For gas Digital Pressure Sensor DP-101(A) / 102(A) SERIES Ver. 2 Conforming to EMC Directive Recognition Certification [DP-101(A)/102(A) only] Pressure Sensor Evolutions To Come 2013.11 panasonic.net/id/pidsx/global Achieved further efficiency with 4 upgrades, keeping the same operability Note: The upgrade will be implemented from production in October 2013, based on stock status. Upgrade 1 Superior visibility Improved visibility in Digital Display Improvements to the digital display deliver a wide viewing angle along with increased clarity. The display pressure range and set pressure range have also been increased. Old DP-100 series New DP-100 series Upgrade 2 Long-distance transmission of analog output Addition of analog current output capability to multifunctional models Users can now select either voltage output or current output as analog output according to their application. Upgrade 3 Reduced environmental impact 14 % lower after update 14% lower power consumption (during normal operation) Thanks to a redesign of its circuitry, power consumption of the low-power-consumption DP-100 series during normal operation has been reduced by 14%. The display is shut off entirely during ECO / FULL mode operation for power savings of up to 50% compared to normal operation, and display brightness is lowered during ECO / STD mode operation for power savings of up to 30% compared to normal operation. Old DP-100 series New DP-100 series 840 mW (normal operation) 720 mW (normal operation) 50 Up to % lower in ECO mode Normal operation 720 mW ECO / FULL operation 360 mW Upgrade 4 Enhanced power circuitry Addition of a reverse polarity protection circuit to the transistor output circuit To prevent from breakage due to miswiring. 1 A new global standard Dual Display Direct setting "Current value" and "threshold value" can be checked at the same time! Current value Threshold value ect setting Dir Works like a dial control type sensor Main display Comparative Output 1 operation indicator Comparative Output 2 operation indicator Work as analog voltage output operation indicator in Multi-function type Mode selection key Dual display allows direct setting of threshold value Decrement key Increment key Previous model with single display Threshold value setting method Equipped with a 30 mm 1.181 in square compact-sized dual display. The current value and the threshold value can be checked at the same time, so the threshold value can be set and checked smoothly without switcing to another screen mode. ON / OFF operations still continue while the threshold values are being set, so setting to the same sensitivity as dial control-type sensors is possible. Key lock function is equipped as well. Sub display -91.8 Take a note on current value Operate MODE key Adjust threshold value Return to RUN operation DP-100 with dual display Simply press a button Man-hours reduced by during RUN operation 3/ 4 3-color display (Red, Green, Orange) Readable digital display! The main display changes color in line with changes in the status of output ON / OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be understood easily, and operating errors can be reduced. Alphanumeric indication in 12 segments is used. This improved visual checking. OFF: Green (or Red) ON: Red (or Green) SET: Orange Main Display During normal operation During setting 2 Copy function helps operation to be accurate and quick Copy function reduces man-hours and human error Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when machinery design are changed, there would be less change in work orders. Setting details can be copied. Copying via wiring Master sensor Slave sensor Power supply +V +V 0V 0V Comparative output 1 Comparative output 1 Comparative output 2 Comparative output 2 Details transmitted Details received Detail s cop ied Note: Settings cannot be copied from the new version (Ver. 2) to the old version. However, settings can be copied from the old version to the new version (Ver. 2). Advantage 1 Setting man-hours are reduced and sensor setting time is shortened. 4th equipment: 5 minutes approx. 3rd equipment: 5 minutes approx. 2nd equipment: 5 minutes approx. 1st equipment: Advantage 2 Number of pressure sensor: 1 unit per 1 equipment, 4 equipment per 1 line Reduction of lead time 20 seconds approx. 5 minutes approx. The setting details for the master sensor are retained, so continuous copying is possible. For 2nd and subsequent lines, the data transmission time only is required. 4th equipment: 3rd equipment: 2nd equipment: 1st equipment: Master sensor 5 minutes approx. 20 seconds approx. 4th equipment: 3rd equipment: 2nd equipment: 1st equipment: Sensor setting time: Sensor setting time: Sensor setting time: 20 minutes approx. 5 minutes 20 seconds approx. 20 seconds approx. Previously DP-100, 1st line DP-100, 2nd line Human operating error is reduced. Because all details are copied automatically, problems as a result of human error can be prevented. Instruction manuals can be updated easily when changes are made to equipment design. 