CSM_E3X-DA-S_MDA_DS_E_3_1 E3X-DA-S Digital Fiber Sensors Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application Evolution and Perfection The next-generation platform for a wide range of sensing The industry's first Power Tuning Function in a digital sensor. Large, Easy-to-Read Displays that are clear even from a distance. Seven convenient display formats. Stable long-term performance achieved with OMRON's Auto Power Control (APC) function. A wide array of Advanced Functions for even more applications. The same Ease-of-Use as the E3X-DA-N Amplifier. Environmentally Friendly design. Improved Mobile Console. 2 3 Industry's First Power Tuning Function in a Digital Sensor. No complicated mode settings. Large, bright operation indicator (like earlier models) Patent Pending Troublesome power adjustments have been eliminated, so it isn't necessary to select from power mode settings, such as long-distance mode, standard mode, and short-distance mode. When the MODE Key is pressed once, the power tuning function shifts the power level so that the present incident level is set to the ideal level (2000 on the digital display.) Earlier Method Large, Easy-to-Read Displays: Clear Even from a Distance The displays are large and easy-to-read, despite the small case. Incident insufficient Short-distance mode Appropriate Standard mode Appropriate Long-distance mode Saturated Super-long-distance mode Saturated Threshold level RUN mode New Method Incident level Threshold level High-speed mode Incident level Press Up to 5-fold increase No power modes Industry's largest characters: 6 mm (like earlier models) Settings can be made more simply and confidently with two digital displays. For example, the threshold value can be changed while reading the incident level or a setting can be changed while confirming the setting's function item number. Function Power tuning indicator added to indicate setting status. Setting Up to 1/25 reduction SET mode The Sensor can be used immediately without setting the mode. If the incident light level is too high or too low, just press the Mode key to achieve the optimum status. The best mode for each application was selected from several power modes. Function numbers added to function items. Settings are now reversible. Insufficient light or saturation at short distances can be corrected. The power tuning range is extended to the allowable limits to eliminate problems such as insufficient light or detection failures due to saturation. If the installation distance is too short, the incident light may saturate (i.e., to a digital incident level of 4,000), preventing detection. The power can be tuned down to 1/25th of the default setting for stable detection even at close range. Seven Convenient Display Formats Patent Pending Press An incident level/threshold display, percentage/threshold display, and large bar graph display have been added, so you can select the best display method for the application. Without workpiece Transparent workpiece With workpiece Incident level does not change. Incident level changes. Incident Level/Threshold Display Large Bar Graph Display Percentage/Threshold Display Incident light Detection is not possible Detection is possible. Incident level Threshold level Change the threshold level while reading the incident level. Variations between different Sensors can be eliminated. Threshold levels had to be set and maintained separately for individual Sensors due to variations in the digital light levels measured by each Sensor. With power tuning, the incident level can be fine-tuned so the same threshold level can be set for each Sensor in an application. Maintenance is also simplified because it is easier to recognize measurement levels that have shifted during operation. Earlier Method Incident level Threshold level Verify the difference between the incident level and threshold level while setting the threshold level. Incident Level/Peak Hold Display No incident light Bar display Check the incident level intuitively. Ideal when it is better to view an analog display instead of the actual digital level. Peak Hold/Bottom Hold Display 2055 2010 Press New Method Incident level Peak hold Threshold level 1350 Detecting missing tablets 4 Digital light levels vary due to individual differences in the Sensors, so the threshold levels must be set individually. All of the Amplifiers are set to the same digital light level, so the same threshold level can be set and maintained for the Sensors. Simultaneously display the peak hold level and present incident level. The optical axis can be adjusted more easily and surely by checking the peak hold level while adjusting the optical axis. 1280 Display the peak level when light was brightest and bottom level when light was dimmest. The digital levels of high-speed objects can be read precisely. (Refreshing the hold level was changed from a fixed time to synchronizing with the output, so the peak and bottom hold values can be checked with certainty.) 5 Stable, Long-term Performance with OMRON's APC Function Many Advanced Functions for Even More Applications Fastest in the Industry OMRON provides the industry's most stable long-term detection by using new 4-element LEDs and an APC (Auto Power Control) circuit. Detecting Leads on Electronic Parts Highest Level of Stability In addition to our unique APC circuit used in the E3X-DA-N Amplifiers to compensate for the deterioration of the LED, the E3X-DA-S uses 4-element LEDs to counteract the deterioration of the light-emitting elements over time and achieve the industry's most stable long-term detection performance. Furthermore, the circuit is designed with excess light capacity, so the Sensors can be used with high stability regardless of whether the APC circuit is ON or OFF. Provides high-speed response for miniature workpieces, such as chip parts and devices with short tact times. New Method Earlier Method Incident level 4-element LED and APC Incident level 3-element LED and APC Three kinds of timer functions are supported. The timers can be set between 1 ms and 5 s. A one-shot timer is supported in addition to the ON-delay and OFF-delay timers. The Amplifier's ON time can be fixed, which is useful during high-speed workpiece detection. Long-term stability Discriminating Tablet Lengths Without APC circuit Without APC circuit Time Time Compensate for the effects of contaminants and temperature variation with differential operation mode. (Advanced Models) Area output function can be used for range judgement. (Advanced Twin-output Models) Operations that required multiple Sensors, such as height measurement, can be performed with just one Sensor. Two threshold levels can be set to easily output within-range and out-of-range outputs. Area output Incident level 2000 Threshold 1 1000 Threshold 2 Time Output ON OFF This operation mode uses a special OMRON algorithm to compensate for slight light level changes due to dirt or temperature variations and detect only the light level changes due to the workpiece. Detecting Seals Remote input function can control the Sensor remotely. (Advanced External-input Models) Slight light level changes can be detected with stability and precision, eliminating the need for time-consuming manual adjustments for light level changes. With the Twin-output Amplifiers, output 2 can function as an alarm output (light level operation) to indicate when the light level has changed due to dirt or other causes. Patent Pending Judges light level changes by comparing the incident level and threshold level. Judges light level changes by comparing the incident level to a time-averaged incident level. Threshold level (absolute value) Incorrect operation due to light level change Incident level Differential Operation Incident level Light Level Operation (Normal Operation) Alarm output Detecting marks in a dusty environment Input signals can make various remote settings, such as teaching operations, power tuning, and emitter OFF. This model is ideal for diverse needs, such as checking Sensor operation remotely before operation or making settings remotely because teaching has to be performed often for frequent workpiece model changes. The counter function can output signal after counter Patent Pending counts up or down. Counter Function (Advanced External-input Models) Down Counter Up Counter Detecting knots in thread A counter function is built-in, so the number of workpieces can be counted without a separate counter or small PLC that used to be required. Incident level Incident level Threshold level Time Counter Alarm output threshold The light level varies due to dirt, temperature variations, or other environmental factors. Incorrect operation 6 Time Counter Counter value Light level difference (absolute value) Time Time Detecting Chip Components Time Time Detecting differences in the light level enables setting more subtle light level differences. Minute changes are detected reliably. Output when count reaches SV. Output when count reaches 0. 