Born to drive machines
» High programming functionality
» Built-in safety
» Omron Quality with a capital ‘Q’
MX2 inverter
Harmonised motor and
machine control
The MX2 is specifically designed to drive
machines. It has been developed to
harmonise advanced motor and machine
control. Thanks to its advanced design and
algorithms the MX2 provides smooth control
down to zero speed, plus precise operation
for fast cyclic operations and torque control
capability in open loop. The MX2 also gives
you comprehensive functionality for
machine control such as positioning, speed
synchronisation and logic programming.
The MX2 is fully integrated within the
Omron smart automation platform. The
MX2 is the child of a true leader in machine
automation.
Special motors
One parameter
auto-tuning
Torque control
in open loop
200%
starting torque
•
Permanentmagnetmotors
•
Highspeedmotorsupto1000Hz
•
JustbyenteringthekWratingof
themotortheMX2givesyou
smoothandsafeoperation
•
Idealforlowtomediumtorque
applications
•
Canreplaceafluxvectororservo
driveinsuitablesystems
•
Nearstand-stilloperation(0.5Hz)
•
Smoothcontrolofhighinertialoads
•
Controloffastcyclicloads
Positioning
Integrated in the
Omron Smart
Automation
Logic
programming
Safety inside
•
Upto8pre-setpositionswith
“Homing”
•
Speedsynchronisation
•
CX-Driveprogrammingtoolconnected
viaintegratedUSBportonMX2.
•
ModbusRS485built-in
•
OptionunitsforEtherCAT,Profibus,
DeviceNet,ML-IIandmore…
•
Flowchartprogramming
•
Intuitive–upto5tasksin
parallel
•
ConformstosafetynormISO-13849
CAT3performancelevelPLd
•
2Safetyinputs
•
Externaldevicemonitoring(EDM)
MOTOR CONTROL
MACHINE CONTROL
24 VDC
220 VAC
100% Control... ...0% risk!
Torque master
TheMX2delivers200%starting
torquenearstand-still(0.5Hz)and
canoperateintorquecontrolin
openloopmode.Thisallowsthe
MX2tobeusedinapplications
whereclosedloopACvectordrives
werepreviouslyused.
Safety embedded;
ISO 13849-1, cat 3
Dualcontactorsattheoutputofthe
inverterarenolongerrequired.
Directconnectiontoasafety
controllerensurescomplianceto
ISO13849-1,cat3.
Easy network integration
Built-inRS485Modbus
communicationsandthepossibility
forintegrationinstandardindustrial
networks,suchasDnet,Profibus,
CANopen,CompoNet,ML-IIor
EtherCatmakestheMX2
exceptionallyeasytointegrate.
EDM monitoring output
AnExternalDeviceMonitoring
(EDM)outputconfirmsthesafety
statusoftheinverter,savingyou
thecostandwiringofexternal
devicestocarryoutthesame
function.
External 24 VDC for
continuous operation
Withnoadditionalhardware,a24
VDC
connectiontotheMX2
ensurestheCPUisalwaysin
control,evenifthemaininputis
removed.Thisfeatureisvitalin
providingacontrolledstopin
emergencysituationsandin
keepingthenetwork
communicationsoperating.
Direct integration into the
safety circuit
MX2inverterscanfiteasilyintothe
safetycircuit.Thesafetyinputscan
belinkedfromoneinverterto
anotherwithoutadditionalsafety
relays.
Highstartingtorqueandtorquecontrolcapabilityin
openloopmodegiveyoufullcontrolofyourmachine
dynamicsandperformance.Optionsforallofthe
majorfieldbussystemsanda24VDCexternalsupply
keepsyouinfullcontrolofyourmachineoperation.
SafetyisembeddedintheMX2,accordingtoISO
13849-1,Cat3,withtwosafetyinputsandanExternal
DeviceMonitoring(EDM)output.
Noexternalcontactorsonthemotorsidearerequired,
meaningsimplerwiringfortheuser.
Safety redundancy input Dual safety input chain
EDM output
Speed
Torque response
Torque reference
Torque
EDM safety output chain
Position and run! Program and play!
Positioning functionality
Speciallydevelopedapplicationfunctionalityenables
theMX2tosolvesimplepositioningtaskswithoutthe
needforanexternalcontroller.Upto8positions,plus
home,canbeselectedbytheuser,andfurthermore,
theMX2canbeswitchedbetweenspeedandposition
mode.
Free to program
Intuitiveanduserfriendlyflowchartprogramming
IntegratedinCX-Drive
Upto1000linesinaprogram
5taskscanruninparallel
Speed synchronisation
Withnoexternalhardwarerequired,andviastandard
parametersettings,speedsynchronisationcanbe
achieved.TheMX2willactasaspeedfollowertoan
externalpulsegenerator/encodersignalupto32KHz.
TheMX2isadriveandpositioncontrollerinone,
idealformodularmachineswheremoderate
positionalaccuracyisrequired.Speed
synchronisationisalsopossible,withnoadditional
programmingrequired.
TheMX2givesyouthepowertocreatesmart
solutionsusingPLCfunctionality,asstandard.Viaan
intuitiveflowchartprogrammingtool,youcancreate
programswithupto1000linesofcodeandwith5
tasksrunninginparallel.
Speed
X00
X01
1
Multi-function Compact Inverter
3G3MX2
With Machine Automation Mentality
Current vector Control.
High Starting torque: 200% at 0.5 Hz.
Double rating VT 120%/1 min and CT 150% /1 min.
Speed range up to 1,000 Hz.
Positioning functionality.
Safety embedded compliant with ISO 13849-1: 2006 (PLd)
(double input circuit and external device monitor)
Modbus communications.
PC Configuration tool: CX-Drive.
Interpreting Model Numbers
001
002
004
007
015
022
030
0.1 kW
0.2 kW
0.4 kW
0.75 kW
1.5 kW
2.2 kW
3.0 kW
037
040
055
075
110
150
3.7 kW
4.0 kW
5.5 kW
7.5 kW
11 kW
15 kW
Voltage class
B
2
1-phase 200 VAC (200-V class)
3-phase 200 VAC (200-V class)
4 3-phase 400 VAC (400-V class)
3G3MX2
Max. applicable motor capacity (CT)
IP Rating
A
D
IP20
IP54 Include Class 2 EMC Filter IP54 Enclosure Type
E
EC
Book Type
Customised Version
3G3MX2
2
Ordering Information
International Standards
The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus,
UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
Contact your OMRON representative for further details and applicable conditions for these standards.
3G3MX2 Inverter Models
For option, refer to 16 page.
Support Software
*1. Multi licenses are available for the CX-One (3, 10, 30, or 50 licenses).
*2. When purchasing the DVD format, verify the computer model and DVD drive specifications before purchasing.
Rated voltage Enclosure ratings Max. applicable motor capacity IP20 Model IP54 Model
CT: Heavy load VT: Light load
3-phase 200 VAC IP20
0.1kW 0.2 kW 3G3MX2-A2001 3G3MX2-D2001-E/EC
0.2 kW 0.4 kW 3G3MX2-A2002 3G3MX2-D2002-E/EC
0.4 kW 0.75 kW 3G3MX2-A2004 3G3MX2-D2004-E/EC
0.75 kW 1.1 kW 3G3MX2-A2007 3G3MX2-D2007-E/EC
1.5 kW 2.2 kW 3G3MX2-A2015 3G3MX2-D2015-EC
2.2 kW 3.0 kW 3G3MX2-A2022 3G3MX2-D2022-EC
3.7 kW 5.5 kW 3G3MX2-A2037 3G3MX2-D2037-EC
5.5 kW 7.5 kW 3G3MX2-A2055 3G3MX2-D2055-EC
7.5 kW 11 kW 3G3MX2-A2075 3G3MX2-D2075-EC
11 kW 15 kW 3G3MX2-A2110 3G3MX2-D2110-EC
15 kW 18.5 kW 3G3MX2-A2150 3G3MX2-D2150-EC
3-phase 400 VAC IP20
0.4 kW 0.75 kW 3G3MX2-A4004 3G3MX2-D4004-EC
0.75 kW 1.5 kW 3G3MX2-A4007 3G3MX2-D4007-EC
1.5 kW 2.2 kW 3G3MX2-A4015 3G3MX2-D4015-EC
2.2 kW 3.0 kW 3G3MX2-A4022 3G3MX2-D4022-EC
3.0 kW 4.0 kW 3G3MX2-A4030 3G3MX2-D4030-EC
4.0 kW 5.5 kW 3G3MX2-A4040 3G3MX2-D4040-EC
5.5 kW 7.5 kW 3G3MX2-A4055 3G3MX2-D4055-EC
7.5 kW 11 kW 3G3MX2-A4075 3G3MX2-D4075-EC
11 kW 15 kW 3G3MX2-A4110 3G3MX2-D4110-EC
15 kW 18.5 kW 3G3MX2-A4150 3G3MX2-D4150-EC
1-phase 200 VAC IP20
0.1 kW 0.2 kW 3G3MX2-AB001 3G3MX2-DB001-E/EC
0.2 kW 0.4 kW 3G3MX2-AB002 3G3MX2-DB002-E/EC
0.4 kW 0.55 kW 3G3MX2-AB004 3G3MX2-DB004-E/EC
0.75 kW 1.1 kW 3G3MX2-AB007 3G3MX2-DB007-E/EC
1.5 kW 2.2 kW 3G3MX2-AB015 3G3MX2-DB015-EC
2.2 kW 3.0 kW 3G3MX2-AB022 3G3MX2-DB022-EC
Product name Specifications Model Standards
Number of
licenses Media
FA Integrated Tool
Package
CX-OneVer. 4.@
The CX-One is a package that integrates the Support
Software for OMRON PLCs and components.
CX-One runs on the following OS.
Windows 2000 (Service Pack 4 or higher), XP, Vista or 7
Note: Except for 64-bit version
CX-One Ver.4.@ includes CX-Programmer Ver.9.@.
For details, refer to the CX-One catalog (Cat. No. R134).
1 license
*1
CD CXONE-AL01C-V4
---
DVD
*2CXONE-AL01D-V4
FA Integrated Tool
Package
CX-One Lite Ver. 4.@
The CX-One Lite is a subset of the complete CX-One
package that provides only the Support Software required
for micro PLC applications.
CX-One Lite runs on the following OS.
Windows 2000 (Service Pack 4 or higher), XP, Vista or 7
Note: Except for 64-bit version
CX-One Ver.4.@ includes Micro PLC Edition
CX-Programmer Ver.9.@. .
1 license CD CXONE-LT01C-V4
CX-Drive can still be ordered individually in the following model numbers.
CX-Drive Ver.1.@
Application software to set and control data for Inverters and
Servos.
OS: Windows 2000 (Service Pack 3a or higher), XP, or Vista
1 license CD WS02-DRVC1 ---
3G3MX2
3
Standard Specification List
3-phase 200 V Class
*The BRD usage is 10%.
3-phase 400 V Class
*The BRD usage is 10%.
Function name 3-phase 200 V
Model name (3G3MX2-@)2001 2002 2004 2007 2015 2022 2037 2055 2075 2110 2150
Applicable
motor
capacity
kW CT 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
VT 0.2 0.4 0.75 1.1 2.2 3.0 5.5 7.5 11 15 18.5
HP CT 1/8 1/4 1/2 1 2 3 5 7 1/2 10 15 20
VT 1/4 1/2 1 1 1/2 3 4 7 1/2 10 15 20 25
Rated
output
capacity
[kVA]
200 V CT 0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
VT 0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
240 V CT 0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
VT 0.4 0.7 1.4 2.4 3.9 4.9 8.1 12.4 16.6 23.2 28.6
Rated input voltage 3-phase 200 V - 15% to 240 V + 10%, 50/60 ± 5%
Rated output voltage 3-phase 200 to 240 V (The output cannot exceed the incoming voltage).
Rated output
current [A]
CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
VT 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Short-time deceleration
braking torque (%)
(Discharge Resistor not
connected)
50 50 50 50 50 20 20 20 20 10 10
Braking
Resistor
circuit *
Regenerative
braking
Built-in Braking Resistor circuit (separate Discharge Resistor)
Min. connectable
resistance [Ω]100 100 100 50 50 35 35 20 17 17 10
Weight [kg] 1.0 1.0 1.1 1.2 1.6 1.8 2.0 3.3 3.4 5.1 7.4
Dimensions (width
×
height)
[mm]
68
×
128 108
×
128 140
×
128 140
×
260 180
×
296
220
×
350
Dimensions (depth) [mm] 109 122.5 145.5 170.5 170.5 155 175
Function name 3-phase 400 V
Model name (3G3MX2-@)4004 4007 4015 4022 4030 4040 4055 4075 4110 4150
Applicable
motor
capacity
kW CT 0.4 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15
VT 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
HP CT 1/2 1 2 3 4 5 7 1/2 10 15 20
VT 123457 1/210152025
Rated
output
capacity
[kVA]
380 V CT 1.1 2.2 3.1 3.6 4.7 6.0 9.7 11.8 15.7 20.4
VT 1.3 2.6 3.5 4.5 5.7 7.3 11.5 15.1 20.4 25.0
480 V CT 1.4 2.8 3.9 4.5 5.9 7.6 12.3 14.9 19.9 25.7
VT 1.7 3.4 4.4 5.7 7.3 9.2 14.5 19.1 25.7 31.5
Rated input voltage 3-phase 380 V - 15% to 480 V + 10%, 50/60 ± 5%
Rated output voltage 3-phase 380 to 480 V (The output cannot exceed the incoming voltage).
