First Edition May 9, 2000 LCD Module Specification Approved by Production Div. Checked by Quality Assurance Div. Checked by Design Engineering Div. Prepared by Production Div. Final Revision ******* Type No. Table of Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. General Specifications .............................................................................2 Electrical Specifications...........................................................................3 Optical Specifications ..............................................................................7 I/O Terminal.............................................................................................9 Test..........................................................................................................11 Appearance Standards............................................................................12 Code System of Production Lot ..........................................................15 Type Number..........................................................................................15 Applying Precautions .............................................................................15 Precautions Relating Product Handling................................................16 Warranty..................................................................................................17 Revision History Rev. Date DMF5005NF-SEW Page (BB) No.2000-0190 Comment OPTREX OPTREX CORPORATION Page 1/17 1.General Specif ications Operating Temp. min. 0 max. 50 Storage Temp. min. -20 max. 60 Dot Pixels 240 (W) x 64 (H) dots Dot Size 0.49 (W) x 0.49 (H) mm Dot Pitch 0.53 (W) x 0.53 (H) mm Viewing Area 132.0 (W) x 39.0 (H) mm Outline Dimensions 180.0 (W) x 65.0 (H) x 12.0 max. (D) mm Weight 170g max. LCD Type NSD-7446 ( F-STN / Black &White-mode / Transflective ) Viewing Angle 6:00 Control LSI T6963C-0101 (Produced by TOSHIBA) Data Transfer 8 bit parallel data transfer Backlight Electro Luminescence (EL) / White Drawings Dimensional Outline DMF5005NF-SEW (BB) No.2000-0190 OPTREX UE-31806B OPTREX CORPORATION Page 2/17 2.Electrical Specif ications 2.1.Absolute Maximum Ratings VSS=0V Parameter Supply Voltage Symbol Conditions Min. Max. Units VCC-VSS -0.3 7.0 V VCC-VEE 0 28.0 V VI -0.3 VCC+0.3 V (Logic) Supply Voltage (LCD Drive) Input Voltage 2.2.DC Characteristics Ta=25, VSS=0V Parameter Supply Voltage Symbol Conditions Min. Typ. Max. Units VCC-VSS 4.5 5.5 V (Logic) Supply Voltage VCC-VEE Shown in 3.1 V (LCD Drive) High Level VIH VCC=5.0V10% VCC-2.2 VCC V VIL VCC=5.0V10% 0 0.8 V VOH IOH=-0.75mA VCC-0.3 VCC V VOL IOL=0.75mA 0 0.3 V ICC VCC-VSS=5.0V 12.5 20.0 mA IEE VCC-VEE=13.3V 3.0 10.0 mA Input Voltage Low Level Input Voltage High Level Output Voltage Low Level Output Voltage Supply Current DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 3/17 2.3.AC Characteristics VCC=5.0V10% Parameter C/D Setup Time C/D Hold Time CE, RD, WR Pulse Width Data Setup Time Data Hold Time Access Time Output Hold Time Symbol Min. Max. Units tCDS tCDH tCE, tRD, tWR tDS tDH tACC tOH 100 ns 10 ns 80 ns 80 ns 40 ns 150 ns 10 50 ns C/D tCDS tCDH CE tCE, tRD, tWR RD, WR tDS tDH D0D7 (WRITE) tACC tOH D0D7 (READ) DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 4/17 2.4.Power Supply ON/OFF Sequence 2.4.1.ON Sequence SIGNAL LEVEL VCC VSS VCC 0t SIGNAL (Without RESET Signal) VCC VSS 0t VCC VSS VEE VEE 2.4.2.OFF Sequence LEVEL SIGNAL VCC VSS VCC 0t VCC VSS SIGNAL (Without RESET Signal) 0t VCC VSS VEE VEE 2.4.3.Reset Sequence SIGNAL LEVEL H Level RESET T0 T>250s L Level T10 ms VCC VCC T50ms T0 T50ms T0 VSS VCC VEE VEE Power On Reset Reset Cancellation Power Off Please maintain the above sequence when turning on and off the power supply of the module. If VEE is supplied to the module while internal alternate signal for LCD driving (M) is unstable or RESET is active, DC component will be supplied to the LCD panel. This may cause damage to the LCD module. DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 5/17 2.5.Lighting Specifications 2.5.1.Absolute Maximum Rating Ta=25 Parameter Input Voltage Input Frequency Conditions Min. Typ. Max. Units 150 Vrms AC100Vrms 800 Hz 2.5.2.Operating Characteristics Ta=25 Parameter Conditions Min. Typ. Max. Units Input Voltage 100 Vrms Input Frequency 400 Hz Current AC100Vrms, 400Hz 6.8 8.8 mA Luminance of AC100Vrms, 400Hz 34 43 cd/ AC100Vrms, 400Hz 2000 hrs Backlight Surface Life Ta=20, 60%RH Recommended Inverter : NS-106 ( DC 5.0V10%, Produced by NEC ) DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 6/17 3.Optical Specif ications 3.1.LCD Driving Voltage Parameter Symbol Recommended LCD Driving Voltage Note 1 : VCC-VEE Conditions Min. Typ. Max. Units Ta= 0 15.6 V Ta=25 12.4 13.3 14.2 V Note 1 Ta=50 11.2 V Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range. 