7 The Same Ease-of-Use as the E3X-DA-N Up to 16 Amplifiers can be connected. Connector models Relay connectors not required. Patent Pending Japan patent number 3266198 In Amplifiers with Connectors, the power supply is distributed to slave connectors through a single master connector. This design has three major advantages. Prewired models Power is supplied from the master Amplifier Unit to the slave Amplifier Units through the Master Connector. Separate power lines and output lines are required for each Amplifier. 7 cables Streamlined wiring Eliminate the installation time, cost, and space associated with relay connectors. Optical communications Power supply pin 1 Materials containing lead have been completely eliminated. The Fiber Sensor is the first in the industry to use environmentally friendly lead-free solder. Master connector First in the industry No lead! 15 cables Power line 1. Wiring time is significantly reduced. 2. Relay connectors are unnecessary, so wiring takes up less space. 3. Storage and maintenance are simpler because it isn't necessary to distinguish between master connector and slave connectors on the Amplifier. Environmentally friendly features are essential in truly high-performance products. Reduced Power Wiring Saves Space Power line Output lines only Simplified Connector Design Output lines only The E3X-DA-S uses OMRON's own simplified wiring connectors that were introduced with the E3X-DA-N. Environmentally Friendly Design Relay connectors Slave connector Optical communications prevents mutual interference. Pb This ECO label is indicated on produts that meet the environmental standards established by OMRON. Mutual interference is prevented with optical communications, so up to 10 Amplifiers can be mounted together. (The number of Amplifiers depends on the operating conditions.) Optical communications Close-mounting of up to 10 Sensors Zero reset function immediately resets the digital display to 0. With Workpiece 2 Up to 10 Amplifiers The digital display can be turned OFF or dimmed during operation. Eco-mode When the digital display is viewed infrequently during operation, current consumption can be reduced by dimming the display or turning it OFF entirely. The display will light up again automatically when an operation key is touched. (Ecomode can be set from the Mobile Console only.) Without Workpiece Patent Pending Japan patent number 3255229 The zero reset function can immediately reset the digital display to 0 at any time. By setting the reference value to 0, the threshold value can be set while monitoring differences in incident light levels. The threshold value will also shift simultaneously when the zero reset button is pressed. Shift Incident level difference = 700 Threshold level set to 350. Display not lit. Lights up if an operation is performed. Dimmed display During operation (After 30 s without an operation) Lights up if an operation is performed. During operation (After 30 s without an operation) Zero reset Display reset to 0. 3 Cable disposal is not required during maintenance. In addition to saving space and reducing wiring time, the new connector design eliminates the need to dispose of cables together with the Amplifiers. Reversible Digital Display (Reverse Mode) The digital display can be reversed to match the Amplifier's mounting direction. Standard mode Selectable Cable disposal is not necessary. Reverse mode 8 9 Further Improvements to the Mobile Console Retains all of the Previous Advantages of the Mobile Console. New and Improved Fiber Sensor and Mobile Console. Can also be used with Photoelectric Sensors with Separate Digital Amplifiers. Settings, teaching, and fine-tuning can be performed at the fiber tip. The Mobile Console can be used for settings and teaching at the tip of the fiber. Difficult adjustments can be made while checking the workpiece position. Even if the Amplifier and Sensor head are separated during operation, it is still possible to flash the Sensor head and display the amplifier channels. E3X-DA-S Digital Fiber Sensor Channel 5 Channel 4 Channel 3 Channel 2 Channel 1 E3C-LDA Photoelectric Sensor with Separate Digital Amplifier E3X-MC-S Mobile Console Easily set multiple Sensors. Group Power Tuning With the group power tuning function, power tuning is possible for multiple Sensors at the same time. With Group Teaching, Teach Multiple Amplifiers Simultaneously. Group teaching The tedious teaching that had to be performed separately for each Amplifier can now be performed for several Amplifiers at once using the Mobile Console. Copying Settings within the Same Group Copy channel 1's contents to all channels. Channel 1 Channel 1 All channels Channel 2 Channel 5 Settings such as mode or threshold settings in an Amplifier or bank can be copied to all of the Amplifiers in the same group. Group Power Tuning The Age of Usercustomizable Sensors. Improved Mode Lock Function Settings can be customized for different applications by locking out unnecessary function blocks within function settings. Copying Settings to Other Groups Function Block Application Set for manual operation. Manual All of the group's settings are copied. Machine A Machine B Manual setting Teaching Function setting Operation OK Locked Locked The settings for a group of Amplifiers on one machine can be copied to a group of Amplifiers on another machine. (The settings can also be copied to and from banks.) Machine D Set for teaching operation. Teaching Teaching 10 + Manual Set for teaching + manual operation. Locked Operation OK Locked Operation OK Operation OK Locked 11 OMRON Corporation Industrial Automation Company Application Sensors Division Sensing Devices and Components Division H.Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7068/Fax: (81)75-344-7107 Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit, Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49)7032-811-0/Fax: (49)7032-811-199 OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 OMRON ASIA PACIFIC PTE. LTD. 83 Clemenceau Avenue, #11-01, UE Square, 239920 Singapore Tel: (65)6835-3011/Fax: (65)6835-2711 OMRON CHINA CO., LTD. BEIJING OFFICE Room 1028, Office Building, Beijing Capital Times Square, No. 88 West Chang'an Road, Beijing, 100031 China Tel: (86)10-8391-3005/Fax: (86)10-8391-3688 In the interest of product improvement, specifications are subject to change without notice. Authorized Distributor: This document provides information mainly for selecting suitable models. Please read the Instruction Sheet carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. CSM_E3X-DA-S_MDA_DS_E_3_1 CSM_E3X-DA-S_MDA_DS_E_3_1 E3X-MDA Super Dual Fiber Sensor Bringing a new dimension to sensing... This document provides information mainly for selecting suitable models. Please read the Instruction Sheet carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. OMRON Corporation Regional Headquarters Industrial Automation Company OMRON EUROPE B.V. Sensor Business Unit, Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49)7032-811-0/Fax: (49)7032-811-199 Sensing Devices Division H.Q. Industrial Sensors Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7022 Fax: (81)75-344-7107 Authorized Distributor: OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 OMRON ASIA PACIFIC PTE. LTD. 83 Clemenceau Avenue, #11-01, UE Square, 239920 Singapore Tel: (65)6835-3011/Fax: (65)6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Road (M), Shanghai, 200120 China Tel: (86)21-5037-2222/Fax: (86)21-5037-2200 CSM_E3X-DA-S_MDA_DS_E_3_1 In the interest of product improvement, specifications are subject to change without notice. ...the 2-channel amplifier has arrived. Having problems gang-mounting Fiber Sensor Amplifier Units in tight spaces? Slimmest in the industry -- 5 mm per channel. Two Amplifiers squeezed into a body of width 10 mm. Remarkable space saving of approx. 50%. Power saving of approx. 40%. Patent pending Checking alignment and mounting of LCD substrates (Savings per channel compared with existing products.) 100 mm 10 2 ch 1 ch mm Emitting Receiving Emitting Receiving Equipped with AND/OR control output. Patent pending Two types of control output possible with one Sensor (AND/OR). Compact PLCs and Sensor Controllers no longer required. Detection and front/back discrimination of parts Half the Space Detection of bends in electronic component leads Compact PLC or Sensor Controller Operation indicator Incident level Channel 1 display AND/OR Operation indicator Incident level AND/OR Channel 2 display Flexible control with Mobile Console. The Mobile Console, which can also be used with the E3X-DA-S, allows handheld operation of the Fiber Head even when it is separated from the Amplifier. 