INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R04
CPC1976
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to the
device. Functional operation of the device at conditions beyond
those indicated in the operational sections of this data sheet is
not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage (VDRM) 600 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 22400 mW
Isolation Voltage, Input to Output 3750 Vrms
ESD, Human Body Model 4 kV
i2t for Fusing (1/2 Sine Wave, 50Hz) 8 A2s
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 20 mW / ºC
Electrical Characteristics @ 25ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current, Continuous VL=120-240Vrms IL0.070 - 2 Arms
Maximum Surge Current t < 16ms IPK --20 A
Off State Leakage Current VDRM I
LEAK --10 A
On-State Voltage Drop IL=2AP- - 1.1 1.25 VP
Critical Rate of Rise - dv/dt 1000 1200 - V/s
Switching Speeds
Turn-on IF = 5 mA ton - - 0.5 cycles
Turn-off toff - - 0.5 cycles
Zero-Cross Turn-On Voltage 1st half-cycle - - 7 20 V
Subsequent half-cycle - - - 5 V
Holding Current - IH- - 75 mA
Latching Current - IL- - 100 mA
Operating Frequency 1- 20 - 500 Hz
Load Power Factor for
Guaranteed Turn-On 260Hz PF 0.25 - - -
Input Characteristics
Input Control Current to Activate 360Hz IF--5 mA
Input Drop-out Voltage - - 0.8 - - V
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10 A
Common Characteristics
Input to Output Capacitance - CI/O --3 pF
1 Zero Cross 1st half-cycle @ <100Hz.
2 Snubber circuits may be required at low power factors.
3 For high-noise environments, or for high-frequency operation, use IF > 10mA.