3 Setting is smooth and easy The sensor's setting operation mode has a 3-level configuration to suit the frequency of use. The setting levels are clearly separated into "RUN mode" for operation settings that are carried out daily, "MENU SETTING mode" for basic settings, and "PRO mode" for special and detailed setting. These make setting operations easy to understand and easy to carry out. RUN mode Settings such as threshold value adjustment and key lock operation can be carried out while the sensor is operating. RUN mode Simple setting MENU SETTING mode MENU SETTING mode Basic settings such as output mode setting and NO / NC switching can be carried out. PRO mode Special and detailed setting PRO mode High-level function settings such as hysteresis adjustment and the copy function can be carried out. Displayed in orange while setting is in progress The display appears in red and green during RUN operation, but it changes to orange while setting is in progress, so that the sensor status can be viewed at a glance. RUN operation RUN mode While setting MENU SETTING mode PRO mode or Red or green when output is ON / OFF Orange while setting is in progress Default settings that can be used straight away Buttons with good clicking touch Easy-to-use default settings are provided for applications that are used frequently by pressure sensors. The default settings for low pressure types are ideal for suction confirmation applications, and those for high pressure types are ideal for checking reference pressure. The buttons have a good clicking touch, allowing smooth setting. Low pressure type Comparative output 1 Hysterisys 3digits ON High pressure type Comparative output 1 Ideal for checking suction Hysterisys 3digits Ideal for checking reference pressure OFF -100 kPa The clicking feeling is transmitted even through gloves. -50 kPa 0 kPa 0 MPa 0.5 MPa 1 MPa Reset function If a problem ever occurs with the sensor settings, they can be reset to the default settings. 4 Full range of performance and functions in a compact body All lineup models are compound pressure types High performance accomplished No sensor settings are required to switch between positive pressure and negative pressure, so that the number of registered part numbers can be decreased. Low pressure type The low pressure type displays measurements in 0.1 kPa at a resolution of 1/2,000 and has a response time of 2.5 ms (variable up to 5,000 ms), 0.5 % F.S. temperature characteristics and 0.1 % F.S. repeatability, achieving high detection performance. Ideal for applications such as suction. No misoperations due to vacuum breakdown occur. - 100 kPa For low pressure For high pressure 0 kPa DP-101 Resolution: 1/2,000 Response time: 2.5 ms Temperature characteristics: 0.5 % F.S. Repeatability: 0.1 % F.S. 100 kPa Ideal for applications such as checking reference pressure. Can also be used for simple suction. Displays measurements in 0.1 kPa 1 MPa DP-102 Equipped with independent dual output Standard type Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Since there are two comparative outputs, one of the comparative outputs can even be used for alarm output. In addition, output, which is not being used, can be disabled. Three output modes are suitable for a wide range of applications 1 - 100 kPa Comparative output 0 ON OFF H: Fixed Notes: 1) Hysteresis can be fixed to one of eight different levels. 2) " " appears in the sub display for comparative output 1, and " " appears for comparative output 2. 2 Vacuum breakdown checking P-1 0 kPa Comparative output 1 ON Hysteresis mode OFF Hysteresis mode This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON / OFF control. P-2 3 Lo-1 Hi-1 P-2 H: 1 digit or more " appears in the sub display for comparative " or " " appears for comparative output 2. Window comparator mode This mode is used for setting comparative output ON and OFF at pressures within the setting range. Pressure ON Comparative output 2 EASY mode OFF H (Hysteresis) Note: " " or " output 1, and " Reference pressure checking Alarm output Hi Lo 0 ON Comparative output OFF Reference pressure alarm output is possible during reference pressure checking! 0 kPa H (Hysteresis) P Suction checking Pressure ON Comparative output 2 EASY mode OFF Pressure Vacuum breakdown can also be notified during suction applications! ON Comparative output 1 EASY mode OFF EASY mode This mode is used for comparative output ON / OFF control. H (Hysteresis) Hi Lo 0 ON Comparative output OFF H (Hysteresis) H: Fixed Notes: 1) Hysteresis can be fixed to one of eight different levels. " or " " appears in the sub display for comparative 2) " output 1, and " " or " " appears for comparative output 2. 5 Equipped with auto-reference / remote zero-adjustment functions, More precise pressure management is achieved with a minimum of effort If the reference pressure of the device changes, two functions are selectable. One is auto-reference function, which partially shift the comparative output judgment level by the amount that the reference pressure shifts. The other is remote zero-adjustment function, which can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are required. Multi-function type Without auto-reference and remote zero-adjustment functions Comparative output: Window comparator mode Hi-1 30, Lo-1 25 Fixed set value 40 NG? 30 Leak threshold level 25 20 OK NG? 15 Variation in the filling pressure Trial 1 Trial 2 Trial 3 Pressure 0 Time Because the threshold level is fixed for conventional pressure sensors, changes in the reference pressure result in wrong decisions. With auto-reference function applied With remote zero-adjustment function applied Comparative output: Window comparator mode Hi-1 0, Lo-1 - 5 Comparative output: Window comparator mode Hi-1 0, Lo-1 - 5 Sets the absolute threshold level Sets the absolute threshold level Auto-reference input Remote zero-adjustment input The display is forced to "0", and only the filling pressure drop range is displayed. The display remains at "30" and only the threshold level is changed. 