Gauge Pressure Sensor – E8F2
Differential Pressure Sensor – E8Y
In one miniature package, the E8Y differential pressure sensor solves applications
that previously required two individual sensors and a controller. It is an extremely
sensitive and reliable controller with discrete outputs for direct connections to your
PLC. A separate analog output makes the data available for charting. The E8Y puts
intelligent control at the site, freeing up your control system for faster performance.
Both the E8Y and E8F2 can be configured either normally open or normally closed. They
also offer a choice of Hysteresis or Window mode and auto or manual programming.
Make your pick-and-place and object detection applications perform at peak consistency
with the new E8F2 gauge pressure sensor. Its large LED face simultaneously displays an
analog bar graph and digital pressure values so you can monitor all aspects of your
application at a glance. These models also have two independent discrete outputs for
quick connections to your control device, and an analog output that simplifies data
collection. Choose either vacuum or pressure models to fit your application.
Differential Pressure Sensor – E8Y
Programming Options
Programming Options
Gauge Pressure Sensor – E8F2
31 x 30 x 30 mm
(1.22 x 1.18 x 1.18 in)
28 x 28 x 29 mm
(1.10 x 1.10 x 1.14 in)
Hysteresis Width
(set value)
Pressure Value
OFF
ON
Output
OFF Set Value ON Set Value
Normally Open
Hysteresis Width
(set value)
Pressure Value
OFF
ON
Output
Teach 1 (standard value)
OFF
Point
Using actual object
Window width
(set value)
ON
Point
Normally Open
These programming
methods are ideal for
detection applications.
The ‘Window mode’ is ideal
for applications where you
have to maintain a specific
pressure range.
The manual Window
mode requires you to
set the ON and OFF
set values and the
Hysteresis width.
NOTE: The above charts show a ‘Normally Open’ configuration. Reverse them for a ‘Normally Closed’ configuration.
This is the ideal programming
mode if you have a target
pressure. Enter the target
pressure and the ON and OFF
points are set
automatically. The
only other things
you have to set are
the Window and
Hysteresis widths.
•Small size
•PSI models with 2 pressure ranges
•1-touch programming for upper and lower limits
•Hysteresis mode (ideal for detection applications)
•Window modes (ideal for maintaining a pressure range)
•Digital and analog outputs
•NPN or PNP output types
•Manual or Automatic programming
•User defined normally open or normally closed
configuration
•3 different pressure ranges
Hysteresis Width
Pressure Value
OFF
Point
OFF
ON
Output
Teach 1 Teach 2
ON
Point
Midpoint between
Teach 1 & Teach 2
Using actual objectUsing actual object
Normally Open
This method automatically sets
the essential parameters based
on production
values. Use an
actual object to
teach the ON
and OFF points,
and the mid-
point will be
automatically
set.
Hysteresis Width
Pressure Value
Normally Open
OFF
ON
Output
OFF Set Value ON Set Value
If you know the exact
pressure settings of
your application,
simply enter the ON
and OFF set values.
The Hysteresis width
is automatically set.
Manual Hysteresis Mode 2-Point Auto-Teaching Hysteresis Mode
1-Point Auto-Teaching Window Mode
Manual Window Mode