Rated output
current [A]
CT 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
VT 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
Short-time deceleration
braking torque (%)
(Discharge Resistor not
connected)
50 50 50 20 20 20 20 20 10 10
Braking
Resistor
circuit *
Regenerative
braking
Built-in Braking Resistor circuit (separate Discharge Resistor)
Min. connectable
resistance [Ω]180 180 180 100 100 100 70 70 70 35
Weight [kg] 1.5 1.6 1.8 1.9 1.9 2.1 3.5 3.5 4.7 5.2
Dimensions (width
×
height)
[mm]
108
×
128 140
×
128 140
×
260 180
×
296
Dimensions (depth) [mm] 143.5 170.5 170.5 155 175
3G3MX2
4
1-phase 200 V Class
*The BRD usage is 10%.
Function name 1-phase 200 V
Model name (3G3MX2-@)B001 B002 B004 B007 B015 B022
Applicable
motor
capacity
kW CT 0.1 0.2 0.4 0.75 1.5 2.2
VT 0.2 0.4 0.55 1.1 2.2 3.0
HP CT 1/81/41/2123
VT 1/4 1/2 3/4 1 1/2 3 4
Rated
output
capacity
[kVA]
200 V CT 0.2 0.5 1.0 1.7 2.7 3.8
VT 0.4 0.6 1.2 2.0 3.3 4.1
240 V CT 0.3 0.6 1.2 2.0 3.3 4.5
VT 0.4 0.7 1.4 2.4 3.9 4.9
Rated input voltage 1-phase 200 V - 15% to 240 V + 10%, 50/60 Hz ± 5%
Rated output voltage 3-phase 200 to 240 V (The output cannot exceed the incoming voltage).
Rated output
current [A]
CT 1.0 1.6 3.0 5.0 8.0 11.0
VT 1.2 1.9 3.5 6.0 9.6 12.0
Short-time deceleration
braking torque (%)
(Discharge Resistor not
connected)
50 50 50 50 50 20
Braking
Resistor
circuit *
Regenerative
braking
Built-in Braking Resistor circuit (separate Discharge Resistor)
Min. connectable
resistance [Ω]100 100 100 50 50 35
Weight [kg] 1.0 1.0 1.1 1.6 1.8 1.8
Dimensions (width
×
height)
[mm]
68
×
128 108
×
128
Dimensions (depth) [mm] 109 122.5 170.5
3G3MX2
5
Common Specifications
Note: 1.
The applicable motor is a 3-phase standard motor. For using any other type, be sure that the rated current does not exceed that of the Inverter.
2. Output voltage decreases according to the level of the power supply voltage.
3. The braking torque at the time of capacitor feedback is an average deceleration torque at the shortest deceleration (when it stops from
50 Hz). It is not a continuous regeneration torque. Also, the average deceleration torque varies depending on the motor loss. The value
is reduced in operation over 50 Hz.
*1. Protection method complies with JEM 1030.
*2. To operate the motor at over 50/60 Hz, contact the motor manufacturer to find out the maximum allowable speed of revolution.
*3. For the stable control of the motor, the output frequency may exceed the maximum frequency set in A004 (A204) by 2 Hz max.
Function name Specifications
Enclosure ratings *1Open type (IP20)
Control
Control method Phase-to-phase sinusoidal modulation PWM
Output frequency range *20.10 to 400 Hz (or 1,000 Hz in the high-frequency mode; restrictions apply)
Frequency precision *3Digital command: ±0.01% of the max. frequency, Analog command: ±0.2% of the max. frequency
(25°C±10°C)
Frequency setting resolution Digital setting: 0.01 Hz, Analog setting: One-thousandth of the maximum frequency
Voltage/Frequency
characteristics
V/f characteristics (constant/reduced torque)
Sensorless vector control, V/f control with speed feedback
Overload current rating Heavy load rating (CT): 150%/60 s
Light load rating (VT): 120%/60 s
Instantaneous overcurrent
protection 200% of the value of heavy load rating (CT)
Acceleration/Deceleration time 0.01 to 3600 s (linear/curve selection), acceleration/deceleration 2 setting available
Carrier frequency adjustment
range 2 to 15 kHz (with derating)
Starting torque 200%/0.5 Hz (sensorless vector control)
External DC injection braking Starts at a frequency lower than that in deceleration via the STOP command, at a value set lower than
that during operation, or via an external input. (Level and time settable).
Protective functions
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground fault overcurrent
at power-on status, rush current prevention circuit, overload limit, incoming overvoltage, external trip,
memory error, CPU error, USP error, communication error, overvoltage suppression during
deceleration, protection upon momentary power outage, emergency cutoff, etc.
Input signal
Frequency settings
Digital Operator
External analog input signal: Variable resistance/0 to 10 VDC/4 to 20 mA, Modbus communication
(Modbus-RTU)
RUN/STOP command Digital Operator
External digital input signal (3-wire input supported), Modbus communication (Modbus-RTU)
Multi-function input 7 points (Selectable from 59 functions)
Analog input 2 points (Voltage FV terminal: 10 bits/0 to 10 V, Current FI terminal: 10 bits/4 to 20 mA)
Pulse input 1 point (RP terminal: 32 kHz max., 5 to 24 VDC)
Output signal
Multi-function output 2 points (P1/EDM, P2; selectable from 43 functions)
Relay output 1 point (1c contact: MC, MA, MB; selectable from 43 functions)
Analog output
(Frequency monitor) 1 point (AM terminal: Voltage 10 bits/0 to 10 V) (Frequency, current selectable)
Pulse output 1 point (MP terminal: 32 kHz max., 0 to 10 V)
Communications
RS-422 RJ45 connector (for Digital Operator)
RS-485 Control circuit terminal block, Modbus communication (Modbus-RTU)
USB USB1.1, mini-B connector
Other functions
AVR function, V/f characteristics switching, upper/lower limit, 16-step speeds, starting frequency
adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/
bias adjustment, S shape acceleration/deceleration, electronic thermal characteristics, level adjustment,
restart function, torque boost function, fault monitor, soft lock function, frequency conversion display,
USP function, motor 2 control function, UP/DWN, overcurrent suppression function, etc.
General specifications
Ambient temperature -10 to 50°C (However, derating is required).
Ambient storage temperature -20°C to 65°C (short-time temperature during transport)
Humidity 20% to 90% RH (with no condensation)
Vibration 5.9 m/s2 (0.6G), 10 to 55 Hz
Location At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Options DC reactor, AC reactor, radio noise filter, input noise filter, output noise filter, regenerative braking unit,
Braking Resistor, EMC noise filter, etc.
3G3MX2
6
Terminal Block Specifications
Names of Parts Inside the Terminal Block Cover
Name Description
Modbus-RTU Termination resistor
selector switch
Use this Terminal Resistor selector switch for RS-485 terminals on the control circuit terminal block. When this switch is turned
ON, the internal 200 Ω Resistor is connected.
Safety function selector switch Turn this switch ON when using the safety function. Turn OFF the power before turning this switch ON/OFF. For details, refer to
User’s Manual (I570).
EDM function selector switch Turn this switch ON when using the EDM output of the safety function. Turn OFF the power before turning this switch ON/
OFF.For details, refer to User’s Manual (I570).
USB connector Use this mini-B USB connector to connect a PC.
Even when the Inverter is being operated by a PC, etc., via USB connection, it can still be operated using the Digital Operator.
Connector for Digital Operator Use this connector to connect the Digital Operator.
Connector for optional board Use this connector to mount the optional board. (The optional board will be released soon.)
Control circuit terminal blocks A
and B These terminal blocks are used to connect various digital/analog input and output signals for inverter control, etc.
Multi-function contact terminal block
Use this SPDT contact terminal block for relay outputs.
Main circuit terminal block Use this terminal block to connect an output to the motor and Braking Resistor, etc.
Also, use this terminal block to connect the inverter to the main power supply.
CHARGE indicator
(Charge indicator LED)
This LED indicator is lit if the DC voltage of the main circuit (between terminals P/+2 and N/-) remains approx. 45 V or above
after the power has been cut off. Before wiring, etc. confirm that the Charge LED indicator is turned OFF.
Modbus-RTU Termination resistor selector switch Safety function selector switch
Connector for optional board
Multi-function contact terminal block
CHARGE indicator
Main circuit terminal block
OFF
(Factory default) ON
USB connector (mini-B)
Connector for Digital Operator (RJ45)
EDM function selector switch
Control circuit terminal block A
Control circuit terminal block B
Disable
(Factory default) Enable
P1 terminal
(Factory default)
EDM output
3G3MX2
7
Main Circuit Terminals Specifications
[Main Circuit Terminal Block]
3G3MX2-A2001 to A2037
3G3MX2-A4004 to A4040
3G3MX2-AB001 to AB022
[Main Circuit Terminal Block]
3G3MX2-A2001 to A2037
3G3MX2-A4004 to A4040
3G3MX2-AB001 to AB022
From power supply
(Connect to L1 and N for 1-phase)
To motors
From power supply To motors
Terminal
symbol Terminal name Description
R/L1
Main power supply input terminal Connect the input AC power supply.In the case of a 1-phase 200 V power supply, connect to
L1 and N.
S/L2
T/L3
U/T1
Inverter output terminal Connect a 3-phase motor.V/T2
W/T3
+1 DC reactor connection terminal Remove the shorting bar between terminals +1 and P/+2, and connect the optional DC reactor.
P/+2
P/+2 Braking Resistor connection
terminal Connect optional braking resistors. (If a braking torque is required)
RB
P/+2 Regenerative braking unit
connection terminal
Connect optional regenerative braking units. (When braking torque is required or the built-in
braking circuit is not sufficient)
N/
GGround terminal
This is a ground terminal. Connect this terminal to the ground. Provide Class D grounding for
200 V class models, and class C grounding for 400 V class models.
On 200 V class models of 3.7 kW or below and 400 V class models of 4.0 kW or below, the
ground terminal is located on the cooling fin.
3G3MX2
8
Control Circuit Terminals Specifications
Terminal
symbol Terminal name Description Specifications
Analog
Power
supply
SC Input signal common
This is a common terminal used by the internal
power supply, digital input and analog input/
output terminals.
FS Frequency reference
power supply 10 VDC power supply for the FV terminal. Allowable max. current: 7 mA
Frequency
setting
input
FV
Frequency reference
input terminal (analog
voltage input)
Use this terminal if the frequency reference is
provided by 0 to 10 VDC voltage input.
Input impedance
Approx. 10 kΩ
Allowable input voltage range
0.3 to +12 VDC
FI
Frequency reference
terminal (analog
current input)
Use this terminal if the frequency reference is
provided by 4 to 20 mA current input.
Input impedance
100 Ω
Allowable input range
0 to 24 mA
Sensor
input S5/TH
External thermistor
input (also used as
multi-function input
terminal)
Connect an external thermistor between the SCs,
to trip the Inverter when a temperature error
occurs. (The inverter will trip when the input from
thermistor is approx. 3 kΩ or higher.) Since this
input is also used as the multi-function input
terminal, setting of C005 is required. For details,
refer to User’s Manual (I570).
PTC type
Output AM Multi-function analog
output (voltage)
Specified signals can be output using voltage
signals of 0 to 10 VDC. AM
Digital
Power
supply
SC Input signal common
This is a common terminal used by the internal
power supply, digital input and analog input/
output terminals.
P24 Power supply terminal
for input signal
24 VDC power supply for contact input
signal.This is used as a common terminal if the
source logic is input.
Allowable max. current: 100 mA
PSC Power supply terminal
for input terminal
Sink logic input: Shorted with P24
Source logic input: Shorted with SC
To drive the contact input using an external power
supply, remove the shorting bar. For details, refer
to User’s Manual (I570).
Input
Contact
S7/EB
S6
S5/TH
S4/GS2
S3/GS1
S2
S1
Multi-function input
terminal
Select 7 functions from among 59, and allocate
them to terminals S1 through S7/EB. Both sink
and source logics are supported. For details, refer
to User’s Manual (I570).
Voltage between each input and PSC
ON voltage: 18 V min.
OFF voltage: 3 V max.
Allowable max. voltage: 27 VDC
Load current: 5 mA (at 24 V)
S4/GS2
S3/GS1 Safety input
Enabled when the safety function selector switch
is turned ON. For details, refer to User’s Manual
(I570).
Relay output
Communication
RS-485 Logic input
Logic common and
power supply
Shorting
bar
Pulse
output
Pulse
input
Analog input and
power supply
Communication
RS-485
Analog
output
Logic output
3G3MX2
9
Switching Method for Input Control Logics
Multi-function input terminals are set to sink logic at the factory.
To switch the input control logic to source logic, remove the shorting bar between terminals P24 and PSC on the control circuit terminal block, and
connect it between terminals PSC and SC.