30 OK 25 20 Threshold level after applying auto-reference input 15 30 0 25 -5 OK 20 Threshold level after applying remote zero-adjustment input 15 Threshold level before applying remote zero-adjustment input Threshold level before applying auto-reference input Trial 1 Pressure 0 Trial 1 Pressure 0 Auto-reference input value -5 Time When auto-reference input is applied, the reference pressure "30" is added to the threshold level. If the reference pressure changes to "20" or "40", the auto-reference input compensates for this every time by changing the threshold level, so any variation in the filling pressure can be ignored. -5 Displayed when remote zeroadjustment input is applied Time When remote zero-adjustment input is applied, the reference pressure is forced to "0". If the reference pressure changes to "20" or "40", the remote zero-adjustment input adjusts the reference pressure to "0" every time the reference pressure changes, so any variation in the filling pressure can be ignored. Peak hold and Bottom hold functions Energy-saving design! Equipped with an ECO mode The peak values and bottom values for fluctuating pressures can be displayed using the dual display. This mode lowers the display luminance to cut power consumption by approximately 30 %. The displays can also be turned off completely to achieve a power saving of approximately 40 %. Power consumption Normal Approx. Power consumption Approx. ECO-STD 30 % less ECO-FULL 40 % less Current consumption for 24 V power supply: 25 mA or less Current consumption for 24 V power supply: 20 mA or less Blinks alternately Current consumption for 24 V power supply: 35 mA or less 6 Other useful functions Sub display can be customized Setting details can be recognized at a glance The sub display can be set to indicate any other desired values or letters apart from the threshold value. This eliminates the need for tasks such as affixing a label to the device to indicate the normal pressure value. The DP-100 setting details appear in the digital display. Because the settings are in numeric form that can be easily understood, it is useful such as when receiving technical support by telephone. What are the check codes for the setting? The code on the main display is 3205. The sub display shows 7011. 2nd digit: Setting status for comparative output 2 3rd digit: Threshold value setting 1st digit: Setting status for comparative output 1 4th digit: Display color setting Indicates desired values and letters 5th digit: Response time setting 8th digit: ECO mode setting 7th digit: Display refresh rate setting 6th digit: Display unit setting Cable can be connected with one-touch Connector attached cable (2m 6.562 ft), as an accessory, can be connected easily with one-touch connection. Types without connector attached cable are also available DP-10-J Commercially-available connectors can be used for cable connections. Cables in required length can be used, so this contributes to reduction in waste of unwanted cables. Environmentally friendly Commercially-available parts can be used! Connection cable * * Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available. M8 plug-in connector types are also available (Only for Europe) Mating cable CN-24A-C2 (cable length 2 m 6.562 ft) CN-24A-C5 (cable length 5 m 16.404 ft) M8 connector G 1/8 male thread M5 female thread 7 DP-11-E-P-J Installation is also easy! Tight installation to panels is possible An exclusive mounting bracket that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available. Tight installation is possible Neat and space saving Front protection cover available MS-DP1-3 A single mounting hole! An exclusive mounting bracket that supports tight installation is available Space savings can also be achieved even when an L-shaped mounting bracket is used. MS-DP1-1 Tight installation is possible MS-DP1-5 Ceiling mounting Floor mounting Positioning bosses for easier mounting bracket installation Rear mounting Short pressure port type is lightweight and takes up little space Space saving! Light weight of 30 g! * Compact size with a depth of only 30 mm 1.181 in, so that it can easily fit into narrow spaces. 10 g lighter than standard types. This reduces the loads on movable parts such as robot arms. Short pressure port type DP-10-M Standard type M5 female thread+R1 8 male thread Elbow joint * Excluding cables with connector attached Short pressure port type Shortened to 12.5 mm 0.492 in ! Light weight 30g approx. 30 mm 1.181 in Ideal for clean environments! Stainless steel (SUS303) which does not rust or generate gas is used as the port material. M5 female thread [Material: Stainless steel (SUS)] * The illustration shows connection using an elbow joint. The elbow joint is sold separately. 8 DP-100 Flat installation on the wall by shifting the direction For short pressure port type of the pressure port Rc1/8 conversion bushing is available. Compatible For short pressure port type with previous model By mounting the flat attachment to DP-10-M(-P), pressure port and cable can now be pulled out in downward, left or right directions. Flat mounting on surfaces such as the wall is made possible. By equipping the push-in converter with DP-10-M(-P), pressure port can be converted from M5 female thread to Rc1/8 female thread. Bore diameter conversion to the DP2 / DP3 series is possible. Previous model DP2 / DP3 series can be switched over to DP-100 series. Previous model Flat attachment 06'3) 20 mm 0.787 in pitch Model No. MS-DP1-FM M5 female thread Rc1/8 female thread 20 mm 0.787 in pitch Conversion bushing MS-DP1-7 Pressure port M5 female thread MS-DP1-FR Rc1/8 female thread MS-DP1-FN NPT1/8 female thread MS-DP1-FE G1/8 female thread 3 possible directions to mount ORDER GUIDE Type Asia Standard Multi-function M8 plug-in connector type Europe Multi-function Standard Multi-function North America Standard pressure port type Standard Appearance Model No. For low pressure i100.0 to +100.0 NPa DP-101 For high pressure i0.100 to +1.000 MPa DP-102 For low pressure i100.0 to +100.0 NPa DP-101A For high pressure i0.100 to +1.000 MPa DP-102A For low pressure i100.0 to +100.0 NPa DP-101-E-P For high pressure i0.100 to +1.000 MPa DP-102-E-P For low pressure i100.0 to +100.0 NPa For high pressure i0.100 to +1.000 MPa For low pressure i100.0 to +100.0 NPa