Digital Pressure Sensor
For gas
DP-101(A) / 102(A) SERIES Ver. 2
panasonic.net/id/pidsx/global
2013.11
Pressure Sensor Evolutions
To Come
Certification
[DP-101(A)/102(A) only]
Conforming to
EMC Directive Recognition
Superior visibility
Improvements to the digital display deliver a wide viewing
angle along with increased clarity. The display pressure
range and set pressure range have also been increased.
Achieved further efficiency with
4 upgrades, keeping the same
operability
Improved visibility in Digital Display
Enhanced power circuitry
Addition of a reverse polarity protection circuit to the
transistor output circuit
Long-distance transmission of analog output
Users can now select either voltage output or current output as analog output according to their
application.
To prevent from breakage due to miswiring.
Addition of analog current output capability to multifunctional models
Reduced environmental impact
Thanks to a redesign of its circuitry, power consumption of
the low-power-consumption DP-100 series during normal
operation has been reduced by 14%. The display is shut
off entirely during ECO / FULL mode operation for power
savings of up to 50% compared to normal operation, and
display brightness is lowered during ECO / STD mode
operation for power savings of up to 30% compared to
normal operation.
14% lower power consumption
(during normal operation)
Old DP-100 series
840 mW (normal operation)
New DP-100 series
720 mW (normal operation)
Normal operation
720 mW
ECO / FULL operation
360 mW
14% lower
after update
Up to 50% lower
in ECO mode
Old DP-100 series New DP-100 series
Note: The upgrade will be implemented from production in October 2013, based on stock status.
1
Upgrade 1
Upgrade 2
Upgrade 3
Upgrade 4
2
SET: OrangeOFF: Green (or Red) ON: Red (or Green)
During normal operation During setting
A new global standard
Main display
Sub display
Decrement key
Increment key
Mode selection key
Comparative Output 1 operation indicator
Comparative Output 2 operation indicator
Work as analog voltage output operation
indicator in Multi-function type
Works like a dial
control type sensor
Works like a dial
control type sensor
D
i
r
e
c
t
s
e
t
t
i
n
g
Main
Display
Dual display allows direct
setting of threshold value
Equipped with a 30 mm 1.181 in square
compact-sized dual display. The current
value and the threshold value can be
checked at the same time, so the
threshold value can be set and checked
smoothly without switcing to another
screen mode. ON / OFF operations still
continue while the threshold values are
being set, so setting to the same
sensitivity as dial control-type sensors is
possible. Key lock function is equipped
as well.
DP-100 with dual display
Previous model with single display
Take a note on current value
Operate MODE key
Adjust threshold value Return to RUN operation
Threshold value setting method
“Current value” and “threshold value”
can be checked at the same time!
Dual Display
Dual Display
Direct setting
Direct setting
Current value
Threshold value
Simply press a button
during RUN operation Man-hours reduced by
Man-hours reduced by 3/4
3/4
3-color display (Red, Green, Orange)
The main display changes color in line with changes in the
status of output ON / OFF operation, and it also changes color
while setting is in progress. The sensor status can therefore be
understood easily, and operating errors can be reduced.
Readable digital display!
Alphanumeric indication in 12 segments is used. This improved
visual checking.
-91.8
Details copied
Details transmitted
Details received
3
Copy function reduces man-hours and human error
Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data
to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when
machinery design are changed, there would be less change in work orders.
Copy function helps operation to be accurate and quick
Setting details can be copied.
+V
0 V
Comparative
output 1
Comparative
output 2
+V
0 V
Comparative
output 1
Comparative
output 2
Power supply Slave sensorMaster sensor
Note: Settings cannot be copied from the new version (Ver. 2) to the old version.
However, settings can be copied from the old version to the new version (Ver. 2).
Copying via wiring
5 minutes
approx.
Sensor setting time:
5 minutes 20 seconds approx.
Sensor setting time:
20 seconds approx.
Setting man-hours are reduced and sensor setting time is shortened.
1
Advantage
5 minutes
approx.
5 minutes
approx.
5 minutes
approx.
5 minutes
approx.
Sensor setting time:
20 minutes approx.
1st equipment: Master
sensor
1st equipment:
2nd equipment:
3rd equipment:
4th equipment:
2nd equipment:
3rd equipment:
4th equipment:
Previously DP-100, 1st line DP-100, 2nd line
20 seconds
approx.
1st equipment:
2nd equipment:
3rd equipment:
4th equipment:
20 seconds
approx.
Number of pressure sensor: 1 unit per 1 equipment, 4 equipment per 1 line
Human operating error is reduced.
2
Advantage
The setting details for the master sensor are
retained, so continuous copying is possible.
For 2nd and subsequent lines, the data
transmission time only is required.
Because all details are copied automatically, problems as a result of human error can be
prevented.
Instruction manuals can be updated easily when changes are made to equipment design.
Reduction
of lead time
4
The clicking feeling is
transmitted even through gloves.
The buttons have a good clicking touch,
allowing smooth setting.
The sensors setting operation mode has a 3-level
configuration to suit the frequency of use.
The setting levels are clearly separated into “RUN mode” for operation
settings that are carried out daily, “MENU SETTING mode” for basic settings,
and “PRO mode” for special and detailed setting. These make setting
operations easy to understand and easy to carry out.
Displayed in orange while setting is in progress
The display appears in red and green during RUN operation, but it changes to orange while setting is in progress, so that the sensor status
can be viewed at a glance.
Default settings that can be used straight away
Easy-to-use default settings are provided for applications that are
used frequently by pressure sensors. The default settings for low
pressure types are ideal for suction confirmation applications, and
those for high pressure types are ideal for checking reference
pressure.
Setting is smooth and easy
Simple setting
Low pressure type High pressure type
Settings such as threshold value
adjustment and key lock operation
can be carried out while the
sensor is operating.
Basic settings such as output
mode setting and NO / NC
switching can be carried out.
RUN operation While setting
RUN mode
MENU SETTING mode
PRO mode
or
Comparative output 1
ON
OFF
–100 kPa
50 kPa
Hysterisys 3digits
0 kPa
Comparative output 1
0 MPa 0.5 MPa
Hysterisys 3digits
1 MPa
MENU SETTING mode
RUN mode
High-level function settings such
as hysteresis adjustment and the
copy function can be carried out.
PRO mode
The clicking feeling is
transmitted even through gloves.