50 mm An impressive lineup of Digital Amplifiers to handle a wide variety of applications. A host of remarkable functions inside a compact body. A complete lineup of Sensor Heads to handle an even wider range of applications. This is the platform for OMRON's sensing technology. The Digital Amplifiers achieve a maximum response time of 48 s. Standard Models Models with Cables (E3X-DA11-S) Models with Connectors (E3X-DA6-S) Equipped with OMRON's own easy-wiring connector. Laser-type Smart Sensors ZX-L Series Linear Platform Inductive Displacement Smart Sensors ZX-E Series High-resolution sensing using laser and magnetic technology Advanced Models (Representative model: E3X-DA6TW-S) Twin-output Models Two threshold values can be set. Judgement and self-diagnosis output available. External-input Models The Sensor can be controlled externally. Equipped with counting function. (Representative model: E3X-DA6RM-S) Smart Monitor A wide variety of color variations available. Equipped with APC circuit for more stable detection. An improved lineup for smarter sensing Mark-detecting Models and Infrared Models Models with Green LED Models with Blue LED (Representative model: E3X-DAG6-S) (Representative model:E3X-DAB6-S) Digital Fiber Sensors E3X-DA-S/MDA Series ON/OFF Platform Infrared Models NEW A lineup of Smart Sensors that use the eddy current method Available Soon (Representative model:E3X-DAH6-S) Laser-type Photoelectric Sensors with Separate Amplifiers E3C-LDA Series A common platform for Fiber Sensors and Sensors with Separate Amplifiers Two Amplifiers squeezed into a single, compact Unit. AND/OR output available. 2-channel Models (Representative model:E3X-MDA6) Mobile Console Maximize Fiber Amplifier potential using remote setting, copying, and other functionality. Refinement and a new dimension that goes beyond superior performance. Mobile Console (E3X-MC11-S) Photoelectric Sensors with Separate Digital Amplifiers have joined the Smart Sensor family. CSM_E3X-DA-S_MDA_DS_E_3_1 New Models That Counteract the Decline in Operating Rates Caused by Dust and Dirt Advanced ATC Models Active Threshold Control (ATC) Automatically adjusts the threshold value. ATC Error Output (Selectable Function) Digital Laser Sensors E3C-LDA@AT Provides an error output when ATC does not adjust the threshold value. Alarm Output (Selectable Function) Provides an alarm when maintenance is required. Digital Fiber Sensors E3X-DA@AT-S Glass substrate detection though view ports Chip component detection Technology Intelligently Solve Problems Onsite with The Sensing ATC Function A unique OMRON algorithm has been used that can determine whether changes have been caused by dust and dirt or by differences in workpieces. The threshold value is automatically adjusted by the Sensor according to changes to increase equipment operating rates by reducing sensing errors. This is particularly true in applications requiring high-precision detection. Fixed Threshold Value (Previous Models) 2000 1800 An absolute value is set for the threshold. Digital incident level Engine for High-performance OMRON's many years of accumulated sensing technology and highspeed digital processing techniques merge to meet onsite needs. Our goal is high-performance sensing that provides easy, reliable application. Reliable Detection of Small Workpieces 12-bit A/D converter (4,000 resolution), high-speed response of 48 s (Fiber Sensors) Fine Sensing Adjustment is required for sensing errors. Automatic Compensation for External Changes Active Threshold Control (ATC) Consistent Emitter Power Auto Power Control (APC) Time ON Output OFF Sensing Engine High Performance Active Threshold Control (ATC Models) 2000 -10% Digital incident level A relative value is set for the threshold. The value of the threshold is adjusted every 30 s (see note) to prevent sensing errors. Time ON Output OFF The monitoring range is set in the Sensor according to the threshold value. The threshold value is adjusted according to changes within this range. Easy Operation Easy-to-read Displays Even at a Distance Intelligent Display Eliminates the Need for Distance Mode Settings Power Tuning Ordering Information Digital Fiber Sensor Type Appearance Model Functions Pre-wired Models ATC NPN output PNP output E3X-DA11AT-S E3X-DA41AT-S E3X-DA6AT-S E3X-DA8AT-S ATC error output Alarm output Connector Models Separate Digital Amplifier Laser Sensors Type Appearance Pre-wired Models Model Functions NPN output ATC PNP output E3C-LDA11AT E3C-LDA41AT E3C-LDA6AT E3C-LDA8AT ATC error output Alarm output Connector Models Ratings and Specifications Model Digital Fiber Sensors Separate Digital Amplifier Laser Sensors NPN output E3X-DA11AT-S E3X-DA6AT-S E3C-LDA11AT E3C-LDA6AT PNP output E3X-DA41AT-S E3X-DA8AT-S E3C-LDA41AT E3C-LDA8AT Type Item Super-high-speed mode High-speed mode Response Standard mode time Operate or Reset: 80 s Operate or Reset: 100 s Operate or Reset: 250 s Operate or Reset: 250 s Operate or Reset: 1 ms High-resolution mode Operate or Reset: 4 ms ATC Active threshold control (used for output 1) Functions I/O settings Startup operation The signal that is output can be selected (used for output 2): ATC error output The operation when power is turned ON can be selected: No operation, PT, or PT + ATC Note: Basic performance is the same as the Advanced Twin-output Sensors. Refer to E3C-LDA Datasheet (E338) and E3X-DA-S Datasheet (E336) for details. Only differences from the Advanced Twin-output Sensors have been given above. This document provides information mainly for selecting suitable models. Please read the Instruction Sheet carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 Authorized Distributor: Application Sensors Division Sensing Devices and Components Division H.Q. Shiokoji Horikawa, Shimogyo-ku, OMRON ASIA PACIFIC PTE. LTD. Kyoto, 600-8530 Japan 83 Clemenceau Avenue, Tel: (81)75-344-7068/Fax: (81)75-344-7107 #11-01, UE Square, 239920 Singapore Regional Headquarters Tel: (65)6835-3011/Fax: (65)6835-2711 OMRON EUROPE B.V. OMRON CHINA CO., LTD. BEIJING OFFICE Sensor Business Unit, Room 1028, Office Building, Carl-Benz-Str. 4, D-71154 Nufringen, Beijing Capital Times Square, Germany No. 88 West Chang'an Road, Tel: (49)7032-811-0/Fax: (49)7032-811-199 Beijing, 100031 China Tel: (86)10-8391-3005/Fax: (86)10-8391-3688 Note: Specifications subject to change without notice. CSM_E3X-DA-S_MDA_DS_E_3_1 CSM_E3X-DA-S_MDA_DS_E_3_1 New Models That Eliminate Worries about Digital Sensor Setting Mistakes Limited-function Models: Simple and Easy Easy and Reliable Digital Sensors with the Same Detection Performance as Previous Models One-key, one-operation concept for easy operation. Threshold value setting with direct operation performed while monitoring the detection status. Digital Fiber Sensors E3X-DA@SE-S Lock function to prevent operating errors through unintentional operation. Technology The Simplest Digital Fiber Sensor The Sensing Some people think that digital sensors with their advanced performance are difficult to use, so we went back to the drawing board to rethink performance and functions. Without changing basic functions like APC and digital displays, OMRON created a Digital Fiber Sensor that can be used as easily as the familiar sensors with sensitivity adjustment knobs. OMRON's many years of accumulated sensing technology and highspeed digital processing techniques merge to meet onsite needs. Our goal is high-performance sensing that provides easy, reliable application. Engine for High-performance Reliable Detection of Small Workpieces 12-bit A/D converter (4,000 resolution) UP/DOWN Key Threshold adjustment Incident level Fine Sensing Consistent Emitter Power Auto Power Control (APC) Threshold value High Performance Sensing Engine KEY LOCK Switch OPERATION MODE Selector TEACH Key Threshold Teaching With/Without Workpiece: Teaching is performed in two states. Automatic: Teaching is performed by passing a workpiece. Easy Operation Easy-to-read Displays Even at a Distance Intelligent Display One Key, One Operation Simple and easy direct operation Ordering Information Type Model Appearance NPN output PNP output Pre-wired Models E3X-DA11SE-S E3X-DA41SE-S Connector Models E3X-DA6SE-S E3X-DA8SE-S Ratings and Specifications Model Digital Fiber Sensor NPN output E3X-DA11SE-S E3X-DA6SE-S PNP output E3X-DA41SE-S E3X-DA8SE-S Type Item Light source (wavelength) Red LED (650 nm) Power supply voltage 12 to 24 VDC 10%, ripple (p-p): 10% max. Power consumption 960 mW max. (Power supply: 24 V, Current consumption: 40 mA max.) Control output Load power supply: 26.4 VDC