Digital
Input
Pulse
RP Pulse input-A
A pulse input for frequency setting. (Take note
that the internal circuit is different from input
terminals S7/EB.)
Input pulse 32 kHz max.
Voltage between input and SC
ON voltage: 4 V min.
OFF voltage: 1 V max.
Allowable max. voltage: 27 VDC
S7/EB Pulse input-B
A pulse input for frequency setting. (Take note
that the internal circuit is different from input
terminal RP.)
Input pulse 1.8 kHz max.
ON voltage: 18 V min.
OFF voltage: 3 V max.
Allowable max. voltage: 27 VDC
Load current: 5 mA (at 24 V)
Output
Open collector
P1/EDM
P2
Multi-function output
terminal
Select 2 functions from among 43, and allocate
them to terminals P1 through P2. Both sink and
source logics are supported. For details, refer to
User’s Manual (I570).
Open collector output
Between each terminal and PC
Allowable max. voltage: 27 V
Allowable max. current: 50 mA
Voltage drop when ON: 4 V max.
P1/EDM Safety monitor
Enabled when the EDM function selector switch
is ON. For details, refer to "Safety Function" on
page 5-167.
Relay
MA
MB Relay output terminal
Select the desired functions from among 43
functions, and allocate them to these terminals.
SPDT contact.
The factory default of Relay Output (MA, MB)
Contact Selection (C036) is NC contact between
MA-MC, and NO contact between MB-MC.
Max. contact capacity
MA-MC:
250 VAC, 2 A (resistance)
0.2 A (induction)
MB-MC:
250 VAC, 1 A (resistance)
0.2 A (induction)
Contact min. capacity
100 VAC, 10mA
5 VDC, 100mA
MC Relay output common
Pulse
MP Pulse output Pulses are output.
Output pulse: 32 kHz max.
Output voltage: 10 VDC
Allowable max. current: 2 mA
Serial
communication
RS+
RSModbus port (RS-485)
RS-485 port
RS+ RS-485 differential (+) signal
RS- RS-485 differential () signal
Max. speed: 115.2 kbps
Built-in Terminal Resistor: 200 Ω
Slide switch selection
Terminal
symbol Terminal name Description Specifications
3G3MX2
10
Connection Diagram
Single-phase
3-phase
power
supply
Shorting
bar Shorting bar
Motor
ELB
MC R/L1
S/L2
T/L3
24VDC
MC
S7/EB
S5/TH
S4/GS2
S3/GS1
S2
S1
FS
FV
FI
RP
AM
MP
RS
RS+
PC
P1/EDM
P2
MB
MA
N/
SC
S6
P24P24
DC reactor
PSC
SC
If any external source-logic
output equipment or power
supply is used, refer to
"Connection to
Programmable Controllers
(PLC)" on page 2-22.
Multi-function
input
(7 contact
points)
Multi-function output
(2 terminals)
Multi-function
relay output
Braking Resistor *
*
Option
2 kΩ or more 10 VDC power
supply (7 mA Max.)
Analog voltage input
0 to 10 V (10 bits)
Analog voltage
output 0 to 10 V
(10 bits)
Class D (200 V class)
Class C (400 V class)
Analog current input
4 to 20 mA (10 bits)
Pulse input
5 to 24 VDC
(32 kHz Max.)
Pulse output
0 to 10 VDC
(32 kHz Max.)
Serial communication port
(RS-485/Modbus-RTU)
RB
P/+2
+1
W/T3
V/T2
U/T1
M
To connect the DC
reactor, remove
the shorting bar.
RB
N/
P/+2
Regenerative
Braking Unit *
P
RB
Braking Resistor *
When using a Regenerative Braking Unit
P
N
Note: 1. Connect a single-phase 200 V AC input to terminals L1 and N.
2. Factory default settings for relay output are NC contact for MA and NO contact for MB.
3G3MX2
11
Names of Parts and their Descriptions
Name Description
POWER LED Lit (green) while the Inverter is receiving power.
ALARM LED Lit (red) when the Inverter trips.
For information on how to reset the trip, refer to User’s Manual (I570).
PROGRAM LED
indicator
Lit (green) when the displayed data (set value) can be changed.
Blinks if the set value is invalid. Refer to User’s Manual (I570).
RUN (during RUN)
LED indicator
Lit (green) when the Inverter is running. (Lit when there is either a "valid RUN command" or
"inverter output." Accordingly, it is also lit when a RUN command is issued at a set frequency
of 0 Hz or while the motor is decelerating after the RUN command is turned OFF.)
Monitor LED
indicator (Hz) Lit (green) when the displayed data is frequency.
Monitor LED
indicator (A) Lit (green) when the displayed data is current.
RUN Command
enabled LED
indicator
Lit (green) when the RUN command is set to the Digital Operator.
(The RUN key on the Digital Operator is enabled.)
Display Various parameters, frequency/set value and other data are displayed (red).
RUN key Runs the Inverter. Take note that this key is enabled only when the RUN command
destination is the Digital Operator.
STOP/RESET key
This key decelerates the Inverter to a stop. (Although the STOP/RESET key is enabled even
when a RUN command is issued to a destination other than the Digital Operator (factory
default), it can be disabled by a Setting (b087).)
If the Inverter is already tripped, the trip will be reset (return from the tripping).
Mode key
Parameter is displayed: Move to the beginning of the next function group.
Data is displayed: Cancel the setting and return to the parameter display.
Individual input mode: Move the blinking digit to the left.
Regardless of the displayed screen, pressing and holding this key (for 1 second or more)
displays the data for Output Frequency Monitor (d001).
Increment key
Decrement key
These keys are used to increment/decrement a parameter or set data. Pressing and holding
each key increases the incrementing/decrementing speed.
Pressing the Increment and Decrement keys together activates the "Individual Input MODE"
where each digit can be edited independently.
Enter key
Parameter is displayed: Move to the data display.
Data is displayed: Confirm/store the setting (in the EEPROM) and return to the
parameter display.
Individual input mode: Move the blinking digit to the right.
USB connector
Use this connector (mini-B type) to connect a PC.
The Inverter can still be operated from the Digital Operator even when it is being operated
using a PC, etc., via USB communication.
RJ45 connector
Use this connector (RS-422) to connect the optional Remote Operator. Once the Remote
Operator is connected, the keys on the main unit become disabled. In this case, use b150 to
set the item to be displayed.
8.8.8.8.
Data display
RUN Command enabled
LED indicator
Operation key
USB connector
RJ45 connector
8.8.8.8.
3G3MX2
12
Dimensions (Unit: mm)
8.8.8.8.
68
56 4.5 dia.
