34
Part Number
Standard Flow
Blower Data Unit of
117629 E*117630 E*
Stages
Measure
12
Vacuum, Max. (Sealed Vacuum) in. H2O28 47
mBar 69 117
Pressure, Max. (Sealed Pressure) in. H2O31 50
mBar 77 124
Flow Rate, Max. (Open Flow) C FM 6 7 6 5
L/sec 32 31
Length (Dimension “I” above) inches .69 1.60
mm 17.53 40.64
Length (Dimension “L” above) inches 3.21 4.12
mm 81.53 104.65
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 31.1 50.5
10 CFM in. H2O 26.8 45.4
20 CFM in. H2O 23.8 40.9
30 CFM in. H2O 20.5 33.7
40 CFM in. H2O 15.8 25.3
50 CFM in. H2O 10.0 16.0
60 CFM in. H2O 4.4 6.46
70 CFM in. H2O
NOTES:
Nominal input voltage: 240 Volts AC RMS +/- 10%, 60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric T esting: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
5.7” (145mm) BLDC Thru Flow Blower 400 WATT, 240 VOLT
5.7/400TFBHV99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.