max., Open-collector output, Load current: 50 mA max. (Residual voltage: 1 V max.) Protection circuits Power supply reverse polarity protection, Output short-circuit protection Response time Operate or Reset: 1 ms Sensitivity setting Teaching or manual adjustment Auto power High-speed control method for emission current control Functions Mutual interference Optical communications sync, possible for up to 10 Units prevention Indicators Operation indicator (orange) Digital displays Twin digital displays (incident level + threshold) Note: Basic performance is the same as the E3X-DA-S Series. Refer to the E3X-DA-S Datasheet (E336) for details. This document provides information mainly for selecting suitable models. Please read the Instruction Sheet carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 Authorized Distributor: Application Sensors Division Sensing Devices and Components Division H.Q. Shiokoji Horikawa, Shimogyo-ku, OMRON ASIA PACIFIC PTE. LTD. Kyoto, 600-8530 Japan 83 Clemenceau Avenue, Tel: (81)75-344-7068/Fax: (81)75-344-7107 #11-01, UE Square, 239920 Singapore Regional Headquarters Tel: (65)6835-3011/Fax: (65)6835-2711 OMRON EUROPE B.V. OMRON CHINA CO., LTD. BEIJING OFFICE Sensor Business Unit, Room 1028, Office Building, Carl-Benz-Str. 4, D-71154 Nufringen, Beijing Capital Times Square, Germany No. 88 West Chang'an Road, Tel: (49)7032-811-0/Fax: (49)7032-811-199 Beijing, 100031 China Tel: (86)10-8391-3005/Fax: (86)10-8391-3688 Note: Specifications subject to change without notice. CSM_E3X-DA-S_MDA_DS_E_3_1 Digital Fiber Sensors E3X-DA-S/MDA CSM_E3X-DA-S_MDA_DS_E_3_1 OMRON's Next-generation Platform for a Wide Range of Detection * Features a Power Tuning function that optimizes light reception at the press of a button. * Combines newly developed 4-element LEDs with an APC circuit to ensure stable, long-term LED performance. * Utilizes OMRON's innovative wire-saving connector. * 2-channel models achieve the thinnest profile in the industry, at only 5 mm per channel. * 2-channel models also offer AND/OR control output. Be sure to read Safety Precautions on page 15. Features Equipped with an Industry's First Power Tuning (Optimum Light Setting) Function The E3X-DA-S/MDA features a Power Tuning function that optimizes power at the press of a button. This function easily but securely resolves saturation due to short sensing distances or insufficient incident light due to long sensing distances. In addition, the response speed does not change as mode selection has tuned the power. New proposal Conventional Incident level Threshold High-speed mode Incident level Low Short-range mode Appropriate Standard mode Appropriate Long-range mode Saturation Super-long-range mode Saturation Up to approx. 5 times Press Modeless Up to approx. 1/25 times Available without mode setting. Press the MODE key once to adjust high or low incident levels to be appropriate. Selected from various power mode according to applications Adoption of Newly Developed 4-Element LEDs and an APC (Auto Power Control) Circuit Achieves Long-term Reliable Detection at the Highest Level in the Industry Newly developed 3-element LEDs + APC 4-element LEDs + APC Incident level Conventional Incident level The long-term reliable detection at the highest level in the industry is achieved with the innovative APC circuit whose performance is proved by E3X-DA-N series and the newly developed high-power LEDs (4-element type) to ensure super stable, long-term LED performance. Stable performance is always available without the ON/OFF setting of an APC circuit. Long-term stability No APC circuit No APC circuit Time Time OMRON's Innovative Wire-saving Connector Inherited from the E3X-DA-N Wire-saving Connector Model Reduced Wiring and Space Requirements for Power Lines Up to 16 amplifier units connectable No relay connector required Clear Optical communications Power supply pin Master connector Slave connector The power is supplied from a master unit to slave units via a master connector. 7 lines Relay connector installation work, cost and space are saved. Output lines Amplifier units with cables Power line Only output lines 1. Greatly reduced wiring work 2. Improved space usability due to the unnecessity of relay connectors 3. Simple stock management due to the unnecessity of distinction between master and slave for amplifiers Amplifier units with connectors Power and output lines are required respectively. 15 lines Power lines The amplifier units with connectors supply the power to slave connectors via a master connector. This offers three following advantages. Relay connector 1 E3X-DA-S/MDA Models available for a wide variety of applications at manufacturing sites Industry Leading Two Amplifiers Loaded in a Small Body . . . . 2-channel models Two amplifiers are loaded in a 10 mm-wide body. Space usability can be approximately doubled. In addition, approximately 40% of the energy can be saved. (compared to the value per channel of the former model) Liquid crystal board installation and alignment check 20mm Simpler Digital Fiber Sensors 10mm 2-channel models E3X-MDA . . . . Simple & Easy Single-function Models UP/DOWN keys Threshold value adjustment Current value Threshold value Required performance and functions have been reviewed from basic points to improve high-performance but hard-to-use digital models. Digital fiber sensors, used in the sense as if using volume type sensors, are added to the basic functions such as an APC function and digital display. Key lock switch Operation mode selection switch TEACH key Threshold value teaching Yes/No: Teaching at two points to be detected Automatic: Automatic teaching by feeding workpieces High-speed and High-resolution Analog Output Supports Wide Variety of Applications . . . .Advanced Analog Output Models Analog Control Output High-speed and High Resolution The voltage in the range of 1 to 5 V is output according to the incident level (digital display). Wide variety of applications is possible including positioning control or difference detection with multiple levels. Detection modes can be switched in accordance with applications. High-speed response of 80 s (super-high-speed mode) supports the positioning controls that require high-speed control. Sheet Displacement ON/OFF Analog Area Output Function Area Judgment Is Possible . . . .Advanced, Twin-output Models Only one sensor is enough for area judgment for height or others that has required multiple sensors. Setting two threshold values allows easy output inside and outside range. Area Output Tablet length detection Incident level 2000 Threshold value 1 1000 Threshold value 2 Time Output ON OFF Remote Input Function Sensors Controlled from Outside . . . .Advanced, External- Sticker detection input Models Remote settings for teaching/power tuning/light OFF are possible with input signals. The remote input function meets the diversifying demands such as remote settings made for frequent teaching due to level change corresponding to workpiece change or remote operation check of sensors before operation. Equipped with an Industry's First ATC Function that Resolves Problems at Manufacturing Sites . . . .Advanced ATC Models OMRON's unique algorithm is equipped to Fixed Threshold Value Method (Conventional Models) Corrected Threshold Value Method (ATC Models) distinguish dust or dirt and the change of Threshold value 2000 2000 -10% 1800 set as a relative workpieces. Automatic correction of threshold Threshold value value set as an values by sensors in accordance with changes Incident level Incident level absolute value (digital value) (digital value) prevents malfunctions and improves the Threshold value is corrected every 30 seconds * operating rates of machines. The ATC function Malfunctions are prevented Malfunction Adjustment is required is especially effective for the applications that Time Time require high-resolution detection. ON ON Output Output OFF OFF * Monitoring range is defined in sensors according to threshold values. Threshold values are corrected in this definition range. 