Ideal for
checking
suction
Ideal for
checking
reference
pressure
Red or green when output is ON / OFF Orange while setting is in progress
Reset function
If a problem ever occurs with the sensor settings, they can be reset
to the default settings.
RUN mode
PRO mode
MENU SETTING mode
Special and
detailed setting
Special and
detailed setting
Buttons with good clicking touch
5
Full range of performance and functions in a compact body
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2)
“ ” or “ ” appears in the sub display for comparative
output 1, and “ ” or “ ” appears for comparative output 2.
Note: “ ” or “ ” appears in the sub display for comparative
output 1, and “ ” or “ ” appears for comparative output 2.
For low
pressure
<For low pressure>
For high
pressure
All lineup models are compound pressure
types
No sensor settings are required to switch between positive pressure
and negative pressure, so that the number of registered part
numbers can be decreased.
High performance accomplished
The low pressure type displays measurements in 0.1 kPa at a
resolution of 1/2,000 and has a response time of 2.5 ms (variable up
to 5,000 ms), ±0.5 % F.S. temperature characteristics and ±0.1 %
F.S. repeatability, achieving high detection performance.
Ideal for applications such
as suction. No mis-
operations due to vacuum
breakdown occur.
Equipped with independent dual output
Equipped with two independent comparative outputs, and separate
sensing modes can be selected for each of them. Since there are
two comparative outputs, one of the comparative outputs can even
be used for alarm output. In addition, output, which is not being
used, can be disabled. This mode is used for comparative output ON / OFF control.
EASY mode
H (Hysteresis)
H: Fixed
P
0
ON
OFF
Comparative output
Pressure
Lo
Hi
0
ON
OFF
Comparative output
H (Hysteresis)
Pressure
H: 1 digit or more
H (Hysteresis)
H: Fixed
H (Hysteresis)
Comparative output
Lo
Hi
0
ON
OFF
Pressure
1
This mode is used for setting comparative output ON and OFF
at pressures within the setting range.
Window comparator mode
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “ ” appears in the sub display for comparative output 1,
and “ ” appears for comparative output 2.
3
This mode is used for setting comparative output hysteresis to
the desired level and for carrying out ON / OFF control.
Hysteresis mode
2
Low pressure type
Standard type
DP-101Ƒ
DP-102Ƒ
100 kPa 100 kPa
1 MPa
0 kPa
<For high pressure>
Ideal for applications such
as checking reference
pressure. Can also be used
for simple suction.
Resolution: 1/2,000
Response time: 2.5 ms
Temperature characteristics: ±0.5 % F.S.
Repeatability: ±0.1 % F.S.
Ɣ Vacuum breakdown can also be notified during
suction applications!
Ɣ Reference pressure alarm output is possible during
reference pressure checking!
Comparative output 1
EASY mode
Comparative output 2
EASY mode
ON
OFF
ON
OFF
100 kPa
0 kPa
P-1 0 kPa P-2
Vacuum breakdown checking
Suction checking
Comparative output 1
Hysteresis
mode
Comparative output 2
EASY mode
ON
OFF
ON
OFF
Lo-1 Hi-1 P-2
Reference
pressure
checking
Alarm output
Displays measurements in 0.1 kPa
Three output modes are suitable for a wide
range of applications
6
Equipped with auto-reference / remote zero-adjustment functions,
More precise pressure management is achieved with a minimum of effort
If the reference pressure of the
device changes, two functions
are selectable. One is
auto-reference function, which
partially shift the comparative
output judgment level by the
amount that the reference
pressure shifts. The other is
remote zero-adjustment
function, which can reset the
display value to zero via
external input. These functions
are ideal for places where the
reference pressure fluctuates
wildly, or where fine settings are
required.
Multi-function type
With auto-reference function applied
20
15
0
5
OK
Comparative output: Window comparator mode
Hi-1
0, Lo-1
5
30
Auto-reference input
Sets the absolute threshold level
The display remains at “30” and
only the threshold level is changed.
Threshold level before applying
auto-reference input
Trial 1
25
Time
Pressure
Auto-reference input value
Comparative output: Window comparator mode
Hi-1
0, Lo-1
5
Sets the absolute threshold level
With remote zero-adjustment function applied
20
15
0
5
OK
30
Remote zero-adjustment input
Threshold level before applying
remote zero-adjustment input
Threshold level after applying
remote zero-adjustment input
Trial 1
25
Time
Pressure
Displayed when remote zero-
adjustment input is applied

5
Without auto-reference and remote zero-adjustment functions
0
30
40
OK
NG?
NG?
25
Comparative output: Window comparator mode
Hi-1
30, Lo-1
25
Fixed set value
20
Leak threshold level
Variation in the filling pressure
15
Trial 1
Trial 2
Trial 3
Time
Pressure
The display is forced to “0”, and only the
filling pressure drop range is displayed.
0
Threshold level after applying
auto-reference input
Because the threshold level is fixed for conventional pressure sensors,
changes in the reference pressure result in wrong decisions.
When remote zero-adjustment input is applied, the reference pressure is forced to “0”.
If the reference pressure changes to “20” or “40”, the remote zero-adjustment input
adjusts the reference pressure to “0” every time the reference pressure changes, so
any variation in the filling pressure can be ignored.
When auto-reference input is applied, the reference pressure “30” is
added to the threshold level. If the reference pressure changes to “20” or
“40”, the auto-reference input compensates for this every time by changing
the threshold level, so any variation in the filling pressure can be ignored.
Energy-saving design! Equipped with an ECO mode
This mode lowers the display luminance to cut power consumption
by approximately 30 %. The displays can also be turned off
completely to achieve a power saving of approximately 40 %.
Peak hold and Bottom hold functions
The peak values and bottom values for fluctuating pressures can be
displayed using the dual display.
Blinks alternately
Normal
Current consumption for
24 V power supply:
35 mA or less
ECO-STD
Current consumption for
24 V power supply:
25 mA or less
ECO-FULL
Current consumption for
24 V power supply:
20 mA or less
Approx.
30 % less
Approx.
40 % less
Power consumption
Power consumption
7
Other useful functions
Indicates desired values and letters
Setting details can be recognized at a glance
The DP-100 setting details appear in the digital display. Because
the settings are in numeric form that can be easily understood, it is
useful such as when receiving technical support by telephone.
