TABLE III. Group A inspection for device type 01.
Terminal conditi ons (pi ns not designated may be high ≥ 2.0 V; low ≤ 0.7 V; or open).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
MIL-STD-
Cases
E, F
2 3 4 5 7 8 9 10 12 13 14 15 17 18 19 20 Subgroup
883
method Case
2
Measured
terminal Limits Unit
Test no. D2 D3 D4 RB RA Q4 Q3 GND Q2 Q1 GR GW WB WA D1 VCC Min Max
1 ICC 3005 49 4.5 V 4.5 V 4.5 V GND GND GND 4.5 V 4.5 V GND GND 4.5 V 5.5 V VCC 50 mA
Tc = 25°C
IOS 2/ 3011 50 " " " GND GND GND " " 5.5 V " Q1 -30 -130 "
" 51 5.5 V " " " GND " " " " " " Q2 " " "
" 52 5.5 V " " GND " " " " " " " Q3 " " "
" 53 5.5 V " " GND " " " " " " " Q4 " " "
I
OZH 54 0.7 V 0.7 V " 2.7 V 2.0 V 0.7 V 0.7 V 0.7 V 2.0 V " Q1 20 µA
55 2.0 V " " " 2.7 V " " " " " Q2 " "
56 2.0 V " " 2.7 V " " " " " " Q3 " "
57 2.0 V " " 2.7 V " " " " " " Q4 " "
I
OZL 58 " " " 0.4 V " " " " 2.0 V " Q1 -20 "
59 2.0 V " " " 0.4 V " " " " " Q2 " "
60 2.0 V " " 0.4 V " " " " " " Q3 " "
61 2.0 V " " 0.4 V " " " " " " Q4 " "
2 Same tests, terminal conditions, and limits as subgroup 1, except TC = +125°C and VI C tests are omitted.
3 Same tests, terminal conditions, and limits as subgroup 1, except TC = -55°C and VI C tests are omitted.
7 3/ 4/ Truth 3014 62 B A B B B L H GND L H B B B B A 5.0 V 5/
Tc = 25°C
table " 63 " " " " A " " " " " " " " A " " "
tests " 64 " " " A B " " " " " " " A B " " "
" 65 " " " " A " " " " " " " " A " " "
" 66 A B A B B H L " H L " " B B B " "
" 67 " " " " A L H " L H " " " " " " "
" 68 " " " A B " " " " " " " " " " " "
" 69 " " " " A " " " " " " " " " " " "
" 70 " " " B B H L " H L " A " " " " "
" 71 " " " " " " " " " " " B " " " " "
" 72 " " " " A " " " " " " " " A " " "
" 73 " " " A B " " " " " " " A B " " "
" 74 " " " " A " " " " " " " " A " " "
" 75 " A " B B " H " " H " " B B A " "
" 76 " " " " A " " " " " " " " A " " "
" 77 " " " A B " " " " " " " A B " " "
" 78 " " " " A " " " " " " " " A " " "
" 79 " " " " " " " " " " " A " " " " "
" 80 B B B B B " " " " " " " B B B " "
" 81 " " " " A " " " " " " " " A " " "
" 82 " " " A B " " " " " " " A B " " "
" 83 " " " " A " " " " " " " " " " " "
8 Same tests and terminal conditions as for subgroup 7 except TC = +125°C and TC = -55°C.
9 tPLH1 3003 84 GND GND GND OUT GND GND GND GND IN 5.0 V D1 to Q1 2 50 ns
Tc = 25°C
Fig. 4 85 IN " " " OUT " " " " " D2 to Q2 " " "
" 86 IN " " OUT " " " " " " D3 to Q3 " " "
" 87 IN " " OUT " " " " " " D4 to Q4 " " "
t
PHL1 " 88 " " " OUT " " " " IN " D1 to Q1 " 45 "
" 89 IN " " " OUT " " " " " D2 to Q2 " " "
" 90 IN " " OUT " " " " " " D3 to Q3 " " "
" 91 IN " " OUT " " " " " " D4 to Q4 " " "
t
PLH2 " 92 " " " OUT " " " " GND " RA to Q1 " " "
7/ " 93 GND " " " OUT " " " " " RA to Q2 " " "
" 94 GND " " OUT " " " " " " RA to Q3 " " "
" 95 GND " " OUT " " " " " " RA to Q4 " " "
t
PHL2 " 96 IN GND " OUT " " 5.0 V " 5.0 V " RB to Q1 " 50 "
6/ " 97 5.0 V " " " OUT " " " " " RB to Q2 " " "
" 98 5.0 V " " OUT " " " " " " RB to Q3 " " "
" 99 5.0 V " " OUT " " " " " " RB to Q4 " " "
See footnotes at end of device type 01.