2 E3X-DA-S/MDA Ordering Information Amplifier Units Amplifier Units with Cables (2 m) [Refer to Dimensions on page 17.] Item Appearance Model Functions Single-function models NPN output --- Standard models Green LED Mark-detecting models Blue LED (multiple color light sources) Infrared LED Advanced models Timer, Response speed change PNP output E3X-DA11SE-S 2M E3X-DA41SE-S 2M E3X-DA11-S 2M E3X-DAG11-S 2M E3X-DAB11-S 2M E3X-DAH11-S 2M E3X-DA41-S 2M E3X-DAG41-S 2M E3X-DAB41-S 2M E3X-DAH41-S 2M External-input models Remote setting, counter, differential oper- E3X-DA11RM-S 2M ation E3X-DA41RM-S 2M Twin-output models Area output, self-diagnosis, differential operation E3X-DA11TW-S 2M E3X-DA41TW-S 2M ATC function models ATC (Threshold value automatic correction) E3X-DA11AT-S 2M E3X-DA41AT-S 2M Analog output models Analog output models E3X-DA11AN-S 2M E3X-DA41AN-S 2M AND/OR output E3X-MDA11 2M E3X-MDA41 2M 2-channel models Amplifier Units with Connectors Item Appearance Single-function models Standard models --- Green LED Mark-detecting models (multiple color light sources) Blue LED Infrared LED Advanced models Model Functions Timer, Response speed change NPN output E3X-DA6SE-S E3X-DA6-S E3X-DAG6-S E3X-DAB6-S E3X-DAH6-S PNP output E3X-DA8SE-S E3X-DA8-S E3X-DAG8-S E3X-DAB8-S E3X-DAH8-S External-input models Remote setting, counter, differential operation E3X-DA6RM-S E3X-DA8RM-S Twin-output models Area output, self-diagnosis, differential operation E3X-DA6TW-S E3X-DA8TW-S ATC function models ATC (Threshold value automatic correction) E3X-DA6AT-S E3X-DA8AT-S AND/OR output E3X-MDA6 E3X-MDA8 2-channel models Ratings and Specifications Control output/input Light source Single-function models Standard models Markdetecting models Advanced models E3X-DA@G-S 3X-DA@B-S E3X-DA@H-S Twin-output models External-input models ATC function models ON/OFF output Input Analog output Power tuning Timer --- --- Functions InterferDifferenence pretial detecvention tion counter ATC Red LED 1 ms 50 s to 4 ms Only main --- --- --- --- --- Green LED Blue LED Infrared LED 50 s to 4 ms Only main --- --- --- --- --- Only main Red LED 50 s to 4 ms 80 s to 4 ms 130 s to 4 ms 80 s to 4 ms Analog output 2-channel models Response time Red LED 130 s to 4 ms Main + sub (2 lines) Only main Main + main (2 independent lines) (1 line) ----- --- --(1 line) --- --- --- --- --- --- --- 3 E3X-DA-S/MDA Amplifier Unit Connectors (Order Separately) Note: Protector seals are provided as accessories. [Refer to Dimensions on page 19.] Item Cable length Appearance No. of conductors Model 3 E3X-CN11 4 E3X-CN21 1 E3X-CN12 2 E3X-CN22 Master Connector 2m Slave Connector Combining Amplifier Units and Connectors Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order. Amplifier Unit Model NPN output Single-function models E3X-DA6SE-S Standard models E3X-DA6-S E3X-DAG6-S Mark-detecting models (multiple color light E3X-DAB6-S sources) E3X-DAH6-S Advanced models 2-channel models Applicable Connector (Order Separately) Master Connector Slave Connector PNP output E3X-DA8SE-S E3X-DA8-S E3X-DAG8-S + E3X-CN11 E3X-CN12 E3X-CN21 E3X-CN22 E3X-DAB8-S E3X-DAH8-S E3X-DA6TW-S E3X-DA6RM-S E3X-DA6AT-S E3X-MDA6 E3X-DA8TW-S E3X-DA8RM-S E3X-DA8AT-S E3X-MDA8 When Using 5 Amplifier Units Amplifier Units (5 Units) Mobile Console (Order Separately) Appearance + 1 Master Connector + 4 Slave Connectors [Refer to Dimensions on page 20.] Model Remarks E3X-MC11-SV2 (model number of set) Mobile Console with Head, Cable, and AC adapter provided as accessories E3X-MC11-C1-SV2 Mobile Console E3X-MC11-H1 Head E39-Z12-1 Cable (1.5 m) Note: Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S/MDA-series Amplifier Units. The E3X-MC11-SV2 is an upgraded version of the E3X-MC11-S that is fully interchangeable with the older model. Accessories (Order Separately) Mounting Bracket [Refer to E39-L/F39-L/E39-S/E39-R.] Appearance Model E39-L143 Quantity 1 End Plate [Refer to PFP-@.] Appearance Model PFP-M Quantity 1 4 E3X-DA-S/MDA Ratings and Specifications Refer to pages 17 to 20 for dimensions. Amplifier Units Item Type Single-function models Standard models Model E3X-DA@SE-S E3X-DA@-S Mark-detecting models (multiple color light sources) Green LED Blue LED Infrared LED E3X-DAG@-S E3X-DAB@-S E3X-DAH@-S Infrared LED Green LED (525 nm) Blue LED (470 nm) (870nm) Light source (wavelength) Red LED (635 nm) Power supply voltage Power consumption 12 to 24 VDC 10%, ripple (p-p) 10% max. 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) Load power supply voltage: 26.4 VDC; NPN/PNP open collector; load current: 50 mA max.; residual voltage: 1 V max. Reverse polarity for power supply connection, output short-circuit Control output Protection circuits Super-highspeed mode High-speed Remode sponse time Standard mode High-resolution mode Sensitivity setting Power tuning Timer function --- Operate: 48 s, reset: 50 s *1, *2 --- Operate/reset: 250 s Operate or reset: 1 ms --- Operate or reset: 4 ms Teaching or manual method --Light emission power and reception gain, digital control method Select from OFF-delay, ON-delay, or one-shot timer. --1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments) Automatic power High-speed control method for emission current control (APC) Zero-reset --Negative values can be displayed. (Threshold value is shifted.) Initial reset Settings can be returned to defaults as required. Mutual interferPossible for up to 10 Units *3 ence prevention Operation indicator Display Operation indicator (orange), Power Tuning indicator (orange) (orange) incident level + Digital display Select from incident level + threshold or other 6 patterns threshold Display orientation --Switching between normal/reversed display is possible. Ambient illumination Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. (Receiver side) Functions Ambient temperature range Ambient humidity range Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight (packed state) Case Materials Cover Accessories Operating: Groups of 1 to 2 Amplifiers: -25C to 55C Groups of 3 to 10 Amplifiers: -25C to 50C Groups of 11 to 16 Amplifiers: -25C to 45C Storage: -30C to 70C (with no icing or condensation) Operating and storage: 35% to 85% (with no condensation) 20 M min. (at 500 VDC) 1,000 VAC at 50/60 Hz for 1 minute Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions Destruction: 500 m/s2, for 3 times each in X, Y and Z directions IEC 60529 IP50 (with Protective Cover attached) Pre-wired or amplifier unit connector Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g Polybutylene terephthalate (PBT) Polycarbonate (PC) Instruction manual *1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention and the Mobile Console will not function. *2. PNP output is as follows: Operate: 53 s, reset: 55 s. *3. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled. 5 E3X-DA-S/MDA Advanced models Type External input mod- Twin output mod- ATC function mod- Analog output mod- 2-channel models els els els els Item Model E3X-DA@RM-S E3X-DA@TW-S E3X-DA@AT-S E3X-DA@AN-S E3X-MDA@ Light source (wavelength) Red LED (635 nm) Power supply voltage 12 to 24 VDC 10%, ripple (p-p) 10% max. Power consumption 1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC) Load power supply voltage: 26.4 VDC; NPN/PNP open collector; ON/OFF output load current: 50 mA max.; residual voltage: 1 V max. Control output Voltage output: 1 to 5 VDC (Connection load 10 k min.) Temperature characteristics Con0.3%F.S./C trol Response speed/reoutput Analog output --peat accuracy --Super-high-speed mode: 80 s/1.5%F.S. High-speed mode: 250 s/1.5%F.S. Standard mode: 1 ms/1%F.S. High-resolution mode: 4 ms/0.75%F.S. Remote control input No-voltage input (contact/non-contact) *1 Protection circuits Reverse polarity for power supply connection, output short-circuit Super-highOperate: 48 s, Operate or reset: Operate or reset: Operate or reset: Operate or reset: speed mode reset: 50 s *2, *3, *4 80 s *2 130 s *2 80 s *2 130 s *2, *5 High-speed Operate or reset: ReOperate or reset: 250 s 450 s sponse mode time Standard mode Operate or reset: 1ms High-resolution Operate or reset: 4ms mode Sensitivity setting Teaching or manual method Power tuning Light emission power and reception gain, digital control method Switchable between single edge and double edge detection mode Differential deSingle edge: Can be set to 250 s, 500 s, 1 ms, 10 ms, or 100 ms. --tection Double edge: Can be set to 500 s, 1 ms, 2 ms, 20 ms, or 200 ms. Select from OFF-delay, ON-delay, or one-shot timer. Timer function 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments) Automatic powHigh-speed control method for emission current er control (APC) Functions Zero-reset Negative values can be displayed. (Threshold value is shifted.) Initial reset Settings can be returned to defaults as required. Mutual interferPossible for up to 9 Possible for up to 10 Units *6 ence prevention Units (18 channels) *7 Switchable between up counter and down Counter counter. --Set count: 0 to 9,999,999 *1. Input Specifications NPN PNP Contact input (relay or switch) ON: Shorted to 0 V (sourcing current: 1 mA max.). OFF: Open or shorted to Vcc. ON: Shorted to Vcc (sinking current: 3 mA max.). OFF: Open or shorted to 0 V. Non-contact input (transistor) ON: 1.5 V max. (sourcing current: 1 mA max.) OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.) ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.) OFF: 1.5 V max. (leakage current: 0.1 mA max.) *2. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention and the Mobile Console will not function. *3. PNP output is as follows: Operate: 53 s, reset: 55 s. *4. When counter is enabled: 80 s for operate and reset respectively. *5. When differential output is selected for the output setting, the second channel output is 200 s for operation and reset respectively. *6. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled. *7. Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled. 6 E3X-DA-S/MDA Type Item Functions External input models Model E3X-DA@RM-S External input setting (Select from teaching, power tunI/O setting ing, zero reset, light OFF, or counter reset.) Advanced models Twin-output mod- ATC function modAnalog output els els models E3X-DA@TW-S E3X-DA@AT-S E3X-DA@AN-S Output setting (SeOutput setting lect from channel 2 Analog output set(Select from channel output, area output, ting (offset voltage 2 output, area outself-diagnosis outadjustable) put, or self-diagnoput, or ATC error sis.) output) Display Operation indicator (orange), Power Operation indicator for channel 1 (orange), Tuning indicator (or- Operation indicator for channel 2 (orange) ange) Digital display Select from incident level + threshold or other 7 patterns Display orientation Ambient illumination (Receiver side) Ambient temperature range Ambient humidity range Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight (packed state) Case Materials Cover Accessories Select from incident level + threshold or other 6 patterns Model E3X-MDA@ Output setting (Select from channel 2 output, AND, OR, leading edge sync, falling edge sync, or differential output) Operation indicator for channel 1 (orange), Operation indicator for channel 2 (orange) Select from incident level for channel 1 + incident level for channel 2 or other 7 patterns Switching between normal/reversed display is possible. Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. Operating: Groups of 1 to 2 Amplifiers: -25C to 55C Groups of 3 to 10 Amplifiers: -25C to 50C Groups of 11 to 16 Amplifiers: -25C to 45C Storage: -30C to 70C (with no icing or condensation) Operating and storage: 35% to 85% (with no condensation) 20 M min. (at 500 VDC) 1,000 VAC at 50/60 Hz for 1 minute Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions Destruction: 500 m/s2, for 3 times each in X, Y and Z directions IEC 60529 IP50 (with Protective Cover attached) Pre-wired or amplifier unit connector Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g Polybutylene terephthalate (PBT) Polycarbonate (PC) Instruction manual Amplifier Unit Connectors Item Operation indicator (orange), Power Tuning indicator (orange) 2-channel models Mobile Console E3X-CN11/21/22 E3X-CN12 Item Model E3X-MC11-SV2 Rated current 2.5 A Rated voltage 50 V Applicable Sensors Contact resistance 20 m max. (20 mVDC max., 100 mA max.) (The figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) E3X-DA-S E3X-MDA E3C-LDA E2C-EDA Power supply voltage Charged with AC adapter No. of insertions Destruction: 50 times (The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent Connector.) Connection method Connected via adapter Polybutylene terephthalate (PBT) Weight Approx. 580 g (Console (packed state) only: 120 g) Mate- Housing rials Contacts Weight (packed state) Phosphor bronze/gold-plated nickel Approx. 55 g Approx. 25 g Refer to Instruction Manual provided with the Mobile Console for details. 7 E3X-DA-S/MDA Sensing Distance Through-beam Models (Unit: mm) Model Type Flexible (new standard) Standard models Standard Breakresistant Specialbeam models E32-T11R/E32-T12R/E32-T15XR/ E32-TC200BR(B4R) E32-T14LR/E32-T15YR/E32-T15ZR E32-T21R/E32-T22R/E32-T222R/ E32-T25XR/E32-TC200FR(F4R) E32-T24R/E32-T25YR/E32-T25ZR E32-TC200/E32-T12/E32-T15X/ E32-TC200B(B4) E32-T14L/E32-T15Y/E32-T15Z E32-TC200A E32-TC200E/E32-T22/E32-T222/ E32-T25X/E32-TC200F(F4) E32-T24/E32-T25Y/E32-T25Z E32-T11/E32-T12B/E32-T15XB E32-T21/E32-T221B/E32-T22B E32-T25XB Fluorine coating E32-T11U Longdistance, high power E32-T17L E32-TC200 + E39-F1 E32-T11R + E39-F1 E32-T11 + E39-F1 E32-T14 E32-T11L/E32-T12L E32-T11L + E39-F2 E32-T11R + E39-F2 E32-T11 + E39-F2 E32-T21L/E32-T22L Ultracompact, ultrafine sleeve E3X-DA@-S E3X-MDA@ Highresolution mode Standard mode Highspeed mode Superhighspeed mode Highresolution mode Standard mode Highspeed mode Superhighspeed mode 700 530 350 140 450 350 230 140 270 210 130 50 170 130 85 50 160 130 75 30 100 75 50 30 60 50 25 10 35 27 18 10 1,000 760 500 200 650 500 330 200 600 900 460 680 300 450 120 180 390 580 300 450 200 300 120 180 270 220 125 50 170 130 85 50 160 900 240 180 130 680 200 150 75 450 110 85 30 180 45 35 100 580 150 125 70 450 110 95 45 300 70 60 30 180 45 35 900 680 450 180 580 450 300 180 4,000 13,000 10,000 1,500 4,000 3,700 970 3,100 2,400 930 3,000 2,300 900 2,900 2,200 350 1,100 870 180 600 520 100 330 260 160 530 430 100 340 260 6,500 2,400 1,600 1,500 1,450 580 340 170 280 170 4,000 1,500 970 930 900 350 180 100 160 100 20,000*1 20,000*1 10,000 4,000*2 4,000*2 2,600 4,000*2 3,700 2,400 4,000*2 3,600 2,300 4,000*2 3,400 2,250 1,700 1,330 870 910 800 500 520 400 250 820 660 430 540 440 250 E32-T223R 160 130 75 30 110 85 55 30 E32-T33-S5 53 44 25 10 35 28 18 10 E32-T333-S5 12 10 6 4 8 6 5 4 E32-T334-S5 6 5 3 2 4 3 2 2 E32-T22S 2,500 1,900 1,250 500 1,600 1,250 830 500 E32-T24S 1,750 1,300 870 350 1,100 870 580 350 1,100 1,500 980 1,300 1,700 2,300 3,700 750 840 1,100 750 1,000 1,300 1,800 2,800 610 560 750 480 650 850 1,150 1,850 350 220 300 190 260 340 450 740 140 730 970 600 800 1,100 1,400 2,400 470 560 750 480 650 860 1,100 1,800 360 370 500 320 430 570 730 1,200 240 220 300 190 260 340 450 740 140 Fine beam E32-T16PR E32-T16P E32-T16JR E32-T16J Area sensing E32-T16WR E32-T16W E32-T16 E32-M21 *1. The optical fiber for the E32-T17L is 10 m long on each side, so the value is 20,000 mm *2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm. 8 E3X-DA-S/MDA Model Type Heatresistant Environment resistant models Chemical resistant Vacuum resistant E3X-DA@-S Highresolution mode 1,000 300 360 600 4,000 1,750 600 2,500 4,000* 500 1,800 920 260 1,350 210 660 630 E32-T51 E32-T54 E32-T81R-S E32-T61-S + E39-F2 E32-T61-S + E39-F1 E32-T84S-S E32-T61-S E32-T11F E32-T12F E32-T14F E32-T51F E32-T81F-S E32-T51V E32-T51V + E39-F1V E32-T54V E32-T54V + E39-F1V E32-T84SV Standard mode Highspeed mode 760 230 280 450 3,400 1,300 450 2,000 3,000 400 1,400 700 200 1,000 130 500 480 500 150 180 300 2,200 870 300 1,300 2,000 250 900 460 130 680 100 330 320 E3X-MDA@ Superhighspeed mode 200 60 70 120 900 350 120 520 800 100 350 190 50 260 35 180 130 Highresolution mode 650 190 230 390 3,000 1,100 390 1,600 2,600 320 1,190 600 170 850 110 420 410 Standard mode Highspeed mode 500 150 180 300 2,200 870 300 1,300 2,000 250 920 460 130 650 85 320 310 330 100 120 200 1,450 570 200 850 1,300 160 600 300 85 430 55 210 200 Superhighspeed mode 200 60 70 120 900 350 120 520 800 100 350 190 50 260 35 180 130 * The optical fiber for the E32-T12F is 2 m long on each side, so the sensing distance is 4,000 mm. Reflective Models (Unit: mm) Model Type Flexible (new standard) Standard models Standard Breakresistant Fluorine coating E32-D11R/E32-D12R/E32-D15XR/ E32-DC200BR(B4R) E32-D14LR E32-D15YR/E32-D15ZR E32-D211R/E32-D21R/E32-D22R/ E32-D25XR/E32-DC200FR(F4R) E32-D24R E32-D25YR/E32-D25ZR E32-DC200/E32-D15X/ E32-DC200B(B4) E32-D12 E32-D14L E32-D15Y/E32-D15Z E32-D211/E32-DC200E/E32-D22/ E32-D25X/E32-DC200F(F4) E32-D24 E32-D25Y/E32-D25Z E32-D11/E32-D15XB E32-D21B/E32-D221B E32-D21/E32-D22B E32-D25XB E32-D11U E3X-DA@-S Highresolution mode Standard mode 300 170 120 80 70 45 40 50 E3X-MDA@ SuperHighhighspeed speed mode mode Highresolution mode Standard mode Highspeed mode Superhighspeed mode 50 170 120 80 50 30 26 14 12 45 40 33 29 22 19 14 12 30 20 8 30 22 14 8 26 14 15 8 10 5 4 2 15 8 10 5 6 3.3 4 2 500 300 200 90 300 210 130 90 400 200 170 230 110 100 160 80 65 70 36 30 230 110 100 160 80 70 100 50 45 70 36 30 130 80 50 22 80 55 35 22 50 35 300 110 50 85 30 20 170 70 30 50 20 12 120 45 20 30 8 6 50 20 8 15 30 20 170 70 30 50 22 14 125 50 22 35 14 9 80 30 14 23 8 6 50 20 8 15 300 170 120 50 170 125 80 50 9 E3X-DA-S/MDA Model Type E32-D16 Long distance, high power Ultracompact, ultrafine sleeve Specialbeam models Environmentresistant models Chemicalresistant 40 to 700 40 to 450 40 to 240 Standard mode Highspeed mode Superhighspeed mode 40 to 600 40 to 490 40 to 300 40 to 240 400 260 110 400 270 180 110 E32-D21L/E32-D22L 210 130 80 35 130 85 55 35 E32-D33 25 16 10 4 16 10 6 4 E32-D331 5 3 2 0.8 3 2 1.3 0.8 E32-C41 + E39-F3A-5 E32-C31 + E39-F3A-5 E32-C41 + E39-F3B E32-C31 + E39-F3B E32-C31 + E39-F3C Area sensing E32-D36P1 Heatresistant 40 to 1,000 Highresolution mode 650 E32-C42 + E39-F3A Coaxial/small spot E32-D32 + E39-F3A