CSM_D4B-_N_DS_E_10_7
1
Safety Limit Switch
D4B-@N
Robust safety limit switch with metal housing
Slow-action and snap-action contact with
certified direct opening operation
certification
Direct opening mechanism (NC contacts only) added to
enable opening contacts when faults occur, such as fused
contacts.
Safety of lever settings ensured using a mechanism that
engages a gear between the operating position indicator plate
and the lever.
Equipped with a mechanism that indicates the applicable
operating zone, as well as push-button switching to control left
and right motion.
Head seal structure strengthened to improve seal properties
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range:
–40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Model Number Structure
Model Number Legend
1. Conduit size
2: G1/2 (PF1/2) (1-conduit)
4: M20 (1 conduit)
2. Built-in Switch
1: 1NC/1NO (snap-action)
5: 1NC/1NO (slow-action)
A: 2NC (slow-action)
3. Actuator
11: Roller lever (resin roller)
15: Roller lever (stainless steel roller)
16: Adjustable roller lever
17: Adjustable rod lever
70: Plunger
71: Roller plunger
Note: Contact your sales representative for details on
models with safety standard certification.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read the “Safety Precautions” on page 9.
1 2 3
D4B-@@@@N
2
D4B-@N
Ordering Information
Set Model Numbers
Consult with your OMRON representative when ordering any models that are not listed in this table.
Safety Limit Switches (with Direct Opening Mechanism)
General-purpose Limit Switches
Note: Consult your OMRON representative for products.
Actuator Conduit openings
1NC/1NO (Snap-action) 1NC/1NO (Slow-action) 2NC (Slow-action)
Model Direct
opening Model Direct
opening Model Direct
opening
Roller lever
(resin roller)
G1/2 (PF1/2) D4B-2111N D4B-2511N D4B-2A11N
M20 D4B-4111N D4B-4511N D4B-4A11N
Roller lever
(stainless steel
roller)
G1/2 (PF1/2) D4B-2115N D4B-2515N D4B-2A15N
M20 D4B-4115N D4B-4515N D4B-4A15N
Plunger G1/2 (PF1/2) D4B-2170N D4B-2570N D4B-2A70N
M20 D4B-4170N D4B-4570N D4B-4A70N
Roller plunger G1/2 (PF1/2) D4B-2171N D4B-2571N D4B-2A71N
M20 D4B-4171N D4B-4571N D4B-4A71N
Actuator Conduit openings
1NC/1NO (Snap-action) 1NC/1NO (Slow-action) 2NC (Slow-action)
Model Direct
opening Model Direct
opening Model Direct
opening
Adjustable roller
lever
G1/2 (PF1/2) D4B-2116N
---
D4B-2516N
---
D4B-2A16N
---
M20 D4B-4116N D4B-4516N D4B-4A16N
Adjustable rod
lever
G1/2 (PF1/2) D4B-2117N
---
D4B-2517N
---
D4B-2A17N
---
M20 D4B-4117N D4B-4517N D4B-4A17N
3
D4B-@N
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50041
EN60204-1
EN ISO 14119
Certified Standards
Snap-action Models
*Adjustable roller lever, adjustable rod lever only.
Slow-action Models
*Adjustable roller lever, adjustable rod lever only.
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Note: As protection against short-circuiting, use either a gI-type or gG-type 10 A fuse that conforms to IEC60269.
UL/CSA: (UL508, CSA C22.2 No. 14)
A600
Certification body Standard File No.
TÜV Rheinland
EN60947-5-1
(certified direct
opening mechanism)
GS-ET-15
Consult your
OMRON
representative for
details.
EN60947-5-1
(uncertified direct
opening mechanism)
J50005477 *
UL UL508 E76675
CSA C22.2 No. 14 LR45746
CQC (CCC) GB14048.5 2003010305077612
2003010305095927
Certification body Standard File No.
TÜV Rheinland
EN60947-5-1
(certified direct
opening mechanism)
GS-ET-15
Consult your
OMRON
representative for
details.
