660VDC FERRULE FUSES /SPECIAL PURPOSE SIZE: 27X60 Features/Benefits Ratings 0.8 to 110 Amps Full Range D.C. operation 660VDC at 50kA I.R. 4R=15mSec 27x60mm ceramic cylindrical body Blown Fuse indicator striker Underwriters Recognized component Dimensions 60,3 60,3 7mm 7 O 27 indicator travel O5mm 5 27 Indicator Trip Force: 4.5N at 0mm-2.5N at 7mm G APPLICATIONS DATA SIZE 27 x 60 CURRENT RATING IN(A) 0.8 1 1.5 2 3.15 4 5 6.3 8 10 12 16 20 25 32 40 50 63 80 100 110 INTERRUPTING RATING @ 660V DC 50kA L/R = 15ms WATTS LOSS 0.8 IN IN 0.25 0.25 0.35 0.4 0.6 0.6 0.7 0.8 1.2 1.3 1.4 1.9 2.4 2.8 3.5 4.7 4.8 5.6 6.4 7.4 7.7 0.4 0.4 0.6 0.7 1 1 1.1 1.3 2 2.3 2.4 3.3 4.1 4.7 6 8 8.3 9.6 11.2 12.9 13.7 Minimum trip voltage: 20V G 33 CATALOG NUMBER CC 6,621 CPgRB 27x60/0.8 CC 6,621 CP gRB 27x60/1 CC 6,621 CP gRB 27x60/1.5 CC 6,621 CP gRB 27x60/2 CC 6,621 CP gRB 27x60/3.15 CC 6,621 CP gRB 27x60/4 CC 6,621 CP gRB 27x60/5 CC 6,621 CP gRB 27x60/6.3 CC 6,621 CP gRB 27x60/8 CC 6,621 CP gRB 27x60/10 CC 6,621 CP gRB 27x60/12 CC 6,621 CP gRB 27x60/16 CC 6,621 CP gRB 27x60/20 CC 6,621 CP gRB 27x60/25 CC 6,621 CP gRB 27x60/32 CC 6,621 CP gRB 27x60/40 CC 6,621 CP gRB 27x60/50 CC 6,621 CP gRB 27x60/63 CC 6,621 CP gRB 27x60/80 CC 6,621 CP gRB 27x60/100 CC 6,621 CP gRB 27x60/110 REF. NUMBER H098585 J098586 K098587 P098591 Q098592 R098593 T098595 Z098600 L076301 M076302 L075703 N076303 C077006 M075635 P076304 Q076305 R076306 P079961 S079964 T099400 S076307 1000V DC FERRULE FUSES /SPECIAL PURPOSE SIZE: 20X127 Features/Benefits Ratings 6 to 63 Amps Full Range D.C. operation 1000VDC at 100kA I.R. LR=20Sec 20x127mm ceramic cylindrical body Blown Fuse indicator striker Dimensions 7mm indicator travel 127mm CC 1591 20.6 5 Weight: 87 g Indicator Trip Force: 4.5N at 0mm-2.5N at 7mm APPLICATIONS DATA SIZE 20 x 127 CURRENT RATING IN(A) INTERRUPTING RATING WATTS LOSS 0.8 IN IN CATALOG NUMBER REF. NUMBER 6 2.0 3.5 CC 1051 CP gRB 20x127/6 D 100 gRB 006 VI Z 088020 8 2.2 3.8 CC 1051 CP gRB 20x127/8 D 100 gRB 008 VI T 088774 10 2.4 4.2 CC 1051 CP gRB 20x127/10 D 100 gRB 010 VI A 089493 12 3.0 5.3 CC 1051 CP gRB 20x127/12 D 100 gRB 012 VI B 089493 3.7 6.6 CC 1051 CP gRB 20x127/16 D 100 gRB 016 VI C 089495 4.4 7.7 CC 1051 CP gRB 20x127/20 D 100 gRB 020 VI D 089496 25 5.1 9 CC 1051 CP gRB 20x127/25 D 100 gRB 025 VI E 089497 32 6.0 10.5 CC 1051 CP gRB 20x127/32 D 100 gRB 032 VI F 089498 40 7.3 13.2 CC 1051 CP gRB 20x127/40 D 100 gRB 040 VI S 086795 50 8.5 15.5 CC 1051 CP gRB 20x127/50 D 100 gRB 050 VI F 086186 63 * 9.6 17.4 CC 1051 CP gRB 20x127/63 D 100 gRB 063 VI F 083656 16 20 @ 1000V DC 100kA L/R = 20ms Minimum trip voltage: 50 V *Use R.M.S. current less than 56 A when mounting in fuse holder. G 34 PACK 10 pieces 1000V DC FERRULE FUSES /SPECIAL PURPOSE DC Voltage Capabilities vs. Time Constant Peak Arc voltage vs. working voltage L/R (ms) 1200 1100 1000 900 800 700 90 80 70 60 50 40 30 20 10 0 1-L/R = 50ms 2-L/R = 25ms 3-L/R = 15ms Above: Curve indicates