Self-powered Totalizer H7E C-7
Counters
Self-powered Totalizer
H7E
Compact Economical Totalizer with High Visibility
Available with Backlit LCD Display
Large display with 8.6-mm character height.
Includes new models with backlight for improved visibility in dimly lit places. (Requires 24-VDC power supply.)
Black and light-gray cases now available.
PNP/NPN universal DC voltage input types now available.
Battery is replaceable for Totalizer reuse and conservation of the environment.
Key-protect switch to prevent faulty reset key operation.
Dual operation mode.
Front face compatible with NEMA4/IP66.
Short body, all models have a depth of 48.5 mm.
Finger protection terminal block conforms to VDE0106 Part100.
Conforms to UL, CSA, and CE marking.
Conforms to EN61010-1 (pollution degree 2/overvoltage category III.)
Conforms to EMC standards and EN61326, thus allowing use in residential, commercial and light- and heavy-industry environ-
ments.
Six-language instruction manual provided.
PCB-mounting models available. (Requires 3-V power supply.)
Broad Line-up of the H7E Series
Contents
Self-powered Totalizers
H7EC..................................................................................................................... C-9
H7ET ..................................................................................................................... C-17
H7ER..................................................................................................................... C-25
H7E@-N@P ........................................................................................................... C-31
Common to All Totalizers
Accessories........................................................................................................... C-35
Precautions ........................................................................................................... C-37
RC
H7E
Total Counter
8-digit
Time Counter Tachometer
H7EC H7ET H7ER H7E@-N@P
PCB-mounting Counter
Total Counter (8-digit)
Time Counter (999999.9h)
999999.9h/
3999d23.9h
999h59min59s/
9999h59.9min
1,000 s-1 with
1 pulse/rev. encoder
1,000.0 s-1 with
10 pulse/rev. encoder
1,000 min-1 with
60 pulse/rev. encoder
10,000 min-1 with
60 pulse/rev. encoder
1,000.0 min-1 with
600 pulse/rev. encoder
C-8 Self-powered Totalizer H7E
Self-powered Total Counter H7EC C-9
Counters
Self-powered Total Counter
H7EC
Eight-digits, counting range 0 to 99999999.
Dual input speed: 30 Hz ←→ 1 kHz (except for AC/DC multi-
voltage input models)
Model Number Structure
Model Number Legend
Ordering Information
Total Counters
Accessories (Order Separately)
Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket.
1 2 3
H7EC - N -
1. Count Input
2. Case Color
3. Display
None: No-voltage input
V: PNP/NPN universal DC voltage input
FV: AC/DC multi-voltage input
None: Light gray
B: Black
None: 7-segment LCD without backlight
H: 7-segment LCD with backlight
Count input Max. counting speed Display Model
Light-gray body Black body
PNP/NPN universal DC
voltage input
30 Hz ←→ 1 kHz
(switchable)
7-segment LCD with
backlight
H7EC-NV-H H7EC-NV-BH
7-segment LCD H7EC-NV H7EC-NV-B
AC/DC multi-voltage input 20 Hz 7-segment LCD H7EC-NFV H7EC-NFV-B
No-voltage 30 Hz ←→ 1 kHz
(switchable)
7-segment LCD H7EC-N H7EC-N-B
Lithium Battery Y92S-36
Wire-wrap Terminal (set of two Terminals) Y92S-37
Compact Flush Mounting Bracket (See note.) Y92F-35
Flush Mounting Adapter 26 mm × 45.3 mm Y92F-75
27.5 mm × 52.5 mm Y92F-76
24.8 mm × 48.8 mm Y92F-77B
C-10 Self-powered Total Counter H7EC
Specifications
General
Note: 1. Separately ordered Wire-wrap Terminals (Y92S-37) are required.
2. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
Ratings
Note: ON/OFF ratio 1:1
Item H7EC-NV-@
H7EC-NV-@HH7EC-NFV-@H7EC-N-@
Operating mode Up type
Mounting method Flush mounting
External connections Screw terminals, optional Wire-wrap Terminals (see note 1)
Reset External/Manual reset
Number of digits 8
Count input PNP/NPN universal DC voltage in-
put
AC/DC multi-voltage input No-voltage input
Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 2)
Max. counting speed 30 Hz/1 kHz 20 Hz 30 Hz/1 kHz
Case color Light gray or black (-B models)
Attachment Waterproof packing, flush mounting bracket
Approved standard UL863, CSA C22.2 No.14, Lloyds
Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III)
Conforms to VDE0106/P100
Item H7EC-NV-@
H7EC-NV-@HH7EC-NFV-@H7EC-N-@
Supply voltage Backlight model: 24 VDC (0.3 W max.)
(only for backlight)
No-backlight model: Not required
(powered by built-in battery)
Not required (powered by built-in battery)
Count input High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC
(Input impedance: Approx. 4.7 k)
High (logic) level: 24 to 240 VAC/VDC,
50/60 Hz
Low (logic) level: 0 to 2.4 VAC/VDC, 50/
60 Hz
No voltage input
Maximum short-circuit impedance:
10 k max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 k min.
Reset input No voltage input
Maximum short-circuit impedance:
10 k max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 k min.
Max. counting
speed (see note) 30 Hz or 1 KHz
(Switchable with switch)
20 Hz 30 Hz or 1 KHz
(Switchable with switch)
Minimum signal
width 20 Hz: 25 ms
30 Hz: 16.7 ms
1 KHz: 0.5 ms
Reset system External reset and manual reset: Minimum signal width of 20 ms
Terminal screw
tightening torque 0.98 N·m max.
Ambient tempera-
ture Operating: -10°C to 55°C (with no condensation or icing)
Storage: -25°C to 65°C (with no condensation or icing)
Ambient humidity Operating 25% to 85%
Self-powered Total Counter H7EC C-11
Counters
Characteristics
Note: Weight includes waterproof packing and flush mounting bracket.
