SPECIFICATION CONTROL DRAWING
Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
Title:
SOLDERSHIELF SPLICE KIT,
FLEXIBLE, SINGLE SHIELD
Tyco Electronics reserves the right to amend this drawing at any
time. Users should evaluate the suitability of the product for their
application
Document No. B-600-3X
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN
MILLIMETERS.
INCH DIMENSIONS ARE SHOWN IN BRACKETS Rev.:
1 Rev. Date:
13-Jun-03
DRAWN BY:
mforonda CAGE CODE:
06090 Org. Date:
13-Jun-03 File name:
D030317 SCALE:
None SIZE: A SHEET:
1 of 1
If this document is printed it becomes uncontrolled. Check for the latest revision.
Product Rev Product Dimensions Cable Dimensions
Product
Name L
max øA
min øE øF
min M
min N
max
B-600-31 N/C
93.00
(3.660) 5.50
(0.217)
2.40 (0.094)
to
3.80 (0.150)
2.40
(0.094) 15.00
(0.590) 83.00
(3.270)
B-600-32 N/C
93.00
(3.660) 7.00
(0.276)
3.40 (0.134)
to
5.00 (0.197)
3.50
(0.137) 15.00
(0.590) 83.00
(3.270)
B-600-33 N/C
108.00
(4.250) 9.00
(0.354)
4.50 (0.177)
to
7.00 (0.276)
4.50
(0.177) 15.00
(0.590) 83.00
(3.270)
B-600-34 N/C
108.00
(4.250) 11.00
(0.433)
6.50 (0.256)
to
9.50 (0.374)
6.50
(0.256) 15.00
(0.590) 83.00
(3.270)
B-600-35 N/C
108.00
(4.250) 13.50
(0.531)
9.00 (354)
to
12.70 (0.500)
9.00
(0.354) 15.00
(0.590) 83.00
(3.270)
MATERIALS
1 INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified polyvinylidene fluoride.
2. SHIELD: Tin plated copper braid, fluxed and tinned at both ends.
3. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Sn63 per ANSI/J-STD-006.
FLUX: TYPE ROM1 per ANSI/J-STD-004.
APPLICATION
1. These parts are designed to provide an in-line splice between the shield of cables, rated for 135°C minimum, meeting the
dimensional criteria listed, having tin or silver-plated copper shields.
2. Temperature range: -55°C to +150°C.
3. Install using Tyco Electronics/Raychem-approved convection or infrared heating tools.
For best results, prepare
the cable as shown: