Fixed Inductors for Digital Audio Amplifier DAMW Inductance: 10Hx2, 20Hx2 DIMENSIONS 1-3 3.0 O0.8 4.0 t=0.3 21.0 Max. 17.0 1 10.0 3.0 7.0 1-3 10.0 17.0 (Unit: mm) FEATURES * Tight space by "2 in 1 unit" structure. * The magnetic shield in a metal case. * Low distortion at the time of the large output by High DC, current. * RoHS compliant * * * * 2in1 RoHS SELECTION GUIDE FOR STANDARD COILS TYPE DAMW (1) (2) (3) (4) TOKO Part Number Inductance (1) L (H) Tolerance (%) DC Resistance (2) (m) Max. Inductance Decrease Current(3) (A) Max. L L =10% Temperature Rise Current(4) T=20C (A) Max. 10x2 20x2 20 20 17 23 13.0 7.5 6.8 3.7 S1055KT-1007 S1055MT-1006 (1) Inductance is measured with a LCR meter 4284A (Agilent Technologies) or equivalent. (2) DC resistance is measured with a Digital Multimeter TR6871 (Advantest) or equivalent. (3) DC current value which the inductance value decreases by 10%. (4) DC current value which a coil temperature rises by 20C. (Reference ambient temperature 20C) (1) LCR4284AAgilentTechnologies (2) TR6871Advantest (3) 10% (4) 20 20