Convergentreflective Standard mode E3X-MDA@ SuperHighhighspeed speed mode mode E32-D11L E32-CC200R E32-CC200 E32-D32L E32-C31/E32-D32 Retroireflective E3X-DA@-S Highresolution mode 250 150 100 45 150 105 65 45 500 300 200 90 300 210 140 90 250 150 100 45 150 100 65 45 120 75 50 22 75 50 30 22 Spot diameter variable in the range 0.1 to 0.6 mm at distances in the range 6 to 15 mm. Spot diameter variable in the range 0.5 to 1mm at distances in the range 6 to 15 mm. 0.1-mm dia. spot at a distance of 7 mm. 0.5-mm dia. spot at a distance of 7 mm. 0.2-mm dia. spot at a distance of 17 mm. 0.5-mm dia. spot at a distance of 17 mm. Spot diameter of 4 mm max. at distances in the range 0 to 20 mm. 250 150 100 45 150 100 65 45 E32-R21 + E39-R3 (provided) 10 to 250 E32-R16 + E39-R1 (provided) 150 to 1,500 E32-L25/E32-L25A E32-L24S E32-L24L E32-L25L E32-L86 E32-D51 E32-D81R-S E32-D61-S E32-D73-S 3.3 0 to 4 2 to 6 (center 4) 5.4 to 9 (center 7.2) 4 to 10 160 72 230 400 230 165 110 72 150 90 60 27 90 63 40 27 100 60 40 18 60 40 25 18 E32-D12F 160 95 65 30 95 70 45 30 E32-D14F 70 40 30 10 40 28 18 10 10 E3X-DA-S/MDA Application-specific Models (Unit: mm) Model E3X-DA@-S Highresolution mode Type Label detection Liquid-level detection Standard mode E32-G14 E32-T14 Wafer mapping Highspeed mode Superhighspeed mode 4,000* 3,400 2,250 900 2,900 2,200 1,450 900 Applicable tube: Transparent tube with a diameter in the range 8 to 10 mm and a recommended wall thickness of 1 mm E32-D36T Applicable tube: Transparent tube (no restriction on diameter) E32-A01 Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm and a recommended wall thickness of 1 mm Applicable tube: Transparent tube with a diameter in the range 6 to 13 mm and a recommended wall thickness of 1 mm Liquid-contact model E32-L16-N 0 to 15 0 to 12 0 to 15 0 to 12 E32-A08 10 to 20 --- 10 to 20 --- E32-A07E1(E2) 15 to 25 --- 15 to 25 --- E32-L66 Glasssubstrate Mapping Standard mode 10 E32-D82F1(F2) Glasssubstrate alignment Highresolution mode E32-L25T E32-A02 Applicationspecific models E3X-MDA@ SuperHighhighspeed speed mode mode 5 to 18 5 to 16 --- 5 to 18 5 to 14 --- E32-A09/E32-A09H 15 to 38 --- 15 to 38 --- E32-A09H2 20 to 30 --- 20 to 30 --- E32-A03/E32-A03-1 1,150 890 600 250 750 580 380 250 E32-T24S 1,750 1,300 870 350 1,100 870 580 350 460 340 225 100 300 220 145 100 E32-A04/E32-A04-1 * The optical fiber for the E32-T14 is 2 m long on each side, so the sensing distance is 4,000 mm. 11 E3X-DA-S/MDA Green, Blue, and Infrared Light Sources (Unit: mm) Model Type Throughbeam models Reflective models Applicationspecific models E32-T11R/E32-T12R/E32-T15XR/ E32-TC200BR(B4R) E32-T14LR/E32-T15YR/E32-T15ZR Standard E32-TC200/E32-T12/E32-T15X/ E32-TC200B(B4) E32-T14L/E32-T15Y/E32-T15Z Special beam E32-T11L/E32-T12L E32-D11R/E32-D12R/E32-D15XR/ E32-DC200BR(B4R) E32-D14LR E32-D15YR/E32-D15ZR Standard E32-DC200/E32-D15X/ E32-DC200B(B4) E32-D14L E32-D15Y/E32-D15Z E32-D11L E32-CC200R Special beam E32-CC200 E32-D32L E32-C31/E32-D32 Label detection E32-T14 E32-G14 E3X-DAG@-S/DAB@-S HighSuperStan- Highresohighdard speed lution speed mode mode mode mode E3X-DAH@-S Highresolution mode Standard mode Highspeed mode Superhighspeed mode 65 50 35 30 280 190 130 55 25 20 22 12 100 75 80 21 100 75 50 45 400 280 180 80 50 150 40 120 30 85 25 75 240 700 160 490 110 320 45 140 17 14 10 8 120 90 60 21 4.4 4.2 3.5 3.3 2.5 2.2 2.2 2.1 32 28 24 20 16 13 5.5 5 32 25 16 16 200 150 100 35 11 10 44 15 32 15 7.5 9 8 35 12 25 12 6 6 5.5 22 8 16 8 4 5.5 5 22 7.5 16 7.5 3.5 80 65 260 100 200 100 50 60 50 190 75 150 75 37 40 33 130 50 100 50 25 14 11 45 17 35 17 8.5 320 260 220 160 1,800 1,200 820 360 10 10 Refer to E32 Series for details on Fiber Units. 12 E3X-DA-S/MDA Output Circuit Diagrams NPN Output Operation mode Model Light-ON E3X-DA11-S E3X-DA6-S E3X-DAG11-S E3X-DAG6-S E3X-DAB11-S E3X-DAB6-S E3X-DA11SE-S E3X-DA6SE-S Operation selector Timing charts Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Load Operate (relay) Reset Output circuit LIGHT ON (L-ON) Power tuning indicator (orange) (Between brown and black leads) Dark-ON Incident light No incident light Operation ON indicator OFF (orange) ON Output OFF transistor Operate Load Reset (relay) Operation indicator (orange) Display Brown Black Load Control output Photoelectric Sensor main circuit 12 to 24 VDC Blue DARK ON (D-ON) (Between brown and black leads) Light-ON E3X-DA11TW-S E3X-DA6TW-S E3X-MDA11 E3X-MDA6 E3X-DA11AT-S E3X-DA6AT-S CH1/ Incident light CH2 No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load Reset (relay) LIGHT ON (L-ON) Display Operation indicator (orange) ch 1 Brown Load Black Control output 1 Photoelectric Sensor main circuit (Between brown and black leads) Dark-ON Operation indicator (orange) ch 2 CH1/ Incident light CH2 No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (relay) Reset Load Orange Control output 2 12 to 24 VDC Blue DARK ON (D-ON) (Between brown and black leads) Light-ON E3X-DA11RM-S E3X-DA6RM-S Incident light No incident light Operation ON indicator OFF (orange) ON Output OFF transistor Operate Load (relay) Reset LIGHT ON (L-ON) Power tuning indicator (orange) (Between brown and black leads) Dark-ON g Operation ON indicator OFF (orange) ON Output OFF transistor Operate Load Reset (relay) Operation indicator (orange) Display Brown Load Black Control output Photoelectric Sensor main circuit Orange DARK ON (D-ON) External input 12 to 24 VDC Blue (Between brown and black leads) Incident light Light-ON No incident light Operation ON indicator OFF (orange) LIGHT ON (L-ON) ON Output OFF transistor Load Operate (relay) Reset (Between brown and black leads) E3X-DA11AN-S Display Power tuning indicator (orange) Incident light Dark-ON No incident light Operation ON indicator OFF (orange) ON Output OFF transistor Load Operate (relay) Reset Operation indicator (orange) Brown Load Black Control output Analog Orange output models Photoelectric Sensor main circuit 12 to 24 VDC Load 10kmin Blue DARK ON (D-ON) (Between brown and black leads) Note: 1. The ON/OFF regions when areas settings are used with the E3XDA@TW-S are as follows: LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2. DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2. 2. Timing Charts for Timer Function Settings (T: Set Time) ON delay OFF delay One-shot Incident light Incident light Incident light No incident light No incident light No incident light L-ON D-ON T ON OFF ON OFF L-ON T D-ON T ON OFF ON OFF L-ON T D-ON T ON OFF T 3. Control Output (AND, OR, Sync) and Timing Chart for Timer Settings (T: Set Time) ON OFF ON CH2 OFF OUT ON (AND) OFF OUT ON (OR) OFF OUT ON (sync) OFF CH1 ON OFF ON CH2 OFF ON delay ON (AND) OFF OFF delay ON (AND) OFF One-shot ON (AND) OFF CH1 T T T T ON OFF 13 E3X-DA-S/MDA PNP Output Model Operation mode Timing chart Operation selector Output circuit Incident light E3X-DA41-S E3X-DA8-S E3X-DAG41-S E3X-DAG8-S E3X-DAB41-S E3X-DAB8-S E3X-DA41SE-S E3X-DA8SE-S Light-ON No incident light Operation ON indicator OFF (orange) ON Output transistor Load (relay) LIGHT ON (L-ON) Operation indicator (orange) Display OFF Power tuning indicator (orange) Operate Reset (Between blue and black leads) Incident light Dark-ON No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Load Operate (relay) Reset Photoelectric Sensor main circuit DARK ON (D-ON) Brown Control output Black 12 to 24 VDC Load Blue (Between blue and black leads) Light-ON E3X-DA41TW-S E3X-DA8TW-S E3X-MDA41 E3X-MDA8 E3X-DA41AT-S E3X-DA8AT-S Incident light CH1/ CH2 No incident light Operation ON indicator OFF (orange) ON Output transistor Load (relay) OFF LIGHT ON (L-ON) Operation indicator (orange) ch 1 Display Operate Reset Photoelectric Sensor main circuit (Between blue and black leads) Incident light Dark-ON Operation indicator (orange) ch 2 CH1/ CH2 No incident light Operation ON indicator OFF (orange) ON Output transistor Load (relay) Brown Control output 1 Black 12 to 24 VDC Control output 2 Orange Load Load DARK ON (D-ON) Blue OFF Operate Reset (Between blue and black leads) Incident light Light-ON No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Load Operate (relay) Reset E3X-DA41RM-S E3X-DA8RM-S LIGHT ON (L-ON) Display Power tuning indicator (orange) (Between blue and black leads) Incident light Dark-ON No incident light Operation ON indicator OFF (orange) Output transistor Load (relay) ON Operation indicator (orange) Photoelectric Sensor main circuit Brown Orange Black Blue External input Control output 12 to 24 VDC Load DARK ON (D-ON) OFF Operate Reset (Between blue and black leads) Incident light Light-ON No incident light Operation ON indicator OFF (orange) ON Output transistor Load (relay) LIGHT ON (L-ON) OFF Power tuning indicator (orange) Operate Reset (Between blue and black leads) E3X-DA41AN-S Incident light Dark-ON No incident light Operation ON indicator OFF (orange) ON Output transistor Load (relay) Display Operation indicator (orange) Photoelectric Sensor main circuit Brown Analog Orange output models 12 to Control 24 VDC output Black Blue Load Load 10kmin DARK ON (D-ON) OFF Operate Reset (Between blue and black leads) Note: The ON/OFF regions when areas settings are used with the E3X-DA@TW-S are as follows: LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2. DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2. 