1st digit: Setting status for
comparative output 1
5th digit: Response time
setting
6th digit: Display unit setting
7th digit: Display refresh rate setting
8th digit: ECO mode setting
2nd digit: Setting status for
comparative output 2
3rd digit: Threshold value setting
4th digit: Display color setting
The code on the main display is 3205.
The sub display shows 7011.
What are the check
codes for the setting?
Cable can be connected with one-touch
Connector attached cable (2m 6.562 ft), as an accessory, can be
connected easily with one-touch connection.
Ɣ
Types without connector attached
cable are also available
Commercially-available connectors can be used for cable
connections. Cables in required length can be used, so this
contributes to reduction in waste of unwanted cables.
Connection cable *
DP-10Ƒ-J
Environmentally
friendly
Sub display can be customized
The sub display can be set to indicate any other desired values or
letters apart from the threshold value. This eliminates the need for
tasks such as affixing a label to the device to indicate the normal
pressure value.
* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft
types are also available.
Commercially-available
parts can be used!
Commercially-available
parts can be used!
<Desired letter display><Unit display><Number display>
Ɣ
M8 plug-in connector types are also available (Only for Europe)
M8 connector
G 1/8 male thread
M5 female thread
Mating cable
CN-24A-C2 (cable length 2 m 6.562 ft)
CN-24A-C5 (cable length 5 m 16.404 ft)
DP-11Ƒ-E-P-J
8
Installation is also easy!
Tight installation to panels is possible
An exclusive mounting bracket that is suitable for 1 to 6 mm 0.039
to 0.236 in panel thickness is available.
Short pressure port type is lightweight and takes up little space
Space saving!
Compact size with a depth of only 30 mm 1.181 in, so that it can
easily fit into narrow spaces.
Light weight of 30 g! *
10 g lighter than standard types. This reduces the loads on movable
parts such as robot arms.
Ideal for clean environments!
Stainless steel (SUS303) which does not rust or generate gas is
used as the port material.
Space savings can also be achieved even when an L-shaped mounting bracket is used.
Front protection
cover available
MS-DP1-3
Ceiling mounting Floor mounting Rear mounting
Neat and
space
saving
Positioning bosses for easier
mounting bracket installation
* Excluding cables with connector attached
A single mounting hole!
Tight installation is possible
Tight installation is possible
Ɣ
An exclusive mounting bracket that supports tight installation is available
Standard type
Short pressure port type
Shortened to
12.5 mm 0.492 in !
Light weight
30g approx.
Shortened to
12.5 mm 0.492 in !
Light weight
30g approx.
Elbow joint
Short pressure
port type DP-10Ƒ-M
30 mm
1.181 in
* The illustration shows connection using an elbow joint. The elbow joint is sold separately.
M5 female thread+R1 8 male thread
M5 female thread [Material: Stainless steel (SUS)]
MS-DP1-1 MS-DP1-5
DP-100
9
ORDER GUIDE
Accessory
CN-14A-C2
(Connector attached cable 2 m 6.562 ft)
Type without connector attached cable
Type without connector attached cable CN-14A-C2 is available. When ordering this type, suffix “-J” to the end of Model No.
(e.g.) Type without connector attached cable of DP-101-N is “DP-101-N-J
Standard pressure port type Short pressure port type
Asia
Europe
Asia North America
Standard
Multi-function
Standard
Multi-function
For low pressure
For high pressure
For low pressure
For high pressure
For low pressure
For high pressure
For low pressure
For high pressure
Standard
Multi-function
For low pressure
For high pressure
For low pressure
For high pressure
Rated pressure range Model No. Pressure portType
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
PNP open-collector transistor
M5 female thread
+
R 1/8
male thread
M5 female thread
+
G 1/8
male thread
M5 female thread
M5 female thread
+
G 1/8
male thread
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
Comparative output
DP-101
DP-102
DP-101A
DP-102A
DP-101-E-P
DP-102-E-P
DP-101A-E-P
DP-102A-E-P
DP-111-E-P-J
DP-112-E-P-J
DP-111A-E-P-J
DP-112A-E-P-J
DP-101-N
DP-101-N-P
DP-102-N
DP-102-N-P
DP-101A-N
DP-101A-N-P
DP-102A-N
DP-102A-N-P
DP-101-M
DP-101-M-P
DP-102-M
DP-102-M-P
DP-101A-M
DP-101A-M-P
DP-102A-M
DP-102A-M-P
Appearance
* CN-14A-C2
(
Connector attached
cable 2 m 6.562 ft
)
is attached.
(
Excluding M8 plug-in
connector type
)
Standard
Multi-function
For low pressure
For high pressure
For low pressure
For high pressure
M8 plug-in connector type
Standard
Multi-function
For low pressure
For high pressure
For low pressure
For high pressure
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
M5 female thread
+
NPT 1/8
male thread
Flat installation on the wall by shifting the direction
of the pressure port
By mounting the flat attachment
to DP-10
Ƒ
-M(-P), pressure port
and cable can now be pulled out
in downward, left or right
directions. Flat mounting on
surfaces such as the wall is
made possible.
For short pressure port type For short pressure port type
Rc1/8 conversion bushing is available. Compatible
with previous model
By equipping the push-in converter with DP-10
Ƒ
-M(-P), pressure
port can be converted from M5 female thread to Rc1/8
female thread.
Bore diameter conversion to the DP2 / DP3 series is possible.
MS-DP1-7
M5 female thread Rc1/8
female thread
Conversion bushing
Flat attachment
3 possible directions to mount
06'3)Ƒ
20 mm
0.787 in pitch
Previous model
Model No. Pressure port
MS-DP1-FM
MS-DP1-FR
MS-DP1-FN
MS-DP1-FE
M5 female thread
Rc1/8 female thread
NPT1/8 female thread
G1/8 female thread
Previous model DP2 / DP3
series can be switched over to
DP-100 series.
20 mm
0.787 in pitch
DP-100
10
Connector attached cable
&1$&Ƒ
&1$5&Ƒ
Panel mounting bracket, Front protection cover
MS-DP1-2
MS-DP1-3
Flat attachment
MS-DP1-FM MS-DP1-FR
MS-DP1-FN
MS-DP1-FE
MS-DP1-4
Recommended connector
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Recommended crimping tool
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
OPTIONS
M8 connector attached cable
&1$&Ƒ
MS-DP1-5
ø9
ø0.354 (Unit: mm in)
31.4
1.236 ø4
ø0.157
Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series.