Reference Value
Item H7EC-NV-@
H7EC-NV-@HH7EC-NFV-@H7EC-N-@
Insulation resistance 100 M min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts, and between the backlight power
supply terminal and count input termi-
nals/reset terminals for backlight mod-
els
100 M min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
and between count input terminals and
reset terminals
100 M min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
and between the backlight power sup-
ply terminal and count input terminals/
reset terminals for backlight models
3,700 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
2,200 VAC, 50/60 Hz for 1 min between
reset terminals and exposed non-cur-
rent-carrying metal parts and between
count input terminals and reset termi-
nals
1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
Impulse withstand
voltage 4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
3 kV between input terminals and reset
terminals
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
±600 V (Between count input terminals/
Between reset terminals)
±480 V (Between the backlight power
supply terminals for backlight models)
±1.5 kV (Between count input termi-
nals)
±500 V (Between reset terminals)
±500 V (Between count input terminals/
Between reset terminals)
Static immunity ±8 kV (malfunction)
Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance Malfunction: 200 m/s2 3 times each in 6 directions
Destruction: 300 m/s2 3 times each in 6 directions
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group 1 class B
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power line (level 3)
2 kV I/O signal line (level 4)
Degree of protection Front panel: IP66, NEMA4
Terminal block: IP20
Weight (see note) No-backlight model: Approx. 60 g
Backlight model: Approx. 65 g
Approx. 60 g Approx. 60 g
Item Value Note
Battery life 7 years min. with continuous input at 25°C
(lithium battery)
The battery life is calculated according to the conditions in the left column and
therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.
C-12 Self-powered Total Counter H7EC
Connections
Terminal Arrangement
Bottom view: View of the Total Counter rotated horizontally 180°
Connections
H7EC Total Counter
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are func-
tionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 100 µA
Note: *Recommended Power supply; eg. OMRON S8VS
Backlight Model No-backlight Model
Backlight
24 VDC
Count
input
Reset
input
Count
input
Reset
input
PNP/NPN Universal DC Voltage Input Model With Backlight
1. Contact Input (Input by a Relay or Switch Contact) 2. Solid-state Input
Relay
Input Reset
Relay
or Switch or Switch
Input Reset
Backlight
24 VDC
Open collector of a
PNP transistor
Open collector of a
PNP transistor
Backlight
24 VDC*
or Open collector of an
NPN transistor
or Open collector of an
NPN transistor
Self-powered Total Counter H7EC C-13
Counters
No-voltage Input Model
1. Contact Input (Input by a Relay or Switch Contact)
AC/DC Multi-voltage Input Model
PNP/NPN Universal DC Voltage Input Model Without Backlight
1. Contact Input (Input by a Relay or Switch Contact)
2. Solid-state Input
Relay Input Reset Relay
or Switch or Switch
or Switch
Input Reset
Relay
Relay
Input Reset
or Switch or Switch
Relay
Input Reset
Relay
or Switch or Switch
Input Reset
Open collector of a
PNP transistor
Open collector of a
PNP transistor
or Open collector of an
NPN transistor
or Open collector of an
NPN transistor
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are
functionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 100 µA
or Open collector of
an NPN transistor
Note: Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 1 µA
Terminals 2 and 4 are
internally connected.
Note: Use Relays and Switches that have high contact reli-
ability because the current flowing from terminals 1 or
3 is small. It is recommended that OMRON's G3TA-
IA/ID be used as the SSR.
2. Solid-state Input
(Open Collector Input of an NPN Transistor)
Open collector of an
NPN transistor
Open collector of an
NPN transistor
Terminals 2 and 4 are
internally connected.
Note: 1. Residual voltage in the output section of Proximity
Sensors or Photoelectric Sensors becomes less than
0.5 V because the current flowing from terminals 1 or 3
is small thus allowing easy connection.
2. Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 1 µA
C-14 Self-powered Total Counter H7EC
Operation
Operating Modes
Nomenclature
Note: Perform switch setting before mounting to a control panel.
H7EC Total Counter
Reset
Counting display values
Full-scale
Count input
Incrementing Operation
(Up)
(Full-scale
1)
H7EC
1 kHz
Front view
Bottom view
Reset Key
Key-protect Switch
Counting speed switch
Key-protect
Front panel
ON
Terminal block
Counting speed
Front panel
Terminal block
For all models except for H7EC-NFV-@.
If the counting speed setting is changed,
the present value will not be held and so
press the Reset Key on the front panel.
Setting
(see note)
30 Hz
(default setting)
Setting
(see note)
OFF
(default setting)
Reset the count value. Not operable
under key-protect.
Concave
side
Concave
side
The Reset Key is not operable while the
key-protect switch is set to ON.
Concave
side
Concave
side
Self-powered Total Counter H7EC C-15
Counters
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H7EC-N
Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details.
22.2+0.5
0
45+0.5
0
22.2+0.5
0
Panel Cutout
Dimensions with Flush Mounting Bracket
Separate mounting
Dense mounting
40 min.
(48 Units 2.5)+1.0
0
Waterproofing is not possible for
dense mounting
When mounting, insert the Counter into
the cutout, insert the adapter from the
back and push in the Counter while
making the gap between the front panel
and the cutout panel as small as
possible. Use screws to secure the
Counter. If waterproofing is desired,
insert the waterproof packing.
When several Counters are installed,
ensure that the ambient temperature
will not exceed specifications.
The appropriate thickness of the panel
is 1 to 5 mm.
M3.5 terminal screw
C-16 Self-powered Total Counter H7EC
Self-powered Time Counter H7ET C-17
Counters
Self-powered Time Counter
H7ET
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or
999h59m59s ←→ 9999h59.9m
Model Number Structure
Model Number Legend
Ordering Information
Time Counters
Accessories (Order Separately)
Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket.
1 2 3 4
H7ET - N -
1. Count Input
2. Time Range
3. Case Color
4. Display
None: No-voltage input
V: PNP/NPN universal DC voltage input
FV: AC/DC multi-voltage input
None: 999999.9h/3999d23.9h
1: 999h59m59s/9999h59.9m
None: Light gray
B: Black
None: 7-segment LCD without backlight
H: 7-segment LCD with backlight
Timer input Display Time range
999999.9h ←→ 3999d23.9h
(switchable) 999h59min59s ←→ 9999h59.9min
(switchable)
Light-gray body Black body Light-gray body Black body
PNP/NPN universal DC volt-
age input
7-segment LCD with back-
light
H7ET-NV-H H7ET-NV-BH H7ET-NV1-H H7ET-NV1-BH
7-segment LCD H7ET-NV H7ET-NV-B H7ET-NV1 H7ET-NV1-B
AC/DC multi-voltage input 7-segment LCD H7ET-NFV H7ET-NFV-B H7ET-NFV1 H7ET-NFV1-B
No-voltage input 7-segment LCD H7ET-N H7ET-N-B H7ET-N1 H7ET-N1-B
Lithium Battery Y92S-36
Wire-wrap Terminal (set of two terminals) Y92S-37
Compact Flush Mounting Bracket (See note.) Y92F-35
Flush Mounting Adapter 26 mm × 45.3 mm Y92F-75
27.5 mm × 52.5 mm Y92F-76
24.8 mm × 48.8 mm Y92F-77B
C-18 Self-powered Time Counter H7ET
Specifications
General
Note: 1. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
2. “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included.