DP-111-E-P-J For high pressure i0.100 to +1.000 MPa DP-112-E-P-J For low pressure i100.0 to +100.0 NPa For high pressure i0.100 to +1.000 MPa For low pressure i100.0 to +100.0 NPa Standard For high pressure For low pressure * CN-14A-C2 Connector attached cable 2 m 6.562 ft is attached. Excluding M8 plug-in connector type ( ( Multi-function For high pressure For low pressure i0.100 to +1.000 MPa ) i100.0 to +100.0 NPa ) i0.100 to +1.000 MPa i100.0 to +100.0 NPa Standard For high pressure i0.100 to +1.000 MPa Asia Short pressure port type Rated pressure range For low pressure i100.0 to +100.0 NPa Multi-function For high pressure i0.100 to +1.000 MPa Pressure port Comparative output M5 female thread + NPN open-collector transistor R 1/8 male thread M5 female thread + PNP open-collector transistor G 1/8 DP-101A-E-P male thread DP-102A-E-P M5 female thread + PNP open-collector transistor G 1/8 DP-111A-E-P-J male thread DP-112A-E-P-J DP-101-N NPN open-collector transistor DP-101-N-P PNP open-collector transistor NPN open-collector transistor M5 female thread PNP open-collector transistor + NPT 1/8 NPN open-collector transistor DP-101A-N male thread PNP open-collector transistor DP-101A-N-P DP-102-N DP-102-N-P DP-102A-N NPN open-collector transistor DP-102A-N-P PNP open-collector transistor DP-101-M NPN open-collector transistor DP-101-M-P PNP open-collector transistor DP-102-M NPN open-collector transistor DP-102-M-P M5 female thread PNP open-collector transistor DP-101A-M NPN open-collector transistor DP-101A-M-P PNP open-collector transistor DP-102A-M NPN open-collector transistor DP-102A-M-P PNP open-collector transistor Type without connector attached cable Type without connector attached cable CN-14A-C2 is available. When ordering this type, suffix "-J" to the end of Model No. (e.g.) Type without connector attached cable of DP-101-N is "DP-101-N-J" Accessory CN-14A-C2 (Connector attached cable 2 m 6.562 ft) 9 DP-100 OPTIONS Connector attached cable Designation Model No. Description &1$& &1$5& CN-14A-C1 CN-14A-C2 (Note) CN-14A-C3 CN-14A-C5 CN-14A-R-C1 CN-14A-R-C2 CN-14A-R-C3 CN-14A-R-C5 Length: 1 m 3.281 ft M8 connector attached cable CN-24A-C2 Length: 2 m 6.562 ft CN-24A-C5 For M8 plug-in connector type The connector on one end Length: 5 m 16.404 ft Cable outer diameter: o4 mm o0.157 in Connector CN-14A Set of 10 housings and 40 contacts Sensor mounting bracNet MS-DP1-1 Allows sensors to be installed on the flooring or ceiling. Multiple sensors can also be mounted closely. MS-DP1-5 Allows sensors to be installed on the wall. Multiple sensors can also be mounted closely. MS-DP1-2 Allows installation to panels with thicNness of 1 to 6 mm 0.039 to 0.236 in. Multiple sensors can also be mounted closely. MS-DP1-4 Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed set-up, please use panel mounting bracNet MS-DP1-2 for panel mounting. Front protection cover MS-DP1-3 Protects the adjustment surfaces of sensors. (Can be attached when using the panel mounting bracNet) Conversion bushing MS-DP1-7 By equipping with DP-10-M(-P), pressure port can be converted to Rc1/8 female thread. Replacement from DP2 / DP3 series is possible. Flat attachment MS-DP1-FM MS-DP1-FR MS-DP1-FN MS-DP1-FE Connector attached cable Connector attached cable (Flexible cable) Panel mounting bracNet Length: 2 m 6.562 ft Length: 3 m 9.843 ft 0.2 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: o3.7 mm o0.146 in Length: 5 m 16.404 ft Length: 1 m 3.281 ft Length: 2 m 6.562 ft Length: 3 m 9.843 ft 0.2 mm2 4-core flexible cabtyre cable with connector on one end Cable outer diameter: o3.7 mm o0.146 in Length: 5 m 16.404 ft M8 connector attached cable &1$& 31.4 1.236 o9 o0.354 (Unit: mm in) M5 female thread Pressure port and cable can now be pulled out in downward, left or right NPT1/8 female thread directions. Flat mounting on surfaces such as the wall is made possible. G1/8 female thread Rc1/8 female thread Sensor mounting bracket MS-DP1-1 M3 (length 6 mm 0.236 in) screws with washers Accessory for MS-DP1-1 Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series. (Excluding M8 plug-in connector type). ( MS-DP1-2 MS-DP1-3 MS-DP1-4 DP2 / DP3 Front protection cover DPX-04 (optional) can be installed on MS-DP1-4. ) Sensor mounting bracNet MS-DP1-1 Panel mounting bracket, Front protection cover DP 2-2 0 n101 .3kP a OUT 1 OUT 2 0-AD J Front protection cover MS-DP1-3 MOD E Remove Remove MS-DP1-5 Insert Panel mounting bracNet MS-DP1-2 M3 (length 6 mm 0.236 in) screws with washers Accessory for MS-DP1-5 Mounting holes for DP2 / DP3 series can be used as is. DP-100 ( ) Panel mounting bracNet MS-DP1-4 Sensor mounting bracNet MS-DP1-5 Flat attachment MS-DP1-FM o4 o0.157 MS-DP1-FR MS-DP1-FN MS-DP1-FE Net weight: MS-DP1-FM 15g approx. MS-DP1-FR/FN/FE 25g approx. Two M3 (length 8 mm 0.315 in) screws, two M4 (length 20 mm 0.787 in) screws are attached. Conversion bushing MS-DP1-7 M5 female thread Rc1/8 female thread Recommended connector Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Recommended crimping tool Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.) Conversion bushing MS-DP1-7 Note: Contact the manufacturer for details of the recommended products. 