cui.com
CUI Inc │ SERIES: VHK200W │ DESCRIPTION: DC-DC CONVERTER date 12/16/2013 │ page 2 of 7
INPUT
parameter conditions/description min typ max units
operating input voltage 24 Vdc input models
48 Vdc input models
10
18
24
48
36
75
Vdc
Vdc
under voltage shutdown
24 Vdc input power up
power down
9.5
8.5
Vdc
Vdc
48 Vdc input power up
power down
17
16
Vdc
Vdc
CTRL1
positive logic models ON (>3.5 Vdc or open circuit)
models OFF (0~1.2 Vdc)
negative logic models ON (0~1.2 Vdc)
models OFF (>3.5 Vdc or open circuit)
lter pilter
input fuse 40A time delay fuse for 24 Vin models,
20A time delay fuse for 48 Vin models
Note: 1. Open collector refer to -Vin
OUTPUT
parameter conditions/description min typ max units
maximum capacitive load
12, 15, & 24 V output models
28 V output models
48 V output models
100
47
2,200
2,200
2,200
μF
μF
μF
line regulation2measured from low line to high line ±0.2 %
load regulation2measured from zero load to full load ±0.2 %
voltage accuracy ±1.5 %
adjustability ±10 %
switching frequency 250 kHz
transient response 25% step load change 500 µs
temperaturecoefcient ±0.03 %/°C
Note: 2.A100μFaluminumcapacitorisrequiredontheoutputforthe28Vdcoutputmodels.A47μFaluminumcapacitorisrequiredontheoutputfor48Vdcoutputmodels.
PROTECTIONS
parameter conditions/description min typ max units
short circuit protection continuous
over current protection at 90% output voltage 110 160 %
over voltage protection 115 140 %
over temperature protection shutdown 110 °C
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage for 1 minute: input to output; input to case;
output to case 1,500 Vdc
isolation resistance 10 MΩ
RoHS 2011/65/EU (CE)
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature see derating curve -40 85 °C
storage temperature -55 105 °C
For more information, please visit the product page.