40 Industrial Way East, Eatontown , NJ 07724 [USA]
Phone: (732) 460-0212, Fax: (732) 460-0214
www.aeroflex.com/acc, email: acc-sales@aeroflex.com
Parameter Specification Units
Frequency Range (min) 0.5 – 1.0 GHz
Phase Shift 360 Degrees
Insertion Loss (Max) 5 dB
Amplitude Ripple (Max) 1.25 ±dB
VSWR (Max) 2.0:1 Ratio
Specifications:
Features
Octave bands up to 18GHz
Fast Phase responce as low as 10nS
RF power operation 10mW peak/CW, RF power
survival 100mW peak/CW
Bias connection using pin or connector options
Custom configurations available
Revision Date: 2/23/2011
PQ-28
Analog Diode Phase Shifters
Screening:
Internal Visual per MIL-STD-883, Method 2017
Temperature Cycle: -65 °C to +100 °C, 10 cycles
Hermetically-sealed switches are fine and gross
leak checked per MIL-STD-883, Method 1014.
Optional High-Rel screening available upon
request. Contact the factory to discuss your
screening requirements.
Environmental Specifications:
Designed to meet:
MIL-E-5400, MIL-STD-202, MIL-E-16400
Operating Temp: -55°C to +125°C
Storage Temp: -65°C to +150°C
Humidity: MIL-STD-202F, M103, Cond B
Shock: MIL-STD-202F, M213, Cond B
Altitude: MIL-STD-202F, M105, Cond B
Vibration: MIL-STD-202F, M204, Cond B
Thermal Shock: MIL-STD-202F, M107, Cond A
Temperature Cycle: MIL-STD-202F, M105C, Cond D
Additional Electrical Specifications:
DC Supply: +5V ±0.5V @ +275mA
-5V ±0.5V @ -50mA
Control: 8 Bits command
1 Strobe line
Positive edge latched
Logic Levels: TTL/HMOS
Attenuation Accuracy: +/-0.15 dB or +/-1.5%
whichever is greater
Attenuation Stability
over Temperature: +/-0.025 dB/°C
Mechanical Specifications:
Case Style: PQ Outline
Connectors: SMA Female per MIL-C-39012
Connector Control: Micro-D 21 Pin
Bias & Control Pins: ø0.02” x 0.15” long
Mounting: ø0.10” through holes
(4) places
Outline A’ B’ C’ D’ E’ F’ G’
47.75 2.50 N/A 2.30 7.25 0.25 4PLCS
Aeroflex Control Componen. reserves the right to make changes to any products and
services herein at any time without notice. Consult Aeroflex or an authorized sales
representative to verify that the information in this data sheet is current before using
this product. Aeroflex does not assume any responsibility or liability arising out of the
application or use of any product or service described herein, except as expressly
agreed to in writing by Aeroflex; nor does the purchase, lease, or use of a product or
service from Aeroflex convey a license under any patent rights, copyrights, trademark
rights, or any other of the intellectual rights of Aeroflex or of third parties.
Copyright 2011 Aeroflex Control Components. All rights reserved.
www.aeroex.com/Microwave www.aeroex.com/ACC
Aeroflex Control Components
Aeroflex Microelectronic Solutions
40 Industrial Way East
Eatontown , NJ 07724 [USA]
Fax: (732) 460-0214
Sales
Phone: (732) 460-0212
ACC-sales@aeroflex.com
ISO 9001:2008 certified
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused.
Outline Drawing:
RF RF
BIAS
GND
`A'
`B'
`E'
`D'
.10
.38
2 PLS
.40
.25
.125 DIA
THRU `G'
MTG HOLES
`F'
`C'
BIAS
PIN
GROUND
`H' SURFACE
Custom Options Contact the Factory
Gray epoxy paint per MIL-C-22750
Video transient suppression
GPO connectors
ECL logic input
Phase and amplitude tracking
Other frequency ranges available from 1MHz to 26GHz
Reversed logic
Available without SMA connectors for drop-in applications
High rel screening
OUTLINE CASE STYLE PQ
Notes:
1. Monotonicity is Guaranteed.
2. The Phase shift varies with frequency at any
voltage setting. This variation, referenced to
at logic 0 for each frequency, is approximately
±15% for octave models, 10% for models with
25% bandwidth, and ±7.5% for models with
10% bandwidth. Phase flatness of the QQ-65 &
QQ-74 is ±25%.
3. A Connector, (SMA Female) is available in place
of the bias pin at no extra charge. This will be
placed at the center of the surface marked “H”
on the drawing. This is the .38 x A surface. If a
SMA Female is desired, add the suffix “C” to
the model number (e.g., PQ-45C)
4. Linearization models available, call for outline
and details.