10 DP-100 SPECIFICATIONS Standard Item Model No. Type For low pressure DP-101(-M)(-P) DP-101-E-P DP-111-E-P-J DP-101-N(-P) Asia (Note 2) Europe M8 plug-in connector type North America (Note 2) Multi-function For low pressure For high pressure DP-101A(-M)(-P) DP-102A(-M)(-P) DP-101A-E-P DP-102A-E-P DP-111A-E-P-J DP-112A-E-P-J DP-101A-N(-P) DP-102A-N(-P) For high pressure DP-102(-M)(-P) DP-102-E-P DP-112-E-P-J DP-102-N(-P) Type of pressure Gauge pressure i100.0 to +100.0 kPa i101.0 to +101.0 kPa i1.030 to +1.030 kgf/cm2 i1.010 to +1.010 bar i14.64 to +14.64 psi i757 to +757 mmHg i29.8 to 29.8 inHg Rated pressure range Set pressure range 500 kPa Pressure withstandability i0.100 to +1.000 MPa i0.101 to +1.010 MPa i101 to +1,010 kPa i1.03 to +10.30 kgf/cm2 i1.01 to +10.10 bar i14.6 to +146.4 psi i100.0 to +100.0 kPa i101.0 to +101.0 kPa i1.030 to +1.030 kgf/cm2 i1.010 to +1.010 bar i14.64 to +14.64 psi i757 to +757 mmHg i29.8 to 29.8 inHg 1.5 MPa i0.100 to +1.000 MPa i0.101 to +1.010 MPa i101 to +1,010 kPa i1.03 to +10.30 kgf/cm2 i1.01 to +10.10 bar i14.6 to +146.4 psi 500 kPa 1.5 MPa Applicable fluid Non-corrosive gas Selectable unit For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi 12 to 24 V DC 10 % Ripple P-P 10 % or less Supply voltage Power consumption Comparative output Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage) 360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage) NPN open-collector transistor PNP open-collector transistor Ma[imum source current: 100 mA Ma[imum sink current: 100 mA Applied voltage: 30 V DC or less (between comparative output and +V) Applied voltage: 30 V DC or less (between comparative output and 0 V) Residual voltage: 2 V or less (at 100 mA sink current) Residual voltage: 2 V or less (at 100 mA source current) Output operation / Output modes NO / NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode Hysteresis Minimum 1 digit (variable) (however, 2 digits when using psi unit) Repeatability 0.1 % F.S. (within 2 digits) Response time 0.2 % F.S. (within 2 digits) 0.1 % F.S. (within 2 digits) 0.2 % F.S. (within 2 digits) 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation Short-circuit protection Incorporated ON voltage: 0.4 V DC or less OFF voltage: 5 to 30 V DC, or open ,nput impeGance: 0 N appro[. Input time: 1 ms or more E[ternal input (Note 3) Auto-reference function / Remote zero-adjustment function ON voltage: 5 V to +V DC OFF voltage: 0.6 V DC or less, or open Input impeGance: 10 N appro[. Input time: 1 ms or more Analog voltage output (Note 3) Output voltage: 1 to 5 V DC Zero point: within 3 V 5 % F.S. Span: within 4 V 5 % F.S. Linearity: within 1 % F.S. Output impeGance: 1 N appro[. Output voltage: 0.6 to 5 V Zero point: within 1 V 5 % F.S. Span: within 4.4 V 5 % F.S. Linearity: within 1 % F.S. Output impeGance: 1 N appro[. Analog current output (Note 3) Output current: 4 to 20 mA Zero point: 12 mA 5 % F.S. Span: 16 mA 5 % F.S. Linearity: within 1 % F.S. LoaG resistance: 250 (ma[.) Output current: 2.4 to 20 mA Zero point: 4 mA 5 % F.S. Span: 17.6 mA 5 % F.S. Linearity: within 1 % F.S. LoaG resistance: 250 (ma[.) Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) i101.0 to +101.0 kPa i101.0 to +101.0 kPa i0.101 to +1.010 MPa i0.101 to +1.010 MPa i1.030 to +1.030 kgf/cm2 i101 to +1,010 kPa i1.030 to +1.030 kgf/cm2 i101 to +1,010 kPa i1.010 to +1.010 bar i1.010 to +1.010 bar i1.03 to +10.30 kgf/cm2 i1.03 to +10.30 kgf/cm2 i14.64 to +14.64 psi i14.64 to +14.64 psi i1.01 to +10.10 bar i1.01 to +10.10 bar i757 to +757 mmHg i757 to +757 mmHg i14.6 to +146.4 psi i14.6 to +146.4 psi i29.8 to 29.8 inHg i29.8 to 29.8 inHg Displayable pressure range Environmental resistance Indicator ( Orange LED Comparative output 1 operation indicator, comparative output 2 operation indicator: Lights up when each comparative output is ON Protection Ambient temperature Ambient humidity Voltage withstandability Orange LED Comparative output 1 operation indicator: Lights up when comparative output is ON, Analog voltage output operation indicator: Lights up when setting )( ) IP40 (IEC) i10 to +50 C +14 to +122 F, Storage: i10 to +60 C +14 to +140 F 35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 50M or more with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 3 mm 0.118 in amplitude, in X, Y and Z directions for two hours each (when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude, in X, Y and Z directions for two hours each) Shock resistance 100 m/s2 acceleration (10 G appro[.) in X, Y and Z directions for three times each Temperature characteristics Within 0.5 % F.S. (at +20 C +68 F) Pressure port Asia: M5 female thread + R (PT) 1/8 male thread >e[cluding DP--M(-P)], Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread Within 1 % F.S. (at +20 C +68 F) Within 0.5 % F.S. (at +20 C +68 F) Within 1 % F.S. (at +20 C +68 F) Material Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber Connecting method / Cable length Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable Weight Accessories Net weight: 40 g appro[. (DP-10-M(-P): 30 g appro[.), Gross weight: 135 g appro[. (DP-10-M(-P):125 g appro[.) CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (e[cluding M8 plug-in connector type) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) Model Nos. of Asia type having "-M are short pressure port type. Model Nos. of Asia and North America types having the suffi[ "-P" are PNP output type. 3) Cannot be used at the same time. 11 DP-100 I/O CIRCUIT AND WIRING DIAGRAMS DP-10 NPN output type Terminal No. I/O circuit diagram Standard type D2 2 Tr1 ZD1 D3 3 5V (Brown) +V (Black) Load Comparative output 1 Load 100 mA ma[. (White) Comparative output 2 + i 12 to 24 V DC 10 % Sensor circuit D1 Sensor circuit Color code of connector attached cable Color code of connector attached cable 1 Tr2 Multi-function type Terminal No. Tr1 Tr2 3 D2 1k 2 Internal circuit (Blue) 0 V Internal circuit Users' circuit Load (Black) Comparative output 1 + i 12 to 24 V DC 10 % 100 mA ma[. 