)
Life (1000 hours @ +65 °C @ 2.7 Vdc) ≤ 30% ≤ 200%
Storage (3 years, uncharged, <+35 °C) ≤ 5% ≤ 110%
Cycle Life9 (500,000 cycles) ≤ 30% ≤ 200%
1. Capacitance and Equivalent Series Resistance (ESR) measured according to IEC62391-1 at +20 °C, with current in milliamps (mA) = 8*C*V
2. Leakage current at 20 °C after 72 hour charge and hold
3. Energy (mWh) = ½*C*V2 *1000
3600
4. Peak Power (W) = V2
4*ESR
5. Pulse Current in Amps (A), 1 second discharge from rated voltage to half rated voltage = ½*C*V
(1+ESR*C)
6. Continuous current with a 15 °C temperature rise. Continuous current (A) =
7. Thermal resistance (Rth) cell body temperature to ambient in open air in degrees C per Watt (°C/W)
8. Short circuit current is for safety information only. Do not use as operating current.
9. Cycling between rated voltage and half voltage, 3 seconds rest at +20 °C
Safety and Certifications
Regulatory UL810a, RoHS
Warnings Do not overvoltage, do not reverse polarity
Shipping UN3499, <0.3Wh, Non-hazardous goods