128
118
5
D
D1
2.6
3G3MX2-AB001
3G3MX2-AB002
3G3MX2-AB004
3G3MX2-A2001
3G3MX2-A2002
3G3MX2-A2004
3G3MX2-A2007
Power supply Model W [mm] H [mm] D [mm]
D1 [mm]
1-phase
200 V
3G3MX2-AB001
3G3MX2-AB002
68 128
109 13.5
3G3MX2-AB004 122.5 27
3-phase
200 V
3G3MX2-A2001
3G3MX2-A2002 109 13.5
3G3MX2-A2004 122.5 27
3G3MX2-A2007 145.5 50
8.8.8.8.
108
96
128
118
5
D
D1
4.4
Two, 4.5 dia.
3G3MX2-AB007
3G3MX2-AB015
3G3MX2-AB022
3G3MX2-A2015
3G3MX2-A2022
3G3MX2-A4004
3G3MX2-A4007
3G3MX2-A4015
3G3MX2-A4022
3G3MX2-A4030
Power supply Model W [mm] H [mm] D [mm]
D1 [mm]
1-phase
200 V
3G3MX2-AB007
3G3MX2-AB015
3G3MX2-AB022
108 128
170.5 55
3-phase
200 V
3G3MX2-A2015
3G3MX2-A2022
3-phase
400 V
3G3MX2-A4004 143.5 28
3G3MX2-A4007
3G3MX2-A4015
3G3MX2-A4022
3G3MX2-A4030
170.5 55
3G3MX2
13
8.8.8.8.
140
Two, 4.5 dia.
128
128
118
5
170.5
55
4.4
3G3MX2-A2037
3G3MX2-A4040
Power supply Model W [mm] H [mm] D [mm]
D1 [mm]
3-phase
200 V 3G3MX2-A2037
140 128 170.5 55
3-phase
400 V 3G3MX2-A4040
8.8.8.8.
140
Two, 6 dia.
122
260
248
6
155
73.3
6
3G3MX2-A2055
3G3MX2-A2075
3G3MX2-A4055
3G3MX2-A4075
Power supply Model W [mm] H [mm] D [mm]
D1 [mm]
3-phase
200 V
3G3MX2-A2055
3G3MX2-A2075 140 260 155 73.3
3-phase
400 V
3G3MX2-A4055
3G3MX2-A4075
3G3MX2
14
8.8.8.8.
180
Two, 7 dia.
160
296
284
7
175
97
5
3G3MX2-A2110
3G3MX2-A4110
3G3MX2-A4150
Power supply Model W [mm] H [mm] D [mm]
D1 [mm]
3-phase
200 V 3G3MX2-A2110
180 296 175 97
3-phase
400 V
3G3MX2-A4110
3G3MX2-A4150
8.8.8.8.
220
Two, 7 dia.
192
350
336
7
175
84
5
3G3MX2-A2150
Power supply Model W [mm] H [mm] D [mm]
D1 [mm]
3-phase
200 V 3G3MX2-A2150 220 350 175 84
3G3MX2
15
IP54
Figure 1 Figure 2 Figure 3 Figure 4
3G3MX2-DB001-E 3G3MX2-DB001-EC 3G3MX2-D2055-EC 3G3MX2-D2110-EC
3G3MX2-DB002-E 3G3MX2-DB002-EC 3G3MX2-D2075-EC 3G3MX2-D2150-EC
3G3MX2-DB004-E 3G3MX2-DB004-EC 3G3MX2-D4055-EC 3G3MX2-D4110-EC
3G3MX2-D2001-E 3G3MX2-DB007-EC 3G3MX2-D4075-EC 3G3MX2-D4150-EC
3G3MX2-D2002-E 3G3MX2-DB015-EC
-
3G3MX2-D2004-E 3G3MX2-DB022-EC
3G3MX2-D2007-E 3G3MX2-D2001-EC
3G3MX2-D2002-EC
3G3MX2-D2004-EC
3G3MX2-D2007-EC
3G3MX2-D2015-EC
3G3MX2-D2022-EC
3G3MX2-D2037-EC
3G3MX2-D4004-EC
3G3MX2-D4007-EC
3G3MX2-D4015-EC
3G3MX2-D4022-EC
3G3MX2-D4030-EC
3G3MX2-D4040-EC
464.74
179.5
274
274
292.7
292.7
150
444
12.5
12.5
62.44
62.44
169.5
Figure 1
309.5
482.8
462.33
279.5
12.5
298.9
317.7
63.5
299.5
Figure 2
299.5
281
325
607
627.04
12.5
295
315
63
Figure 3
379
710.35
311
349
369
689.85
329.7
18.7
Figure 4
11.5
16
SYSDRIVE Option
3G3MX2 Related Options
Type
Specifications
Model
% ED Voltage
Max.
Motor
kW
Inverter
3G3MX2-A@Connectable
min.
resistance Ω
Resist ΩBraking
torque %
3-Phase 1-Phase
BRAKING RESISTORS
3%
10 sec
max.
200V
(Single-/
Three-
phase)
0.12 2001 B001
100 400 200 AX-REM00K1400-IE
0.25 2002 B002 180
0.55 2004 B004 200 180 AX-REM00K1200-IE
1.1 2007 B007 50 100
1.5 2015 B015 70 140 AX-REM00K2070-IE
2.2 2022 B022 35 90
4.0 2037 - 75 50 AX-REM00K4075-IE
5.5 2055 - 20 35 75 AX-REM00K4035-IE
7.5 2075 - 17 55
11 2110 - 35 40 AX-REM00K6035-IE
15 2150 - 10 17 55 AX-REM00K9017-IE
400V
(Three-
phase)
0.55 4004 -
180 400 200 AX-REM00K1400-IE
1.1 4007 - 200
1.5 4015 - 200 190 AX-REM00K1200-IE
2.2 4022 -
100
200 130 AX-REM00K2200-IE
3.0 4030 - 120 160 AX-REM00K2120-IE
4.0 4040 - 120
5.5 4055 -
70 75 140 AX-REM00K4075-IE
7.5 4075 - 100
11 4110 - 100 50 AX-REM00K6100-IE
15 4150 - 30 70 55 AX-REM00K9070-IE
10%
10 sec
max.