14 E3X-DA-S/MDA Nomenclature Amplifier Units E3X-DA@-S E3X-DA@RM-S E3X-DA@AN-S Main Display (Red) Incident level, function, etc. Sub-Display (Green) Threshold, function settings, etc. E3X-DA@TW-S E3X-DA@AT-S E3X-MDA@ Operation Keys Function setting operations UP Lock lever Locks the fiber. DOWN Main Display (Red) Incident level, function, etc. Lock lever Locks the fiber. Sub-Display (Green) Threshold, function settings, etc. Operation Keys Function setting operations UP DOWN MODE MODE Operation Indicator (orange) ON when output is ON. OFF when output is OFF. Power Tuning Indicator ON: Power tuning is set. Operation Selector Use to switch between Light ON and Dark ON modes. Mode Selector Use to select SET or RUN mode. Operation indicator for channel 1 (orange) ON when output is ON. OFF when output is OFF. Channel Selector Use to switch between channels Operation indicator for 1 and 2. channel 2 (orange) Mode Selector ON when output is ON. Use to select SET or RUN mode. OFF when output is OFF. Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Amplifier Unit Removing Connectors 1. Slide the slave Amplifier Unit(s) for which the Connector is to be removed away from the rest of the group. 2. After the Amplifier Unit(s) has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other Amplifier Units first.) Press down Lever Designing Operation after Turning Power ON The Sensor is ready to detect within 200 ms after the power supply is turned ON. If the Sensor and load are connected to separate power supplies, be sure to turn ON the Sensor first. Mounting Connecting and Disconnecting Connectors Remove Adding and Removing Amplifier Units Adding Amplifier Units 1. Mount the Amplifier Units one at a time onto the DIN track. Mounting Connectors 1. Insert the Master or Slave Connector into the Amplifier Unit until it clicks into place. 2. Slide the Amplifier Units together, line up the clips, and press the Amplifier Units together until they click into place. Insert 2. Attach the protector seals (provided as accessories) to the sides of master and slave connectors that are not connected. Seal Seal Note: Attach the seals to the sides with grooves. Click into place Removing Amplifier Units Slide Amplifier Units away from each other, and remove from the DIN track one at a time. (Do not attempt to remove Amplifier Units from the DIN track without separating them first.) Note: 1. The specifications for ambient temperature will vary according to the number of Amplifier Units used together. For details, refer to Ratings and Specifications. 2. Always turn OFF the power supply before joining or separating Amplifier Units. 15 E3X-DA-S/MDA Fibers That Cannot Be Free-Cut (with Sleeves) Mounting the End Plate (PFP-M) An End Plate should be used if there is a possibility of the Amplifier Unit moving, e.g., due to vibration. If a Mobile Console is going to be mounted, connect the End Plate in the direction shown in the following diagram. 9 mm 13 mm 2. Disconnecting Fibers Remove the protective cover and raise the lock lever to pull out the fibers. End Plate Mounting the Mobile Console Head Leave a gap of at least 20 mm between the nearest Amplifier Unit and the Mobile Console head. Protective cover 20 mm Locked Fiber Connection The E3X Amplifier Unit has a lock button for easy connection of the Fiber Unit. Connect or disconnect the fibers using the following procedures: 1. Connection Open the protective cover, insert the fibers according to the fiber insertion marks on the side of the Amplifier Unit, and lower the lock lever. Unlocked Note: 1. To maintain the fiber properties, confirm that the lock is released before removing the fibers. 2. Be sure to lock or unlock the lock button within an ambient temperature range between -10C and 40C. Adjusting Mutual Interference Protection Function There may be some instability in the digital display values due to light from other sensors. If this occurs, decrease the sensitivity (i.e., decrease the power or increase the threshold) to perform stable detection. EEPROM Writing Error Lock button Protective cover Locked Unlocked Insertion position If the data is not written to the EEPROM correctly due to a power failure or static-electric noise, initialize the settings with the keys on the Amplifier Unit. ERR/EEP will flash on the display when a writing error has occurred. Optical Communications Fiber insertion mark Several Amplifier Units can be slid together and used in groups. Do not, however, slide the Amplifier Units or attempt to remove any of the Amplifier Units during operation. Fiber 9 mm Fibers with E39-F9 Attachment Others Protective Cover Always keep the protective cover in place when using the Amplifier Unit. Mobile Console Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S-series Amplifier Units. Fiber Unit 9 mm 13 mm 16 E3X-DA-S/MDA (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Amplifier Units Amplifier Units with Cables E3X-DA11-S E3X-DA41-S E3X-DAG11-S E3X-DAG41-S E3X-DAB11-S E3X-DAB41-S E3X-DA11RM-S E3X-DA41RM-S E3X-DA11TW-S E3X-DA41TW-S E3X-DA11SE-S E3X-DA41SE-S E3X-DA11AT-S E3X-DA41AT-S E3X-DA11AN-S E3X-DA41AN-S E3X-MDA11 E3X-MDA41 Operation indicator Round ( ): Power tuning indicator Oblong ( ): Operation indicator for channel 2 Main display Sub-display Vinyl-insulated round cable Standard length: 2 m* CH2 CH1 (E3X-DA@-S) (E3X-MDA@) *Cable Specifications E3X-DA11-S -DA41-S -DAG11-S -DAG41-S -DAB11-S -DAB41-S 4-dia., 3-conductor (Conductor cross section: 0.2 mm2, insulator diameter: 1.1 mm) E3X-DA11TW-S -DA41TW-S -DA11RM-S -DA41RM-S 4-dia., 4-conductor (Conductor cross section: 0.2 mm2, insulator diameter, 1.1 mm) E3X-MDA11 -MDA41 4-dia., 2-conductor (Conductor cross section: 0.2 mm2, insulator diameter: 1.1 mm) With Mounting Bracket Attached 3.9 x 3 = 11.7 32.8 29.8 3.9 x 3 15.1 =11.7 12.15 3.25 * The Mounting Bracket can also be used on this side. 4.3 10 10 A* 70 Two, 2.4 dia. 4.5 32 Four, 2.4 dia. 7 4.5 4.5 5.65 5.65 (E3X-DA@-S) 9.9 12.5 3.4 (E3X-MDA@) 28.1 18.7 16 34.8 Hole for optical communications 44.3 Two, 3.2 dia. holes 3.4 Two, M3 16 28.1 Mounting Bracket (E39-L143) SUS304 stainless steel 4.4 16 Mounting Holes 17 E3X-DA-S/MDA Amplifier Units with Connectors E3X-DA6-S E3X-DA8-S E3X-DAG6-S E3X-DAG8-S E3X-DAB6-S E3X-DAB8-S E3X-DA6RM-S E3X-DA8RM-S CH2 E3X-DA6TW-S E3X-DA8TW-S E3X-DA6SE-S E3X-DA8SE-S E3X-DA6AT-S CH1 E3X-DA8AT-S (E3X-DA@-S) E3X-MDA6 E3X-MDA8 Round ( ): Power tuning indicator Oblong ( ): Operation indicator for channel 2 Operation indicator Main display Sub-display (E3X-MDA@) *1 The Mounting Bracket can also be used on this side. *2 Cable Diameters With Mounting Bracket Attached 3.9 x 3 = 11.7 32.8 29.8 3.9 x 3 15.1 =11.75 12.15 3.25 10 10 A *1 E3X-CN22 (2 conductors) E3X-CN21 (4 conductors) E3X-CN11 (3 conductors) 4.0-mm dia. E3X-CN12 (1 conductor) 2.6-mm dia. 70 4.3 8.1 Connector Two, 2.4 dia. Four, 2.4 dia. 4.5 Dia. A*2 32 7 4.5 4.5 5.65 5.65 (E3X-DA@-S) 9.9 12.95 3.4 (E3X-MDA@) 28.1 18.7 16 34.8 44.3 Two, 3.2-dia. holes 3.4 Two, M3 Hole for optical communications Mounting Bracket (E39-L143) SUS304 stainless steel 4.4 16 Mounting Holes 28.1 16 18 E3X-DA-S/MDA Amplifier Unit Connectors Master Connectors E3X-CN11 E3X-CN21 2,000+500 10 6 2.9 2.6 10.7 6.8 4 * 4 dia. 14.4 6 0.8 8.4 15.1 302 102 50+50 *E3X-CN11: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) Slave Connectors E3X-CN12 E3X-CN22 2,000+500 10 6 10.7 6.8 2.9 4 2.6 * E3X-CN12: 2.6 dia. E3X-CN22: 4 dia. 14.4 6 0.8 3 8.4 15.1 302 102 50+50 *E3X-CN12: 2.6-dia. vinyl-insulated round cable with 1 conductor (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) 19 E3X-DA-S/MDA Mobile Console E3X-MC11-SV2 Mobile Console AC adapter jack Menu indicators 22 Mobile Console Head Communications jack Optical communications connection indicator Communications jack 52.8 10 20 Channel indicator (38.2) 13.1 16.3 28.8 31.8 13.2 Sensor operation indicator 1.2 5.1 12.3 Main display 17.3 24.3 Channel buttons 27.7 30.3 Sub-display 9.9 136 UP key Optical communications position RIGHT key M5 ball plunger LEFT key 31.2 36.7 51.3 5.6 ESC/PWR key DOWN key ENT key Operation keys Battery indicators 50 Refer to E32 Series for details on Fiber Units. 20 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.