AZ2110/AZ2120
RELAY ORDERING DATA
STANDARD RELAYS: UL 508: 1/8” Clearance, 1/4” Creepage
COIL SPECIFICATIONS ORDER NUMBER*
Nominal Max. Coil Must
Coil Continuous Resistance Operate Form A (SPST) Form C (SPDT)
VDC VDC ±10% VDC
5 7.3 27 3.75 AZ2110–1A–5D AZ2110–1C–5D
6 8.9 40 4.5 AZ2110–1A–6D AZ2110–1C–6D
9 13.9 97 6.75 AZ2110–1A–9D AZ2110–1C–9D
12 17.5 155 9.0 AZ2110–1A–12D AZ2110–1C–12D
15 22.5 256 11.25 AZ2110–1A–15D AZ2110–1C–15D
18 27.4 380 13.5 AZ2110–1A–18D AZ2110–1C–18D
24 36.1 660 18.0 AZ2110–1A–24D AZ2110–1C–24D
48 68.4 2,560 36.0 AZ2110–1A–48D AZ2110–1C–48D
70 104.4 5,500 52.5 AZ2110–1A–70D AZ2110–1C–70D
110 163.2 13,450 82.5 AZ2110–1A–110D AZ2110–1C–110D
STANDARD RELAYS: 1/16” Clearance, 1/8” Creepage
COIL SPECIFICATIONS ORDER NUMBER*
5 7.3 27 3.75 AZ2111–1A–5D AZ2111–1C–5D
6 8.9 40 4.5 AZ2111–1A–6D AZ2111–1C–6D
9 13.9 97 6.75 AZ2111–1A–9D AZ2111–1C–9D
12 17.5 155 9.0 AZ2111–1A–12D AZ2111–1C–12D
15 22.5 256 11.25 AZ2111–1A–15D AZ2111–1C–15D
18 27.4 380 13.5 AZ2111–1A–18D AZ2111–1C–18D
24 36.1 660 18.0 AZ2111–1A–24D AZ2111–1C–24D
48 68.4 2,560 36.0 AZ2111–1A–48D AZ2111–1C–48D
70 104.4 5,500 52.5 AZ2111–1A–70D AZ2111–1C–70D
110 163.2 13,450 82.5 AZ2111–1A–110D AZ2111–1C–110D
* Substitute “1B” in place of the “1A” to indicate 1 Form B contact. To indicate Class F version, add suffix “F”. For quick
connect terminals on contacts substitute “2120” or “2121” in place of “2110” or “2111”.
UL/CUR File E44211 Approved Contact Ratings
Form A Form B Form C
Load Type Cycles Volts (NO) (NC) NO NC
General Purpose 100,000 125 or 240 VAC 30 A 15 A 30 A 15 A
(Inductive) 30,000 277 VAC 30 A 30 A 30 A 30 A
Resistive 100,000 125 or 240 VAC 30 A 15 A 30 A 15 A
100,000 30 VDC 20 A 10 A 20 A 10 A
100,000 277 VAC 20 A — — —
100,000 240 VAC 15 A — — —
6,000 250 VAC 40 A — 40 A —
Ballast 6,000 125, 240, 277 VAC 6 A 3 A 6 A 3 A
6,000 277 VAC 20 A — — —
Pilot Duty 6,000 125 VAC 800 VA 290 VA 800 VA 290 VA
30,000 125 VAC 800 VA — 690 VA —
100,000 125 VAC 690 VA — 470 VA 275 VA
6,000 240 VAC 1152 VA 768 VA 1152 VA 768 VA
100,000 277 VAC 764 VA — 764 VA —
Motor Load 6,000 125 VAC 1 HP 1/4HP 1 HP 1/4HP
6,000 240 VAC 3 HP 1 HP 2 HP 1 HP
30,000 125 VAC 1 HP — 1 HP —
100,000 125 or 277 VAC 3/4HP — 3/4HP —
Definite Purpose 30,000 125 VAC 96 LRA 33 LRA 60 LRA 33 LRA
30 FLA 10 FLA 20 FLA 10 FLA
(LRA-Locked Rotor) 100,000 125 VAC 82.8 LRA — 82.8 LRA —
27 FLA — 27 FLA —
(FLA-Full Load) 30,000 240 VAC 80 LRA 33 LRA 60 LRA 33 LRA
30 FLA 10 FLA 20 FLA 10 FLA
100,000 277 VAC 60 LRA — 60 LRA —
20 FLA — 20 FLA —
Tungsten 6,000 125 VAC 15 A — 15 A 3 A
6,000 240 VAC 5 A — 5 A 3 A
6,000 120 VAC — 3 A — —
6,000 240 VAC — 3 A — —
TV–5 25,000 120 VAC TV–5 — TV–5 TV–3
TV–3 25,000 120 VAC — TV–3 — TV–3
Note: See AZ2100 Data Sheet for more complete UL and CUR approved contact ratings.