4 4 (White) Analog output or E[ternal input ZD1 100 mA ma[. ZD2 1 D1 D3 (Brown) +V (Blue) 0 V Users' circuit Symbols D1, D2 : Reverse supply polarity protection diode ZD1 : Surge absorption zener diode Tr1 : PNP input transistor Tr2 : NPN output transistor Symbols D : Reverse supply polarity protection diode ZD1, ZD2 : Surge absorption zener diode Tr1, Tr2 : NPN output transistor Terminal arrangement diagram Terminal Designation 1 +V Comparative output 1 2 2 3 DP-10-P 4 3 Standard type: Comparative output 2 Multi-function type: Analog output or E[ternal input 4 0V PNP output type Terminal No. I/O circuit diagram Multi-function type Terminal No. Standard type Color code of connector attached cable 1 Sensor circuit Tr1 100 mA ma[. ZD2 Tr2 2 (Black) Comparative output 1 100 mA ma[. Load 3 (White) Comparative output 2 Load (Blue) 0 V 4 Internal circuit (Brown) +V D1 D ZD1 Color code of connector attached cable 1 (Brown) +V Users' circuit Symbols D : Reverse supply polarity protection diode ZD1, ZD2 : Surge absorption zener diode Tr1, Tr2 : PNP output transistor + i 12 to 24 V DC 10 % Sensor circuit 1 ZD1 Tr1 100 mA ma[. 2 D3 1k Tr2 3 D2 4 Internal circuit (Black) Comparative output 1 (White) Analog output Load or E[ternal input + i 12 to 24 V DC 10 % (Blue) 0 V Users' circuit Symbols D1, D2 : Reverse supply polarity protection diode ZD1: Surge absorption zener diode Tr1 : PNP output transistor Tr2 : NPN input transistor Terminal arrangement diagram Terminal 1 2 3 4 Designation 1 +V 2 Comparative output 1 3 Standard type: Comparative output 2 Multi-function type: Analog output or E[ternal input 4 0V 12 DP-100 I/O CIRCUIT AND WIRING DIAGRAMS '3(3- PNP output type I/O circuit diagram Color code of connection cable Standard type (Brown) +V 1 ZD1 100 mA max. Tr1 4 ZD2 Tr2 + (Black) Comparative output 1 100 mA max. Load 2 (White) Comparative output 2 Load (Blue) 0 V i 12 to 24 V DC 10 % ZD1 Tr1 100 mA max. 4 1k i Tr2 D2 12 to 24 V DC 10 % (White) Analog voltage output Load 2 or External input Internal circuit Users' circuit + (Black) Comparative output 1 3 3 Internal circuit Sensor circuit 1 D1 (Brown) +V D Sensor circuit Terminal No. Color code of connection cable Multi-function type Terminal No. (Blue) 0 V Users' circuit Symbols D1, D2 : Reverse supply polarity protection diode ZD1: Surge absorption zener diode Tr1 : PNP output transistor Tr2 : NPN input transistor Symbols D : Reverse supply polarity protection diode ZD1, ZD2 : Surge absorption zener diode Tr1, Tr2 : PNP output transistor Terminal arrangement diagram 1 2 4 3 Terminal Designation 1 +V 2 Standard type: Comparative output 2 Multi-function type: Analog output or External input 0V Comparative output 1 3 4 PRECAUTIONS FOR PROPER USE Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. The DP-100 series is designed for use with non-corrosive gas. It cannot be used with liquid or corrosive gas. Mounting MS-DP1-1/MS-DP1-5 sensor mounting brackets are available separately, and it should be used for mounting. When tightening the sensor to the sensor mounting bracket, use a tightening torque of 0.5 N*m or less. M3 (length 6 mm 0.236 in) screws with washers Accessory for MS-DP1-1 and MS-DP1-5 ( ) Wiring Make sure that the power supply is off while wiring. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Incorrect wiring will cause problems with operation. Connection Do not apply stress directly to the connection cable leader or to the connector. Connector attached cable [CN-14A(-R)-C] Sensor mounting bracket MS-DP1-1 (Optional) The MS-DP1-2 panel mounting bracket (optional) and the MS-DP1-3 front protection cover (optional) are also available. Front protection cover MS-DP1-3 (optional) Conditions in use for CE conformity The DP-100 series is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN 61000-6-2 and the following condition must be met to conform to that standard. Condition The line to connect with this sensor should be less than 30 m 98.425 ft. 13 Panel mounting bracket MS-DP1-2 (optional) DP-100 PRECAUTIONS FOR PROPER USE Mounting Piping The MS-DP1-4 panel mounting bracket is available when switching from the DP2 / DP3 series. If connecting a commercially-available coupling to the pressure port, attach a 12 mm 0.472 in spanner (14 mm 0.551 in spanner for DP-100-E type) to the hexagonal section of the pressure port to secure it, and tighten at a torque of 9.8 N*m or less. If it is tightened using excessive torque, it may damage the coupling or the pressure port. In addition, wrap sealing tape around the coupling when connecting it to prevent leaks. DP2 / DP3 DP 2-2 0 n10 1.3k Pa Front protective cover DPX-04 (Optional) can be installed on MS-DP1-4. OUT 1 Remove OUT $' - 2 MO DE Remove Insert DP-100 Mounting holes for DP2 / DP3 series can be used as is. Panel mounting bracket MS-DP1-4 If connecting a commercially-available joint to the pressure port of the DP-10-M, hold the main unit in your hand to steady it, and tighten to a torque of 1.0 N*m or less. If it is tightened to an excessive torque, the joint or the main unit may become damaged. If connecting a commercially-available joint to the pressure port of the MS-DP1-7, tighten to a torque of 9.8 N*m or less. An conversion bushing is available for when using the DP-10-M short pressure port type. It can be used to switch between this model and the DP2 / DP3 series. When connecting to the pressure port, use a tightening torque of 1.0 N*m or less. M5 female thread Rc 1 8 female thread Conversion bushing MS-DP1-7 The MS-DP1-F flat attachment is available. If using the MS-DP1-F flat attachment (optional), install by following the procedures given below. Decide the direction of this product to mount with the sensor. 