the maximum permissible value of time constant L/R as a function of DC working voltage. Max. AC voltage (50/60 Hz): 1500V with interrrupting rating of 100kA. Above: Curves indicate for various time constants L/R the peak arc voltage, which may appear across the fuse terminals, vs. DC working voltage. G Melting Time-Current Data 10 4 8 10 12 16 20 25 32 40 50 63 6 t (s) 10 3 10 2 10 + 9% tolerance for mean - 1 pre-arcing current 10-1 10-2 10-3 10-4 1 10 10 2 10 3 I(A) Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. G 35 10 4 1500V DC FERRULE FUSES /SPECIAL PURPOSE SIZE: 20X127 Features/Benefits Ratings CC 1551 CP gRB CC I551 CP gRB Blown Fuse indicator striker 0.8 to 5 Amps 1000vdc at 100kA L/R=100mSec 20x127 ceramic cylindrical body CC 1500 CP gRB Full range D.C. operation 0.8 to 5 Amps Underwriters Component 1000vdc 30kA L/R=30mSec CC 1500 CP gRB Dimensions CC 1500 CP gRD 20x127 ceramic cylindrical body 6 to 25amps 127 Full range DC operation 1500vdc at 30kA L/R=55mSec 7 mm indicator travel CC 1500 EP gRD 5 20.6 20x127 ceramic cylindrical body Weight: 87g Full range DC operation Indicator Trip Force: 4.5N at 0mm-2.5N at 7mm - when so equipped* APPLICATIONS DATA SIZE 20 x 127 CURRENT RATING IN(A) 0.8 1 1.5 2 3.15 4 5 0.8 1 1.5 2 3.15 4 5 6 8 10 12 16 20 25 INTERRUPTING RATING WATTS LOSS 0.8 IN IN NEW @ 1000V DC 100kA L/R = 100ms @ 1000V DC 30kA L/R = 30ms @ 1500V DC 30kA L/R = 55ms 0.5 0.5 0.8 0.9 1.2 1.3 1.4 0.5 0.5 0.8 0.9 1.2 1.3 1.4 3.4 3.3 3.5 3.9 5 5.3 6.6 0.9 0.9 1.4 1.6 2.1 2.1 2.3 0.9 0.9 1.4 1.6 2.1 2.1 2.3 6.3 6.0 6.1 6.8 8.9 9.6 12 REF. NUMBER CATALOG NUMBER CC 1551 CP gRB 20x127/0.8 CC 1551 CP gRB 20x127/1 CC 1551 CP gRB 20x127/1.5 CC 1551 CP gRB 20x127/2 CC 1551 CP gRB 20x127/3.15 CC 1551 CP gRB 20x127/4 CC 1551 CP gRB 20x127/5 CC 1500 CP gRB 20x127/0.8 CC 1500 CP gRB 20x127/1 CC 1500 CP gRB 20x127/1.5 CC 1500 CP gRB 20x127/2 CC 1500 CP gRB 20x127/3.15 CC 1500 CP gRB 20x127/4 CC 1500 CP gRB 20x127/5 CC 1500 CP gRD 20x127/6 CC 1500 CP gRD 20x127/8 CC 1500 CP gRD 20x127/10 CC 1500 CP gRD 20x12712 CC 1500 CP gRD 20x127/16 CC 1500 CP gRD 20x127/20 CC 1500 CP gRD 20x127/25 *Minimum trip voltage: 50V G 36 PACK OLD D 150 gRB 0.8 VI D 150 gRB 001 VI D 150 gRB 01.5 VI D 150 gRB 002 VI D 150 gRB 3.15 VI D 150 gRB 004 VI D 150 gRB 005 VI D 150 gRB 0.8 V D 150 gRB 001 V D 150 gRB 01.5 V D 150 gRB 002 V D 150 gRB 3.15 V D 150 gRB 004 V D 150 gRB 005 V D 150 gRB 006 V D 150 gRB 008 V D 150 gRB 010 V D 150 gRB 012 V D 150 gRB 016 V D 150 gRB 020 V D 150 gRB 025 V E075743 E075744 G075745 B088367 H075746 J075747 C088368 J081842 R079894 K081843 Y099243 L081844 Z099244 A099245 E082804 Z080867 F081655 B080593 Q081457 D082803 A080431 3 and 10 pieces 1500V DC FERRULE FUSES/SPECIAL PURPOSE DC Application Data gRD L/R (ms) 4000 1 3000 3 2 2000 4 Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage. 2000 1500 1000 500 0 2600 2200 1800 1400 1000 1000 U (V) Curve 1: gRD @ L/R = 30ms Curve 2: gRB @ L/R = 60ms