Ratings
Item H7ET-NV-@
H7ET-NV-@HH7ET-NFV-@H7ET-N-@H7ET-NV1-@
H7ET-NV1-@HH7ET-NFV1-@H7ET-N1-@
Operating mode Accumulating
Mounting method Flush mounting
External connections Screw terminals
Reset External/Manual reset
Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 1)
Number of digits 7
Time range 0.0h to 999999.9h ←→ 0.0h to 3999d23.9h
(switchable with switch)
0s to 999h59min59s ←→ 0.0min to 9999h59.9min
(switchable with switch)
Timer input PNP/NPN univer-
sal DC voltage in-
put
AC/DC multi-volt-
age input
No-voltage input PNP/NPN univer-
sal DC voltage in-
put
AC/DC multi-volt-
age input
No-voltage input
Case color Light gray or black (-B models)
Attachment Waterproof packing, flush mounting bracket, time unit labels (see note 2)
Approved standard UL863, CSA C22.2 No.14, Lloyds
Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III)
Conforms to VDE0106/P100
Item H7ET-NV@-@
H7ET-NV@-@HH7ET-NFV@-@H7ET-N@-@
Supply voltage Backlight model: 24 VDC (0.3 W max.)
(for backlight)
No-backlight model: Not required (pow-
ered by built-in battery)
Not required (powered by built-in battery)
Timer input High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC
(Input impedance: Approx. 4.7 k)
High (logic) level: 24 to 240 VAC/VDC,
50/60 Hz
Low (logic) level: 0 to 2.4 VAC/VDC, 50/
60 Hz
No voltage input
Maximum short-circuit impedance:
10 k max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 k min.
Reset input No voltage input
Maximum short-circuit impedance:
10 k max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 k min.
Minimum pulse
width 1 s
Reset system External reset and manual reset: Minimum signal width of 20 ms
Terminal screw
tightening torque 0.98 N·m max.
Ambient tempera-
ture Operating: -10°C to 55°C (with no condensation or icing)
Storage: -25°C to 65°C (with no condensation or icing)
Ambient humidity Operating: 25% to 85%
Self-powered Time Counter H7ET C-19
Counters
Characteristics
Note: Weight includes waterproof packing and flush mounting bracket.
Reference Value
Item H7ET-NV@-@
H7ET-NV@-H@H7ET-NFV@-@H7ET-N@-@
Time accuracy ±100 ppm (25°C)
Insulation resistance 100 M min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts, and between the backlight pow-
er supply and timer input terminals/re-
set terminals for backlight models
100 M min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts and between timer input termi-
nals and reset terminals
100 M min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts and between the backlight power
supply and timer input terminals/reset
terminals for backlight models
3,700 VAC, 50/60 Hz for 1 min between
timer input terminals and exposed non-
current-carrying metal parts
2,200 VAC, 50/60 Hz for 1 min between
reset terminals and exposed non-cur-
rent-carrying metal parts and between
timer input terminals and reset termi-
nals
1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts
Impulse withstand
voltage 4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
3 kV between timer input terminals and
reset terminals
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
±600 V (Between timer input terminals/
Between reset terminals)
±480 V (Between the backlight power
supply terminals for backlight models)
±1.5 kV (Between timer input termi-
nals)
±500 V (Between reset terminals)
±500 V (Between timer input terminals/
Between reset terminals)
Static immunity ±8 kV (malfunction)
Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance Malfunction: 200 m/s2 3 times each in 6 directions
Destruction: 300 m/s2 3 times each in 6 directions
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group 1 class B
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power line (level 3)
2 kV I/O signal line (level 4)
Degree of protection Front panel: IP66, NEMA4 with waterproof packing
Terminal block: IP20
Weight (see note) No-backlight model: Approx. 60 g
Backlight model: Approx. 65 g
Approx. 60 g Approx. 60 g
Item Value Note
Battery life 10 years min. with continuous input at
25°C (lithium battery)
The battery life is calculated according to the conditions in the left column and
therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.
C-20 Self-powered Time Counter H7ET
Connections
Terminal Arrangement
Bottom view: View of the Time Counter rotated horizontally 180°
Connections
H7ET Time Counter
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are func-
tionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 1 µA
Note: *Recommended power supply; eg. OMRON S8VS
Backlight Model No-backlight Model
Backlight
24 VDC
Timer
input
Reset
input
Timer
input
Reset
input
PNP/NPN Universal DC Voltage Input Model With Backlight
1. Contact Input (Input by a Relay or Switch Contact)
Relay
Input Reset
Relay
or Switch or Switch
Input Reset
2. Solid-state Input
Backlight
24 VDC
Open collector of a
PNP transistor
Open collector of a
PNP transistor
Backlight
24 VDC*
or Open collector of an
NPN transistor
or Open collector of an
NPN transistor
Self-powered Time Counter H7ET C-21
Counters
Relay
No-voltage Input Model
1. Contact Input (Input by a Relay or Switch Contact)
AC/DC Multi-voltage Input Model
PNP/NPN Universal DC Voltage Input Model Without Backlight
1. Contact Input (Input by a Relay or Switch Contact)
2. Solid-state Input
Relay
Input Reset
Relay
or Switch or Switch
Input Reset
Relay
Relay
Input Reset
or Switch or Switch
or Switch
Input Reset
Relay Input Reset Relay
or Switch or Switch
Open collector of a
PNP transistor
Open collector of a
PNP transistor
or Open collector of an
NPN transistor
or Open collector of an
NPN transistor
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are
functionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 1 µA
or Open collector of
an NPN transistor
Terminals 2 and 4 are
internally connected.
Note: Use Relays and Switches that have high contact relia-
bility because the current flowing from terminals 1 or
3 is as small as approx. 10 µA. It is recommended
that OMRON's G3TA-IA/ID be used as the SSR.
2. Solid-state Input
(Open Collector Input of an NPN Transistor)
Open collector of an
NPN transistor
Open collector of an
NPN transistor
Terminals 2 and 4 are
internally connected.