12 mm 0.472 in spanner 14 mm 0.551 in spanner The tightening torque should be 1 N*m or less when connecting a coupling to the pressure port of MS-DP1-FM. Pressure port Coupling (Purchase separately.) Pressure port faces downward Pressure port faces leftward Pressure port faces rightward Note: It is not possible to mount this product such that the pressure port faces upward. When connecting the coupling to the pressure port of MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm 0.551 in spanner and make sure that the tightening torque is 9.8 N*m or less. In addition, in order to prevent any leakage, wind a sealing tape on the coupling when connecting. Pressure port faces upward Mount this product with the M3 female threads of the sensor by using the attached M3 (length 8 mm 0.315 in) screws. The tightening torque should be 0.5 N*m or less. M3 female thread 14 mm 0.551 in spanner M3 (length 8 mm 0.315 in) screw (Accessory) M3 female thread Note: Do not tighten the pressure port by holding the product with the spanner. It may cause the product breakage. Mount this product with the mounting surface by using the attached M4 (length 20 mm 0.787 in) screws. The tightening torque should be 1.2 N*m or less. Flat attachment Groove Connector attached cable M4 (length 20 mm 0.787 in) screw (Accessory) Note: Take care that if the cable with connector is sticking out of the side groove of this product when mounting, the cable may disconnected. Make sure to mount MS-DP1-F with the sensor properly. If it is not mounted properly, air leakage may occur. Take care that the excessive mounting and dismounting of this product may cause deterioration of the O-ring. If you touch the O-ring of MS-DP1-F, or any scratch or dust, etc. is attached to it, air leakage may occur and the sensing performance may deteriorate. Take sufficient care when using and storing MS-DP1-F. 14 DP-100 PRECAUTIONS FOR PROPER USE Others PRO mode This product has been developed / produced for industrial use. Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on. Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the keys with pointed or sharp objects. If the mode selection key is pressed and held for 5 seconds in RUN mode, the mode will switch to PRO mode. If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. RUN mode 7KLVLVWKHQRUPDORSHUDWLQJPRGH Setting item Description Threshold value setting The threshold values for ON / OFF operation can be changed directly by pressing the increment key (UP) and the decrement key (DOWN). Zero-adjustment function This forces the pressure value display to be reset to zero when the pressure port is open on the atmospheric pressure side. Key lock function Stops key operations from being accepted. Peak hold / bottom hold function Displays the peak value and bottom value for fluctuating pressure. The peak value appears in the main display, and the bottom value appears in the sub display. Setting item Description Sub display switching Changes the information in the sub display during RUN mode operation to the desired alphanumeric display. Display refresh rate switching Changes the display refresh rate for the pressure value displayed in the main display. Hysteresis fix value switching Sets the hysteresis for EASY mode and window comparator mode. (8 steps) Linked display color switching (standard type only) Allows the display color for the main display to be switched in line with the output operation for comparative output 1 or comparative output 2. ECO mode setting Allows power consumption to be reduced by dimming the display or turning it off. Setting check code Allows the setting details to be checked via codes. Setting copy mode Allows the setting details for the master sensor to be copied to slave sensors. Reset setting Resets the settings to the factory settings. Table of codes If the mode selection key is pressed and held for 2 seconds in RUN mode, the mode will switch to MENU SETTING mode. If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. Setting item Comparative output 1 output mode setting Code 2nd digit MENU SETTING mode 1st digit NO NC Sets normally open (NO) or normally closed (NC). Response time setting Sets the response time. The response time can be selected from 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms and 5,000 ms. Display color switching for main display Allows the color for the main display to be changed. The colors can be set to `red / green' or `green / red' to correspond to ON / OFF output, or it can be fixed at `red' or `green' all the time. Unit switching Pressure unit can be changed. 15 NO NO NC NC NO Hysteresis Hysteresis Window comparator Code NO / NC switching OFF EASY Comparative output 2 output mode Sets the output mode for comparative output 2. setting (standard type only) Allows switching between analog voltage output / analog current output, and auto-reference input / remote zero-adjust-ment input. OFF EASY Sets the output mode for comparative output 1. Multi-function 3rd digit type 4th digit Standard type only Comparative output 1 NO / NC Comparative output 2 NO / NC Analog voltage output / Threshold Display color for Display output mode switching output mode switching External input value display main display color linking Description Analog output / external input switching (multi-function type only) Standard type NO NC -- -- -- -- 5th digit Response time 2.5 ms 5 ms 10 ms 25 ms 50 ms 100 ms 250 ms 500 ms 1,000 ms 5,000 ms Window comparator -- Analog voltage P-1, Lo-1 output Red when ON Autoreference Hi-1 Comparative output 1 Remote zero-adjustment P-2, Lo-2 Green when ON Analog current Hi-2 output Comparative output 1 NC -- ADJ. NO -- -- NC -- -- -- -- -- 6th digit Unit switching MPa kPa kgf/cm2 bar psi mmHg inchHg -- -- -- 7th digit Display refresh rate 250 ms 500 ms 1,000 ms -- -- -- -- -- -- -- Comparative output 2 Comparative output 2 Comparative Always output 1 red Comparative output 2 Comparative Always output 1 green Comparative output 2 8th digit ECO mode OFF STD FULL -- -- -- -- -- -- -- DP-100 DIMENSIONS (Unit: mm in) DP-10 The CAD data in the dimensions can be downloaded from the website. Sensor 42.5 1.673 30 1.181 25.5 1.004 20 0.787 7.5 9.5 0.295 0.374 12 0.472 20 0.787 30 1.181 R (PT) 1/ 8 male thread (North America: NPT 1/ 8) 1.5 0.059 Connector M5 