EN60947-5-1
(uncertified direct
opening mechanism)
J50005477 *
UL UL508 E76675
CSA C22.2 No. 14 LR45746
CQC (CCC) GB14048.5 2003010305077612
2003010305095927
Item Utilization category AC-15
Rated operating current (Ie)2 A
Rated operating voltage (Ue)400 V
Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC
480 VAC
600 VAC
10 A
60
30
15
12
6
3
1.5
1.2
7,200 720
D4B-@N
4
Ratings
Note: 1. The above values are continuous currents.
2. Inductive loads have a power factor of 0.4 or higher (AC) or a time constant of 7 ms or lower (DC).
3. Lamp loads have a inrush current of 10 times the normal current.
4. Motor loads have a inrush current of 6 times the normal current.
Characteristics
Note: 1. The above values are initial values.
2. The above values may vary depending on the model. Consult your OMRON sales representative for details.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand.
*2. The durability is for an ambient temperature of 5 to 35°C and ambient humidity of 40% to 70%. For further conditions, consult your OMRON
sales representative.
*3. The above values may vary depending on switching frequency, environmental condition, and relativity level, consult your OMRON sales
representative.
Rated voltage (V)
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250
400
10
10
10
3
2
1.5
1.5
1
0.8
10
10
3
5
3
1.5
2.5
1.5
0.8
8 VDC
14
30
125
250
10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
6
6
4
0.2
0.1
Inrush current 30 A max.
Degree of protection *1IP67 (EN60947-5-1)
Durability *2Mechanical 30,000,000 operations min. (snap-action)
10,000,000 operations min. (slow-action)
Electrical 500,000 operations min. (10 A resistive load at 250 VAC)
Operating speed 1 mm/s to 0.5 m/s
Operating frequency Mechanical 120 operations/minute
Electrical 30 operations/minute
Contact resistance 25 mΩ max.
Minimum applicable load *3180 mA resistive load at 5 VAC
(N-level reference value)
Rated insulation voltage (Ui)600 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class I (with ground terminal)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse withstand voltage
(EN60947-5-1)
Between terminals
of same polarity 2.5 kV (snap-action)/4 kV (slow-action)
Between terminals
of different polarity 4 kV (slow-action)
Between each
terminal and ground
4 kV
Insulation resistance 100 MΩ min. (at 500 VDC) between terminals of the same polarity and between each
terminal and non-current-carrying part
Contact gap 2 × 2 mm min. (slow-action)
2 × 0.5 mm min. (snap-action)
Vibration resistance Malfunction 10 to 55 Hz, 0.75 mm single amplitude
Shock resistance Destruction 1,000 m/s2 min.
Malfunction 300 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe)20 A (EN60947-5-1)
Ambient operating temperature –40 to 80°C (with no icing)
Ambient operating humidity 95% max.
Weight Approx. 250 g
5
D4B-@N
Engineering Data
Electrical Durability (Snap-action)
(Ambient temperature: 5 to 30°C, ambient humidity: 40 to 70%)
Structure and Nomenclature
Structure
250 VAC
125 VAC
1,000 1,000
500 500
300 300
100 100
50 50
30 30
10 10
480 VAC
250 VAC
500 VAC
(cosφ = 1) (cosφ = 0.4)
Operations (x 104)
Operations (x 104)
Switching current (A) Switching current (A)
Operating frequencies:
30 times/min., cosφ = 1
Operating frequencies:
30 times/min., cosφ = 0.4
The operating position indicator plate
H
ea
d
Conduit Opening
Roller
Ground Screw
Ground screws are provided on all
models for increased safety.
Lever (Form Lock Structure)
Seal Ring
Can be connected in any of four directions (except for
Roller Plunger Models, which can be connected at either
of 2 directions that differ by 90°)
The roller lever switch employs a
system which allows
selection of operation on only one
side (left or right)
or both sides without the use of
any tools.
G1/2 or M20
Nylon rollers used for superior resistance to wear.
The lever has an operating position indication plate
and grooves that mate every 90° to prevent slipping
between the rotary axis and lever.
Built-in Switch
Direct opening mechanism used for NC contact to
separate contact for faults, such as contact welding.
The heights of the NC and NO terminals are different
to enable easier wiring.
Cover
Sealing properties improved by using a X ring and
bearing-free structure.
D4B-@N
6
Direct Opening Mechanism
1NO/1NC Contact (Snap-action)
Conforms to EN60947-5-1 Direct Opening (Only NC contact has a direct opening mechanism.)