200V
(Single-/
Three-
phase)
0.12 2001 B001
100 400 200 AX-REM00K1400-IE
0.25 2002 B002 180
0.55 2004 B004 200 180 AX-REM00K1200-IE
1.1 2007 B007 50 70 200 AX-REM00K2070-IE
1.5 2015 B015 75 130 AX-REM00K4075-IE
2.2 2022 B022 35 35 180 AX-REM00K4035-IE
4.0 2037 - 35 100 AX-REM00K6035-IE
5.5 2055 - 20 20 150 AX-REM00K9020-IE
7.5 2075 - 17 17 110 AX-REM01K9017-IE
11 2110 - 17 75 AX-REM02K1017-IE
15 2150 - 10 10 95 AX-REM03K5010-IE
400V
(Three-
phase)
0.55 4004 -
180 400 200 AX-REM00K1400-IE
1.1 4007 - 200
1.5 4015 - 200 190 AX-REM00K2200-IE
2.2 4022 -
100 120 200 AX-REM00K5120-IE
3.0 4030 - 160
4.0 4040 - 100 140 AX-REM00K6100-IE
5.5 4055 -
70
70 150 AX-REM00K9070-IE
7.5 4075 - 70 110 AX-REM01K9070-IE
11 4110 - 70 75 AX-REM02K1070-IE
15 4150 - 30 35 110 AX-REM03K5035-IE
3G3MX2
17
Type
Specifications
Model
Type Voltage Inverter
3G3MX2-A@
Rated Current
(A)
EMC LINE FILTERS
Foot Mounting
[Rasmi]
200V
(Single-phase)
B001 / B002 / B004 10 AX-FIM1010-RE
B007 14 AX-FIM1014-RE
B015 / B022 24 AX-FIM1024-RE
200V
(Three-phase)
2001 / 2002 / 2004 / 2007 10 AX-FIM2010-RE
2015 / 2022 20 AX-FIM2020-RE
2037 30 AX-FIM2030-RE
2055 / 2075 60 AX-FIM2060-RE
2110 80 AX-FIM2080-RE
2150 100 AX-FIM2100-RE
400V
(Three-phase)
4004 / 4007 5 AX-FIM3005-RE
4015 / 4022 / 4030 10 AX-FIM3010-RE
4040 14 AX-FIM3014-RE
4055 / 4075 23 AX-FIM3030-RE
4110 / 4150 50 AX-FIM3050-RE
Separate
Mounting
[Schaffner]
200V
(Single-phase)
B001 / B002 / B004 10 AX-FIM1010-SE
B007 / B015 / B022 24 AX-FIM1024-SE
200V
(Three-phase)
2001 / 2002 / 2004 / 2007 10 AX-FIM2010-SE
2015 / 2022 20 AX-FIM2020-SE
2037 30 AX-FIM2030-SE
2055 / 2075 60 AX-FIM2060-SE
2110 80 AX-FIM2080-SE
2150 100 AX-FIM2100-SE
400V
(Three-phase)
4004 / 4007 5 AX-FIM3005-SE
4015 / 4022 / 4030 10 AX-FIM3010-SE
4040 14 AX-FIM3014-SE
4055 / 4075 23 AX-FIM3030-SE
4110 / 4150 50 AX-FIM3050-SE
Type
Specifications
Model
Voltage Inverter
3G3MX2-A@
INPUT AC REACTORS
200V
(Single-phase) B001 / B002 / B004 / B007 / B015 / B022 UNDER DEVELOPMENT
200V
(Three-phase)
2001 / 2002 / 2004 / 2007 AX-RAI02800080-DE
2015 / 2022 / 2037 AX-RAI00880200-DE
2055 / 2075 AX-RAI00350335-DE
2110 / 2015 AX-RAI00180670-DE
400V
(Three-phase)
4004 / 4007 / 4015 AX-RAI07700050-DE
4022 / 4030 / 4040 AX-RAI03500100-DE
4055 / 4075 AX-RAI01300170-DE
4110 / 4150 AX-RAI00740335-DE
3G3MX2
18
*Under Development
Type
Specifications
Model
Voltage Inverter
3G3MX2-A@
DC REACTORS
200V
(Single-phase)
B001 / B002 AX-RC10700032-DE
B004 AX-RC06750061-DE
B007 AX-RC03510093-DE
B015 AX-RC02510138-DE
B022 AX-RC01600223-DE
200V
(Three-phase)
2001 / 2002 AX-RC21400016-DE
2004 AX-RC10700032-DE
2007 AX-RC06750061-DE
2015 AX-RC03510093-DE
2022 AX-RC02510138-DE
2037 AX-RC01600223-DE
2055 AX-RC01110309-DE
2075 AX-RC00840437-DE
2110 AX-RC00590614-DE
2150 AX-RC00440859-DE
400V
(Three-phase)
4004 AX-RC43000020-DE
4007 AX-RC27000030-DE
4015 AX-RC14000047-DE
4022 AX-RC10100069-DE
4030 AX-RC08250093-DE*
4040 AX-RC06400116-DE
4055 AX-RC04410167-DE
4075 AX-RC03350219-DE
4110 AX-RC02330307-DE
4150 AX-RC01750430-DE
OUTPUT AC REACTORS
200V
(Single-phase)
B001 / B002 / B004 AX-RAO11500026-DE
B007 AX-RAO07600042-DE
B015 AX-RAO04100075-DE
B022 AX-RAO03000105-DE
200V
(Three-phase)
2001 / 2002 / 2004 AX-RAO11500026-DE
2007 AX-RAO07600042-DE
2015 AX-RAO04100075-DE
2022 AX-RAO03000105-DE
2037 AX-RAO01830160-DE
2055 AX-RAO01150220-DE
2075 AX-RAO00950320-DE
2110 AX-RAO00630430-DE
2150 AX-RAO00490640-DE
400V
(Three-phase)
4004 / 4007 / 4015 AX-RAO16300038-DE
4022 AX-RAO11800053-DE
4030 / 4040 AX-RAO07300080-DE
4055 AX-RAO04600110-DE
4075 AX-RAO03600160-DE
4110 AX-RAO02500220-DE
4150 AX-RAO02000320-DE
3G3MX2
19
*Available soon. Please contact OMRON for availability.