female thread M3 female thread, 4 0.157 deep Europe Europe 10 7 0.394 0.276 14 0.551 G 1/ 8 male thread DP-10-M(-P) Sensor 30 1.181 30 1.181 25.5 1.004 20 0.787 4.5 0.177 20 0.787 o8.3 o0.327 30 1.181 1.5 0.059 connector M5 female thread, 4 0.157 deep M3 female thread, 4 0.157 deep DP-11-E-P-- Sensor 30 1.181 47.5 1.870 25.5 1.004 20 0.787 7 0.276 9.5 0.374 30 1.181 20 0.787 M8 connector 14 0.551 4.5 0.177 G 1/8 male thread 1.5 0.059 15 0.591 7 0.276 M5 female thread M3 female thread, 4 0.157 deep 16 DP-100 DIMENSIONS (Unit: mm in) MS-DP1-1 The CAD data in the dimensions can be downloaded from the website. Sensor mounting bracket (Optional) o2.3 o0.091 1 0.039 22 0.866 30 1.181 20 0.787 13 0.512 14.5 0.571 4.2 0.165 2-o3.5 o0.138 25.5 1.004 42.5 1.673 9.5 0.374 7.5 0.295 5.3 (0.209 ) 5.5 0.217 20 0.787 45 1.772 44 1.732 30 1.181 45 1.772 12 0.472 30 1.181 15 0.591 Sensor mounting bracket (Optional) 1.5 0.059 30 1.181 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Two M3 (length 6 mm 0.236 in) screws with washers are attached. MS-DP1-5 2-R2.1 R0.083 9.5 0.374 2-R2.1 R0.083 R13 20 0.787 R0.512 t2 t 0.079 Mounting drawing with DP-1 22 0.866 9.5 14.5 0.571 0.374 4.2 0.165 Assembly dimensions t2 t 0.079 Assembly dimensions Mounting drawing with DP-1-M R6.75 R0.266 22.75 0.896 29.5 1.161 20 0.787 4.5 0.177 16 0.630 o4.5 o0.177 28 1.102 8.5 0.335 30 1.181 4.5 0.177 44.5 30 1.752 1.181 20 0.787 13.5 0.531 20 0.787 2-o3.5 o0.138 49.5 (1.949 ) o4.5 o0.177 20 0.787 29.5 1.161 30 1.181 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Two M3 (length 6 mm 0.236 in) screws with washers are attached. MS-DP1-2 MS-DP1-3 o8.3 o0.327 20 49.5 0.787 28.5 1.949 1.122 t 1.5 t 0.059 1.5 0.059 28 1.102 53.5 2.106 4.5 0.177 t 1.5 t0.059 Panel mounting bracket (Optional), Front protection cover (Optional) Assembly dimensions Mounting drawing with '3 Panel cut-out dimensions When 1 unit is installed 0 31i 0 1.220 i0.016 0 39.3 ( 1.547 ) 34.5 1.358 ( 34.5 20 1.358 0.787 7.2 0.283 11 0.433 18.3 7.5 0.720 0.295 Front protection cover ) 50 1.969 33.4 1.315 When "n" units are installed horizontally in series When "n" units are installed vertically in series 0 31i 0 1.220 i0.016 31 1.220 Xn + 3.5 0.138 X (n-1) 12 0.472 0 31i 0 1.220 i0.016 55 2.165 or more M5 female thread, 4 0.157 deep (52 2.047 max) M3 female thread, 4 0.157 deep View A Material: POM (Panel mounting bracket) Polycarbonate (Front protection cover) 31 1.220 Xn + 3.5 0.138 X (n-1) Panel thickness dimension 1 to 6 mm 0.039 to 0.236 in Connector 33.4 1.315 17 9.5 0.374 R(PT) 1/ 8 male thread 8.7 0.343 31i 0 1.220 i0.016 55 2.165 or more Note: The panel thickness should be 1 to 6 mm 0.039 to 0.236 in. Note: The panel thickness should be 1 to 6 mm 0.039 to 0.236 in. DP-100 DIMENSIONS (Unit: mm in) MS-DP1-4 The CAD data in the dimensions can be downloaded from the website. Panel mounting bracket (Optional) Assembly dimensions Panel cut-out dimensions Mounting drawing with DP-10 ( 42.7 1.681 40 1.575 30 1.181 ) ( 9.7 0.382 36 1.417 26.5 1.043 6.5 0.256 3 0.118 ) Front protection cover (DPX-04) Panel thickness dimension 1 to 3.2 mm 0.039 to 0.126 in MS-DP1-7 36 +0.5 0 1.417+0.020 0 Connector R 1/ 8 male thread 80 3.150 12 0.472 42.7 1.681 40 30 1.575 1.181 56 2.205 Panel mounting bracket body 8 0.315 Panel mounting bracket 36 +0.5 0 1.417+0.020 0 M5 female thread Spacer Note: The panel tickness should be 1 to 32 mm 0.039 to 1.260 in. Material: Panel mounting bracket body Nylon 6 Panel mounting bracket Stainless steel (SUS304) Spacer Cold rolled carbon steel (SPCC)(Uni-chrome plated) Conversion bushing (Optional) 15.8 0.622 14 0.551 3.5 0.138 ( 7.8 0.307 0.5 0.020 11 0.433 M5 male thread Gasket ) 8 0.315 10 0.394 Rc1/8 female thread Material: Brass (Nickel plated) Weight: 10 g approx. MS-DP1-FM Flat attachment (Optional) MS-DP1-FR/FN/FE Flat attachment (Optional) Assembly dimensions Assembly dimensions Mounting drawing with DP-10-M ( ) 44.5 1.752 24 0.945 ( Mounting drawing with DP-10-M 52.5 ( 2.067 ) 24 (0.945 ) 37 1.457 11.5 0.453 ) 30 1.181 44.5 1.752 11 0.433 24 0.945 6.5 0.256 5.5 0.217 13.5 0.531 24 0.945 M5 female thread 20 0.787 24 0.945 30 1.181 17.5 0.689 Material: Enclosure Polybutylene terephthalate (PBT) (Glass fiber reinforced) Pressure port Stainless steel (SUS303) 8.5 0.335 O-ring Hydrogenated Nitrile Butadiene Rubber (H-NBR) Weight: 15 g approx. (flat attachment only) Two M3 (length 8 mm 0.315 in) screws, two M4 (length 20 mm 0.787 in) screws are attached. 2-o4.3 o0.169 Pressure port G1/8 female thread (Note) 11.5 0.453 11 0.433 30 1.181 52.5 2.067 6.5 0.256 5.5 0.217 2-o4.3 o0.169 37 1.457 14 0.551 20 0.787 24 0.945 30 1.181 Product distinguishing mark MS-DP1-FR: 0 line MS-DP1-FN: 1 line MS-DP1-FE: 2 line 17.5 0.689 8.5 0.335 Material: Enclosure Polybutylene terephthalate (PBT) (Glass fiber reinforced) Pressure port Stainless steel (SUS303) O-ring Hydrogenated Nitrile Butadiene Rubber (H-NBR) Weight: 25 g approx. (flat attachment only) Note: MS-DP1-FR has a Two M3 (length 8 mm 0.315 in) screws, two M4 Rc1/ 8 female thread. (length 20 mm 0.787 in) screws are attached. MS-DP1-FN has a NPT1/ 8 female thread. 18 DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website. CN-14A(-R)-C Connector attached cable (Optional, CN-14A-C2 is attached to the sensor) L 35 (1.378 ) Model No. 50 (1.969 ) (0.3158 ) (0.3158 ) o3.7 o0.146 cable Cable length L (mm in) CN-14A(-R)-C1 1,000 39.370 CN-14A(-R)-C2 2,000 78.740 CN-14A(-R)-C3 3,000 118.110 CN-14A(-R)-C5 5,000 196.850 Please contact .......... 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Global Sales Department Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 panasonic.net/id/pidsx/global All Rights Reserved (c) No. CE-DP100V2-5 November, 2013 Specifications are subject to change without notice. 2013 Printed in Japan