Twin SLIC Protector Modified TO-220
http://www.teccor.com 2 - 56 © 2003 Teccor Electronics
+1 972-580-7777 SIDACtor® Data Book and Design Guide
Twin SLIC Protector Modified TO-220
Subscriber Line Interface Circuits (SLIC) are highly susceptible to transient voltages, such
as lightning and power cross conditions. To minimize this threat, Teccor provides this dual-
chip, fixed-voltage SLIC protector device.
For specific design criteria, see details in Figure 3.30.
* For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• VDRM is measured at IDRM.
• VS and VF are measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
• Off-state capacitance is measured across pins 1-2 or 3-2 at 1 MHz with a 2 V bias. Capacitance across pins 1-3 is approximately
half.
• Parallel capacitive loads may affect electrical parameters.
• Compliance with GR 1089 or UL 60950 power cross tests may require special design considerations. Contact the factory for further
information.
Electrical Parameters
Part
Number *
VDRM
Volts
VS
Volts VT
Volts
VF
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
CO
pFPins 1-2, 3-2
P0641A_2 58 77 4 5 5 800 2.2 120 40
P0721A_2 65 88 4 5 5 800 2.2 120 60
P0901A_2 75 98 4 5 5 800 2.2 120 60
P1101A_2 95 130 4 5 5 800 2.2 120 60
Surge Ratings (Preliminary Data)
Series
IPP
2x10 µs
Amps
IPP
8x20 µs
Amps
IPP
10x160 µs
Amps
IPP
10x560 µs
Amps
IPP
10x1000 µs
Amps
ITSM
60 Hz
Amps
di/dt
Amps/µs
A 150 150 90 50 45 20 500
C 500 400 200 150 100 50 500
1
3
2
(T)
(G)
(R)