Note: 1. Residual voltage in the output section of Proximity
Sensors or Photoelectric Sensors becomes less
than 0.5 V because the current flowing from termi-
nals 1 or 3 is as small as approx. 10 µA, thus allow-
ing easy connection.
2. Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 1 µA
C-22 Self-powered Time Counter H7ET
Operation
Operating Modes
Nomenclature
Note: Perform switch setting before mounting to a control panel.
H7ET Time Counter
Full-scale
Reset
Timer input
Timer display values
Incrementing Operation
(Up)
Internal clock
timer value
(Full-scale
0.1 (1))
H7ET
Front view
Bottom view
Reset Key
Key-protect Switch
Time-range switch
Key-protect
Front panel
ON
Terminal block
H7ET-N@@-@@
Front panel
0.0h to 3999d23.9h
Terminal block
Time range
H7ET-N@@1-@@
0.0min to 9999h59.9min
If the time-range setting is
changed, the present
value will not be held and
so press the Reset Key on
the front panel.
Setting
(see note)
0.0h to 999999.9h
(default setting)
0s to 999h59min59s
(default setting)
Setting
(see note)
OFF
(default setting)
Reset the count value. Not operable
under key-protect.
Concave
side
Concave
side
Concave
side
Concave
side
The Reset Key is not operable while the
key-protect switch is set to ON.
Self-powered Time Counter H7ET C-23
Counters
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H7ET-N
Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details.
22.2+0.5
0
45+0.5
0
22.2+0.5
0
Dimensions with Flush Mounting Bracket
Panel Cutout
Separate mounting
Dense mounting
40 min.
(48 Units 2.5)+1.0
0
Waterproofing is not possible
for dense mounting
When mounting, insert the Counter into
the cutout, insert the adapter from the
back and push in the Counter while
making the gap between the front panel
and the cutout panel as small as
possible. Use screws to secure the
Counter. If waterproofing is desired,
insert the waterproof packing.
When several Counters are installed,
ensure that the ambient temperature
will not exceed specifications.
The appropriate thickness of the panel
is 1 to 5 mm.
C-24 Self-powered Time Counter H7ET
Self-powered Tachometer H7ER C-25
Counters
Self-powered Tachometer
H7ER
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s-1/1000 min-1 or 1000.0 s-1 /1000.0 min-1
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min-1
Model Number Structure
Model Number Legend
Ordering Information
Tachometers
Accessories (Order Separately)
Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket.
1 2 3 4
H7ER - N -
1. Count Input
2. Number of Digits
3. Case Color
4. Display
None: No-voltage input
V: PNP/NPN universal DC voltage input
None: 4 digits
1: 5 digits
None: Light gray
B: Black
None: 7-segment LCD without backlight
H: 7-segment LCD with backlight
Count input Display Max. revolutions displayed (applicable encoder resolution)
1000 s-1 (1 pulse/rev.),
1000 min-1 (60 pulse/rev.) 1000.0 s-1 (10 pulse/rev.),
1000.0 min-1 (600 pulse/rev.) ←→
10000 min-1 (60 pulse/rev.) (switchable)
Light-gray body Black body Light-gray body Black body
PNP/NPN universal
DC voltage input
7-segment LCD
with backlight
H7ER-NV-H H7ER-NV-BH H7ER-NV1-H H7ER-NV1-BH
7-segment LCD H7ER-NV H7ER-NV-B H7ER-NV1 H7ER-NV1-B
No-voltage input 7-segment LCD H7ER-N H7ER-N-B --- ---
Lithium Battery Y92S-36
Wire-wrap Terminal (Set of two Terminals) Y92S-37
Compact Flush Mounting Bracket (See note.) Y92F-35
Flush Mounting Adapter 26 mm × 45.3 mm Y92F-75
27.5 mm × 52.5 mm Y92F-76
24.8 mm × 48.8 mm Y92F-77B
C-26 Self-powered Tachometer H7ER
Specifications
General
Note: 1. Reset is not available.
2. When there is no input, the display will be 0.0 or 0.
3. Separately ordered Wire-wrap Terminals (Y92S-37) are required.
4. Only PNP/NPN Universal DC voltage input models have a backlight.
5. “rpm”, “rps”, “s-1” and “min-1” labels are included.
Ratings
Item H7ER-NV-@
H7ER-NV-@HH7ER-N-@H7ER-NV1-@
H7ER-NV1-@H
Operating mode Up type
Mounting method Flush mounting
External connections Screw terminals, Wire-wrap Terminals (see note 3)
Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 4)
Number of digits 45
Count input PNP/NPN universal DC
voltage input
No-voltage input PNP/NPN universal DC voltage input
Max. counting speed 1 kHz 10 kHz
Max. revolutions displayed
(see note 5) 1,000 s-1 (When encoder resolution of 1 pulse/rev is
used.)
1,000 min-1 (When encoder resolution of 60 pulse/rev
is used.)
1,000.0 s-1 (When encoder resolution of 10 pulse/rev
is used.)
1,000.0 min-1 (When encoder resolution of 600 pulse/
rev is used.)
←→ 10,000 min-1 (When encoder resolution of
60 pulse/rev is used.)
(Switchable with switch)
Attachment Waterproof packing, flush mounting bracket, revolution unit labels (see note 5)
Approved standard UL863, CSA C22.2 No.14, Lloyds
Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III)
Conforms to VDE0106/P100
Item H7ER-NV@-@
H7ER-NV@-@HH7ER-N-@
Supply voltage Backlight model: 24 VDC (0.3 W max.) (for backlight
lit)
No-backlight model: Not required (powered by built-
in battery)
Not required (powered by built-in battery)
Count input High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC
(Input impedance: Approx. 4.7 k)
No voltage input
Maximum short-circuit impedance: 10 k max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 k min.
Max. counting speed 4-digit models:1 kHz
5-digit models:10 kHz
1 kHz
Minimum signal width 10 kHz: 0.05 ms
1 kHz: 0.5 ms
Terminal screw tightening torque 0.98 N·m max.
Ambient temperature Operating: -10°C to 55°C (with no condensation or icing)
Storage: -25°C to 65°C (with no condensation or icing)
Ambient humidity Operating: 25% to 85%
Self-powered Tachometer H7ER C-27
Counters
Characteristics
Note: Weight includes waterproof packing and flush mounting bracket.