(Excluding M8 plug-in connector type).
Sensor mounting bracket
MS-DP1-1
Conversion bushing
MS-DP1-7
Sensor mounting
bracNet
MS-DP1-1
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for
MS-DP1-1
()
Front protection cover
MS-DP1-3
Panel mounting bracNet
MS-DP1-2
DP-100
Panel mounting bracNet MS-DP1-4
DP2-20
ñ101.3kPa
OUT2OUT1
MODE
0-ADJ
DP2 / DP3
Insert
Remove
Remove
Mounting holes
for DP2 / DP3 series
can be used as is.
Front protection cover
DPX-04 (optional)
can be installed on
MS-DP1-4.
Sensor mounting
bracNet
MS-DP1-5
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for
MS-DP1-5
()
MS-DP1-FM 15g approx.
MS-DP1-FR/FN/FE 25g approx.
Net weight:
Two M3 (length 8 mm 0.315 in) screws,
two M4 (length 20 mm 0.787 in) screws are attached.
Conversion bushing
MS-DP1-7
M5 female
thread
Rc1/8
female
thread
Connector
attached cable
Connector
attached cable
(Flexible cable)
M8 connector
attached cable
Connector
Panel mounting
bracNet
Front protection
cover
Conversion
bushing
Flat
attachment
Sensor
mounting
bracNet
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
Set of 10 housings and 40 contacts
Model No.Designation Description
CN-14A-C1
CN-14A-C2
(Note)
CN-14A-C3
CN-14A-C5
CN-14A-R-C1
CN-14A-R-C2
CN-14A-R-C3
CN-14A-R-C5
CN-24A-C2
CN-24A-C5
CN-14A
MS-DP1-1
MS-DP1-5
MS-DP1-2
MS-DP1-4
MS-DP1-3
MS-DP1-7
MS-DP1-FM
MS-DP1-FR
MS-DP1-FN
MS-DP1-FE
0.2 mm
2
4-core cabtyre cable with
connector on one end
Cable outer diameter:
ø
3.7 mm
ø
0.146 in
0.2 mm
2
4-core flexible cabtyre cable
with connector on one end
Cable outer diameter:
ø
3.7 mm
ø
0.146 in
For M8 plug-in connector type
The connector on one end
Cable outer diameter: ø4 mm ø0.157 in
Allows sensors to be installed on the flooring or ceiling.
Multiple sensors can also be mounted closely.
Allows sensors to be installed on the wall. Multiple sensors
can also be mounted closely.
Allows installation to panels with thicNness of 1 to 6 mm 0.039
to 0.236 in. Multiple sensors can also be mounted closely.
Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed
set-up, please use panel mounting bracNet MS-DP1-2 for panel mounting.
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracNet)
Pressure port and cable can now be
pulled out in downward, left or right
directions. Flat mounting on surfaces
such as the wall is made possible.
By equipping with DP-10
Ƒ
-M(-P), pressure port can be converted to
Rc1/8 female thread. Replacement from DP2 / DP3 series is possible.
M5 female thread
Rc
1
/8 female thread
NPT1/8 female thread
G1/8 female thread
DP-100
SPECIFICATIONS
<
Asia (NPN output), North America (NPN output)
>
ON voltage: 0.4 V DC or less
OFF voltage: 5 to 30 V DC, or open
,nput impeGance: 0 appro[.
Input time: 1 ms or more
<
Asia (PNP output), Europe, North America (PNP output)
>
ON voltage: 5 V to
+
V DC
OFF voltage: 0.6 V DC or less, or open
Input impeGance: 10 appro[.
Input time: 1 ms or more
Output voltage: 1 to 5 V DC
Zero point: within 3 V
±
5 % F.S.
Span: within 4 V ±5 % F.S.
Linearity: within ±1 % F.S.
Output impeGance: 1 appro[.
Output voltage: 0.6 to 5 V
Zero point: within 1 V
±
5 % F.S.
Span: within 4.4 V ±5 % F.S.
Linearity: within ±1 % F.S.
Output impeGance: 1 appro[.
Output current: 4 to 20 mA
Zero point: 12 mA ±5 % F.S.
Span: 16 mA ±5 % F.S.
Linearity: within ±1 % F.S.
LoaG resistance: 250 ȍ (ma[.)
Output current: 2.4 to 20 mA
Zero point: 4 mA ±5 % F.S.
Span: 17.6 mA ±5 % F.S.
Linearity: within ±1 % F.S.
LoaG resistance: 250 ȍ (ma[.)
(
Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON
)
Orange LED Orange LED
(
Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting
)
Environmental resistance
í1.030 to +1.030 kgf/cm2
í1.010 to +1.010 bar
í14.64 to +14.64 psi
í757 to +757 mmHg
í29.8 to 29.8 inHg
Standard
For low pressure For high pressure
Multi-function
For low pressure For high pressure
í100.0 to +100.0 kPa
í101.0 to +101.0 kPa
í0.100 to +1.000 MPa í100.0 to +100.0 kPa í0.100 to +1.000 MPa
500 kPa 1.5 MPa 500 kPa 1.5 MPa
DP-101(-M)(-P)DP-102(-M)(-P)DP-101A(-M)(-P)DP-102A(-M)(-P)
DP-101-E-P DP-102-E-P DP-101A-E-P DP-102A-E-P
DP-111-E-P-J DP-112-E-P-J DP-111A-E-P-J DP-112A-E-P-J
DP-101-N(-P)DP-102-N(-P)DP-101A-N(-P)
Gauge pressure Type of pressure
Rated pressure range
Set pressure range
Pressure withstandability
Applicable fluid
Selectable unit
Supply voltage
Power consumption
Comparative output
Output operation / Output modes
Hysteresis
Repeatability
Response time
Short-circuit protection
E[ternal input (Note 3)
Auto-reference function /
Remote zero-adjustment
function
Analog voltage output (Note 3)
Analog current output (Note 3)
Display
Displayable pressure range
Indicator
Protection
Ambient temperature
Ambient humidity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Temperature characteristics
Pressure port
Material
Connecting method / Cable length
Weight
Accessories
Non-corrosive gas
For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)
360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage)
<Asia (NPN output), North America (NPN output)>
NPN open-collector transistor
Ma[imum sink current: 100 mA
Applied voltage: 30 V DC or less (between comparative output and 0 V)
Residual voltage: 2 V or less (at 100 mA sink current)
<Asia (PNP output), Europe, North America (PNP output)>
PNP open-collector transistor
Ma[imum source current: 100 mA
Applied voltage: 30 V DC or less (between comparative output and +V)
Residual voltage: 2 V or less (at 100 mA source current)
NO / NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode
Minimum 1 digit (variable) (however, 2 digits when using psi unit)
±0.2 % F.S. (within ±2 digits) ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits)±0.1 % F.S. (within ±2 digits)
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Incorporated
4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
í10 to +50 °C +14 to +122 °F, Storage: í10 to +60 °C +14 to +140 °F
35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50Mȍ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in amplitude, in X, Y and Z directions for two hours each (when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude, in X, Y and Z directions for two hours each)
100 m/s2 acceleration (10 G appro[.) in X, Y and Z directions for three times each
Within ±1 % F.S. (at +20 °C +68 °F)
Within ±0.5 % F.S. (at +20
°
C +68
°
F)
Within ±1 % F.S. (at +20 °C +68 °F)
Within ±0.5 % F.S. (at +20
°
C +68
°
F)
Asia: M5 female thread + R (PT) 1/8 male thread >e[cluding DP-Ƒ-M(-P)], Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread
Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm
2
, or more, cable
Net weight: 40 g appro[. (DP-10Ƒ-M(-P): 30 g appro[.), Gross weight: 135 g appro[. (DP-10Ƒ-M(-P):125 g appro[.)
CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (e[cluding M8 plug-in connector type)
DP-102A-N(-P)
Model No.
í101 to +1,010 kPa
í1.03 to +10.30 kgf/cm2
í1.01 to +10.10 bar
í14.6 to +146.4 psi
í0.101 to +1.010 MPa
í101 to +1,010 kPa
í1.03 to +10.30 kgf/cm2
í1.01 to +10.10 bar
í14.6 to +146.4 psi
í0.101 to +1.010 MPa
í1.030 to +1.030 kgf/cm2
í1.010 to +1.010 bar
í14.64 to +14.64 psi
í757 to +757 mmHg
í29.8 to 29.8 inHg
í101.0 to +101.0 kPa
í1.030 to +1.030 kgf/cm2
í1.010 to +1.010 bar
í14.64 to +14.64 psi
í757 to +757 mmHg
í29.8 to 29.8 inHg
í101.0 to +101.0 kPa
í101 to +1,010 kPa
í1.03 to +10.30 kgf/cm2
í1.01 to +10.10 bar
í14.6 to +146.4 psi
í0.101 to +1.010 MPa
í101 to +1,010 kPa
í1.03 to +10.30 kgf/cm2
í1.01 to +10.10 bar
í14.6 to +146.4 psi
í0.101 to +1.010 MPa
í1.030 to +1.030 kgf/cm2
í1.010 to +1.010 bar
í14.64 to +14.64 psi
í757 to +757 mmHg
í29.8 to 29.8 inHg
í101.0 to +101.0 kPa
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2)
Model Nos. of Asia type having “-M´ are short pressure port type. Model Nos. of Asia and North America types having the suffi[-P” are PNP output type.
3) Cannot be used at the same time.
Type
Asia (Note 2)
Europe
M8 plug-in connector type
North America (Note 2)
Item
11
DP-100
I/O CIRCUIT AND WIRING DIAGRAMS
I/O circuit diagram
I/O circuit diagram
Symbols  D : Reverse supply polarity protection diode
Z
D1, ZD2 : Surge absorption zener diode
T
r1, Tr2 : NPN output transistor
Symbols  D : Reverse supply polarity protection diode
Z
D1, ZD2 : Surge absorption zener diode
T
r1, Tr2 : PNP output transistor
12 to 24 V DC
±
10 %
+
í
(Black) Comparative output 1
Load
Load
(White) Comparative output 2
Tr1
ZD2
ZD1
Tr2
100 mA ma[.
100 mA ma[.
(Blue) 0 V
D
Terminal Designation
+V
Comparative output 1
Standard type: Comparative output 2
Multi-function type: Analog output or E[ternal input
0 V
Terminal arrangement diagram
Terminal Designation
+V
Comparative output 1
Standard type: Comparative output 2
Multi-function type: Analog output or E[ternal input
0 V
Terminal arrangement diagram
Standard type
Standard type
1
2
3
1
1
2
3
4
2 3 4
1
1
2
3
4
2 3 4
4
Users’ circuitInternal circuit
Sensor circuit
Terminal No.
Color code of connector attached cable
(Brown) +V
Symbols  D1, D2 : Reverse supply polarity protection diode
Z
D1 : Surge absorption zener diode
T
r1 : PNP input transistor
T
r2 : NPN output transistor
Multi-function type
Symbols  D1, D2 : Reverse supply polarity protection diode
Z
D1: Surge absorption zener diode
T
r1 : PNP output transistor
T
r2 : NPN input transistor
Multi-function type
NPN output type
DP-10Ƒ
PNP output type
DP-10Ƒ-P
Users’ circuitInternal circuit
D1
12 to 24 V DC
±
10 %
+
í
Load
Load
Tr1
ZD2
ZD1
Tr2
100 mA ma[.
100 mA ma[.
(Blue) 0 V
Sensor circuit
1
Terminal No.
Color code of connector attached cable
2
3
4
(Black)
Comparative output 1
(White) Comparative output 2
(Brown) +V
D2
D3
1kȍ
Users’ circuitInternal circuit
D1
D3
12 to 24 V DC
±
10 %
+
í
(White) Analog output
or E[ternal input Load
(Black)
Comparative output 1
(Brown) +V
Tr1
5V
ZD1
Tr2
100 mA ma[.
(Blue) 0 V
Sensor circuit
1
3
2
4
Terminal No.
Color code of connector attached cable
D2
1kȍ
Users’ circuitInternal circuit
ZD1
D1
D2
12 to 24 V DC
±
10 %
+
í
(White) Analog output
or E[ternal input Load
(Black)
Comparative output 1
(Brown) +V
Tr1
Tr2
(Blue) 0 V
Sensor circuit
100 mA ma[.
1
2
3
4
Terminal No.
Color code of connector attached cable
D3
12
DP-100
13
I/O CIRCUIT AND WIRING DIAGRAMS
PRECAUTIONS FOR PROPER USE
Never use this product as a sensing device for
personnel protection.
In case of using sensing devices for personnel
protection, use products which meet laws and standards,
such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
The DP-100 series is designed for use with non-corrosive
gas. It cannot be used with liquid or corrosive gas.



Wiring
Make sure that the power supply is off while wiring.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is
connected to an actual ground.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this sensor, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Incorrect wiring will cause problems with operation.






Connection
Do not apply stress directly to the
connection cable leader or to the
connector.

Connector
attached cable
[CN-14A(-R)-CƑ]
Conditions in use for CE conformity
The DP-100 series is a CE conformity product complying with
EMC Directive. The harmonized standard with regard to immunity
that applies to this product is EN 61000-6-2 and the following
condition must be met to conform to that standard.

The MS-DP1-2 panel mounting bracket (optional) and the MS-DP1-3
front protection cover (optional) are also available.

Condition
Mounting
The line to connect with this sensor should be less than
30 m 98.425 ft.

MS-DP1-1 / MS-DP1-5 sensor mounting brackets are available
separately, and it should be used for mounting. When tightening
the sensor to the sensor mounting bracket, use a tightening torque
of 0.5 N·m or less.

Sensor mounting bracket
MS-DP1-1 (Optional)
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for MS-DP1-1
and MS-DP1-5
PNP output type
'3Ƒ(3-
Terminal Designation
+V
0 V
Standard type: Comparative output 2
Multi-function type: Analog output or External input
Comparative output 1
Terminal arrangement diagram
12
34
I/O circuit diagram
12 to 24 V DC
±
10 %
+
í
(Black) Comparative output 1
Load
Load
(White) Comparative output 2
Tr1ZD2
ZD1
Tr2100 mA max.
100 mA max.
(Blue) 0 V
D
Standard type
1
4
2
3
Users’ circuitInternal circuit
Sensor circuit
Terminal No.
Color code of connection cable
(Brown) +V
1 k
ZD1
D1
D2
(White) Analog voltage output
or External input
Load
(Black)
Comparative output 1
Tr1
Tr2
100 mA max.
Multi-function type
1
4
2
3
Users’ circuitInternal circuit
12 to 24 V DC
±
10 %
+
í
(Brown) +V
(Blue) 0 V
Sensor circuit
Terminal No.
Color code of connection cable
Symbols D : Reverse supply polarity protection diode
Z
D1, ZD2 : Surge absorption zener diode
T
r1, Tr2 : PNP output transistor
Symbols D1, D2 : Reverse supply polarity protection diode
Z
D1: Surge absorption zener diode
T
r1 : PNP output transistor
T
r2 : NPN input transistor
Front protection cover
MS-DP1-3
(optional)
Panel mounting bracket
MS-DP1-2
(optional)
( )
1
2
3
4
DP-100
14
14 mm 0.551 in
spanner
PRECAUTIONS FOR PROPER USE
Decide the direction of this product to mount with the sensor.
Mount this product with the M3 female threads of the sensor by
using the attached M3 (length 8 mm 0.315 in) screws. The
tightening torque should be 0.5 N·m or less.
Mount this product with the mounting surface by using the
attached M4 (length 20 mm 0.787 in) screws. The tightening
torque should be 1.2 N·m or less.
Note: It is not possible to mount this product such
that the pressure port faces upward.
Note: Take care that if the cable with connector is sticking out of the side
groove of this product when mounting, the cable may disconnected.
Note: Do not tighten the pressure port by holding the product with the
spanner. It may cause the product breakage.
PipingMounting
If connecting a commercially-available
coupling to the pressure port, attach a
12 mm 0.472 in spanner (14 mm 0.551 in
spanner for DP-100-E type) to the hexagonal
section of the pressure port to secure it, and
tighten at a torque of 9.8 N·m or less. If it is
tightened using excessive torque, it may
damage the coupling or the pressure port.
In addition, wrap sealing tape around the
coupling when connecting it to prevent leaks.
The MS-DP1-4 panel mounting bracket is available when
switching from the DP2 / DP3 series.

An conversion bushing is available for when using the DP-10Ƒ-M short
pressure port type. It can be used to switch between this model and the
DP2 / DP3 series. When connecting to the pressure port, use a tightening
torque of 1.0 N·m or less.

The MS-DP1-FƑ flat attachment is available.
If using the MS-DP1-FƑ flat attachment (optional), install by
following the procedures given below.

12 mm 0.472 in
spanner
Flat attachment
Make sure to mount MS-DP1-FƑ with the sensor properly. If it is
not mounted properly, air leakage may occur.
Take care that the excessive mounting and dismounting of this
product may cause deterioration of the O-ring.
If you touch the O-ring of MS-DP1-FƑ, or any scratch or dust, etc.
is attached to it, air leakage may occur and the sensing
performance may deteriorate.
Take sufficient care when using and storing MS-DP1-FƑ.
The tightening torque should be 1 N·m or less when connecting a
coupling to the pressure port of MS-DP1-FM.
If connecting a commercially-available joint to the pressure port of
the DP-10Ƒ-M, hold the main unit in your hand to steady it, and
tighten to a torque of 1.0 N·m or less. If it is tightened to an
excessive torque, the joint or the main unit may become
damaged.
If connecting a commercially-available joint to the pressure port of
the MS-DP1-7, tighten to a torque of 9.8 N·m or less.
When connecting the coupling to the pressure port of
MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm 0.551 in
spanner and make sure that the tightening torque is 9.8 N·m or
less.
In addition, in order to prevent any leakage, wind a sealing tape
on the coupling when connecting.
Pressure port
faces downward Pressure port
faces leftward Pressure port
faces rightward
Pressure port
faces upward
M3 (length 8 mm 0.315 in)
screw (Accessory)
M3 female thread
M3 female thread
Connector attached cable
Groove
M4 (length 20 mm 0.787 in)
screw (Accessory)
Coupling (Purchase separately.)
Pressure port
14 mm 0.551 in
spanner
DP2-20
ñ101.3kPa
OUT2
OUT1
MODE
$'-
Front protective cover
DPX-04 (Optional)
can be installed on
MS-DP1-4.
DP2 / DP3
DP-100
Insert
Remove
Remove
Panel mounting bracket MS-DP1-4
Conversion bushing MS-DP1-7
M5 female thread Rc 1 8 female thread
Mounting holes
for DP2 / DP3 series
can be used as is.
