108-5342-3
Rev A 2 of 12
3.3. Ratings
!
Temperature: -30 to 105
/
C
3.4. Perf ormance and Test Descript ion
Product is designed to meet the elect rical, mechanical and environmental per formance requirements
speci fied in Figure 2. Unless ot herwise specif ied, al l tests shall be per for med at room temperature.
3.5. Test Requirements and Procedur es Summary
Para Test Item Requirement Procedur e
3.5. 1 Confirmation of Product Product shall be conf ormi ng to
the r equirements of applicable
product drawing and Application
Speci ficat ions 114-5159 and
114-5160.
Vi sually, dimensionally and
funct ionally inspected per
appl icable quality inspect ion
plan.
ELECTRI CAL REQUIREMENTS
3.5. 2 Termination Resistance,
Speci fied Current .040II: 10 milliohms maximum
initial; 20 milliohms maximum
final.
.070II, III: 3 milliohms maximum
initial; 10 milliohms maximum
final.
Measure initial millivolt drop of
contact test circuit in mated
connector s. Figur e 3.
AMP Spec 109-5311- 2.
3.5. 3 Termination Resistance, Low
Level .040II: 10 milliohms maximum
initial; 20 milliohms maximum
final.
.070II, III: 3 milliohms maximum
initial; 10 milliohms maximum
final.
Subject mated contacts
assembled in housing to closed
circuit current of 10 milliamperes
maximum at open circuit voltage
of 20 millivolts maximum. Figure
3.
AMP Spec 109-5311- 1.
3.5. 4 Dielectric Strength No creeping discharge nor
flashover shall occur. 1 ki lovolt AC for 1 mi nute. Test
between adjacent circuits of
mated/unmated connectors.
AMP Spec 109-5301.
3.5. 5 Insulation Resist ance 100 megohms minimum. Impressed voltage 500 volts DC.
Test between adjacent circui ts of
mated connector s.
AMP Spec 109-5302.
3.5. 6 Current Leakage 1 milliampere maximum. 12 volts DC impressed 1 minute.
AMP Spec 109-5312.
3.5. 7 Temperature Rising 60
/
C maximum under specified
current. Measur e temperature rise by
energized current .
AMP Spec 109-5310.
3.5.8 Current Cycling .040II: 20 milliohms maximum
final.
.070II, III: 10 milliohms maximum
final.
No i gniti on allowed during test.
Appl ied current per Figur es 6
and 7. 45 mi nutes ON, 15
minut es OFF, 200 cy cles.
AMP Spec 109-5308.
Fi gure 1 ( continued)