1NC/1NO Contact (Slow-action) 2NC Contact (Slow-action)
Contact Form
Note: Terminal numbers are according to EN50013; contact symbols are according to IEC60947-5-1.
A
B
1. When contact welding occurs. 2. When contacts are being pulled apart.
Movable contact
Plunger
Safety cam
Fixed contact (NC)
Movable contact
blade
Safety cam directly
pushes up the
movable contact
blade.
3. When contacts are completely
pulled apart.
Contact spring
Return spring
Fixed contact (NC)
Movable contact
Plunger
Conforms to EN60947-5-1 Direct Opening
(Only NC contact has a direct opening mechanism.)
When contact welding occurs, the contacts are separated
from each other by the plunger being pushed in.
Fixed contact (NO)
Contact spring
Return spring
Fixed contact (NC)
Movable contact
Plunger
Conforms to EN60947-5-1 Direct Opening
(Both NC contacts have a direct opening mechanism.)
When contact welding occurs, the contacts are separated
from each other by the plunger being pushed in.
Model Contact Contact form Diagrams Explanation
D4B-@1@N1NC/1NO
(Snap-action)
D4B-@5@N1NC/1NO
(Slow-action)
D4B-@A@N2NC
(Slow-action)
13 14
11 12
Za 11-12
13-14
Stroke
ON
Only NC contact 11-12 has a
certified direct opening
mechanism.
Terminal numbers 11-12 and
13-14 cannot be used as unlike
poles.
11
23
12
24
Zb
11-12
23-24
Stroke
ON
Only NC contact 11-12 has a
certified direct opening
mechanism.
Terminal numbers 11-12 or
23-24 can be used as unlike
poles.
11
21
12
22
Zb
11-12
21-22
Stroke
ON
7
D4B-@N
Dimensions and Operating Characteristics (Unit: mm)
Note: Omitted dimensions are the same as those for the Roller Lever Type Models
D4B-2@@@N have a G1/2 conduit opening.
D4B-4@@@N have a M20 conduit opening.
Switches
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
*1. The lever can be set to any desired position by turning the operating position indicator.
*2. In terms of construction, the Switch is a General-purpose Limit Switch rather than a Safety Limit Switch.
Note: Variation occurs in the simultaneity of contact opening/closing operations of 2NC contacts. Check contact operation.
*1. The operating characteristics of these Switches were measured with the roller level set at 31.5 mm.
*2. The operating characteristics of these Switches were measured with the rod level set at 140 mm.
*3. The operating characteristics are the same for the left and the right.
*4. Only for slow-action models.
*5. Only for snap-action models.
*6. Reference values.
*7. Must be provided to ensure safe operation.
Model
Operating characteristics D4B-@@11N D4B-@@15N D4B-@@16N
*1D4B-@@17N
*2
Operating force
Release force
Pretravel
Overtravel
Movement differential
Direct opening travel
Direct opening force
Total travel
OF max.
RF min.
PT *3
PT (2nd) *4 *6
OT min.
MD max. *5
DOT min. *4 *7
*5 *7
DOF min. *7
TT *6
9.41N
1.47N
21°±3°
(45°)
50°
12°
35°
55°
19.61N
(75°)
9.41N
1.47N
21°±3°
(45°)
50°
12°
35°
55°
19.61N
(75°)
9.41N
1.47N
21°±3°
(45°)
50°
12°
35°
55°
19.61N
(75°)
2.12N
0.29N
21°±3°
(45°)
50°
12°
35°
55°
19.61N
(75°)
Conduit opening
5.3
7.3
56 16
131.3±1.2
23
8
28.3
22.5
99.5
77
74
15
31.5
43
11.5
31.5R
30±0.2
62±1
PT
21°
±3°
60±0.2
40+1
0
17.5 dia. × 7 resin roller
Cover
M5 × 12
Allen-head bolt
Set position
indicator plate
*1
Two, 5.3-dia.
mounting holes
Two, M4 × 12
cover mounting
screws
Four, M3.5 × 24.5
head
mounting screws
Roller Lever
D4B-@@11N
15
99.5
74
22.5
40
+1
0
30
±0.2
131.3
±1.2
60
±0.2
23
PT
21°
±3°
31.5R
11.5
8
5.3
7.3
Two, 5.3 dia.