3.2.Optical Characteristics Ta=25, 1/64 Duty, 1/9 Bias, VD=13.3V (Note 4), = 0 , = Parameter Contrast Ratio Symbol Conditions Min. Typ. Max. CR = 0 , = 7 Note 1 Viewing Angle Response Units Shown in 3.3 Rise Note 2 TON 70 140 ms Time Decay Note 3 TOFF 330 500 ms Note 1 : Contrast ratio is definded as follows. CR = LOFF / LON LON : Luminance of the ON segments LOFF : Luminance of the OFF segments Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 : Definition of Driving Voltage VD Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is definded as follows. VD = (Vth1+Vth2) / 2 Vth1 : The voltage VO-P that should provide 50% of the saturation level in the luminance at the segment which the ON signal is applied to. Vth2 : The voltage VO-P that should provide 50% of the saturation level in the luminance at the segment which the OFF signal is applied to. VO-P ( B-2 )xVO-P / B 1 / ( fFxA ) 1 / fF ON SIGNAL DMF5005NF-SEW (BB) No.2000-0190 OFF SIGNAL OPTREX OPTREX CORPORATION Page 7/17 3.3.Definition of Viewing Angle and Optimum Viewing Area Point shows the point where contrast ratio is measured. : = 0 , = Driving condition : 1/64 Duty, 1/9 Bias, VD=13.3V, fF=70Hz 90 45 135 180 10 20 30 40 50 90 (= 0 180 225 315 270 270 Area 0 shows typ. CR2 3.4.System Block Diagram Temperature Chamber Rotation Table (,) Photometer #1980A WB LCD Optical Fiber Computer Control Unit & Waveform Generator Halogen bulb DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 8/17 4.I/O Terminal 4.1.Pin Assignment No. Symbol Level Function 1 FG Frame Ground 2 VSS Power Supply (0V, GND) 3 VCC Power Supply for Logic 4 VEE Power Supply for LCD Drive 5 WR H/L Write Signal L : Active 6 RD H/L Read Signal L : Active 7 CE H/L Chip Enable Signal L : Active 8 C/D H/L Write Mode H : Command Write L : Data Write Read Mode H : Status Read L : Data Read 9 NC 10 RESET H/L Reset Signal L : Reset 11 D0 H/L Display Data 12 D1 H/L Display Data 13 D2 H/L Display Data 14 D3 H/L Display Data 15 D4 H/L Display Data 16 D5 H/L Display Data 17 D6 H/L Display Data 18 D7 H/L Display Data 19 FS H/L Font Switch H : 6x8 dots L : 8x8 dots 20 NC Non-connection 21 EL Power Supply for EL 22 EL Power Supply for EL Non-connection 4.2.Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. VCC VEE VCC (+Voltage) Tr R1 VR MODULE R2 VEE (-Voltage) VSS VSS (0V) R1+R2+VR=1020K Tr=2SA1202 or equivalent DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 9/17 4.3.Block Diagram 8 64 Row Driver T6961B x 1 or equivalent D0D7 WR RD Control LSI LCDP 240 x 64 dots 3 5 240 CE 4 T6963C Column Driver T6A39 x 3 or equivalent C/D RESET FS X-tal 13 8 64K S-RAM VCC VSS Bias Circuit To LSI J FG VEE EL EL Backlight EL DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 10/17 5.Test No change on display and in operation under the following test condition. No. Parameter Conditions Notes 1 High Temperature Operating 502, 96hrs (operation state) 2 Low Temperature Operating 02, 96hrs (operation state) 3 3 High Temperature Storage 602, 96hrs 4 4 Low Temperature Storage -202, 96hrs 3, 4 5 Damp Proof Test 402, 9095%RH, 96hrs 3, 4 6 Vibration Test Total fixed amplitude : 1.5mm 5 Vibration Frequency : 1055Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state. F E G B D C A 60cm Concrete Surface Dropping method corner dropping A corner : once Edge dropping B,C,D edge : once Face dropping E,F,G face : once Note 1 : Unless otherwise specified, tests will be conducted under the following condition. Temperature : 205 Humidity : 655% Note 2 : Unless otherwise specified, tests will be not conducted under functioning state. Note 3 : No dew condensation to be observed. Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. Note 5 : Vibration test will be conducted to the product itself without putting it in a container. DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 11/17 6.Appearance Standards 6.1.Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45 against perpendicular line. 45 6.2.Definition of applicable Zones A Zone Bezel Flame B Zone C Zone A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 12/17 6.3.Standards No. 1 Parameter Black and Criteria (1) Round Shape White Spots, Foreign Substances Zone Acceptable Number Dimension (mm) A B C D 0.1 * * * 0.1 D 0.2 3 5 * 0.2 D 0.25 2 3 * 0.25 D 0.3 0 1 * 0.3 D 0 0 * D = ( Long + Short ) / 2 * : Disregard (2) Line Shape Zone X (mm) Acceptable Number Y (mm) A B C 0.03W * * * 2.0L 0.05W 3 3 * 1.0L 0.1 W 3 3 * 0.1 W X : Length Y : Width In the same way (1) * : Disregard Total defects shall not exceed 5. 2 Air Bubbles (between glass & polarizer) Zone Dimension (mm) Acceptable Number A B C D 0.3 * * * 0.3 D 0.4 3 * * 0.4 D 0.6 2 3 * 0.6 D 0 0 * * : Disregard Total defects shall not exceed 3. DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 13/17 No. 3 Parameter The Shape of Dot Criteria (1) Dot Shape (with Dent) 0.15 As per the sketch of left hand. (2) Dot Shape (with Projection) Should not be connected to next dot. (3) Pin Hole X (X+Y) / 20.2mm Y (Less than 0.1mm is no counted.) (4) Deformation (X+Y) / 20.2mm Y X Total acceptable number : 1/dot, 5/cell (Defect number of (4) : 1pc.) 4 Polarizer Scratches Not to be conspicuous defects. 5 Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not defective. 6 7 Complex Foreign Black spots, line shaped foreign substances or air bubbles between Substance Defects glass & polarizer should be 5pcs maximum in total. Distance between D0.2 : 20mm or more Different Foreign 0.2D : 40mm or more Substance Defects DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 14/17 7.Code System of Production Lot The production lot of module is specified as follows. Factory Number (Numeral) Factory Code (Alphabet) Production Week (15) Production Month (19, X, Y, Z) Production Year (Lower 2 digits) 8.Type Number The type number of module is specified on the back of module as follows. Stamp Etching or Printing 9.Applying Precautions Please contact us when questions and/or new problems not specified in this specifications arise. DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 15/17 10.Precautions Relating Product Handling The Following precautions will guide you in handling our product correctly. 1) Liquid crystal display devices The liquid crystal display device panel used in the liquid crystal display module is made of plate glass. Avoid any strong mechanical shock. Should the glass break handle it with care. The polarizer adhering to the surface of the LCD is made of a soft material. Guard against scratching it. 2) Care of the liquid crystal display module against static electricity discharge. When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock. Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other conductivity-treated fibers. Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity. 3) When the LCD module alone must be stored for long periods of time: Protect the modules from high temperature and humidity. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays. Protect the modules from excessive external forces. 4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the module is not provided with this protective feature. 5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap. 6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity. 7) For models which use CFL: High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns. Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life. DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 16/17 8) For models which use touch panels: Do not stack up modules since they can be damaged by components on neighboring modules. Do not place heavy objects on top of the product. This could cause glass breakage. 9) For models which use COG,TAB,or COF: The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces. Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact. 10) Models which use flexible cable, heat seal, or TAB: In order to maintain reliability, do not touch or hold by the connector area. Avoid any bending, pulling, or other excessive force, which can result in broken connections. 11.Warranty This product has been manufactured to your company's specifications as a part for use in your company's general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement. We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company's acceptance inspection procedures. When the product is in CFL models, CFL service life and brightness will vary according to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise. We cannot accept responsibility for intellectual property of a third party, which may arise through the application of our product to your assembly with exception to those issues relating directly to the structure or method of manufacturing of our product. Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later. DMF5005NF-SEW (BB) No.2000-0190 OPTREX OPTREX CORPORATION Page 17/17