ZTL431/ZTL432 COST EFFECTIVE ADJUSTABLE PRECISION SHUNT REGULATOR Description Pin Assignments The ZTL431 and ZTL432 are three terminal adjustable shunt regulators offering excellent temperature stability and output current handling capability up to 100mA. The output voltage may be set to any chosen voltage between 2.5 and 20 volts by selection of two external divider resistors. (Top View) Cathode 3 1 Anode Ref The devices can be used as a replacement for zener diodes in many applications requiring an improvement in zener performance. 2 SOT23, SOT23F (ZTL431) The ZTL432 has the same electrical specifications as the ZTL431 but has a different pin out in SOT23 (F-suffix) and SOT23F (FF-suffix). (Top View) Ref 3 Both variants are available in two grades with initial tolerances of 1% and 0.5% for the A and B grades, respectively. 1 Anode Cathode 2 These are functionally equivalent to the TL431/TL432 except for maximum operation voltage, and have an ambient temperature range of -40C to +125C as standard. SOT23, SOT23F (ZTL432) (Top View) Features Temperature Range ................ -40C to +125C Reference Voltage Tolerance at +25C 0.5%.......................................B grade 1% .........................................A grade 0.2 Typical Output Impedance Sink Current Capability........ 1mA to 100mA Adjustable Output Voltage......VREF to 20V Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2) Halogen and Antimony Free. "Green" Device (Note 3) An Automotive-Compliant Part is Available Under Separate Datasheet (ZTL431AQ, ZTL431BQ, ZTL432AQ, ZTL432BQ) Cathode 1 N/C 6 Anode 2 5 N/C Ref 3 4 NC SOT363 Connected internally to substrate; should be left floating or connected to Anode (Top View) Cathode 1 5 N/C Anode 2 Applications Ref 3 Opto-Coupler Linearization Linear Regulators Improved Zener Variable Reference 4 N/C SOT25 (SE5 Package) (Top View) N/C 1 5 Anode N/C* 2 Cathode 3 4 Ref SOT25 (E5 Package) *must be left floating or connected to pin 5 Notes: 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated's definitions of Halogen and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green" products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. ZTL431/ZTL432 Document number: DS33263 Rev. 18 - 2 1 of 12 www.diodes.com August 2017 (c) Diodes Incorporated ZTL431/ZTL432 Absolute Maximum Ratings (Voltages specified are relative to the Anode pin unless otherwise stated.) Parameter Rating Unit Cathode Voltage (VKA) 20 V Continuous Cathode Current (IKA) 150 mA Reference Input Current Range (IREF) Operating Junction Temperature Storage Temperature -50A to +10mA -- -40 to +150 -55 to +150 C C Operation above the absolute maximum rating may cause device failure. Operation at the absolute maximum ratings, for extended periods, may reduce device reliability. Package Thermal Data Package JA PDIS TA = +25C, TJ = +150C SOT23 SOT23F SOT25 SOT363 380C/W 138C/W 250C/W 380C/W 330mW 900mW 500mW 330mW Recommended Operating Conditions (@TA = +25C, unless otherwise specified.) Symbol Parameter Min Max Unit VKA Cathode Voltage VREF 20 V IKA Cathode Current 1 100 mA TA Operating Ambient Temperature Range -40 +125 C Electrical Characteristics (@TA = +25C, unless otherwise specified.) Symbol Parameter VREF Reference Voltage VKA = VREF IKA = 10mA VDEV Deviation of Reference Voltage Over Full Temperature Range VKA = VREF IKA = 10mA VREF VKA Conditions ZTL43_A Min 2.475 Typ 2.5 Max 2.525 ZTL43_B 2.487 2.5 2.513 TA = 0 to +70C -- 6 16 TA = -40 to +85C -- 14 34 TA = -40 to +125C -- 14 34 VKA = VREF to 10V -- -1.4 -2.7 VKA = 10V to 20V -- -1.0 -2.0 -- 2 4 Unit V mV Ratio of Change In Reference Voltage To the Change In Cathode Voltage IKA = 10mA IREF Reference Input Current IKA = 10mA, R1 = 10k, R2 = O/C (Open Circuit) TA = 0 to +70C -- 0.8 1.2 IREF IKA = 10mA R1 = 10k IREF Deviation Over Full Temperature Range R2 = O/C (Open Circuit) TA = -40 to +85C -- 0.8 2.5 TA = -40 to +125C -- 0.8 2.5 Minimum Cathode Current for Regulation VKA = VREF -- -- 0.4 0.6 mA Off State Current VKA = 20V, VREF = 0V -- -- 0.1 0.5 A Dynamic Output Impedance VKA = VREF, f = 0Hz -- -- 0.2 0.5 IKA(MIN) IKA(OFF) RZ ZTL431/ZTL432 Document number: DS33263 Rev. 18 - 2 2 of 12 www.diodes.com mV/V A A August 2017 (c) Diodes Incorporated ZTL431/ZTL432 Typical Characteristics IKA = 10mA Reference Voltage vs. Temperature VREF = VKA Dynamic Impedance vs. Frequency Power Dissipation (mW) 1000 SOT23F 900 800 700 600 SOT25 SOT23-5 500 400 300 SOT23 SOT363 SC70-6 200 100 0 0 25 50 75 100 125 Ambient Temperature (C) Power Dissipation Derating ZTL431/ZTL432 Document number: DS33263 Rev. 18 - 2 3 of 12 www.diodes.com August 2017 (c) Diodes Incorporated ZTL431/ZTL432 Typical Characteristics (Cont.) VKA IKA 60 Gain (dB) 50 40 30 20 10 0 100 1000 10000 100000 1000000 Frequency (Hz) IKA Test Circuit for Open Loop Voltage Gain Gain vs. Frequency VKA VKA Pulse Response Test Circuit for Pulse Response VKA 100 Cathode Current (mA) 90 IKA 80 70 60 50 Stable Stable 40 30 20 10 0 10.0E-12 100.0E-12 1.0E-9 10.0E-9 100.0E-9 1.0E-6 Load Capacitance (F) Stability Boundary Condition ZTL431/ZTL432 Document number: DS33263 Rev. 18 - 2 VV <