Reference Value
Item H7ER-NV@-@
H7ER-NV@-@HH7ER-N-@
Insulation resistance 100 M min. (at 500 VDC) between current-carrying
metal parts and exposed non-current-carrying metal
parts, and between the backlight power supply and
count input terminals/reset terminals for backlight
models
100 M min. (at 500 VDC) between current-carrying
metal parts and exposed non-current-carrying metal
parts
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-car-
rying metal parts and exposed non-current-carrying
metal parts and between the backlight power supply
and count input terminals/reset terminals for back-
light models
1,000 VAC, 50/60 Hz for 1 min between current-car-
rying metal parts and exposed non-current-carrying
metal parts
Impulse withstand voltage 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
±600 V (Between count input terminals)
±480 V (Between the backlight power supply termi-
nals for backlight models)
±500 V (Between count input terminals)
Static immunity ±8 kV (malfunction)
Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance Malfunction: 200 m/s2 3 times each in 6 directions
Destruction: 300 m/s2 3 times each in 6 directions
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group 1 class B
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power line (level 3)
2 kV I/O signal line (level 4)
Degree of protection Front panel: IP66, NEMA4 with waterproof packing
Terminal block: IP20
Weight (see note) No-backlight model:Approx. 60 g
Backlight model: Approx. 65 g
Item Value Note
Battery life 7 years min. with continuous input at 25°C
(lithium battery)
The battery life is calculated according to the conditions in the left column and
therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.
C-28 Self-powered Tachometer H7ER
Connections
Terminal Arrangement
Bottom view: View of the Tachometer rotated horizontally 180°
Connections
H7ER Tachometer
Note: Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 100 µA (1 µA for no-voltage input model)
Backlight Model No-backlight Model
Backlight
24 VDC
Pulse
input
Pulse
input
No-voltage Input Model
Transistor Input (Open Collector of an NPN Transistor)
PNP/NPN Universal DC Voltage Input Models Without Backlight
Transistor Input
Input
Input
or
Input
or
PNP/NPN Universal DC Voltage Input Models With Backlight
Transistor Input
Open collector of
an NPN transistor
Open collector of
an PNP transistor
Backlight
24 VDC*
Open collector of
an NPN transistor
Open collector of
an PNP transistor
Open collector of
an NPN transistor
*Recommended power supply; eg. OMRON S8VS
Self-powered Tachometer H7ER C-29
Counters
Operation
Operating Modes
Nomenclature
Note: Perform switch setting before mounting to a control panel.
0.25 s
Internal gate
Display refreshed
Internal count value
Counter reset
Refresh
Number display
H7ER Tachometer
Incrementing Operation
Within Unit Time (Up)
Count period
(1 s)
Count period
(1 s)
Previous count
value display
Display refreshed
every 1.25 s
Display refreshed
every 1.25 s
1000.0 min-1
1000.0 s-1
1000 s-1
1000 min-1
H7ER
Concave
side
Concave
side
Front view
Bottom view
Counting speed switch
For H7ER-NV1-@@
Front panel
Terminal block
H7ER-NV1-@@ 60 pulse/rev. "min-1" or "rpm"
"min-1" or "rpm"
600 pulse/rev.
10 pulse/rev. "s-1" or "rps"
60 pulse/rev. "min-1" or "rpm"
1 pulse/rev. "s-1" or "rps"
Counting Speed Switch Settings and Unit Label Application
Model
Not used
Counting speed
switch setting
(see note)
Max. revolutions
displayed
Applicable encoder
resolution
Applicable unit
label
H7ER-N-@
H7ER-NV-@@
No setting is
required
10000 min-1
(default setting)
C-30 Self-powered Tachometer H7ER
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H7ER-N
Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details.
22.2+0.5
0
45+0.5
0
22.2+0.5
0
Dimensions with Flush Mounting Bracket
Panel Cutout
Separate mounting
Dense mounting
40 min.
(48 Units 2.5)+1.0
0
Waterproofing is not possible
for dense mounting
When mounting, insert the Counter into
the cutout, insert the adapter from the
back and push in the Counter while
making the gap between the front panel
and the cutout panel as small as
possible. Use screws to secure the
Counter. If waterproofing is desired,
insert the waterproof packing.
When several Counters are installed,
ensure that the ambient temperature
will not exceed specifications.
The appropriate thickness of the panel
is 1 to 5 mm.
PCB-mounting Counters H7E@-N@PC-31
Counters
PCB-mounting Counters
H7E@-N@P
Dedicated for use on PCB.
Total Counters and Time Counter available.
Model Number Structure
Model Number Legend
Ordering Information
PC Board-use Counters
Accessory (Order Separately)
1 2
H7E - N P
1. Function
2. Max. Counting Speed for H7EC Models
C: Total Counter
T: Time Counter
None: 1 kHz
L: 30 Hz
Count input Display Total counter Time counter
Max. counting speed
1 kHz 30 Hz
No-voltage input 7-segment LCD H7EC-NP H7EC-NLP H7ET-NP
Connecting Socket (28-pin) XR2A-2801-N
C-32 PCB-mounting Counters H7E@-N@P
Specifications
General
Ratings
Note: ON/OFF ratio 1:1
Characteristics
Note: The power supply terminals of the H7E@-N@P are considered as 3-VDC control terminals.
Item Total Counter Time Counter
H7EC-NP H7EC-NLP H7ET-NP
Operating mode Up type
Mounting method Direct mounting on PC Board or mounting on 28-pin socket
Reset External reset, Power-OFF reset
Number of digits 87
Time range --- 0.0h to 999999.9h
Max. counting speed 1 kHz 30 Hz ---
Count/Timer input No-voltage input
Display 7-segment LCD (character height: 8.6 mm)
Case color Transparent
Approved standard UL863, CSA C22.2 No.14
Item H7EC-NP
H7EC-NLP H7ET-NP
Supply voltage 3 VDC (2.7 to 3.3 VDC)
Count/Timer input No voltage input
Maximum short-circuit impedance: 10 k max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 k min.
Reset input
Max. counting speed (see note) 1 kHz: Minimum signal width of 0.5 ms
30 Hz: Minimum signal width of 16.7 ms
---
Minimum signal input width --- 1 s
Reset system External reset: Minimum signal width of 20 ms
Power-OFF reset: Minimum power OFF time of 500 ms
Ambient temperature Operating: -10°C to 55°C (with no condensation or icing)
Storage: -25°C to 65°C (with no condensation or icing)
Ambient humidity Operating: 25% to 85%
Item H7EC-NP
H7EC-NLP H7ET-NP
Time accuracy --- ±100 ppm (25°C)
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
±500 V (Between count or timer input terminals/Between reset terminals)
Static immunity ±8 kV (malfunction)
Vibration resistance Malfunction:0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction:0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance Malfunction:200 m/s2 3 times each in 6 directions
Destruction:300 m/s2 3 times each in 6 directions
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group 1 class B
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2)
8-kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
Immunity Conducted Disturbance (see note):EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst (see note): EN61000-4-4: 2-kV I/O signal line (level 4)
Weight Approx. 20 g
PCB-mounting Counters H7E@-N@PC-33
Counters
Connections
Terminal Arrangement
Connections
Power Supply and Battery Connections
Battery Connections
When designing a circuit, keep the power wiring connections shorter
than 50 mm. Refer to the connection diagram above for the proper
wiring polarity.
The life expectancy of a battery power supply can be calculated by
the following formula:
t = A/lc
Where,
t: Life expectancy of battery (h)
A: Battery capacity (mAh)
lc: H7E@-N@P current consumption (mA)
Example:
Battery life when using a 3-V lithium battery with a capacity of
1,200 mAh for the H7E@-N@P.
t = 1,200 [mAh]/20 × 10-3 [mA] = 60,000 hours (approx. 6.8 years)
The battery capacity varies depending on the type of battery used;
oxidized silver, mercury, or lithium battery.
Voltage Division of Power Supply Circuit
When necessary, the voltage from the battery may be divided by
resistances:
When doing so, however, ensure that the following equation bal-
ances:
E (V) × R2 / (R1 + R2) = 3 V
Allow a current high enough to flow through R1 so that the H7E@-
N@P receives sufficient current.
C is a film capacitor, of about 0.1 µF, and is intended to absorb noise
induced by the power lines.
Keep the wiring between the H7E@-N@P and R2 or C as short as
possible (within 50 mm).
Backup Circuit for Protection Against Power
Failure
Use a diode (D) having a forward voltage as small as possible (0.1 V
max. at IF of 20 µA).
Determine the ratio of R1 to R2 in accordance with the forward volt-
age of the diode to be used. Be aware that when the power supplied
to the H7E@-N@P has dropped to less than the voltage of the
backup circuit, the battery will discharge.
To protect the circuit against a momentary power failure, an alumi-
num electrolyte capacitor can be used in place of a battery, as shown
below:
When a capacitor is used, its backup time can be calculated by the
following formula:
t = C (V1 - V2) / Ic
Where,
t: Backup time (s)
C: Capacitance (µF)
V1: Supply voltage before power failure (V)
V2: Minimum operating voltage of H7E@-N@P (V)
Ic:H7E@-N@P current consumption (µA)
Example:
Backup time by an aluminum electrolytic capacitor of 100 µF. ( M i n i -
mum operating voltage of H7E@-N@P is 2.6 V.)
t = 100 µF × (3-2.6 V)/20 µA = 100 × 0.40/20 = 2.0 seconds
H7EC-N@P H7ET-NP
3-VDC external
power supply
Reset
input
Count
input
Reset
input
Timer
input
3-VDC external
power supply
RE
5 V 12 V 24 V
R12 k9.1 k33 k
R23 k3 k4.7 k
3-V battery
H7E@-N@P
H7E@-N@P
H7E@-N@P
3-V
bat-
tery Backup
circuit
H7E@-N@P
Backup
circuit
C-34 PCB-mounting Counters H7E@-N@P
Note that the above calculation provides an approximate value,
which varies depending on the environment under which the Counter
is used and also on the type of capacitors used. Provide some allow-
ance in selecting capacitors.
Keep the wiring between the H7E@-N@P and R2 or C as short as
possible (within 50 mm).
Input Connections
Input Connection Contact Input
When the H7EC-NP is used, relay chattering may be counted. Use
the H7EC-NLP, one of the low-speed input models.
Solid State Input
Use a transistor for input that satisfies the following conditions:
Collector breakdown voltage 50 V
Leakage current < 1 µA
Use a diode (D) having a forward voltage as small as possible (0.1 V
max. at IF of 20 µA).
Operation
Operating Modes
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Reset input Count/Timer input
Or Or
H7E@-N@P
Relay Relay
Open-collector Transistor Input
Reset input Count/Timer input
H7E@-N@P
TTL or C-MOS IC Input
Reset input Count/Timer input
TTL or C-MOS IC TTL or C-MOS IC
H7E@-N@P
H7EC Total Counter H7ET Time Counter
Reset
Counting display values
Full-scale
Count input
Full-scale
Reset
Timer input
Timer display values
Incrementing Operation
(Up)
(Full-scale
1)
Incrementing Operation
(Up)
Internal clock
timer value
(Full-scale
0.1
43
Flush Mounting
H7EC-N@P
Flush Mounting
H7ET-NP
DIP Terminal
DIP terminal x 8
Base
Eight, 0.8 dia.
17.3 max.
PCB Processing Dimensions
(Soldering Surface)
Section occupied
by the Counter
Note: Processing dimensions are
for 28-pin IC socket.
Self-powered Totalizer New H7E (Common) C-35
Counters
Accessories (Order Separately) (Common)
New H7E (Except for PCB-mounting Counter)
The New H7E models are supplied with a mounting bracket (Y92F-34) and nut. Additionally, the Y92F-75/-76/-77B Flush Mounting Adapters shown
here allow the New H7E models to be fitted to existing panel cutouts.
Degree of protection (front): IP40 (not waterproof)
The Y92F-76 adapter can be used. The DIP switch of the H7E@-N
can be operated in mounted condition. Vibration resistance and
shock resistant are the same level as the H7E@-N series.
The minimum mounting interval is 30 mm.
Note: An interval of 40 mm is recommended for easier wiring.
Do not allow the ambient temperature of the H7E@-N to exceed the
specifications (55°C).
Mounting is possible onto panels with a thickness of 1 to 5 mm.
RST
47.
6
2.4
1
8
.
6
4
2
6
×
+1.
0
22.2
+
0
.
5
22.2
+
0
.
5
0
4
5
+
0
.
5
30
min
.
Y92F-35 Compact Flush Mountin
g
Bracke
t
Panel
C
utou
t
D
e
n
se
o
u
n
t
i
n
g
Single mounting
28.8 24.2 22.2
45.2
48.2
53.8
4
24.8
48.8
RST
24.238 3850 22.2 27.5
48.2
52.5
60
45.2 4
31 24.2 22.2
45.2
48.2
63
72
4
26
26
45.3
63
Use mounting bracket supplied with the Counter Panel cutout
Use mounting bracket supplied with the Counter Panel Cutout
Y92F-75 Flush Mounting Adapter
for 26 × 45.3 Rectangular Cutout
Y92F-77B Flush Mounting Adapter
for 24.8 × 48.8 Rectangular Cutout
(Color: light gray)
Two, M4
Panel Cutout
(Color: light gray)
Use the Y92F-76 together with the Y92F-35 Compact
Flush Mounting Bracket.
(Color: light gray)
Two 4.5 dia . co unt ersun k ho les
Two 3.5 dia. mounting holes
Two, M3
Y92F-76 Flush Mounting Adapter
for 27.5 × 52.5 Rectangular Cutout
Note: The mounting panel
thickness should be
between 1 and 5 mm.
C-36 Self-powered Totalizer New H7E (Common)
When using the Wire-wrap Terminal, be sure to use the correct wires
and peripheral devices. (The correct wires, bits and sleeves are
shown in the table on the right.)
PCB-mounting Counters
XR2A-2801-N 28-pin Socket
Note: When using the Socket, use the PCB processing dimensions
previously provided.
44.8
24
48 2548.5 17.1
22
Y92S-37 Wire-wrap Terminal (Set of Two Terminals)
Wire-wrap terminal
(1 × 1 mm)
Wire Bit Sleeve Wrapped state
AWG22 2-A 2-B Normal
AWG24 1-A 1-B Normal
AWG26 3-A 1-B Normal
7.7
Y92S-36 Lithium Battery (3 V)
24.5 dia.
Self-powered Totalizer New H7E (Common) C-37
Counters
Precautions (Common)
New H7E (Except for PCB-mounting Counter)
!WARNING
This product has a built-in lithium battery. Do not short-circuit the
+ and terminals, charge, disassemble, deform, or expose the
battery to fire. The battery may explode (break), catch fire, or
cause liquid leakage.
!Caution
Do not use any battery other than the specified one (Y92S-36). Us-
ing another battery may cause liquid leakage or breakage, result-
ing in malfunction or injury.
!Caution
If a voltage other than the rated one is applied, internal elements
may be damaged.
Do not use the Counter in the following places:
Locations subject to direct sunlight.
Locations subject to corrosive gases.
Locations subject to dust.
Before Use
An insulation sheet has been inserted to maintain the quality of the
Totalizer in the event of a long period without use. Be sure to
remove this sheet before attempting to use the product.
Remove the insulation sheet and press the Reset Key on the front
panel of the Counter. (With the H7ER-N,-NV(-H),-NV1(-H), models,
“0” or “0.0” will be displayed after 1 s.)
Switch settings on the Counter must be performed before mounting
it to a control panel.
Do not use the Counter in the following locations:
Locations subject to severe changes in temperature.
Locations subject to condensation as the result of high humidity.
Mounting Precautions for Flush
Mounting
Although the operating section is watertight (conforming to NEMA4,
IP66), rubber packing is provided to avoid water leakage through the
gap between the Counter and panel cutout. Unless this rubber pack-
ing is tightly squeezed on, water may permeate inside the panel.
Therefore, be sure to tighten the screws for fixing the Y92F-34 Flush
Mounting Bracket. (Excessive tightening may also deform the rubber
packing.)
Screw for the Flush Mounting Bracket
Reset Input and Count/Timer Input
The H7E operates using its built-in Battery. If the H7E is connected
to a device that has +V and OUT terminals that are connected with
a diode as shown in the circuit diagram, the circuit indicated by the
arrow 1 or 2 will be formed when the device is turned OFF. As a
result, the H7E may be reset or count by one. It is recommended
that such devices not be connected to the H7E.
If an excessive voltage is applied to the count/timer input or reset
input terminals, the internal elements may be damaged.
Ensure that the following voltages are not exceeded:
PNP/NPN universal voltage input model: 30 VDC
AC/DC voltage input model:
At count/timer input: 240 VAC (peak voltage: 338V)
240 VDC
At reset input: No voltage can be applied. (No-voltage
input)
No-voltage input model: No voltage can be applied.
Avoid wiring close to high-tension or large-current lines.
Do not remove the outer case when voltage is being applied to the
power supply terminals or the input terminals.
The input for the H7E@-NFV-@ is a high-impedance circuit and so
influence from an induced voltage may result in malfunction. There-
fore, when the input signal wiring is longer than 10 m (line capaci-
tance of 120 pF/m, at room temperature), it is recommended that a
CR filter or a bleeder resistor is connected.
Reset Key
Insulation Sheet
Y92F-34 Adapte
r
Panel
The wider side must
face the panel.
H7E@-N
Devices
Internal
circuit
Count/Timer
input or reset
input
C-38 Self-powered Totalizer New H7E (Common)
Count Input, Timer Input or Reset Input
to More than One H7E Counter at a
Time
PNP/NPN Universal DC Voltage Input
Note: H (Reset ON) level must be 4.5 V minimum.
No-voltage Input
Note: 1. The leakage current of the transistor used for input must be
less than 1 µA.
2. The forward voltage of the diode must be as low as possible
(i.e., 0.1 V maximum with an IF of 20 µA) so that the voltage
between terminals 3 and 4 will be 0.5 V when the reset input
is ON.
Input and Power Supply
No-voltage Input Models
Do not impose voltage on the Counter if the Counter is a model that
operates with no-voltage input, otherwise the internal circuit of the
Counter may be damaged.
Do not connect any single input signal in parallel to Counter models
operating with no-voltage input and those operating with voltage
input, otherwise the Counters may malfunction.
When connecting a sensor to the Counter that operates with no-
voltage input, make sure that the sensor has open collector output.
When connecting an open collector input from a transistor to the
Counter that operates with no-voltage input, make sure that the
leakage current of the transistor is 1 µA maximum.
No-voltage Input and PNP/NPN Universal DC
Voltage Input Models
The operation of the Counter may be affected if the capacitance of
input lines exceeds 500 pF (about 10 m, with parallel wires of 2 x
2 mm).
Keep all wires as short as possible. When using shielded wire, line
capacitance may occur.