Related Manuals
Type Specifications Model
Description Diameter
RADIO
NOISE
FILTERS
For 2.2 kW motors or below 21 AX-FER2102-RE
For 15 kW motors or below 25 AX-FER2515-RE
For 45 kW motors or below 55 AX-FER5045-RE
Type Description Model
COMMUNICATON
OPTION
CompoNet option board 3G3AX-MX2-CRT-E
DeviceNet option board 3G3AX-MX2-DRT-E
EtherCat option board 3G3AX-MX2-ECT
EtherNet/P option board 3G3AX-MX2-EIP-A
Mechatrolink II option board 3G3AX-MX2-MRT-E
Profibus option board 3G3AX-MX2-PRT-E
CanOpen option board 3G3AX-MX2-CORT*
PC
CABLE
PC Communication cable
(2m, PC USB to Mini USB Connecting Cable with Ferrite) AX-CUSBM002-E
REMOTE
OPERATOR
LCD Remote operator
(5 Line LCD remote operator with copy function, cable length max. 3m.) AX-OP05-E
LED Remote operator with frequency reference volume 3G3AX-OP01
3 meters cable for connecting remote operator 3G3AX-CAJOP300-EE
Mounting Kit for LED Operator 4X-KITMINI
Manual No. Model Category
I570 3G3MX2 USERS MANUAL
I114E 3G3AX-MX2-CRT-E COMPONET COMMUNICATION OPTION BOARD USERS MANUAL
I112E 3G3AX-MX2-DRT-E DEVICENET COMMUNICATION OPTION BOARD USERS MANUAL
I574 3G3AX-MX2-ECT ETHERCAT COMMUNICATION OPTION BOARD USERS MANUAL
I361 3G3AX-MX2-EIP-A ETHERNET/IP COMMUNICATION OPTION BOARD USERS MANUAL
I111E 3G3AX-MX2-PRT-E PROFIBUS COMMUNICATION OPTION BOARD USERS MANUAL
W453 CXONE-AL@@C/D-V@
WS02-DRVC01 OPERATION MANUAL
Read and Understand this Catalog
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have
any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year
(or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY
MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT
OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction
changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special
model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with
your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
Cat. No. I916-E4-02
Authorized Distributori
Asia Pacific Head Office:
OMRON ASIA PACIFIC PTE. LTD.
438A Alexandra Road
#05-05/08
(Lobby 2) Alexandra Technopark
Singapore 119967
Tel: (65) 6835 3011 Fax: (65) 6835 2711
E-mail: ask@ap.omron.com
Website: www.omron-ap.comeb .omr n
Singapore Office:
OMRON ELECTRONICS PTE. LTD.
438A Alexandra Road, #05-05/08
(Lobby 2) Alexandra Technopark
Singapore 119967
Tel: (65) 6547 6789
Fax: (65) 6547 6769
E-mail: mktg_sg@ap.omron.com
Malaysia Office:
OMRON ELECTRONICS SDN. BHD.
1101 Level 11 Uptown 1
1 Jalan SS21/58 Damansara Uptown
47400 Petaling Jaya, Selangor
Malaysia
Tel: (60-3) 7688 2888
Fax: (60-3) 7688 2833
E-mail: my_enquiry@ap.omron.com
Thailand Office:
OMRON ELECTRONICS CO. LTD.
Rasa Tower 2 16th Floor
555 Phaholyothin Road
Chatuchak, Bangkok
10900, Thailand
Tel: (66-2) 937 0500
Fax: (66-2) 937 0501
CRM Call Centre: (66-2) 942 6700
E-mail: th_enquiry@ap.omron.com
Australia Offices:
Sydney Office:
OMRON ELECTRONICS PTY. LTD.
Omron House
71 Epping Road, North Ryde
Sydney, New South Wales 2113
Australia
Tel: (61-2) 9878 6377
Fax: (61-2) 9878 6981
Toll Free: 1800 678838
E-mail: au_enquiry@ap.omron.com
Melbourne Office:
OMRON ELECTRONICS PTY. LTD.
Axxess Corporate Park
Unit 98, 45 Gilby Road
Mt Waverley Victoria 3149
Australia
Tel: (61-3) 8588 2600
Fax: (61-3) 8588 2690
E-mail: au_enquiry@ap.omron.com
Brisbane Office:
OMRON ELECTRONICS PTY. LTD.
Unit 14, 1378 Lytton Road
Hemmant 4174, Queensland
Australia
Tel: (61-7) 3859 3900
Fax: (61-7) 3348 8701
E-mail: au_enquiry@ap.omron.com
Adelaide Office:
OMRON ELECTRONICS PTY. LTD.
Suite 12, 18 Humpheries Terrace
Kilkenny, SA 5009
Australia
Tel: (61-8) 8440 6412
Fax: (61-8) 8345 1204
E-mail: au_enquiry@ap.omron.com
New Zealand Office:
OMRON ELECTRONICS LTD.
65 Boston Road, Mt Eden
Private Bag 92620
Symonds Street, Auckland
New Zealand
Tel: (64-9) 358 4400
Fax: (64-9) 358 4411
E-mail: nz_enquiry@ap.omron.com
Indonesia Office:
PT. OMRON ELECTRONICS
Graha Pratama Building, 3A Floor
Jl. M.T. Haryono Kav 15
Jakarta Selatan 12810
Indonesia
Tel: (62-21) 8370 9555
Fax: (62-21) 8370 9550
E-mail: id_enquiry@ap.omron.com
Philippines Office:
OMRON ASIA PACIFIC PTE. LTD.
MANILA REPRESENTATIVE OFFICE
2nd Floor, Kings Court II Building
2129 Do Chino Roces Avenue
Corner Dela Rosa Street
1231 Makati City, Metro Manila
Philippines
Tel: (63-2) 811 2831
Fax: (63-2) 811 2583
E-mail: ph_enquiry@ap.omron.com
Vietnam Offices:
OMRON ASIA PACIFIC PTE. LTD.
HANOI REPRESENTATIVE OFFICE
6th Floor, 92 Hoang Ngan Street
Trung Hoa, Cau Giay
Hanoi, SR Vietnam
Tel: (84-4) 3556 3444
Fax: (84-4) 3556 3443
E-mail: hn_enquiry@ap.omron.com
HO CHI MINH REPRESENTATIVE OFFICE
2nd Floor, IWA, 102 A-B, Cong Quynh,
P. Pham Ngu Lao, Q1, TP. Ho Chi Minh
SR Vietnam
Tel: (84-8) 3920 4338
Fax: (84-8) 3920 4335
E-mail: hcm_enquiry@ap.omron.com
India Offices:
Mumbai Office:
OMRON AUTOMATION PVT. LTD.
Kalpataru Square, Office Unit No. 32
off Andheri-Kurla Road, Andheri (East),
Mumbai- 400059
India
Tel: (91-22) 4228 8400
Fax: (91-22) 4275 5602
E-mail: in_enquiry@ap.omron.com
Bangalore Office:
OMRON AUTOMATION PVT. LTD.
No. 43, G.N. Complex
St.Johns Road
Bangalore - 560 042
India
Tel: (91-80) 4072 6400/401
Fax: (91-80) 4146 6403
E-mail: bangalore_enquiry@ap.omron.com
Gurgaon Office:
OMRON AUTOMATION PVT. LTD.
No.108 &103-106, 1/F, Sewa Corporation Park,
MG Road, Gurgaon, Haryana 122002
India
Tel: (91-124) 4921700
Fax:(91-124) 4921777
E-mail: newdelhi_enquiry@ap.omron.com