Curve 3: gRD @ L/R = 15ms Curve 4: gRB @ L/R = 30ms Max. AC voltage (50/60 Hz): 2500V with interrrupting rating of 50kA. Above: Curves indicate for various time constants L/R peak arc voltage, which may appear across the fuse terminals, vs. DC working voltage. G Time vs. current characteristics a=130 A2=0.6 B1=1.25 B2=0.6 Cf3=0.8 10 3 10 2 8 10 12 16 20 25 gRB without trip indicator 6 3.15 4 5 10 4 gRB with indicator 0.8 1 1.5 2 3.15 4 5 gRB without trip indicator t (s) 0.8 1 1.5 2 gRB 90 80 70 60 50 40 30 20 10 0 Peak Arc voltage vs. working voltage a=130 A2=0.6 B1=1.25 B2=0.6 Cf3=0.8 a=130 A2=0.6 B1=1.25 B2=0.6 Cf3=0.8 10 1 10-1 10-2 10-3 10-4 1 10 10 2 10 3 1 10 10 2 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. 10 3 1 + 9% tolerance for mean - pre-arcing current G 37 10 10 2 10 3 I (A) 1500V DC FERRULE FUSES /SPECIAL PURPOSE SIZE: 20X190 Features/Benefits Ratings CC I591 CP gRC CC I59I CP gRC Blown Fuse indicator striker 6 to 32 Amps 1500vdc at 60kA L/R=40mSec 20x190 ceramic cylindrical body Full range D.C. operation CC 1500 CP gRC 6 to 32 Amps CC 1500 CP gRC 1500vdc 60kA L/R=40mSec Dimensions 20x190 ceramic cylindrical body Full range D.C. operation 7mm 190 20.6 5 Weight: 176 g Indicator Trip Force: 4.5N at 0mm - 2.5N at 7mm - when so equipped* APPLICATIONS DATA SIZE 20 x 190 CURRENT RATING IN(A) 6 8 10 12 16 20 25 32 6 8 10 12 16 20 25 32 INTERRUPTING RATING @ 1500V DC 60kA L/R = 40ms WATTS LOSS 0.8 IN IN 4.8 5.3 6.5 7.0 8.0 9.5 12 16 4.8 5.3 6.5 7.0 8.0 9.5 12 16 7.8 8.8 10.5 11.5 13 15 19.5 26 7.8 8.8 10.5 11.5 13 15 19.5 26 CATALOG NUMBER CC 1591 CP gRC 20x190/6 CC 1591 CP gRC 20x190/8 CC 1591 CP gRC 20x190/10 CC 1591 CP gRC 20x190/12 CC 1591 CP gRC 20x190/16 CC 1591 CP gRC 20x190/20 CC 1591 CP gRC 20x190/25 CC 1591 CP gRC 20x190/32 CC 1500 CP gRC 20x190/6 CC 1500 CP gRC 20x190/8 CC 1500 CP gRC 20x190/10 CC 1500 CP gRC 20x190/12 CC 1500 CP gRC 20x190/16 CC 1500 CP gRC 20x190/20 CC 1500 CP gRC 20x190/25 CC 1500 CP gRC 20x190/32 *Minimum trip voltage: 90V G 38 REF. NUMBER D083102 V083738 G087245 Y080429 N088378 Q087345 Z080430 G085911 Z089469 A089470 B089471 C089472 D089473 E089474 F089475 G089476 PACK 10 pieces AMP-TRAP(R) 1500V DC FERRULE FUSES /SPECIAL PURPOSE DC Application Data Peak Arc voltage vs. working voltage L/R (ms) Um (V) 90 80 70 60 50 40 30 20 10 0 4500 1 2 3000 1500 2000 1500 1000 500 0 2000 1800 1600 1400 1200 1000 0 U (V) U (V) Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage. 1-L/R = 45ms 2-L/R = 15ms Max. AC voltage (50/60 Hz): 2500V with interrrupting rating of 50kA. Above: Curves indicate for various time constants L/R peak arc voltage, which may appear across the fuse terminals, vs. DC working voltage. Time vs. current characteristics G 8 6 10 4 10 12 16 20 25 32 t (s) a=130 A2=0.6 B1=1.25 B2=0.6 Cf3=0.8 10 3 10 2 10 + 7% tolerance for mean - pre-arcing current 1 10-1 10-2 10-3 10-4 10 10 2 10 3 10 4 I (A) Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. G 39