mounting holes
Cover
Set position
indicator plate
*1
M5 × 12
Allen-head bolt
17.5 × 7 stainless steel roller
Four, M3.5 × 24.5
head
mount
ing screws
Conduit opening
Two, M4 × 12
cover
mount
ing
screws
43
31.5
77
62
±1
56
16
28.3
Roller Lever (Stainless Steel Roller)
D4B-@@15N
1
2
3
23
8
5.3
7.3
Set position
indicator plate *1
43
15
31.5
99.5
77
74
22.5
53
46.8 16
28.3
60
±0.2
64.4
71
±1
Conduit opening
30
±0.2
40
+1
0
25 to 89R
Cover
M5 × 16
Allen-head bolts
Two, 5.3-dia.
mounting holes
Two, M4 × 12 cover
mounting screws
Four, M3.5 × 24.5
head
mounting screws
PT
21°
±3°
19 dia. × 7 resin roller
Adjustable Roller Lever *2
D4B-@@16N
23
5.4
8
5.3
7.3
43
15
31.5
99.5
77
74
22.5
56.8 16
28.3
Setting position
indicator *1
60
±0.2
30
±0.2
66
±1
Conduit opening
40
+1
0
145 max.
Cover
M5 × 12
Allen-head bolts
Two, 5.3-dia.
mounting holes
Two, M4 × 12 cover
mount
ing screws
Four, M3.5 × 24.5
head
mount
ing screws
PT
21°
±3°
3 dia. × 160 stainless steel rod
Adjustable Rod Lever *2
D4B-@@17N
D4B-@N
8
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics Model D4B-@@70N D4B-@@71N
Operating force
Release force
Pretravel
Overtravel
Movement differential
Direct opening travel
Direct opening force
Total travel
OF max.
RF min.
PT max.
PT (2nd) *1 *3
OT min.
MD max. *2
DOT min. *4
DOF min. *4
TT *3
18.63 N
1.96 N
2 mm
(3 mm)
5 mm
1 mm
3.2 mm
49.03 N
(7 mm)
18.63 N
1.96 N
2 mm
(3 mm)
5 mm
1 mm
3.2 mm
49.03N
(7 mm)
Note: Variation occurs in the simultaneity of
contact opening/closing operations of
2NC contacts. Check contact
operation.
*1. Only for slow-action models.
*2. Only for snap-action models.
*3. Reference values.
*4. Must be provided to ensure safe
operation.
Free position
Operating position FP max.
OP 38 mm
35±1 mm
51 mm
48±1 mm
OP
PT
8
5.3
7.3
43
15
31.5
97
77
74
16
20
60±0.2
30±0.2
Conduit opening
40+1
0
9.2 dia.
Cover
Stainless steel
plunger
Two, 5.3-dia.
mounting holes
Two, M4 × 12 cover
mounting screws
Four, M3.5 × 19.5
head
mounting screws
Plunger
D4B-@@70N
Roller Plunger
D4B-@@71N
OP
PT
8
5.3
7.3
43
15
31.5
97
77
74
20
16
60±0.2
30±0.2
Conduit opening
40+1
0
9.2 dia.
Cover
12.7 dia. × 4.8
stainless steel roller
Two, 5.3-dia.
mounting holes
Two, M4 × 12 cover
mounting screws
Four, M3.5 × 19.5
head
mounting screws
9
D4B-@N
Application Precaution
Safety Precautions
Be sure to read the precautions for All Safety Limit Switches in the website at:http://www.ia.omron.com/.
Indication and Meaning for Safe Use
Do not use the Switch submerged in oil or water, or in locations
continuously subject to splashes of oil or water. Doing so may
result in oil or water entering the Switch interior. (The IP67 degree
of protection specification for the Switch refers to water penetration
while the Switch is submersed in water for a specified period of
time.)
Always attach the cover after completing wiring and before using
the Switch. Also, do not turn ON the Switch with the cover open.
Doing so may result in electric shock.
Appropriate Tightening Torque
Mounting
Use four M5 screws with washers to mount the standard model. Be
sure to apply the proper torque to tighten each screw.
Mounting Dimensions (M5)
Changes in Actuator Mounting Position
To change the angle of the lever, loosen the Allen-head bolts on
the side of the lever.
The operating position indicator plate * has protruding parts which
engage with the lever, thus allowing changes to the lever position
by 90°.
The back of the operating position indicator plate * has no
protruding parts. If this plate is turned over and attached, any angle
within a 360° range can be set. Do not turn over the plate, however,
when using the D4B-@N as a switch with a certified direct opening
mechanism. For an SUVA- or BIA-certified application, make sure
that the lever engages with the operating position indicator plate
securely so that the lever will not slip.
*The operating position indicator plate: Refer to page 5.
Changes in Head Mounting Position
By removing the screws on the four corners of the head, the head can
be reset in any of four directions. Make sure that no foreign materials
will penetrate through the head.
Changing the Operating Direction
Switches with Roller Levers
The operating direction of the lever can be easily
changed without using any tools. It can be set to
clockwise operation (CW) or counterclockwise
(CCW) operation.
Use the procedure given at the right to change
the operating direction.
Operating section
(on back of Head) Operating procedure
1. Remove the four Head set screws and remove the Head
from the Switch Box.
2. Turn the bottom of the Head toward you, press in the Head
Cover shown in the diagram at the left, and turn the Cover
clockwise or counterclockwise.
Note: The factory setting is for “CW.CCW.”
3. The “CW” setting is for clockwise operation and the “CCW”
setting is for counterclockwise operation. Set the Cover to
the desired position.
Head Cover
Operating
position
mark
(arrow)
Precautions
for Safe Use
Supplementary comments on what to do
or avoid doing, to use the product safely.
Precautions
for Correct
Use
Supplementary comments on what to do
or avoid doing, to prevent failure to
operate, or undesirable effect on product
performance.
Precautions for Safe Use
Precautions for Correct Use
Type Appropriate tightening
torque
1 M3.5 terminal screw 0.59 to 0.78 N·m
2 Cover mounting screw *1.18 to 1.37 N·m
3 Head mounting screw 0.78 to 0.88 N·m
4 M5 body mounting screw 4.90 to 5.88 N·m
5 Connector 1.77 to 2.16 N·m
6Lever Mounting Screws (Roller
Levers) 4.90 to 5.88 N·m
Be sure to tighten each
screw of the D4B-@N
properly, otherwise the
D4B-@N may malfunction. (1)
(2)(5)
(3)
(4)
(6)
30
60
Standard Model
D4B-@N
10
Wiring
Do not connect the bare lead wires directly to the terminals but be
sure to connect each of them by using an insulation tube and M3.5
round crimp terminals and tighten each terminal screw within the
specified torque range.
The proper lead wire is 20 to 14 AWG (0.5 to 2.5 mm2) in size.
Make sure that all crimp terminals come into contact with the casing
or cover as shown below, otherwise the cover may not be mounted
properly or the D4B-@N may malfunction.
Conduit Opening
Make sure that each connector is tightened within the specified
torque range.
The casing may be damaged if the connector is tightened
excessively.
Use an OMRON SC-series Connector (sold separately) that is
suited to the cable in diameter.
Others
The load for the actuator (roller) of the Switch must be imposed on
the actuator in the horizontal direction, otherwise the actuator or
the rotating axis may be deformed or damaged.
When using a long lever model, the D4B-
@@
16N or D4B-
@@
17N,
the
Switch may telegraph. To avoid telegraphing, take the following
precautions.
1. Set the lever to operate in one direction.
2. Modify the rear end of the dog to an angle of 15° to 30° as
shown below or to a secondary-degree curve.
3. Modify the circuit so as not to detect the wrong operating
signals.
D dia.
dz dia.
dz dia.: 3.7 mm
D dia.: 4.5 mm
B: 7.0 mm
L: 20.2 mm
F: 7.7 mm
l: 9.0 mm
Casing
Cover
Terminal screw
Crimp terminal
Terminal screw
Casing
Terminal screw
Cover
Crimp terminal
Correct
Correct
Incorrect
Incorrect
Crimp
terminal
Crimp terminal
Crimp terminal
Correct
Incorrect
Dog
Dog
Correct Incorrect
θθ
θ 30°15° θ 30°
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omrons sole obligation hereunder shall be, at
Omrons election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyers application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the users programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omrons test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omrons Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2019.2
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2019 All Right Reserved.