DP-100
15
PRECAUTIONS FOR PROPER USE
PRO mode
Setting item Description
Reset setting
ECO mode setting
Linked display color
switching
(standard type only)
Display refresh rate
switching
Hysteresis fix value
switching
Setting check code
Setting copy mode
Table of codes
————
ADJ.
NO OFF
OFF
P-1, Lo-1
NC NO Hi-1
NO NC
P-2, Lo-2
NC NO Hi-2
NO NC
NC
NC NO
EASY
EASY
Analog voltage output /
External input
NO / NC
switching
Comparative output 2
output mode
Comparative output 1
output mode
NO / NC
switching
Display color for
main display
Threshold
value display
Display
color linking
Code
2.5 ms MPa 250 ms OFF
5 ms kPa 500 ms STD
10 ms kgf/cm21,000 ms FULL
25 ms bar
50 ms psi
100 ms mmHg
250 ms inchHg
500 ms
1,000 ms
5,000 ms
Code
If the mode selection key is pressed and held for 5 seconds in
RUN mode, the mode will switch to PRO mode.
If the mode selection key is pressed while a setting is being made,
the mode will switch to RUN mode. In this case, the settings that
have been changed will be entered.

Sub display switching Changes the information in the sub display
during RUN mode operation to the desired
alphanumeric display.
Changes the display refresh rate for the
pressure value displayed in the main display.
Sets the hysteresis for EASY mode and window
comparator mode. (8 steps)
Allows the display color for the main display to
be switched in line with the output operation for
comparative output 1 or comparative output 2.
Allows power consumption to be reduced by
dimming the display or turning it off.
Allows the setting details to be checked via
codes.
Allows the setting details for the master sensor
to be copied to slave sensors.
Resets the settings to the factory settings.
1st digit 2nd digit 3rd digit 4th digit
Standard
type only
Multi-function
type
Standard type
Hysteresis
Hysteresis
Red
when ON
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
Green
when ON
Always
red
Always
green
Analog voltage
output
Auto-
reference
Remote
zero-adjustment
Analog current
output
Window
comparator
Window
comparator
5th digit 6th digit 7th digit 8th digit
Response time Unit switching
Display refresh rate
ECO mode
If the mode selection key is pressed and held for 2 seconds in
RUN mode, the mode will switch to MENU SETTING mode.
If the mode selection key is pressed while a setting is being made,
the mode will switch to RUN mode. In this case, the settings that
have been changed will be entered.


Others
RUN mode
MENU SETTING mode
This product has been developed / produced for industrial use.
Use within the rated pressure range.
Do not apply pressure exceeding the pressure withstandability
value. The diaphragm will get damaged and correct operation shall
not be maintained.
Do not use during the initial transient time (0.5 sec. approx.) after
the power supply is switched on.
Avoid dust, dirt, and steam.
Take care that the sensor does not come in direct contact with
water, oil, grease, or organic solvents, such as, thinner, etc.
Do not insert wires, etc., into the pressure port. The diaphragm will
get damaged and correct operation shall not be maintained.
Do not operate the keys with pointed or sharp objects.








7KLVLVWKHQRUPDORSHUDWLQJPRGH
Comparative output 1
output mode setting
Setting item Description
Sets the output mode for comparative output 1.
Unit switching Pressure unit can be changed.
NO / NC switching
Response time setting
Comparative output 2 output mode
setting (standard type only)
Sets the output mode for comparative output 2.
Display color switching
for main display
Analog output / external
input switching
(multi-function type only)
Allows the color for the main display to be changed.
The colors can be set to ‘red / green’ or ‘green / red’
to correspond to ON / OFF output, or it can be fixed
at ‘red’ or ‘green’ all the time.
Sets the response time.
The response time can be selected from 2.5 ms,
5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms,
500 ms, 1,000 ms and 5,000 ms.
Sets normally open (NO) or normally closed (NC).
Allows switching between analog voltage output /
analog current output, and auto-reference input /
remote zero-adjust-ment input.
Setting item Description
Threshold value
setting
Zero-adjustment
function
Key lock function
Peak hold /
bottom hold function
Stops key operations from being accepted.
The threshold values for ON / OFF operation can be changed directly
by pressing the increment key (UP) and the decrement key (DOWN).
This forces the pressure value display to be reset to zero when
the pressure port is open on the atmospheric pressure side.
Displays the peak value and bottom value for fluctuating
pressure. The peak value appears in the main display,
and the bottom value appears in the sub display.
DP-100
16
Sensor
DP-10
Ƒ
Sensor
DP-10Ƒ-M(-P)
20
0.787
20
0.787
M3 female thread, 4 0.157 deep
M5 female thread
12
0.472
Connector
1.5
0.059
30
1.181
30
1.181 9.5
0.374
42.5
1.673 7.5
0.295
R (PT) 1/8
male thread
(North America: NPT 1/8)
25.5
1.004
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from the website.
Europe
G 1/8
male thread
10
0.394 7
0.276
14
0.551
Europe
30
1.181 ø8.3
ø0.327
1.5
0.059
4.5
0.177
30
1.181
25.5
1.004
30
1.181
20
0.787
20
0.787
M3 female thread,
4 0.157 deep
connector
M5 female thread,
4 0.157 deep
Sensor
DP-11Ƒ-E-P--
30
1.181
30
1.181
47.5
1.870 7
0.276
25.5
1.004
15
0.591 7
0.276
1.5
0.059
G 1/8 male thread
9.5
0.374
4.5
0.177
M3 female thread,
4 0.157 deep
M5 female thread
M8 connector
20
0.787
20
0.787
14
0.551
DP-100
17
The CAD data in the dimensions can be downloaded from the website.