AC/DC Multi-voltage Input Models
When connecting count/timer input from an SSR to the Counter
that operates with AC/DC voltage input, use OMRON’s G3TA-IA/ID
SSR (for DC) whose leakage current is 0.1 mA max. or connect a
bleeder resistor in parallel to the input circuit of the Counter.
Backlight Power Supply
To reduce variation in the brightness of the backlight when using
more than one H7E with a backlight, use the same power supply for
all the backlights.
When connecting the DC power supply for the backlights, be sure
to connect the polarities correctly.
Input Verification with the H7ET Time
Counter
(When the time range is not set to 0s to
999h59min59s)
The decimal point of the LCD blinks every other second while an
input signal is being applied. If the decimal point is not blinking, the
input signal is not being received correctly. Check the input signal
connections.
Unit Label for Time Counter and
Tachometer
A unit label has been packed with the Counter. Use in accordance
with the application.
Battery Replacement
Remove the wiring when replacing the Battery. Do not come in con-
tact with any item to which high voltage is being applied. Doing so
may result in electric shock.
Before changing the Battery, the person should ensure that they are
not carrying any static electric charge.
Procedure for replacing the Battery (refer to the diagrams below):
1. Using the tool, pry open the lift-tab on the case. (1)
2. Pull the body out of its outer case. (2)
3. Lift the Battery up by the edge and remove it. (3)
When removing the Battery, do not come in contact with the dis-
play area or any internal parts.
4. Wipe the back of the new Battery before inserting it.
5. Ensure that the + and - terminals are correctly oriented.
6. After replacing the Battery, re-insert the body into its case. (4)
Check that the case is securely held in by the lift-tab.
or
or
H = 4.7 (k)/N + V
4.7 (k)/N + R
or
Sensor
or
or
or
Leakage current:
0.1 mA max.
*Bleeder resistor
The voltage between terminals 1 and 2 must be
1.5 V maximum when the SSR is OFF.
Self-powered Totalizer New H7E (Common) C-39
Counters
7. Press the Reset Key before use (not necessary for H7ER-N,-NV,-
NV1). (5) EN/IEC Standards
The count or timer input, reset input, and backlight power supply ter-
minals of the no-voltage input or PNP/NPN universal DC voltage
input models (H7E@-N,-N1, H7E@-NV(-H),-NV1(-H)) are not iso-
lated.
A SELV power supply conforming to Appendix H of IEC61010-1
should be used for the count or timer input, reset input and backlight
power supply terminals. A SELV power supply is a power supply for
which the input and output have double or reinforced insulation, and
for which the output voltage is 30 Vrms with 42.4 V peak or 60 VDC
max. (Only the H7E@-NV@-H has a backlight.) Recommended
24VDC power supply; eg. OMRON S8VS.
The terminals for count or timer input and reset input for AC/DC
multi-voltage input models have basic insulation.
Connect the reset input terminals to a device that does not have
exposed current-carrying parts and has basic insulation for 240 VAC.
Others
If the indicator keeps flickering or is OFF, the internal battery may be
close to the end of its service life. In such a case, it is suggested that
the battery be replaced.
PCB-mounting Counter
Power Supply
Use the power supply within the applicable range indicated by the
following waveform, while considering the ripple and voltage fluctu-
ations of the circuit power source.
The H7E@-N@P changes its mode as shown below depending on
the applied supply voltage.
Battery Replacement
To prevent unwanted reset when replacing the battery, connect the
new battery before disconnecting the old one. Otherwise, the voltage
supplied to the counter circuit drops, causing the present count value
to reset.
When designing the circuit board, providing two extra terminals for
battery connection will make the switch must simpler. See the sche-
matic diagram below:
Wiring polarity must be carefully observed, in order to prevent per-
manent damage to the Counters. Exercise caution when inserting
the Counter in the socket, to prevent reversed polarity.
(2)
(1)
(1)
(3)
(4)
(5)
Tool
Battery
3.6 V
2.6 V
Voltage
(V)
3.6
3
0
LCD
Beyond supply voltage
Looks darker
Looks normal
Flashes
No display No operation
Normal operation
Normal operation
Approx. 2.6
Approx. 2.2
Internal circuit
operation
Applicable
range
Battery life
guideline
H7E@-N@P
C-40 Self-powered Totalizer New H7E (Common)
Inputs
Do not route the wiring of the count, timer, or reset inputs in the vicin-
ity of, or in parallel to the wiring of high-voltage or inductive load cir-
cuits (such as motors and relays). Also, keep the wiring as short as
possible.
Be careful not to apply voltages exceeding the following values to the
count, timer, or reset terminals, otherwise the internal circuit may be
damaged.
No-voltage input: 3 VDC
General Information
The terminals are solder-plated. Finish soldering the terminals within
5 seconds, at a solder iron tip temperature of 250°C ± 10°.
Since the Counter is not flux-tight, do not use flux when soldering.
Avoid automatic and dip soldering. Manually solder the Counter onto
a PC board, and avoid cleaning as much as possible.
When mounting the Counter on a PC board with components which
consume higher current than the H7E@-N@P, observe the following
precautions.
1. Minimize the wiring (less than 50 mm) from the H7E@-N@P to the
power supply section.
2. Avoid placing the H7E@-N@P power, timer, counter, or reset input
circuit in parallel with circuits that consume large currents, partic-
ularly on the positive side.
When using the Counter in an environment where the Counter is
subject to frequent occurrences of vibration or shock, or when
mounting the Counter facing downwards or sideways, it is suggested
that the Counter be directly soldered to a PCB instead of using sock-
ets.
To Conform to EN/IEC Standards
Input terminals have no insulation from power supply terminals. The
power supply terminals must be supplied from a SELV source in
accordance with IEC61010-1 Annex H. SELV (separated extra-low
voltage) source is a power supply having double or reinforced insula-
tion between the primary and the secondary circuit and having out-
put voltage of 30 V rms max. and 42.4 V peak max. or 60 VDC max.
Cleaning
To prevent damage, the exterior of the Counter must not be exposed
to organic solvents (3.g. paint thinner or benzine), strong alkalis, or
strong acids.
Others
No user-serviceable parts.
Return to OMRON for all repairs.
H7E@-N@PPower supply Power supply
H7E@-N@P
H7E@-N@P
PC Board (Bad Example) PC Board (Good Example)
Placed far away from
the power supply.
Large-current-
consuming
components
Wired in parallel
with large-current-
carrying compo-
nents.
Bypass
capacitor
Bypass
capacitor
Large-current-
consuming
components
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. M064-E1-03