(Pa)
Model no.
Rated voltage
Operating voltage range
Rated current
Rated input Rated speed Max. airow
Max. static pressure
SPL
Operating temperature
Expected life
[V] [V] [A] [W] [min-1]
[m³/min]
[CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109R0605H401
5 4.5 to 5.5
0.34 1.7 3800 0.53 18.7 40.2 0.161 28 -20 to +70
60000/60˚C
109R0605F401 0.2 1.0 3200 0.44 15.5 29.4 0.118 24 -20 to +60
109R0605M401 0.13 0.65 2600 0.36 12.7 19.6 0.079 20 -20 to +70
109R0612J401
12
10.8 to 13.2 0.47 5.64 7600 1.06 37.1 155.0 0.622 44 -20 to +60
40000/60˚C
109R0612G401 0.24 2.88 5600 0.78 27.5 87.3 0.351 39
-20 to +70
60000/60˚C
109R0612D401 10.2 to 13.8 0.21 2.52 5150 0.72 25.4 73.5 0.295 37
109R0612S401
6 to 13.8
0.17 2.04 4600 0.65 23.0 56.8 0.228 33
109R0612H401 0.11 1.32 3800 0.53 18.7 40.1 0.161 28
109R0612F401 0.09 1.08 3200 0.44 15.5 29.4 0.118 24
109R0612M401 7 to 13.8 0.06 0.72 2600 0.36 12.7 19.6 0.079 20
109R0624J401
24
21.6 to 26.4 0.24 5.76 7600 1.06 37.1 155.0 0.622 44 -20 to +60
40000/60˚C
109R0624G401 20.4 to 27.6 0.13 3.12 5600 0.78 27.5 87.3 0.351 39
-20 to +70
109R0624D401
12 to 27.6
0.12 2.88 5150 0.72 25.4 73.5 0.295 37
109R0624S401 0.08 1.92 4600 0.65 23.0 56.8 0.228 33
60000/60˚C
109R0624H401 0.06 1.44 3800 0.53 18.7 40.2 0.161 28
109R0624F401 0.05 1.2 3200 0.44 15.5 29.4 0.118 24
109R0624M401 14 to 27.6 0.04 0.96 2600 0.36 12.7 19.6 0.079 20
109R0648J401
48
43.2 to 52.8 0.12 5.76 7600 1.06 37.1 155.0 0.622 44 -20 to +60
40000/60˚C
109R0648G401 43 to 53 0.07 3.36 5600 0.78 27.5 87.3 0.351 39
109R0648H401 40 to 53 0.04 1.92 3800 0.53 18.7 40.2 0.161 28 -20 to +70
60000/60˚C
Other sensor specications are available as options. Refer to the index (p. 545).
DC Fan
60×60×25 mm
San Ace 60 9R type
■General Specications
・ Material ………………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1)
・ Expected life …………………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C,
rated voltage)
・ Motor protection function ………………… Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 529.
・ Dielectric strength …………………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
・ Insulation resistance ………………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
・ Sound pressure level (SPL) ……………… At 1 m away from the air inlet
・ Storage temperature ……………………… -30 to +70˚C (Non-condensing)
・ Lead wire ……………………………………… Red Black or Blue Sensor Yellow
・ Mass ……………………………………………… 90 g
■Specications
The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers.
Operating voltage range Operating voltage range Operating voltage range
■Airow - Static Pressure Characteristics
109R0605H401 With pulse sensor 109R0605F401 With pulse sensor 109R0605M401 With pulse sensor
Static pressure
Static pressure
Airow Airow
Static pressure
Airow