Assembly dimensions
Mounting drawing with '3Ƒ
Panel mounting bracket (Optional), Front protection cover (Optional)
MS-DP1-2
MS-DP1-3
Panel cut-out dimensions
34.5
1.358 20
0.787
34.5
1.358
39.3
1.547
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
When “n” units are installed horizontally in series When “n” units are installed vertically in series
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
When 1 unit is installed
31 1.220 Xn + 3.5 0.138 X (n-1)
55 2.165
or more
31 1.220 Xn + 3.5 0.138 X (n-1)
55 2.165
or more
31 0
í
31 0
í
31 0
í
31 0
í
1.220
0
í0.016
1.220 0
í0.016
1.220 0
í0.016
1.220 0
í0.016
DIMENSIONS (Unit: mm in)
Material: POM (Panel mounting bracket)
Polycarbonate (Front protection cover)
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
Sensor mounting bracket (Optional)
MS-DP1-1
Sensor mounting bracket (Optional)
MS-DP1-5
Assembly dimensions
Mounting drawing with DP-1Ƒ
4.2
0.165
9.5
0.374
2-R2.1 R0.083
22
0.866
14.5
0.571
25.5
1.004
4.2
0.165
9.5
0.374
14.5
0.571
2-R2.1 R0.083
ø2.3
ø0.091
1
0.039
22
0.866
t 2
t 0.079 20
0.787
5.5
0.217
44
1.732
R13
R0.512
13
0.512
20
0.787
30
1.181
20
0.787
2-ø3.5 ø0.138
5.3
0.209
( )
( )
15
0.591
30
1.181
30
1.181 45
1.772
45
1.772
7.5
0.295
1.5
0.059
9.5
0.374
t 2
t 0.079
30
1.181
42.5
1.673
12
0.472
( )
( )
8.7
0.343
7.2
0.283
11
0.433
9.5
0.374
7.5
0.295
Panel thickness dimension
1 to 6 mm 0.039 to 0.236 in
18.3
0.720
33.4
1.315
50
1.969
33.4
1.315
M3 female thread,
4 0.157 deep
Connector
Front
protection
cover
M5 female thread,
4 0.157 deep
(52 2.047 max)
12
0.472
R(PT) 1/8
male thread
20
0.787
4.5
0.177
28.5
1.122
49.5
1.949
ø4.5
ø0.177
49.5
1.949
30
1.181
29.5
1.161
53.5
2.106
1.5
0.059
4.5
0.177
30
1.181
R6.75
R0.266
16
0.630
ø8.3
ø0.327
t 1.5
t0.059
28
1.102
20
0.787
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
Assembly dimensions
Mounting drawing with DP-1Ƒ-M
22.75
0.896
20
0.787
29.5
1.161
20
0.787
13.5
0.531
4.5
0.177
44.5
1.752
30
1.181
28
1.102
t 1.5
t 0.059
8.5
0.335
ø4.5
ø0.177
2-ø3.5 ø0.138
20
0.787
View A
DP-100
18
The CAD data in the dimensions can be downloaded from the website.
DIMENSIONS (Unit: mm in)
Assembly dimensions
Mounting drawing with DP-10Ƒ
Panel mounting bracket (Optional)
MS-DP1-4
Assembly dimensions
Mounting drawing with DP-10Ƒ-M
Flat attachment (Optional)
MS-DP1-FM
Material: Panel mounting bracket body  Nylon 6
Panel mounting bracket  Stainless steel (SUS304)
Spacer  Cold rolled carbon steel (SPCC)(Uni-chrome plated)
Panel cut-out dimensions
Spacer
Connector
M5 female
thread
12
0.472
30
1.181
30
1.181
40
1.575
42.7
1.681
( )
3
0.118
36
1.417
6.5
0.256
26.5
1.043
9.7
0.382
( )
42.7
1.681
Panel thickness dimension 1 to 3.2 mm
0.039 to 0.126 in
8
0.315
Front protection cover (DPX-04)
Panel mounting
bracket body
Panel mounting
bracket
R 1/8
male thread
56
2.205
80
3.150
36
1.417
+0.5
0
+
0.020
0
36
1.417
+0.5
0
+
0.020
0
40
1.575
Material: EnclosurePolybutylene
terephthalate (PBT)
(Glass fiber reinforced)
Pressure portStainless steel
(SUS303)
O-ringHydrogenated Nitrile
Butadiene Rubber
(H-NBR)
Weight: 15 g approx. (flat attachment only)
Two M3 (length 8 mm 0.315 in) screws,
two M4
(length 20 mm 0.787 in) screws are
attached.
M5 female thread
8.5 0.335
Conversion bushing (Optional)
MS-DP1-7
Material: Brass (Nickel plated)
Weight: 10 g approx.
3.5
0.138 7.8
0.307
8
0.315
11 0.433 10 0.394
14
0.551
M5 male thread
Gasket
Rc
1/8
female thread
0.5
0.020
( )
15.8
0.622
Assembly dimensions
Mounting drawing with DP-10Ƒ-M
Flat attachment (Optional)
MS-DP1-FR/FN/FE
5.5 0.217
6.5 0.256
20
0.787
5.5 0.217
6.5 0.256
44.5
1.752
24
0.945
44.5
1.752
2-ø4.3 ø0.169
11.5
0.453
37
1.457
17.5
0.689
11
0.433
30
1.181
24
0.945
24
0.945
30
1.181
( )
( )
Note: The panel tickness should be 1 to 32 mm 0.039 to 1.260 in.
Material: Enclosure
Polybutylene terephthalate (PBT)
(Glass fiber reinforced)
Pressure port
Stainless steel (SUS303)
O-ringHydrogenated Nitrile
Butadiene Rubber (H-NBR)
Weight: 25 g approx. (flat attachment only)
Two M3 (length 8 mm 0.315 in) screws, two M4
(length 20 mm 0.787 in) screws are attached.
37
1.457
11
0.433
8.5
0.335
17.5
0.689
11.5
0.453
Note: MS-DP1-FR has a
Rc1/8 female thread.
MS-DP1-FN has a
NPT1/8 female thread.
Pressure port
G
1
/
8
female thread (Note)
20
0.787
14
0.551
13.5
0.531
Product distinguishing mark
MS-DP1-FR: 0 line
MS-DP1-FN: 1 line
MS-DP1-FE: 2 line
52.5
2.067
( )
24
0.945
( )
30
1.181 24
0.945
2-ø4.3
ø0.169
52.5
2.067
30
1.181
24
0.945
Model No. Cable length L (mm in)
1,000 39.370
2,000 78.740
3,000 118.110
5,000 196.850
CN-14A(-R)-C1
CN-14A(-R)-C2
CN-14A(-R)-C3
CN-14A(-R)-C5
Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
CN-14A(-R)-CƑ
35
1.378
8
0.315
50
1.969
L
ø3.7 ø0.146 cable
( )
( )
8
0.315
( )
( )
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from the website.
Please contact ..........
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Global Sales Department
Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591
panasonic.net/id/pidsx/global
All Rights Reserved © 2013
Specifications are subject to change without notice. Printed in JapanNo. CE-DP100V2-5 November, 2013